Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
33
result(s) for
"Smart, Sean C."
Sort by:
Cardio-Respiratory synchronized bSSFP MRI for high throughput in vivo lung tumour quantification
by
Gomes, Ana L.
,
Kinchesh, Paul
,
Ryan, Anderson J.
in
Acquisitions & mergers
,
Animal models
,
Animals
2019
The identification and measurement of tumours is a key requirement in the study of tumour development in mouse models of human cancer. Disease burden in autochthonous tumours, such as those arising in the lung, can be seen with non-invasive imaging, but cannot be accurately measured using standard tools such as callipers. Lung imaging is further complicated in the mouse due to instabilities arising from the rapid but cyclic cardio-respiratory motions, and the desire to use free-breathing animals. Female A/JOlaHsd mice were either injected (i.p.) with PBS 0.1ml/10g body weight (n = 6), or 10% urethane/PBS 0.1ml/10g body weight (n = 12) to induce autochthonous lung tumours. Cardio-respiratory synchronised bSSFP MRI, at 200 μm isotropic resolution was performed at 8, 13 and 18 weeks post induction. Images from the same mouse at different time points were aligned using threshold-based segmented masks of the lungs (ITK-SNAP and MATLAB) and tumour volumes were determined via threshold-based segmentation (ITK-SNAP).Scan times were routinely below 10 minutes and tumours were readily identifiable. Image registration allowed serial measurement of tumour volumes as small as 0.056 mm3. Repetitive imaging did not lead to mouse welfare issues. We have developed a motion desensitised scan that enables high sensitivity MRI to be performed with high throughput capability of greater than 4 mice/hour. Image segmentation and registration allows serial measurement of individual, small tumours. This allows fast and highly efficient volumetric lung tumour monitoring in cohorts of 30 mice per imaging time point. As a result, adaptive trial study designs can be achieved, optimizing experimental and welfare outcomes.
Journal Article
An MRI-Compatible High Frequency AC Resistive Heating System for Homeothermic Maintenance in Small Animals
by
Gomes, Ana L.
,
Kinchesh, Paul
,
Gilchrist, Stuart
in
Alternating current
,
Anesthesia
,
Animal sciences
2016
To develop an MRI-compatible resistive heater, using high frequency alternating current (AC), for temperature maintenance of anaesthetised animals.
An MRI-compatible resistive electrical heater was formed from narrow gauge wire connected to a high frequency (10-100 kHz) AC power source. Multiple gradient echo images covering a range of echo times, and pulse-acquire spectra were acquired with the wire heater powered using high frequency AC or DC power sources and without any current flowing in order to assess the sensitivity of the MRI acquisitions to the presence of current flow through the heater wire. The efficacy of temperature maintenance using the AC heater was assessed by measuring rectal temperature immediately following induction of general anaesthesia for a period of 30 minutes in three different mice.
Images and spectra acquired in the presence and absence of 50-100 kHz AC through the wire heater were indistinguishable, whereas DC power created field shifts and lineshape distortions. Temperature lost during induction of anaesthesia was recovered within approximately 20 minutes and a stable temperature was reached as the mouse's temperature approached the set target.
The AC-powered wire heater maintains adequate heat input to the animal to maintain body temperature, and does not compromise image quality.
Journal Article
An efficient and robust MRI-guided radiotherapy planning approach for targeting abdominal organs and tumours in the mouse
by
Gomes, Ana L.
,
Kinchesh, Paul
,
Bird, Luke
in
Abdomen - diagnostic imaging
,
Abdomen - radiation effects
,
Abdominal cancer
2017
Preclinical CT-guided radiotherapy platforms are increasingly used but the CT images are characterized by poor soft tissue contrast. The aim of this study was to develop a robust and accurate method of MRI-guided radiotherapy (MR-IGRT) delivery to abdominal targets in the mouse.
A multimodality cradle was developed for providing subject immobilisation and its performance was evaluated. Whilst CT was still used for dose calculations, target identification was based on MRI. Each step of the radiotherapy planning procedure was validated initially in vitro using BANG gel dosimeters. Subsequently, MR-IGRT of normal adrenal glands with a size-matched collimated beam was performed. Additionally, the SK-N-SH neuroblastoma xenograft model and the transgenic KPC model of pancreatic ductal adenocarcinoma were used to demonstrate the applicability of our methods for the accurate delivery of radiation to CT-invisible abdominal tumours.
