Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
11
result(s) for
"Simões, Rodrigo Polaquini"
Sort by:
Cardiovascular Variability Analysis and Baroreflex Estimation in Patients with Type 2 Diabetes in Absence of Any Manifest Neuropathy
by
Simões, Rodrigo Polaquini
,
de Moura-Tonello, Sílvia Cristina Garcia
,
Marchi, Andrea
in
Adult
,
Aged
,
Analysis
2016
Indexes derived from spontaneous heart period (HP) and systolic arterial pressure (SAP) fluctuations can detect autonomic dysfunction in individuals with type 2 diabetes mellitus (DM) associated to cardiovascular autonomic neuropathy (CAN) or other neuropathies. It is unknown whether HP and SAP variability indexes are sensitive enough to detect the autonomic dysfunction in DM patients without CAN and other neuropathies.
We evaluated 68 males aged between 40 and 65 years. The group was composed by DM type 2 DM with no manifest neuropathy (n = 34) and healthy (H) subjects (n = 34). The protocol consisted of 15 minutes of recording of HP and SAP variabilities at rest in supine position (REST) and after active standing (STAND). The HP power in the high frequency band (HF, from 0.15 to 0.5 Hz), the SAP power in the low frequency band (LF, from 0.04 to 0.15 Hz) and BRS estimated via spectral approach and sequence method were computed.
The HF power of HP was lower in DM patients than in H subjects, while the two groups exhibited comparable HF power of HP during STAND. The LF power of SAP was similar in DM and H groups at REST and increased during STAND in both groups. BRSs estimated in the HF band and via baroreflex sequence method were lower in DM than in H and they decreased further during STAND in both populations.
Results suggest that vagal control of heart rate and cardiac baroreflex control was impaired in type 2 DM, while sympathetic control directed to vessels, sympathetic and baroreflex response to STAND were preserved. Cardiovascular variability indexes are sensitive enough to typify the early, peculiar signs of autonomic dysfunction in type-2 DM patients well before CAN becomes manifest.
Journal Article
Effect of Systemic and Auricular Acupuncture with a 2/100 Hz Frequency and Nogier Frequency in Fibromyalgia: a Randomized Clinical Trial, Pilot Study
by
Simões, Rodrigo Polaquini
,
de Lima, Rosana Aparecida
,
da Silva, Karol Priscila
in
Acupuncture
,
Analgesics
,
Clinical trials
2023
Background
Fibromyalgia is a syndrome of chronic, generalized muscular pain, accompanied by sleep disturbances, fatigue and cardic autonomic dysfunction that will affect the quality of life. There is currently no gold standard treatment. There are limitations of studies with electroacupuncture in auricular acupuncture.
Objectives
We evaluate the effects of systemic electroacupuncture (EA) with frequencies of 2/100 Hz associated of auricular acupuncture with a Nogier frequency (2.28, 4.56 and 9.12 Hz) for pain intensity, heart rate variability (HRV), and quality of life in fibromyalgia.
Methods
Randomized clinical trial, a pilot study. Eighteen volunteers were randomized into a control group (CG, n = 9) and an experimental group (EG, n = 9). Six systemic EA sessions systemic and auricular were applied in the EG for 20 min, twice a week, for six weeks consecutive. The Numerical Pain Assessment Scale (NPRS), 2010 diagnostic criteria of the American College of Rheumatology (FDC 2010), Fibromyalgia Impact Questionnaire (FIQ) and analysis of HRV were the instruments used. The independent t-test compared to the groups was applied.
Results
There was no statistically significant difference for the primary outcome for NPRS (
p
> 0.05). In the secondary outcome there was a significant difference in the total score and in some FIQ domains (
p
= 0.008) and some variables such as pain (
p
= 0.02) and anxiety (
p
= 0.006). There was no significant difference for the FDC 2010 and HRV variables (
p
> 0.05).
Conclusion
2/100 Hz systemic EA associated with the Nogier frequency positively influenced some quality of life variables; however, pain intensity, diagnostic criteria, and HRV variables did not change.
Journal Article
Correction: Cardiovascular Variability Analysis and Baroreflex Estimation in Patients with Type 2 Diabetes in Absence of Any Manifest Neuropathy
by
de Oliveira Gois, Mariana
,
Simões, Rodrigo Polaquini
,
de Moura-Tonello, Sílvia Cristina Garcia
in
Baroreceptors
,
Diabetes
,
Diabetes mellitus
2017
All relevant data are available on the Dryad repository (http://dx.doi.org/10.5061/dryad.5d8jv). (2016) Cardiovascular Variability Analysis and Baroreflex Estimation in Patients with Type 2 Diabetes in Absence of Any Manifest Neuropathy.
