Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
1 result(s) for "Satger Dominique"
Sort by:
Evaluation of 20-MHz high-frequency ultrasonography for the diagnosis of choroidal nevi
PurposeEvaluate short-term intraoperator reproducibility of ultrasonographic measurements of choroidal nevi using 10- and 20-MHz probes, and the efficacy of the high-frequency probes for the diagnosis of choroidal nevi.MethodsDiameters and thicknesses of choroidal nevi were measured using a 10-MHz probe and a high-frequency long focal length 20-MHz probe (Quantel Medical™). The first part of the study evaluated intraoperator reproducibility of measurements of choroidal nevi with 10- and 20-MHz probes and the second part of the study allowed the comparisons of the measurements of largest tumor diameter (LDT) of choroidal nevi of 40 patients between the 10- and 20-MHz probes. The two-way random average agreement intraclass correlation coefficients (ICC), Bland-Altman plot, and a paired t test were used.ResultsThe intraoperator reproducibility of choroidal nevi measurements with 10- and 20-MHz probes was excellent (ICC > 0.9, n = 20). Four flat nevi, not detectable at 10 MHz, could be located with the high-frequency probe (p = 0.12). There was no significant difference in thickness or LTD measurements between the 10- and 20-MHz probes (n = 31). Both techniques showed an excellent agreement (ICC > 0.8) for thickness and LTD measurements. All the choroidal nevi that were not measurable with the 10-MHz probe (n = 7) were measured with the 20-MHz probe.ConclusionThe high-frequency 20-MHz probe allows additional detection and measurements of flat choroidal nevi. When detectable, the ultrasonographic measurements of thickness and diameter of choroidal nevi are similar with both the 10- and the 20-MHz probes.