Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
31
result(s) for
"Schoder, Maria"
Sort by:
Transjugular intrahepatic portosystemic shunts (TIPS) for the prevention of variceal re-bleeding – A two decades experience
by
Karnel, Franz
,
Schwabl, Philipp
,
Sieghart, Wolfgang
in
Biology and Life Sciences
,
Bleeding
,
Bypasses
2018
Transjugular intrahepatic portosystemic shunts (TIPS) are used in patients with cirrhosis for the prevention of variceal rebleeding.
We retrospectively evaluated re-bleeding rate, patency, mortality, and transplant-free survival (TFS) in cirrhotic patients receiving TIPS implantation for variceal bleeding between 1994-2014.
286 patients received TIPS (n = 119 bare metal stents, n = 167 polytetrafluorethylene (PTFE)-covered stents) for prevention of variceal re-bleeding. Mean age was 55.1 years, median MELD was 11.8, and the main etiology of cirrhosis was alcoholic liver disease (70%). Median follow-up was 821 days. 67 patients (23%) experienced at least one re-bleeding event. Patients with PTFE-TIPS were at significantly lower risk for variceal re-bleeding than patients with bare metal stents (14% vs. 37%, OR:0.259; p<0.001) and had less need for stent revision (21% vs. 37%; p = 0.024). Patients with PTFE stent grafts showed lower mortality than patients with bare stents after 1 year (19% vs. 31%, p = 0.020) and 2 years (29% vs. 40%; p = 0.041) after TIPS implantation. Occurrence of hepatic encephalopathy after TIPS was similar between groups (20% vs. 24%, p = 0.449).
PTFE-TIPS were more effective at preventing variceal re-bleeding than bare metal stents due to better patency. Since this tended to translate in improved survival, only covered stents should be implemented for bleeding prophylaxis when TIPS is indicated.
Journal Article
Type II Endoleaks After Endovascular Repair of Abdominal Aortic Aneurysms: Fate of the Aneurysm Sac and Neck Changes During Long-term Follow-up
2012
Purpose
To evaluate the frequency of type II endoleaks after endovascular aneurysm
repair (EVAR) and to compare sac diameter and neck changes in patients with
type II endoleak to endoleak-free patients with at least 3-year imaging
follow-up.
Methods
Among 407 consecutive EVAR patients, 109 patients (101 men; mean age 72.1
years, range 55–86) had at least 3-year computed tomography (CT) data
and no type I or III endoleak. In this cohort, 49 patients presented with a
type II endoleak at some time and 60 patients had no endoleak. Patients with
type II endoleaks were further divided into subgroups based on the vessel
origin and the perfusion status (persistent or transient). The course of the
perfusion status of type II endoleaks and changes in the aneurysm sac
diameters, neck diameters, and renal to stent-graft distances (RSD) were
evaluated in the defined groups. Reintervention and death rates were also
reported.
Results
The mean follow-up was 68.1±23.8 months. Compared to the no endoleak
group, overall sac diameter increased significantly in the type II endoleak
group (p=0.007), but vessel origin did not have any influence. With
regard to the perfusion status of type II endoleaks, aneurysm sac changes
were significantly higher (p = 0.002) in the persistent endoleak
group. During the study period, the increase in the proximal neck diameter
was significantly higher in the no endoleak group compared to the type II
endoleak group (p=0.025). No significant difference was found in RSD
changes between the defined groups. Reinterventions were performed in 20
(18.3%) patients (13 for type II endoleak); 2 (1.8%) patients
without type II endoleak died of ruptured aneurysm.
Conclusion
Persistent type II endoleaks led to significant aneurysm sac enlargement, but
without increased mortality or rupture rates.
Journal Article
Type 2 Endoleaks: The Diagnostic Performance of Non-Specialized Readers on Arterial and Venous Phase Multi-Slice CT Angiography
2016
To define the diagnostic precision of non-specialized readers in the detection of type 2 endoleaks (T2EL) in arterial versus venous phase acquisitions, and to evaluate an approach for radiation dose reduction.
The pre-discharge and final follow-up multi-slice CT angiographies of 167 patients were retrospectively analyzed. Image data were separated into an arterial and a venous phase reading set. Two radiology residents assessed the reading sets for the presence of a T2EL, feeding vessels, and aneurysm sac size. Findings were compared with a standard of reference established by two experts in interventional radiology. The effective dose was calculated.
