Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
6 result(s) for "Sai Chaitanya Susarla"
Sort by:
The Indian Pulsar Timing Array: First data release
We present the pulse arrival times and high-precision dispersion measure estimates for 14 millisecond pulsars observed simultaneously in the 300-500 MHz and 1260-1460 MHz frequency bands using the upgraded Giant Metrewave Radio Telescope (uGMRT). The data spans over a baseline of 3.5 years (2018-2021), and is the first official data release made available by the Indian Pulsar Timing Array collaboration. This data release presents a unique opportunity for investigating the interstellar medium effects at low radio frequencies and their impact on the timing precision of pulsar timing array experiments. In addition to the dispersion measure time series and pulse arrival times obtained using both narrowband and wideband timing techniques, we also present the dispersion measure structure function analysis for selected pulsars. Our ongoing investigations regarding the frequency dependence of dispersion measures have been discussed. Based on the preliminary analysis for five millisecond pulsars, we do not find any conclusive evidence of chromaticity in dispersion measures. Data from regular simultaneous two-frequency observations are presented for the first time in this work. This distinctive feature leads us to the highest precision dispersion measure estimates obtained so far for a subset of our sample. Simultaneous multi-band uGMRT observations in Band 3 and Band 5 are crucial for high-precision dispersion measure estimation and for the prospect of expanding the overall frequency coverage upon the combination of data from the various Pulsar Timing Array consortia in the near future. Parts of the data presented in this work are expected to be incorporated into the upcoming third data release of the International Pulsar Timing Array.
Low-frequency wideband timing of InPTA pulsars observed with the uGMRT
High-precision measurements of the pulsar dispersion measure (DM) are possible using telescopes with low-frequency wideband receivers. We present an initial study of the application of the wideband timing technique, which can simultaneously measure the pulsar times of arrival (ToAs) and DMs, for a set of five pulsars observed with the upgraded Giant Metrewave Radio Telescope (uGMRT) as part of the Indian Pulsar Timing Array (InPTA) campaign. We have used the observations with the 300-500 MHz band of the uGMRT for this purpose. We obtain high precision in DM measurements with precisions of the order 10^{-6}cm^{-3}pc. The ToAs obtained have sub-{\\mu}s precision and the root-mean-square of the post-fit ToA residuals are in the sub-{\\mu}s range. We find that the uncertainties in the DMs and ToAs obtained with this wideband technique, applied to low-frequency data, are consistent with the results obtained with traditional pulsar timing techniques and comparable to high-frequency results from other PTAs. This work opens up an interesting possibility of using low-frequency wideband observations for precision pulsar timing and gravitational wave detection with similar precision as high-frequency observations used conventionally.
Nanohertz Gravitational Wave Astronomy during the SKA Era: An InPTA perspective
Decades long monitoring of millisecond pulsars, which exhibit highly stable rotational periods, in pulsar timing array experiments is on the threshold of discovering nanohertz stochastic gravitational wave background. This paper describes the Indian Pulsar timing array (InPTA) experiment, which employs the upgraded Giant Metrewave Radio Telescope (uGMRT) for timing an ensemble of millisecond pulsars for this purpose. We highlight InPTA's observation strategies and analysis methods, which are relevant for a future PTA experiment with the more sensitive Square Kilometer Array (SKA) telescope. We show that the unique multi-sub-array multi-band wide-bandwidth frequency coverage of the InPTA provides Dispersion Measure estimates with unprecedented precision for PTA pulsars, e.g., ~ 2 x 10{-5} pc-cm{-3} for PSR J1909-3744. Configuring the SKA-low and SKA-mid as two and four sub-arrays respectively, it is shown that comparable precision is achievable, using observation strategies similar to those pursued by the InPTA, for a larger sample of 62 pulsars requiring about 26 and 7 hours per epoch for the SKA-mid and the SKA-low telescopes respectively. We also review the ongoing efforts to develop PTA-relevant general relativistic constructs that will be required to search for nanohertz gravitational waves from isolated super-massive black hole binary systems like blazar OJ 287. These efforts should be relevant to pursue persistent multi-messenger gravitational wave astronomy during the forthcoming era of the SKA telescope, the Thirty Meter Telescope, and the next-generation Event Horizon Telescope.
High Precision Measurements of Interstellar Dispersion Measure with the upgraded GMRT
Pulsar radio emission undergoes dispersion due to the presence of free electrons in the interstellar medium (ISM). The dispersive delay in the arrival time of pulsar signal changes over time due to the varying ISM electron column density along the line of sight. Correcting for this delay accurately is crucial for the detection of nanohertz gravitational waves using Pulsar Timing Arrays. In this work, we present in-band and inter-band DM estimates of four pulsars observed with uGMRT over the timescale of a year using two different template alignment methods. The DMs obtained using both these methods show only subtle differences for PSR 1713+0747 and J1909\\(-\\)3744. A considerable offset is seen in the DM of PSR J1939+2134 and J2145\\(-\\)0750 between the two methods. This could be due to the presence of scattering in the former and profile evolution in the latter. We find that both methods are useful but could have a systematic offset between the DMs obtained. Irrespective of the template alignment methods followed, the precision on the DMs obtained is about \\(10^{-3}\\) pc cm\\(^{-3}\\) using only BAND3 and \\(10^{-4}\\) pc cm\\(^{-3}\\) after combining data from BAND3 and BAND5 of the uGMRT. In a particular result, we have detected a DM excess of about \\(5\\times10^{-3}\\) pc cm\\(^{-3}\\) on 24 February 2019 for PSR J2145\\(-\\)0750. This excess appears to be due to the interaction region created by fast solar wind from a coronal hole and a coronal mass ejection (CME) observed from the Sun on that epoch. A detailed analysis of this interesting event is presented.
pinta: The uGMRT Data Processing Pipeline for the Indian Pulsar Timing Array
We introduce pinta, a pipeline for reducing the upgraded Giant Metre-wave Radio Telescope (uGMRT) raw pulsar timing data, developed for the Indian Pulsar Timing Array experiment. We provide a detailed description of the workflow and usage of pinta, as well as its computational performance and RFI mitigation characteristics. We also discuss a novel and independent determination of the relative time offsets between the different back-end modes of uGMRT and the interpretation of the uGMRT observation frequency settings, and their agreement with results obtained from engineering tests. Further, we demonstrate the capability of pinta to generate data products which can produce high-precision TOAs using PSR J1909-3744 as an example. These results are crucial for performing precision pulsar timing with the uGMRT.
Evidence for profile changes in PSR J1713+0747 using the uGMRT
PSR J1713+0747 is one of the most precisely timed pulsars in the international pulsar timing array experiment. This pulsar showed an abrupt profile shape change between April 16, 2021 (MJD 59320) and April 17, 2021 (MJD 59321). In this paper, we report the results from multi-frequency observations of this pulsar carried out with the upgraded Giant Metrewave Radio Telescope (uGMRT) before and after the event. We demonstrate the profile change seen in Band 5 (1260 MHz - 1460 MHz) and Band 3 (300 MHz - 500 MHz). The timing analysis of this pulsar shows a disturbance accompanying this profile change followed by a recovery with a timescale of \\( 159\\) days. Our data suggest that a model with chromatic index as a free parameter is preferred over models with combinations of achromaticity with DM bump or scattering bump. We determine the frequency dependence to be \\(^+1.34\\).