Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
13 result(s) for "Sahlein, Daniel"
Sort by:
Adjunctive Middle Meningeal Artery Embolization for Subdural Hematoma
In patients with subdural hematoma and an indication for surgical evacuation, middle meningeal artery embolization plus surgery led to a lower risk of reoperation for recurrence or progression within 90 days than surgery alone.
Principles, techniques and applications of high resolution cone beam CT angiography in the neuroangio suite
The aim of this review is to describe the acquisition and reformatting of state of the art high resolution cone beam CT (HR-CBCT) and demonstrate its role in multiple neurovascular conditions as a tool to improve the understanding of disease and guide therapeutic decisions. First, we will review the basic principle of CBCT acquisition, followed by the injection protocols and the reformatting paradigms. Next, multiple applications in different pathological conditions such as aneurysms, arteriovenous malformations, dural arteriovenous fistulas, and stroke will be described. HR-CBCT angiography, widely available, is uniquely useful in certain clinical scenarios to improve the understanding of disease and guide therapeutic decisions. It rapidly is becoming an essential tool for the contemporary neurointerventionalist.AChoAho
Artificial intelligence aneurysm measurement tool finds growth in all aneurysms that ruptured during conservative management
BackgroundCerebral aneurysm rupture is associated with high rates of morbidity and mortality. Detecting aneurysms at high risk of rupture is critical in management decision making. Rupture risk has traditionally been associated with size—measured as a maximum dimension. However, aneurysms are morphologically dynamic, a characteristic ignored by large prospective aneurysm risk studies. Manual measurement is challenging and fraught with error. We used an artificial intelligence (AI) measurement tool to study aneurysms that ruptured during conservative management to detect changes in size not appreciated by manual linear measurement.MethodsA single practice database with >5000 aneurysms was queried. Patients followed conservatively for an unruptured aneurysm were identified using appropriate diagnosis codes. This cohort was screened for subsequent rupture using procedure codes. Only patients with two vascular imaging studies before rupture were included.ResultsFive patients met the criteria. All patients had aneurysm enlargement, two of which were not detected from manual linear measurements, including adjudication and analysis, during a multidisciplinary neurovascular conference in a high volume practice. Maximum dimension increased at a minimum of 1.8% (range 1.8–63.3%) from the first scan to the last, and aneurysm volume increased at a minimum of 5.9% (5.9–385.5%), highlighting the importance of volumetric measurement.ConclusionsAI-enabled volumetric measurements are more sensitive to changes in size and detected enlargement in all aneurysms that ruptured during conservative management. This finding has major implications for clinical practice and methods used for interval aneurysm measurement in patients being conservatively followed.
Endovascular intervention for the treatment of epistaxis: cone beam CT review of anatomy, collateral, and treatment implications/efficacy
Epistaxis is common, impacting more than half the population, and can require procedural intervention in approximately 10% of cases. With an aging population and increasing use of antiplatelets and anticoagulants, severe epistaxis is likely to increase in frequency significantly over the next two decades. Sphenopalatine artery embolization is rapidly becoming the most common type of procedural intervention. The efficacy of endovascular embolization is dependent on a refined understanding of the anatomy and collateral physiology of this circulation as well as the impact of temporizing measures such as nasal packing and inflation of a nasal balloon. Likewise, safety is dependent on a detailed appreciation of collateralization with the internal carotid artery and ophthalmic artery. Cone beam CT imaging has the resolution to enable a clear visualization of the anatomy and collateral circulation associated with the arterial supply to the nasal cavity, in addition to assisting with hemorrhage localization. We present a review of epistaxis treatment, a detailed description of anatomic and physiologic considerations informed by cone beam CT imaging, and a proposed protocol for sphenopalatine embolization for which there is currently no standard.
SuperDyna: Unlocking the Potential of Post-Treatment Device Evaluation
BackgroundCurrent imaging algorithms for post-device evaluation are limited by either poor representation of the device or poor delineation of the treated vessel. Combining the high-resolution images from a traditional three-dimensional digital subtraction angiography (3D-DSA) protocol with the longer cone-beam computed tomography (CBCT) protocol may provide simultaneous visualization of both the device and the vessel content in a single volume, improving the accuracy and detail of the assessment. We aim here to review our use of this technique which we termed “SuperDyna”.MethodsIn this retrospective study, patients who underwent an endovascular procedure between February 2022 and January 2023 were identified. We analyzed patients who had both non-contrast CBCT and 3D-DSA post-treatment and collected information on pre-/post-blood urea nitrogen, creatinine, radiation dose, and the intervention type.ResultsIn 1 year, SuperDyna was performed in 52 (of 1935, 2.6%) patients, of which 72% were women, median age 60 years. The most common reason for the addition of the SuperDyna was for post-flow diversion assessment (n=39). Renal function tests showed no changes. The average total procedure radiation dose was 2.8 Gy, with 4% dose and ~20 mL of contrast attributed to the additional 3D-DSA needed to generate the SuperDyna.ConclusionsThe SuperDyna is a fusion imaging method that combines high-resolution CBCT and contrasted 3D-DSA to evaluate intracranial vasculature post-treatment. It allows for more comprehensive evaluation of the device position and apposition, aiding in treatment planning and patient education.