Overall, experts detected 131 T2ELs, and 331 feeding vessels in 334 examinations. Persistent T2ELs causing aneurysm sac growth > 5 mm were detected in 20 patients. Radiation in arterial and venous phases contributed to a mean of 58.6% and 39.0% of the total effective dose. Findings of reader 1 and 2 showed comparable sensitivities in arterial sets of 80.9 versus 85.5 (p = 0.09), and in venous sets of 73.3 versus 79.4 (p = 0.15), respectively. Reader 1 and 2 achieved a significant higher detection rate of feeding vessels with arterial compared to venous set (p = 0.04, p < 0.01). Both readers correctly identified T2ELs with growing aneurysm sac in all cases, independent of the acquisition phase.
Arterial acquisitions enable non-specialized readers an accurate detection of T2ELs, and a significant better identification of feeding vessels. Based on our results, it seems reasonable to eliminate venous phase acquisitions.
Journal Article
Correction: Type 2 Endoleaks: The Diagnostic Performance of Non-Specialized Readers on Arterial and Venous Phase Multi-Slice CT Angiography
by
Nolz, Richard
,
Woitek, Ramona
,
Wibmer, Andreas
in
Angiography
,
Diagnostic systems
,
Medical imaging
2016
[This corrects the article DOI: 10.1371/journal.pone.0149725.].
Journal Article
Secondary modification into aortouniiliac configuration to salvage failed endovascular aneurysm repair is safe and effective but not associated with higher intervention rates during long-term follow-up
by
Wibmer, Andreas G.
,
Lammer, Johannes
,
Funovics, Martin
in
Abdomen
,
Abdominal aortic aneurysm
,
Aged
2014
Reports of secondary modifications into aortouniiliac configuration to salvage-failed endovascular aneurysm repair (EVAR) are limited. We evaluated long-term results after these procedures and compared them with those after primary aortouniiliac endografting (AUE).
A retrospective review of all EVAR performed from March 1995 until July 2011 was conducted. Patients were included when primary AUE (group I) or modification into aortouniiliac configuration (group II) was done.
Data analysis obtained 27 group I and 23 group II patients. Salvage of failed EVAR could be achieved in 96% of group II patients, and mortality was zero. Frequency of adverse events and amount of interventions to maintain aneurysm exclusion were not increased after secondary AUE. Kaplan–Meier estimates for long-term survival between groups were comparable (P = .36).
Secondary AUE allows correction of graft-related endoleaks potentially leading to late aneurysm rupture. Complications and adverse events throughout long-term follow-up were not necessarily increased when compared with primary AUE.
Journal Article
Covered Transjugular Intrahepatic Portosystemic Shunt Improves Hypersplenism-Associated Cytopenia in Cirrhosis
2022
BackgroundPatients with cirrhosis often develop portal hypertension-associated splenomegaly and hypersplenism, potentially causing severe cytopenia.AIMSSystematic assessment on the impact of transjugular intrahepatic portosystemic shunt (TIPS) implantation on platelet count (PLT), hemoglobin (Hb), and white blood cell count (WBC).MethodsPatients with cirrhosis undergoing covered TIPS implantation were retrospectively included. Patients with malignancies or hematologic disorders were excluded. Hematology lab work was recorded at baseline (pre-TIPS) and at regular intervals after TIPS.ResultsOne hundred ninety-two patients (male: 72.4%, age: 56 ± 10 years; MELD: 12.1 ± 3.6) underwent TIPS implantation. Higher-grade (≥ G2) thrombocytopenia (PLT < 100 G/L) was present in 54 (28.7%), ≥ G2 anemia (Hb < 10 g/dL) in 57 (29.7%), and ≥ G2 leukopenia (WBC < 2 G/L) in 3 (1.6%) patients pre-TIPS, respectively. Resolution of ≥ G2 thrombocytopenia, anemia, and leukopenia occurred in 24/55 (43.6%), 23/57 (40.4%), and 2/3 (66.7%), respectively. Similar results were also observed in the subgroup of patients without ‘bleeding’ TIPS-indication, with improvements of G ≥ 2 thrombocytopenia and of G ≥ 2 anemia in 19.8% and 10.2% of patients after TIPS, respectively.ConclusionsThrombocytopenia, anemia, and leukopenia frequently improved after TIPS. Therefore, moderate- to higher-grade thrombocytopenia should not be regarded as a contraindication against TIPS, but rather be considered in case of severe thrombocytopenia—particularly prior to surgery or interventions.