The BANG gel phantoms demonstrated a targeting efficiency error of 0.56 ± 0.18 mm. The in vivo stability tests of body motion during MR-IGRT and the associated cradle transfer showed that the residual body movements are within this MR-IGRT targeting error. Accurate MR-IGRT of the normal adrenal glands with a size-matched collimated beam was confirmed by γH2AX staining. Regression in tumour volume was observed almost immediately post MR-IGRT in the neuroblastoma model, further demonstrating accuracy of x-ray delivery. Finally, MR-IGRT in the KPC model facilitated precise contouring and comparison of different treatment plans and radiotherapy dose distributions not only to the intra-abdominal tumour but also to the organs at risk.
This is, to our knowledge, the first study to demonstrate preclinical MR-IGRT in intra-abdominal organs. The proposed MR-IGRT method presents a state-of-the-art solution to enabling robust, accurate and efficient targeting of extracranial organs in the mouse and can operate with a sufficiently high throughput to allow fractionated treatments to be given.
Journal Article
Hypoxia Imaging Using PET and SPECT: The Effects of Anesthetic and Carrier Gas on 64Cu-ATSM, 99mTc-HL91 and 18F-FMISO Tumor Hypoxia Accumulation
by
Hueting, Rebekka
,
Muschel, Ruth J.
,
Tredwell, Matthew
in
Adenocarcinoma - diagnosis
,
Adenocarcinoma - drug therapy
,
Adenocarcinoma - metabolism
2011
Preclinical imaging requires anaesthesia to reduce motion-related artefacts. For direct translational relevance, anaesthesia must not significantly alter experimental outcome. This study reports on the effects of both anaesthetic and carrier gas upon the uptake of [⁶⁴Cu]-CuATSM, [(⁹⁹m)Tc]-HL91 and [¹⁸F]-FMISO in a preclinical model of tumor hypoxia.
The effect of carrier gas and anaesthetic was studied in 6 groups of CaNT-bearing CBA mice using [⁶⁴Cu]-CuATSM, [(⁹⁹m)Tc]-HL91 or [¹⁸F]-FMISO. Mice were anaesthetised with isoflurane in air, isoflurane in pure oxygen, with ketamine/xylazine or hypnorm/hypnovel whilst breathing air, or in the awake state whilst breathing air or pure oxygen. PET or SPECT imaging was performed after which the mice were killed for organ/tumor tracer quantitation. Tumor hypoxia was confirmed. Arterial blood gas analysis was performed for the different anaesthetic regimes. The results demonstrate marked influences on tumor uptake of both carrier gas and anaesthetic, and show differences between [(99m)Tc]-HL91, [¹⁸F]-FMISO and [⁶⁴Cu]-CuATSM. [(⁹⁹m)Tc]-HL91 tumor uptake was only altered significantly by administration of 100% oxygen. The latter was not the case for [¹⁸F]-FMISO and [⁶⁴Cu]-CuATSM. Tumor-to-muscle ratio (TMR) for both compounds was reduced significantly when either oxygen or anaesthetics (isoflurane in air, ketamine/xylazine or hypnorm/hypnovel) were introduced. For [¹⁸F]-FMISO no further decrease was measured when both isoflurane and oxygen were administered, [⁶⁴Cu]-CuATSM did show an additional significant decrease in TMR. When using the same anaesthetic regimes, the extent of TMR reduction was less pronounced for [⁶⁴Cu]-CuATSM than for [¹⁸F]-FMISO (40-60% versus 70% reduction as compared to awake animals breathing air).
The use of anaesthesia can have profound effects on the experimental outcome. More importantly, all tested anaesthetics reduced tumor-hypoxia uptake. Anaesthesia cannot be avoided in preclinical studies but great care has to be taken in preclinical models of hypoxia as anaesthesia effects cannot be generalised across applications, nor disease states.
Journal Article
Improving In Vivo High-Resolution CT Imaging of the Tumour Vasculature in Xenograft Mouse Models through Reduction of Motion and Bone-Streak Artefacts
by
Kinchesh, Paul
,
Kersemans, Veerle
,
Bates, Russell
in
Adenocarcinoma - blood supply
,
Adenocarcinoma - diagnostic imaging
,
Adenocarcinoma - pathology
2015
Preclinical in vivo CT is commonly used to visualise vessels at a macroscopic scale. However, it is prone to many artefacts which can degrade the quality of CT images significantly. Although some artefacts can be partially corrected for during image processing, they are best avoided during acquisition. Here, a novel imaging cradle and tumour holder was designed to maximise CT resolution. This approach was used to improve preclinical in vivo imaging of the tumour vasculature.