SOFIA Aspiration System as first-line Technique (SOFAST): a prospective, multicenter study to assess the efficacy and safety of the 6 French SOFIA Flow Plus aspiration catheter for endovascular stroke thrombectomy
BackgroundMechanical thrombectomy (MT) is the standard of care for acute ischemic stroke (AIS) patients with large vessel occlusion (LVO). The SOFAST study collected clinical evidence on the safety and efficacy of the 6 French SOFIA Flow Plus aspiration catheter (SOFIA 6F) when used as first-line treatment.MethodsThis was a prospective, multicenter investigation to assess the safety and efficacy of SOFIA 6F used for first-line aspiration. Anterior circulation LVO stroke patients were enrolled. The primary endpoint was the final modified Thrombolysis in Cerebral Infarction (mTICI)≥2b rate. Secondary endpoints included first-pass and first-line mTICI≥2b rates, times from arteriotomy to clot contact and mTICI≥2b, and 90-day modified Rankin Scale (mRS)≤2. First-line and final mTICI scores were adjudicated by an independent imaging core lab. Safety events were assessed by an independent clinical events adjudicator.ResultsA total of 108 patients were enrolled across 12 centers from July 2020 to June 2022. Median age was 67 years, median National Institutes of Health Stroke Scale (NIHSS) was 15.5, and 56.5% of patients received intravenous thrombolytics. At the end of the procedure, 97.2%, 85.2%, and 55.6% of patients achieved mTICI≥2b, ≥2c, and 3, respectively. With SOFIA 6F first-line aspiration, 87.0%, 79.6%, and 52.8% achieved mTICI≥2b, ≥2c, and 3, respectively. After the first pass, 75.0%, 70.4%, and 50.9% achieved mTICI≥2b, ≥2c, and 3, respectively. Median times from arteriotomy to clot contact and successful revascularization were 12 and 17 min, respectively. At 90 days, 66.7% of patients achieved mRS≤2.ConclusionsFirst-line aspiration with SOFIA 6F is safe and effective with high revascularization rates and short procedure times.
EMBOLISE randomized surgical trial for subdural hematoma: clinical benefits beyond reoperation with middle meningeal artery embolization
BackgroundRandomized clinical trials have demonstrated that middle meningeal artery embolization (MMAe) reduces reoperation rates in surgically treated patients with subacute/chronic subdural hematoma (SDH). The effect of embolization on outcomes beyond reoperation remains to be determined. We analyzed the impact of reoperation and healthcare encounters among patients enrolled in the EMBOLISE trial.MethodsSymptomatic subacute/chronic SDH patients were randomized to surgical evacuation alone (control) or surgical evacuation plus Onyx MMAe (treatment). Changes in modified Rankin Scale (mRS) scores, frequency of unscheduled follow-up visits, and radiographic evolution of hematomas in patients with versus without reoperation were analyzed.ResultsA total of 197 patients were randomly assigned to the treatment group and 203 to the control group. Patients who required reoperation compared with those who did not exhibited a ~threefold higher incidence of mRS >2 (37.0% vs 12.9%, P=0.0025) and an ~2.5 fold increase in mRS worsening (22.2% vs 9.5%, P=0.0503) at 180 days. In patients who did not receive MMAe, there was a ~threefold fold increase in rate of SDH recurrence/progression even among those who did not require reoperation (14.3% vs 5.3%, P=0.0045) and a ~twofold increase in unscheduled physician follow-up visits (27.1% vs 14.7%, P=0.0031).ConclusionAmong patients with symptomatic subacute/chronic SDH, reoperation was associated with increased rates of mRS worsening and higher mRS scores at follow-up. Adjunctive Onyx MMAe resulted in lower rates of hematoma recurrence/progression and fewer unscheduled physician follow-up visits. Thus, in addition to reducing surgical reoperation rates, adjunctive MMAe led to improved clinical outcomes and reduced healthcare encounters.
Endovascular Thrombectomy Following Acute Ischemic Stroke: A Single-Center Case Series and Critical Review of the Literature
Acute ischemic stroke (AIS) due to thrombo-embolic occlusion in the cerebral vasculature is a major cause of morbidity and mortality in the United States and throughout the world. Although the prognosis is poor for many patients with AIS, a variety of strategies and devices are now available for achieving recanalization in patients with this disease. Here, we review the treatment options for cerebrovascular thromboembolic occlusion with a focus on the evolution of strategies and devices that are utilized for achieving endovascular clot extraction. In order to demonstrate the progression of this treatment strategy over the past decade, we will also present a single-center case series of AIS patients treated with endovascular thrombectomy.
Surpass Intracranial Aneurysm Embolization System Pivotal Trial to Treat Large or Giant Wide-Neck Aneurysms – SCENT: 3-year outcomes
BackgroundTo report the 3-year safety and effectiveness of the Surpass Streamline flow diverter in the SCENT trial (Surpass Intracranial Aneurysm Embolization System Pivotal Trial to Treat Large or Giant Wide-Neck Aneurysms).MethodsThe Surpass Streamline flow diverter device was evaluated in a multicenter, prospective, single-arm, non-randomized interventional trial including patients with uncoilable or previously treated but failed aneurysms of the intracranial internal carotid artery. 3-year outcomes were tabulated with descriptive statistics and compared with 1-year outcomes.ResultsOf 180 patients in the modified intent-to-treat (mITT) cohort, 36-month clinical and angiographic follow-up was available in 134 and 117 cases, respectively. Effectiveness endpoint of complete aneurysm occlusion without clinically significant stenosis or retreatment was met in 71.8% (79/110, 95% CI 62.4% to 80.0%) of cases. Safety composite endpoint was 12.2% (22/180) over the 3-year period, with two major safety events (ipsilateral ischemic strokes) occurring between 12–36 months. Complete aneurysm occlusion was noted in 77.8% (91/117), and 99.1% (116/117) of the patients demonstrated adequate aneurysm occlusion (complete occlusion or neck residual). There were four cases (2.2%) of aneurysm rupture, all occurring within the first month of the index procedure. Target aneurysm retreatment rate was 2.8% (5/180).ConclusionThe present findings support the long-term safety and effectiveness of the Surpass Streamline flow diverter device.Trial registration NCT01716117.