Journal Article
Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks
2019
ObjectivesTo evaluate the influence of baseline parameters on the occurrence of stent-graft surface movement after endovascular aneurysm repair (EVAR) and to investigate its association with migration and stent-graft-related endoleaks (srEL).MethodsIn this retrospective, cross-sectional study, three-dimensional surface models of the stent-graft, delimited by landmarks using custom-built software, were derived from the pre-discharge and last follow-up computed tomography angiography (CTA). Stent-graft surface movement in the proximal anchoring zone between these examinations was considered significant at a threshold of 9 mm. The Cox proportional hazards model was used to determine baseline variables associated with the occurrence of stent-graft surface movement. The association between migration and srEL with stent-graft surface movement was tested with the chi-square and the Fisher exact test, respectively.ResultsStent-graft surface movement was observed in 54 (28.9%) of 187 patients. Multivariate analysis revealed that age ([HR] 1.05; p = 0.017), proximal neck diameter ([HR] 5.07; p < 0.001), infrarenal aortic neck angulation ([HR] 1.02, p = 0.002), and proximal neck length ([HR] 0.62, p < 0.001) were significantly associated with the occurrence of stent-graft surface movement. Migration and srEL occurred in 17 (31.5%) and 5 (9.3%) patients, with and 11 (8.3%) and 2 (1.5%) without stent-graft surface movement (p < 0.001, p = 0.022).ConclusionsAge, neck diameter, infrarenal neck angulation, and proximal neck length were significantly associated with the occurrence of stent-graft surface movement. Apart from possible use of adjunctive sealing systems, concerned patients may benefit from regular CTA surveillance, enabling timely diagnosis of subtle changes of stent-graft position.Key Points• Stent-graft surface movement, demonstrating subtle, three-dimensional changes in stent-graft position in the proximal anchoring zone, can be derived from CTA examinations.• Age, proximal neck diameter, and infrarenal neck angulation were significantly associated with an increased incidence of stent-graft surface movement. Stent-graft surface movement is significantly more frequent in patients with stent-graft migration and stent-graft-related endoleaks.• Consideration of risk factors for stent-graft surface movement may help to identify patients who might benefit from regular CTA surveillance and timely diagnosis of subtle changes of stent-graft position, enabling re-interventions to prevent migration and srEL.
Journal Article
Endovascular Therapy of Inflammatory Aortic Aneurysms: A Meta-Analysis
by
Lammer, Johannes
,
Reiter, Markus
,
Rand, Thomas
in
Aged
,
Aortic Aneurysm, Abdominal - diagnostic imaging
,
Aortic Aneurysm, Abdominal - surgery
2005
Purpose:
To report a meta-analysis of results from endovascular aneurysm repair (EVAR) of inflammatory aortic aneurysms (IAA).
Methods:
A comprehensive literature review was performed to identify all studies reporting the results of EVAR in patients with IAA. To be included in the analysis, an article had to provide a minimum follow-up of 6 months, information about primary technical success, details of immediate and long-term complications, and evaluation of at least one of the basic outcome criteria: changes in aneurysm sac diameter, periaortic fibrosis (PAF), and/or renal impairment. All studies were reviewed by 2 independent observers for the inclusion criteria. Data were retrieved on the technical and clinical success, outcome criteria, mortality in follow-up, and reinterventions from 14 articles selected from among 701 initially identified.
Results:
The 14 articles encompassed 46 patients (45 men [97.8%]; mean age 65 years, range 59–75) with a mean follow-up of 18 months after endovascular repair of IAAs located in the abdominal aorta. The primary technical success rate was 95.6% (44/46) and the 30-day clinical success rate was 93.4% (43/46). The median aneurysm sac diameter regression was 11 mm. Of 43 patients with PAF prior to the intervention, 22 (51.2%) patients showed complete regression, 18 (41.8%) remained unchanged, and 3 (7.0%) showed progression after EVAR. Renal impairment disappeared in 11 (45.8%) of 24 patients. Reinterventions were reported in 8 patients. The procedure-related and follow-up mortality rates were 0% and 13.0%, respectively.
Conclusions:
EVAR of IAA is feasible, excludes the aneurysm effectively, and reduces PAF and renal impairment in most patients with very low periprocedural and midterm mortality and an acceptable reintervention rate.
Journal Article
Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial
by
Hausegger, Klaus A.
,
Wolf, Florian
,
Rand, Thomas
in
Aged
,
Ankle Brachial Index
,
Anticoagulants - administration & dosage
2015
Purpose
The hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only.
Methods
A prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN
®
Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN
®
versus 17.3 ± 6.6 cm in the BMS group.
Results
The 24-month primary patency rates in the VIABAHN
®
and BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank
p
= 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank
p
= 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN
®
versus BMS (log rank
p
= 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank
p
= 0.004) for VIABAHN
®
versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank
p
= 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (
p
= 0.76) at 24-month in the VIABAHN
®
versus the BMS group, respectively.
Conclusion
At 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244).
Journal Article