A custom built cradle containing a tumour holder was developed and fix-mounted to the CT system gantry to avoid artefacts arising from scanner vibrations and out-of-field sample positioning. The tumour holder separated the tumour from bones along the axis of rotation of the CT scanner to avoid bone-streaking. It also kept the tumour stationary and insensitive to respiratory motion. System performance was evaluated in terms of tumour immobilisation and reduction of motion and bone artefacts. Pre- and post-contrast CT followed by sequential DCE-MRI of the tumour vasculature in xenograft transplanted mice was performed to confirm vessel patency and demonstrate the multimodal capacity of the new cradle. Vessel characteristics such as diameter, and branching were quantified.
Image artefacts originating from bones and out-of-field sample positioning were avoided whilst those resulting from motions were reduced significantly, thereby maximising the resolution that can be achieved with CT imaging in vivo. Tumour vessels ≥ 77 μm could be resolved and blood flow to the tumour remained functional. The diameter of each tumour vessel was determined and plotted as histograms and vessel branching maps were created. Multimodal imaging using this cradle assembly was preserved and demonstrated.
The presented imaging workflow minimised image artefacts arising from scanner induced vibrations, respiratory motion and radiopaque structures and enabled in vivo CT imaging and quantitative analysis of the tumour vasculature at higher resolution than was possible before. Moreover, it can be applied in a multimodal setting, therefore combining anatomical and dynamic information.
Journal Article
Tumour irradiation combined with vascular-targeted photodynamic therapy enhances antitumour effects in pre-clinical prostate cancer
by
Rittscher, Jens
,
Lockett, Stephen J.
,
Chatrian, Andrea
in
631/67/1059/485
,
692/4028/546
,
Allografts
2021
Background
There is a need to improve the treatment of prostate cancer (PCa) and reduce treatment side effects. Vascular-targeted photodynamic therapy (VTP) is a focal therapy for low-risk low-volume localised PCa, which rapidly disrupts targeted tumour vessels. There is interest in expanding the use of VTP to higher-risk disease. Tumour vasculature is characterised by vessel immaturity, increased permeability, aberrant branching and inefficient flow. FRT alters the tumour microenvironment and promotes transient ‘vascular normalisation’. We hypothesised that multimodality therapy combining fractionated radiotherapy (FRT) and VTP could improve PCa tumour control compared against monotherapy with FRT or VTP.
Methods
We investigated whether sequential delivery of FRT followed by VTP 7 days later improves flank TRAMP-C1 PCa tumour allograft control compared to monotherapy with FRT or VTP.
Results
FRT induced ‘vascular normalisation’ changes in PCa flank tumour allografts, improving vascular function as demonstrated using dynamic contrast-enhanced magnetic resonance imaging. FRT followed by VTP significantly delayed tumour growth in flank PCa allograft pre-clinical models, compared with monotherapy with FRT or VTP, and improved overall survival.
Conclusion
Combining FRT and VTP may be a promising multimodal approach in PCa therapy. This provides proof-of-concept for this multimodality treatment to inform early phase clinical trials.
Journal Article
Micro-CT for Anatomic Referencing in PET and SPECT: Radiation Dose, Biologic Damage, and Image Quality
by
Cornelissen, Bart
,
Kersemans, Veerle
,
Muschel, Ruth J
in
Animals
,
Cancer
,
Deoxyribonucleic acid
2011
CT is widely used for anatomic referencing of PET and SPECT images of small animals but requires sufficiently high radiation doses capable of causing significant DNA damage. Therefore, we described the relationship between radiation dose, biologic damage, and image quality to determine whether CT can be used without significantly compromising radiotherapy and tumor development studies.
The CT dose index generated by the nanoSPECT/CT system was compared with measurements using EBT2 gafchromic film. The effects of micro-CT were evaluated in 2 mouse strains that differ in sensitivity to radiation. γH2AX foci analysis to determine leukocyte, liver, and jejunum DNA damage and hematoxylin and eosin staining to investigate macroscopic jejunum damage were performed. Signal-to-noise ratio, contrast-to-noise ratio, and scanner linearity were determined to assess image quality.