Journal Article
Expiratory Flow Limitation at Different Exercise Intensities in Coronary Artery Disease
by
Silva, Ester
,
Karsten, Marlus
,
Simões, Rodrigo Polaquini
in
Anaerobic threshold
,
Angioplasty
,
Cardiac patients
2020
Introduction. Expiratory flow limitation (EFL) during moderate intensity exercise is present in patients with myocardial infarction (MI), whereas in healthy subjects it occurs only at a high intensity. However, it is unclear whether this limitation already manifests in those with stable coronary artery disease (CAD) (without MI). Materials and Methods. Forty-one men aged 40–65 years were allocated into (1) recent MI (RMI) group (n = 8), (2) late MI (LMI) group (n = 12), (3) stable CAD group (n = 9), and (4) healthy control group (CG) (n = 12). All participants underwent two cardiopulmonary exercise tests at a constant workload (moderate and high intensity), and EFL was evaluated at the end of each exercise workload. Results. During moderate intensity exercise, the RMI and LMI groups presented with a significantly higher number of participants with EFL compared to the CG (p<0.05), while no significant difference was observed among groups at high intensity exercise (p>0.05). Moreover, EFL was only present in MI groups during moderate intensity exercise, whereas at high intensity all groups presented EFL. Regarding the degree of EFL, the RMI and LMI groups showed significantly higher values at moderate intensity exercise in relation to the CG. At high intensity exercise, significantly higher values for the degree of EFL were observed only in the LMI group. Conclusion. The ventilatory limitation at moderate intensity exercise may be linked to the pulmonary consequences of the MI, even subjects with preserved cardiac and pulmonary function at rest, and not to CAD per se.
Journal Article
Impact of Aerobic Exercise Training on Heart Rate Variability and Functional Capacity in Obese Women After Gastric Bypass Surgery
by
Simões, Rodrigo Polaquini
,
Catai, Aparecida Maria
,
Arena, Ross
in
Adult
,
Body mass index
,
Clinical Research
2011
Background
Obesity is a major public health concern on a global scale. Bariatric surgery is among the treatment options, resulting in significant and sustainable weight loss as well as amelioration of comorbidities. The purpose of this study was to evaluate whether a 12-week aerobic exercise program positively impacts heart rate variability (HRV) and functional capacity after gastric bypass surgery (GBS) in a female cohort.
Methods
Of the 52 patients initially recruited, 21 were randomized to a training group (TG) or control group and successfully completed the study. Patients were tested on two occasions: 1 week before GBS and 4 months after GBS. Anthropometric variables, body composition, record of heart rate and R-R intervals, and 6-min walk test (6MWT) were assessed at both time points. The TG underwent an aerobic exercise training program on a treadmill (1-h session, totaling 36 sessions over 12 weeks).
Results
The main findings from this study were: (1) only the TG demonstrated a significant increase (
p
< 0.05) in all indexes of heart rate variability (HRV) after 12 weeks of aerobic exercise training and (2) only the TG demonstrated a significant increase (
p
< 0.05) in 6MWT distance and decrease in diastolic blood pressure after aerobic exercise training.
Conclusions
We conclude that 12 weeks of aerobic exercise training improves cardiac autonomic modulation and functional capacity 4 months after GBS.
Journal Article
High-intensity inspiratory protocol increases heart rate variability in myocardial revascularization patients
by
Simões, Rodrigo Polaquini
,
Reis, Michel Silva
,
Silva, Audrey Borghi
in
Aged
,
Analysis of Variance
,
Autonomic Nervous System
2016
To evaluate heart rate variability during an inspiratory muscle endurance protocol at three different load levels [30%, 60% and 80% of maximal inspiratory pressure], in patients who had previously undergone coronary artery bypass grafting.
Nineteen late postoperative myocardial revascularization patients participating in a cardiovascular rehabilitation program were studied. Maximal inspiratory pressure maneuvers were performed. An inspiratory muscle endurance protocol at 30%, 60% and 80% of maximal inspiratory pressure was applied for four minutes each, in random order. Heart rate and RR intervals were recorded and heart rate variability was analyzed by time (RMSSD-the mean of the standard deviations for all R-R intervals, and RMSM-root-mean square differences of successive R-R intervals) and frequency domains indices (high and low frequency) in normalized units. ANOVA for repeated measurements was used to compare heart rate variability indices and Student t-test was used to compare the maximal inspiratory pressure and maximal expiratory pressure values.
