Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
532
result(s) for
"Si-Min, He"
Sort by:
A high-speed search engine pLink 2 with systematic evaluation for proteome-scale identification of cross-linked peptides
2019
We describe pLink 2, a search engine with higher speed and reliability for proteome-scale identification of cross-linked peptides. With a two-stage open search strategy facilitated by fragment indexing, pLink 2 is ~40 times faster than pLink 1 and 3~10 times faster than Kojak. Furthermore, using simulated datasets, synthetic datasets,
15
N metabolically labeled datasets, and entrapment databases, four analysis methods were designed to evaluate the credibility of ten state-of-the-art search engines. This systematic evaluation shows that pLink 2 outperforms these methods in precision and sensitivity, especially at proteome scales. Lastly, re-analysis of four published proteome-scale cross-linking datasets with pLink 2 required only a fraction of the time used by pLink 1, with up to 27% more cross-linked residue pairs identified. pLink 2 is therefore an efficient and reliable tool for cross-linking mass spectrometry analysis, and the systematic evaluation methods described here will be useful for future software development.
The identification of cross-linked peptides at a proteome scale for interactome analyses represents a complex challenge. Here the authors report an efficient and reliable search engine pLink 2 for proteome-scale cross-linking mass spectrometry analyses, and demonstrate how to systematically evaluate the credibility of search engines.
Journal Article
Precise, fast and comprehensive analysis of intact glycopeptides and modified glycans with pGlyco3
2021
Great advances have been made in mass spectrometric data interpretation for intact glycopeptide analysis. However, accurate identification of intact glycopeptides and modified saccharide units at the site-specific level and with fast speed remains challenging. Here, we present a glycan-first glycopeptide search engine, pGlyco3, to comprehensively analyze intact N- and O-glycopeptides, including glycopeptides with modified saccharide units. A glycan ion-indexing algorithm developed for glycan-first search makes pGlyco3 5–40 times faster than other glycoproteomic search engines without decreasing accuracy or sensitivity. By combining electron-based dissociation spectra, pGlyco3 integrates a dynamic programming-based algorithm termed pGlycoSite for site-specific glycan localization. Our evaluation shows that the site-specific glycan localization probabilities estimated by pGlycoSite are suitable to localize site-specific glycans. With pGlyco3, we confidently identified N-glycopeptides and O-mannose glycopeptides that were extensively modified by ammonia adducts in yeast samples. The freely available pGlyco3 is an accurate and flexible tool that can be used to identify glycopeptides and modified saccharide units.pGlyco3 is a glycan-first glycopeptide search engine for the identification and localization of site-specific N- and O-glycopeptides, including glycopeptides with modified glycans.
Journal Article
pGlyco 2.0 enables precision N-glycoproteomics with comprehensive quality control and one-step mass spectrometry for intact glycopeptide identification
2017
The precise and large-scale identification of intact glycopeptides is a critical step in glycoproteomics. Owing to the complexity of glycosylation, the current overall throughput, data quality and accessibility of intact glycopeptide identification lack behind those in routine proteomic analyses. Here, we propose a workflow for the precise high-throughput identification of intact N-glycopeptides at the proteome scale using stepped-energy fragmentation and a dedicated search engine. pGlyco 2.0 conducts comprehensive quality control including false discovery rate evaluation at all three levels of matches to glycans, peptides and glycopeptides, improving the current level of accuracy of intact glycopeptide identification. The N-glycoproteome of samples metabolically labeled with
15
N/
13
C were analyzed quantitatively and utilized to validate the glycopeptide identification, which could be used as a novel benchmark pipeline to compare different search engines. Finally, we report a large-scale glycoproteome dataset consisting of 10,009 distinct site-specific N-glycans on 1988 glycosylation sites from 955 glycoproteins in five mouse tissues.
Protein glycosylation is a heterogeneous post-translational modification that generates greater proteomic diversity that is difficult to analyze. Here the authors describe pGlyco 2.0, a workflow for the precise one step identification of intact N-glycopeptides at the proteome scale.
