Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
33
result(s) for
"Ritoban Basu Thakur"
Sort by:
Identifying Drivers of Energy Resolution Variation in a Multi-KID Phonon-Mediated Detector
by
Chang, Yen-Yung
,
Bumble, Bruce
,
Ramanathan, Karthik
in
Aluminum
,
Characterization and Evaluation of Materials
,
Condensed Matter Physics
2022
Phonon-mediated Kinetic Inductance Detectors (KIDs) on silicon substrates have demonstrated both
O
(10) eV energy resolution and mm position resolution when used as particle detectors, making them strong candidates for instrumenting next-generation rare event experiments such as in looking for dark matter. Previous work has demonstrated the performance of an 80-KID array on a Si wafer; however, current energy resolution measurements show a
∼
25
×
difference between otherwise identical KIDs—between 5 and 125 eV on energy absorbed by the KID. Here, we use a first principles approach and attempt to identify the drivers behind the variation. In particular, we analyze a subset of 8 KIDs using the unique approach of pulsing neighboring KIDs to generate signals in the target. We tentatively identify differences in quality factor as the likely culprit for the observed differences.
Journal Article
Site Quality Analysis for an Indian Submillimeter Telescope: A Reanalysis-based Approach
by
Sathyanarayana Rao, Mayuri
,
Basu Thakur, Ritoban
,
Singh, Tanmay
in
Altitude
,
Astronomy
,
Atmospheric models
2026
The Himalayan plateau region of Ladakh, India, is a potential host for a science-class submillimeter observatory, building on existing astronomical infrastructure near Hanle and Merak. Using the fifth-generation European Centre for Medium-Range Weather Forecasts Reanalysis (ERA5) data, we analyze precipitable water vapor (PWV) at monthly resolution over 184 months from 2010 January to 2025 April, map PWV statistics across Ladakh, and identify candidate regions that reach PWV ≤1 mm. For promising locations, we compute atmospheric transmittance and the corresponding atmospheric photon-noise using the am (Atmospheric Model) radiative transfer code; we present transmittance and brightness temperature estimates over 10–1000 GHz and compare the inferred performance to sites hosting current or planned submillimeter facilities worldwide. We find Ladakh to be favorable for submillimeter observations, with multiple ERA5 grid cells reaching PWV ≤ 1 mm. Within ERA5’s spatial resolution, two regions emerge as particularly promising: Site A (≈34.25∘N, 78.75∘E) and Site B (≈32.50∘N, 79.00∘E), which satisfy PWV ≤1 mm for about 23% and 19% of the study duration, respectively, compared to about 5% and 8% for the Hanle and Merak grid cells. These results motivate targeted in situ radiometer measurements for final site selection.
Journal Article
Modeling of Cosmic Rays and Near-IR Photons in Aluminum KIDs
by
Janssen, Reinier
,
LeDuc, Henry
,
Hailey-Dunsheath, Steven
in
Aerospace environments
,
Aluminum
,
Characterization and Evaluation of Materials
2024
The PRobe far-Infrared Mission for Astrophysics (PRIMA) is working to develop kinetic inductance detectors (KIDs) that can meet the sensitivity targets of a far-infrared spectrometer on a cryogenically cooled space telescope. An important ingredient for achieving high sensitivity is increasing the fractional-frequency responsivity. Here, we present a study of the responsivity of aluminum KIDs fabricated at the Jet Propulsion Laboratory. Specifically, we model the KID’s temporal response to pair-breaking excitations in the framework of the Mattis–Bardeen theory, incorporating quasiparticle recombination dynamics and the pair-breaking efficiency. Using a near-IR laser, we measure time-resolved photon pulses and fit them to our model, extracting the time-resolved quasiparticle density and the quasiparticle recombination lifetime. Comparing the fit to the known energy of the laser provides a measurement of the pair-breaking efficiency. In addition to photon-sourced excitations, it is important to understand the KID’s response to phonon-sourced excitations from cosmic rays. We measure the rate of secondary cosmic rays detected by our devices and predict the dead time due to cosmic rays for an array in L2 orbit. This work provides confidence in KIDs’ robustness to cosmic ray events in the space environment.
Journal Article
Development of Superconducting On-chip Fourier Transform Spectrometers
2023
Superconducting On-chip Fourier Transform Spectrometers (SOFTS) are broadband, ultra-compact and electronic interferometers. SOFTS will enable kilo-pixel spectro-imaging focal planes, enhancing sub-millimeter astrophysics and cosmology. Particular applications include cluster astrophysics, cosmic microwave background (CMB) science, and line intensity mapping. This article details the development, design and bench-marking of radio frequency (RF) on-chip architecture of SOFTS for Ka and W-bands.