Heart rate increased during performance of maximal respiratory pressures maneuvers, and the maximal inspiratory pressure and maximal expiratory pressure mean values were significantly lower than predicted values (P <0.05). RMSSD increased significantly at 80% in relation to rest and 30% of maximal inspiratory pressure and RMSM decreased at 30% and 60% of maximal inspiratory pressure in relation to rest (P <0.05). Additionally, there was significant and progressive decrease in low frequency and increase in high frequency at 30%, 60% and 80% of maximal inspiratory pressure in relation to the resting condition.
These results suggest that respiratory muscle training at high intensities can promote greater parasympathetic activity and it may confer important benefits during a rehabilitation program in post-coronary artery bypass grafting.
Journal Article
The additional impact of type 2 diabetes on baroreflex sensitivity of coronary artery disease patients might be undetectable in presence of deterioration of mechanical vascular properties
by
Simões, Rodrigo Polaquini
,
Porta, Alberto
,
Hirakawa, Humberto Sadanobu
in
Autonomic nervous system
,
Baroreceptors
,
Blood pressure
2019
Both deterioration of the mechanical vascular properties of barosensitive vessels and autonomic derangement lead to modification of baroreflex sensitivity (BRS) in coronary artery disease (CAD) individuals. Type 2 diabetes (T2D) reduces BRS as well even in absence of cardiac autonomic neuropathy. The aim of the study is to clarify whether, assigned the degree of mechanical vascular impairment and without cardiac autonomic neuropathy, the additional autonomic dysfunction imposed in CAD patients by T2D (CAD-T2D) decreases BRS further. We considered CAD (n = 18) and CAD-T2D (n = 19) males featuring similar increases of average carotid intima media thickness (ACIMT) and we compared them to age- and gender-matched healthy (H, n = 19) subjects. BRS was computed from spontaneous beat-to-beat variability of heart period (HP) and systolic arterial pressure (SAP) at supine resting (REST) and during active standing (STAND). BRS was estimated via methods including time domain, spectral, cross-spectral, and model-based techniques. We found that (i) at REST BRS was lower in CAD and CAD-T2D groups than in H subjects but no difference was detected between CAD and CAD-T2D individuals; (ii) STAND induced an additional decrease of BRS visible in all the groups but again BRS estimates of CAD and CAD-T2D patients were alike; (iii) even though with different statistical power, BRS markers reached similar conclusions with the notable exception of the BRS computed via model-based approach that did not detect the BRS decrease during STAND. In presence of a mechanical vascular impairment, indexes estimating BRS from spontaneous HP and SAP fluctuations might be useless to detect the additional derangement of the autonomic control in CAD-T2D without cardiac autonomic neuropathy compared to CAD, thus limiting the applications of cardiovascular variability analysis to typify CAD-T2D individuals.
Journal Article
Mitigating chronic respiratory disease through the lens of multimorbidity: the MARES mixed-methods study protocol
by
Pires Di Lorenzo, Valéria A
,
Franco, Francisco José Barbosa Zörrer
,
Souza, João Victor Rolim
in
Asthma
,
Asthma - diagnosis
,
Asthma - epidemiology
2026
IntroductionChronic respiratory diseases (CRDs), such as asthma and chronic obstructive pulmonary disease (COPD), are among the leading non-communicable diseases (NCDs) worldwide. However, diagnosing CRDs in low-income and middle-income countries (LMICs) remains challenging due to limited access to spirometry and trained professionals. Aggravating the burden, CRDs often coexist with other NCDs, increasing healthcare costs, reducing quality of life and elevating mortality. These challenges highlight the need for simple case-finding approaches for CRDs, such as the COPD in Low-Income and Middle-Income Countries Assessment (COLA-6) questionnaire, to support prompt identification and appropriate care within NCD services in LMICs.ObjectiveTo evaluate the discriminative accuracy, feasibility and implementation of the COLA-6 questionnaire in identifying and managing CRDs in Brazilian Primary Healthcare (PHC) services for NCDs.Methods and analysisThe Multimorbidity Approach for REspiratory Solutions (MARES) study consists of three work packages to be conducted in PHC services in São Carlos/SP and São Paulo/SP, Brazil.MARES-1: A cross-sectional observational study enrolling 859 individuals with at least one NCD