Journal Article
Improving mass spectrometry analysis of protein structures with arginine-selective chemical cross-linkers
2019
Chemical cross-linking of proteins coupled with mass spectrometry analysis (CXMS) is widely used to study protein-protein interactions (PPI), protein structures, and even protein dynamics. However, structural information provided by CXMS is still limited, partly because most CXMS experiments use lysine-lysine (K-K) cross-linkers. Although superb in selectivity and reactivity, they are ineffective for lysine deficient regions. Herein, we develop aromatic glyoxal cross-linkers (ArGOs) for arginine-arginine (R-R) cross-linking and the lysine-arginine (K-R) cross-linker KArGO. The R-R or K-R cross-links generated by ArGO or KArGO fit well with protein crystal structures and provide information not attainable by K-K cross-links. KArGO, in particular, is highly valuable for CXMS, with robust performance on a variety of samples including a kinase and two multi-protein complexes. In the case of the CNGP complex, KArGO cross-links covered as much of the PPI interface as R-R and K-K cross-links combined and improved the accuracy of Rosetta docking substantially.
Cross-linking mass spectrometry can provide insights into protein structures and interactions but its scope depends on the reactivity of the cross-linker. Here, the authors develop Arg-Arg and Lys-Arg cross-linkers, which provide structural information elusive to the widely used Lys-Lys cross-linkers.
Journal Article
Identification of cross-linked peptides from complex samples
2012
pLink, software for data analysis of cross-linked proteins coupled with mass spectrometry, estimates false discovery rate and enables analysis of protein complexes without extensive purification.
We have developed pLink, software for data analysis of cross-linked proteins coupled with mass-spectrometry analysis. pLink reliably estimates false discovery rate in cross-link identification and is compatible with multiple homo- or hetero-bifunctional cross-linkers. We validated the program with proteins of known structures, and we further tested it on protein complexes, crude immunoprecipitates and whole-cell lysates. We show that it is a robust tool for protein-structure and protein-protein–interaction studies.
Journal Article
Trifunctional cross-linker for mapping protein-protein interaction networks and comparing protein conformational states
2016
To improve chemical cross-linking of proteins coupled with mass spectrometry (CXMS), we developed a lysine-targeted enrichable cross-linker containing a biotin tag for affinity purification, a chemical cleavage site to separate cross-linked peptides away from biotin after enrichment, and a spacer arm that can be labeled with stable isotopes for quantitation. By locating the flexible proteins on the surface of 70S ribosome, we show that this trifunctional cross-linker is effective at attaining structural information not easily attainable by crystallography and electron microscopy. From a crude Rrp46 immunoprecipitate, it helped identify two direct binding partners of Rrp46 and 15 protein-protein interactions (PPIs) among the co-immunoprecipitated exosome subunits. Applying it to E. coli and C. elegans lysates, we identified 3130 and 893 inter-linked lysine pairs, representing 677 and 121 PPIs. Using a quantitative CXMS workflow we demonstrate that it can reveal changes in the reactivity of lysine residues due to protein-nucleic acid interaction. Proteins fold into structures that are determined by the order of the amino acids that they are built from. These structures enable the protein to carry out its role, which often involves interacting with other proteins. Chemical cross-linking coupled with mass spectrometry (CXMS) is a powerful method used to study protein structure and how proteins interact, with a benefit of stabilizing and capturing brief interactions. CXMS uses a chemical compound called a linker that has two arms, each of which can bind specific amino acids in a protein or in multiple proteins. Only when the regions are close to each other can they be “cross-linked” in this way. After cross-linking, the proteins are cut into small pieces known as peptides. The cross-linked peptides are then separated from the non cross-linked ones and characterized. Although CXMS is a popular method, there are aspects about it that limit its use. It does not work well on complex samples that contain lots of different proteins, as it is difficult to separate the cross-linked peptides from the overwhelming amounts of non cross-linked peptides. Also, although it can be used to detect changes in the shape of a protein, which are often crucial to the protein's role, the method has not been smoothed out. Tan, Li et al. have now developed a new cross-linker called Leiker that addresses these limitations. Leiker cross-links the amino acid lysine to another lysine, and contains a molecular tag that allows cross-linked peptides to be efficiently purified away from non cross-linked peptides. As part of a streamlined workflow to detect changes in the shape of a protein, Leiker also contains a region that can be labeled. Analysing a bacterial ribosome, which contains more than 50 proteins, showed that Leiker-based CXMS could detect many more protein interactions than previous studies had. These included interactions that changed too rapidly to be studied by other structural methods. Tan, Li et al. then applied Leiker-based CXMS to the entire contents of bacterial cells at different stages of growth, and identified a protein interaction that is only found in growing cells. In future, Leiker will be useful for analyzing the structure of large protein complexes, probing changes in protein structure, and mapping the interactions between proteins in complex mixtures.