Journal Article
CMB-S4: Forecasting Constraints on Primordial Gravitational Waves
by
Sathyanarayana Rao, Mayuri
,
Allen, Steven W
,
Boddy, Kimberly K
in
Closed loops
,
Constraints
,
Cosmic microwave background
2022
CMB-S4—the next-generation ground-based cosmic microwave background (CMB) experiment—is set to significantly advance the sensitivity of CMB measurements and enhance our understanding of the origin and evolution of the universe. Among the science cases pursued with CMB-S4, the quest for detecting primordial gravitational waves is a central driver of the experimental design. This work details the development of a forecasting framework that includes a power-spectrum-based semianalytic projection tool, targeted explicitly toward optimizing constraints on the tensor-to-scalar ratio, r, in the presence of Galactic foregrounds and gravitational lensing of the CMB. This framework is unique in its direct use of information from the achieved performance of current Stage 2–3 CMB experiments to robustly forecast the science reach of upcoming CMB-polarization endeavors. The methodology allows for rapid iteration over experimental configurations and offers a flexible way to optimize the design of future experiments, given a desired scientific goal. To form a closed-loop process, we couple this semianalytic tool with map-based validation studies, which allow for the injection of additional complexity and verification of our forecasts with several independent analysis methods. We document multiple rounds of forecasts for CMB-S4 using this process and the resulting establishment of the current reference design of the primordial gravitational-wave component of the Stage-4 experiment, optimized to achieve our science goals of detecting primordial gravitational waves for r > 0.003 at greater than 5σ, or in the absence of a detection, of reaching an upper limit of r < 0.001 at 95% CL.
Journal Article
Significant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier
2026
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Travelling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ~5x improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing O(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.
Wideband Direct Detection Constraints on Hidden Photon Dark Matter with the QUALIPHIDE Experiment
2022
We report direction detection constraints on the presence of hidden photon dark matter with masses between 20-30 ueV using a cryogenic emitter-receiver-amplifier spectroscopy setup designed as the first iteration of QUALIPHIDE (QUantum LImited PHotons In the Dark Experiment). A metallic dish sources conversion photons from hidden photon kinetic mixing onto a horn antenna which is coupled to a C-band kinetic inductance traveling wave parametric amplifier, providing for near quantum-limited noise performance. We demonstrate a first probing of the kinetic mixing parameter \"chi\" to just above 10^-12 for the majority of hidden photon masses in this region. These results not only represent stringent constraints on new dark matter parameter space but are also the first demonstrated use of wideband quantum-limited amplification for astroparticle applications
Identifying drivers of energy resolution variation in multi-KID phonon-mediated detectors
by
Yen-Yung, Chang
,
Bumble, Bruce
,
Ramanathan, Karthik
in
Dark matter
,
Energy resolution
,
First principles
2022
Phonon-mediated particle detectors employing Kinetic Inductance Detectors (KIDs) on Silicon substrates have demonstrated both O(10) eV energy resolution and mm position resolution, making them strong candidates for instrumenting next generation rare-event experiments such as in looking for dark matter or in neutrino measurements. Previous work has demonstrated the performance of an 80-KID array on a Si wafer, however current energy resolution measurements show a 25x difference between otherwise identical KIDs on the same wafer - between 5 to 125 eV on energy absorbed by the KID. Here, we use a first principles approach and attempt to identify the drivers behind the resolution variation. In particular, we analyze a subset of 8 KIDs using the unique approach of pulsing neighboring KIDs to generate signals in the target. We tentatively identify differences in quality factor terms as the likely culprit for the observed variation.
OLIMPO: a Balloon-Borne SZE Imager to Probe ICM Dynamics and the WHIM
by
Avestruz, Camille
,
Lamagna, Luca
,
Battistelli, Elia Stefano
in
Angular resolution
,
Balloons
,
Filaments
2024
OLIMPO is a proposed Antarctic balloon-borne Sunyaev-Zel'dovich effect (SZE) imager to study gas dynamics associated with structure formation along with the properties of the warm-hot intergalactic medium (WHIM) residing in the connective filaments. During a 25 day flight OLIMPO will image a total of 10 z~0.05 galaxy clusters and 8 bridges at 145, 250, 365, and 460 GHz at an angular resolution of 1.0'-3.3'. The maps will be significantly deeper than those planned from CMB-S4 and CCAT-P, and will have excellent fidelity to the large angular scales of our low-z targets, which are difficult to probe from the ground. In combination with X-ray data from eROSITA and XRISM we will transform our current static view of galaxy clusters into a full dynamic picture by measuring the internal intra-cluster medium (ICM) velocity structure with the kinematic SZE, X-ray spectroscopy, and the power spectrum of ICM fluctuations. Radio observations from ASKAP and MeerKAT will be used to better understand the connection between ICM turbulence and shocks with the relativistic plasma. Beyond the cluster boundary, we will combine thermal SZE maps from OLIMPO with X-ray imaging from eROSITA to measure the thermodynamics of the WHIM residing in filaments, providing a better understanding of its properties and its contribution to the total baryon budget.
Performance of a phonon-mediated detector using KIDs optimized for sub-GeV dark matter
by
Yen-Yung, Chang
,
Bumble, Bruce
,
Ramanathan, Karthik
in
Dark matter
,
Design modifications
,
Energy
2021
Detection of sub-GeV dark matter candidates requires sub-keV detector thresholds on deposited energy. We provide an update on a gram-scale phonon-mediated KID-based device that was designed for a dark matter search in this mass range at the Northwestern Experimental Underground Site. Currently, the device is demonstrating 6 eV resolution on the energy absorbed by the resonator. With some important assumptions, this translates to 20 eV baseline resolution on energy deposited in the substrate. We show that TLS noise dominates this energy resolution estimate. After modifying the design to mitigate TLS noise, we project 5 eV baseline resolution on energy deposited in the substrate (1.5 eV on energy absorbed by the resonator) for an amplifier-white-noise-dominated device. Finally, we present a clear path forward to sub-eV thresholds, which includes installation of a quantum-limited superconducting parametric amplifier and adjustments to the material makeup of our resonators.