receiving care in PHC. The COLA-6 questionnaire will be administered by the research team and compared with quality-assured spirometry. The Chronic Airways Assessment Test (CAAT), Asthma Control Questionnaire (ACQ-7) and fractional exhaled nitric oxide (FeNO) will also be assessed. The diagnostic performance of COLA-6 for identifying CRDs—including COPD, asthma, preserved ratio impaired spirometry, restriction and overlaps—will be assessed using area under receiver operating characteristic curves and 95% CIs.MARES-2: A cross-sectional observational study enrolling 20 healthcare professionals (physicians, physiotherapists, community health agents and nurses) from five PHC services. These professionals will apply the COLA-6 during routine NCD care to a total sample of 1000 patients. Qualitative interviews will be conducted to explore barriers and facilitators to the implementation of COLA-6, using deductive thematic analysis.MARES-3: A longitudinal, prospective observational study in which patients from MARES-1 and MARES-2 will be reassessed at 6-month follow-up. A total sample of 473 participants with abnormal spirometry, a diagnosis of CRD or high risk for CRDs is expected. Participants will undergo spirometry, and a subset will be interviewed to explore their healthcare experiences through qualitative thematic analysis. Access to diagnostic and treatment services in Brazil will be assessed. Changes in spirometry values, FeNO, CAAT and ACQ-7 scores from baseline to 6 months in patients from MARES-1 will be analysed.Ethics and disseminationThis study has been approved by the Ethics Committees of Federal University of São Carlos and University of Santo Amaro (UNISA). Ethical approval was also granted by the University College London. Results will be disseminated through peer-reviewed medical journals and presentations at international conferences. Results will improve identification of CRDs, addressing a significant gap in current PHC settings.Trial registration numberNCT07050823/NCT07093021/NCT07134855.
Journal Article
Heart rate variability and surface electromyography of trained cyclists at different cadences
by
Silva, Ester
,
Simões, Rodrigo Polaquini
,
Menegon, Fabrício Augusto
in
Original Article
,
SPORT SCIENCES
2016
The heart rate variability (HRV) and surface electromyography (sEMG) are important tools in the evaluation of cardiac autonomic system and neuromuscular parameters, respectively. The aim of the study was to evaluate the behavior of HRV and sEMG of the vastus lateralis in two exercise protocols on a cycle ergometer at 60 and 80 rpm. Eight healthy men cyclists who have trained for at least two years were evaluated. Reduction was observed followed by stabilization of RMSSD and SDNN indices of HRV (p<0.05) along with increases in the amplitude of the sEMG signal (p<0.05) in both protocols. Significant correlations were observed between the responses of HRV and sEMG in the cadence of 60 rpm (RMSSD and sEMG: r = -0.42, p=0.03; SDNN and sEMG: r = -0.45, p=0.01) and 80 rpm (RMSSD and sEMG: r = -0.47, p=0.02; SDNN and sEMG: r = -0.49, p=0.01), yet no difference was observed for these variables between the two protocols. We concluded that the parasympathetic cardiac responses and sEMG are independent of cadences applied at the same power output.
Journal Article
Heart rate variability and surface electromyography of trained cyclists at different cadences/Variabilidade da frequência cardíaca e eletromiografia de superfície em ciclistas treinados em diferentes cadências
The heart rate variability (HRV) and surface electromyography (sEMG) are important tools in the evaluation of cardiac autonomic system and neuromuscular parameters, respectively. The aim of the study was to evaluate the behavior of HRV and sEMG of the vastus lateralis in two exercise protocols on a cycle ergometer at 60 and 80 rpm. Eight healthy men cyclists who have trained for at least two years were evaluated. Reduction was observed followed by stabilization of RMSSD and SDNN indices of HRV (p<0.05) along with increases in the amplitude of the sEMG signal (p<0.05) in both protocols. Significant correlations were observed between the responses of HRV and sEMG in the cadence of 60 rpm (RMSSD and sEMG: r = -0.42, p=0.03; SDNN and sEMG: r = -0.45, p=0.01) and 80 rpm (RMSSD and sEMG: r = -0.47, p=0.02; SDNN and sEMG: r = -0.49, p=0.01), yet no difference was observed for these variables between the two protocols. We concluded that the parasympathetic cardiac responses and sEMG are independent of cadences applied at the same power output.
Journal Article