Journal Article
pGlyco: a pipeline for the identification of intact N-glycopeptides by using HCD- and CID-MS/MS and MS3
2016
Confident characterization of the microheterogeneity of protein glycosylation through identification of intact glycopeptides remains one of the toughest analytical challenges for glycoproteomics. Recently proposed mass spectrometry (MS)-based methods still have some defects such as lack of the false discovery rate (FDR) analysis for the glycan identification and lack of sufficient fragmentation information for the peptide identification. Here we proposed pGlyco, a novel pipeline for the identification of intact glycopeptides by using complementary MS techniques: 1) HCD-MS/MS followed by product-dependent CID-MS/MS was used to provide complementary fragments to identify the glycans and a novel target-decoy method was developed to estimate the false discovery rate of the glycan identification; 2) data-dependent acquisition of MS3 for some most intense peaks of HCD-MS/MS was used to provide fragments to identify the peptide backbones. By integrating HCD-MS/MS, CID-MS/MS and MS3, intact glycopeptides could be confidently identified. With pGlyco, a standard glycoprotein mixture was analyzed in the Orbitrap Fusion and 309 non-redundant intact glycopeptides were identified with detailed spectral information of both glycans and peptides.
Journal Article
Microfluidic preparation of surfactant-free ultrafine DAAF with tunable particle size for insensitive initiator explosives
2024
High purity and ultrafine DAAF (u-DAAF) is an emerging insensitive charge in initiators. Although there are many ways to obtain u-DAAF, developing a preparation method with stable operation, accurate control, good quality consistency, equipment miniaturization, and minimum manpower is an inevitable requirement to adapt to the current social technology development trend. Here reported is the microfluidic preparation of u-DAAF with tunable particle size by a passive swirling microreactor. Under the guidance of recrystallization growth kinetics and mixing behavior of fluids in the swirling microreactor, the key parameters (liquid flow rate, explosive concentration and crystallization temperature) were screened and optimized through screening experiments. Under the condition that no surfactant is added and only experimental parameters are controlled, the particle size of recrystallized DAAF can be adjusted from 98 nm to 785 nm, and the corresponding specific surface area is 8.45 m2·g−1 to 1.33 m2·g−1. In addition, the preparation method has good batch stability, high yield (90.8%–92.6%) and high purity (99.0%–99.4%), indicating a high practical application potential. Electric explosion derived flyer initiation tests demonstrate that the u-DAAF shows an initiation sensitivity much lower than that of the raw DAAF, and comparable to that of the refined DAAF by conventional spraying crystallization method. This study provides an efficient method to fabricate u-DAAF with narrow particle size distribution and high reproducibility as well as a theoretical reference for fabrication of other ultrafine explosives.
Journal Article
Comprehensive identification of peptides in tandem mass spectra using an efficient open search engine
2018
Peptide identification in proteomics data is improved using an efficient open search engine.
We present a sequence-tag-based search engine, Open-pFind, to identify peptides in an ultra-large search space that includes coeluting peptides, unexpected modifications and digestions. Our method detects peptides with higher precision and speed than seven other search engines. Open-pFind identified 70–85% of the tandem mass spectra in four large-scale datasets and 14,064 proteins, each supported by at least two protein-unique peptides, in a human proteome dataset.
Journal Article
Nematode sperm maturation triggered by protease involves sperm-secreted serine protease inhibitor (Serpin)
2012
Spermiogenesis is a series of poorly understood morphological, physiological and biochemical processes that occur during the transition of immotile spermatids into motile, fertilization-competent spermatozoa. Here, we identified a Serpin (serine protease inhibitor) family protein (As_SRP-1) that is secreted from spermatids during nematode Ascaris suum spermiogenesis (also called sperm activation) and we showed that As_SRP-1 has two major functions. First, As_SRP-1 functions in cis to support major sperm protein (MSP)-based cytoskeletal assembly in the spermatid that releases it, thereby facilitating sperm motility acquisition. Second, As_SRP-1 released from an activated sperm inhibits, in trans, the activation of surrounding spermatids by inhibiting vas deferens-derived As_TRY-5, a trypsin-like serine protease necessary for sperm activation. Because vesicular exocytosis is necessary to create fertilization-competent sperm in many animal species, components released during this process might be more important modulators of the physiology and behavior of surrounding sperm than was previously appreciated.
Journal Article