For the standard settings, that is, as set by the manufacturers, EBT2 gafchromic film dosimetry showed that the nanoSPECT/CT system underestimated the absorbed dose. Moreover, significant doses were obtained, resulting in a significant increase in γH2AX formation in leukocytes, liver, and jejunum 40 min after CT, using preset parameters when compared with nonimaged controls. The jejenum response was more pronounced for the more radiosensitive strain. In contrast to leukocytes, the liver and jejunum still showed evidence of DNA damage 3 d after CT. Contrast-to-noise ratio, signal-to-noise ratio, and scanner linearity were sufficient to allow for anatomic referencing for both imaging protocols tested.
Anatomic reference images can be produced with no observable DNA damage or compromising image quality using low radiographic voltage, flux, and duration.
Journal Article
Wavelet-based cluster analysis: data-driven grouping of voxel time courses with application to perfusion-weighted and pharmacological MRI of the rat brain
by
Whitcher, Brandon
,
Barjat, Hervé
,
Grundy, Robert I.
in
Algorithms
,
Animals
,
Brain - anatomy & histology
2005
MRI time series experiments produce a wealth of information contained in two or three spatial dimensions that evolve over time. Such experiments can, for example, localize brain response to pharmacological stimuli, but frequently the spatiotemporal characteristics of the cerebral response are unknown a priori and variable, and thus difficult to evaluate using hypothesis-based methods alone. Here we used features in the temporal dimension to group voxels with similar time courses based on a nonparametric discrete wavelet transform (DWT) representation of each time course. Applying the DWT to each voxel decomposes its temporal information into coefficients associated with both time and scale. Discarding scales in the DWT that are associated with high-frequency oscillations (noise) provided a straight-forward data reduction step and decreased the computational burden. Optimization-based clustering was then applied to the remaining wavelet coefficients in order to produce a finite number of voxel clusters. This wavelet-based cluster analysis (WCA) was evaluated using two representative classes of MRI neuroimaging experiments. In perfusion-weighted MRI, following occlusion of the middle cerebral artery (MCAO), WCA differentiated healthy tissue and different regions within the ischemic hemisphere. Following an acute cocaine challenge, WCA localized subtle differences in the pharmacokinetic profile of the cerebral response. We conclude that WCA provides a robust method for blind analysis of time series image data.
Journal Article
Hypoxia imaging using PET and SPECT: the effects of anesthetic and carrier gas on Cu-ATSM, Tc-HL91 and F-FMISO tumor hypoxia accumulation
2011
Preclinical imaging requires anaesthesia to reduce motion-related artefacts. For direct translational relevance, anaesthesia must not significantly alter experimental outcome. This study reports on the effects of both anaesthetic and carrier gas upon the uptake of [⁶⁴Cu]-CuATSM, [(⁹⁹m)Tc]-HL91 and [¹⁸F]-FMISO in a preclinical model of tumor hypoxia.BACKGROUNDPreclinical imaging requires anaesthesia to reduce motion-related artefacts. For direct translational relevance, anaesthesia must not significantly alter experimental outcome. This study reports on the effects of both anaesthetic and carrier gas upon the uptake of [⁶⁴Cu]-CuATSM, [(⁹⁹m)Tc]-HL91 and [¹⁸F]-FMISO in a preclinical model of tumor hypoxia.The effect of carrier gas and anaesthetic was studied in 6 groups of CaNT-bearing CBA mice using [⁶⁴Cu]-CuATSM, [(⁹⁹m)Tc]-HL91 or [¹⁸F]-FMISO. Mice were anaesthetised with isoflurane in air, isoflurane in pure oxygen, with ketamine/xylazine or hypnorm/hypnovel whilst breathing air, or in the awake state whilst breathing air or pure oxygen. PET or SPECT imaging was performed after which the mice were killed for organ/tumor tracer quantitation. Tumor hypoxia was confirmed. Arterial blood gas analysis was performed for the different anaesthetic regimes. The results demonstrate marked influences on tumor uptake of both carrier gas and anaesthetic, and show differences between [(99m)Tc]-HL91, [¹⁸F]-FMISO and [⁶⁴Cu]-CuATSM. [(⁹⁹m)Tc]-HL91 tumor uptake was only altered significantly by administration of 100% oxygen. The latter was not the case for [¹⁸F]-FMISO and [⁶⁴Cu]-CuATSM. Tumor-to-muscle ratio (TMR) for both compounds was reduced significantly when either oxygen or anaesthetics (isoflurane in air, ketamine/xylazine or hypnorm/hypnovel) were introduced. For [¹⁸F]-FMISO no further decrease was measured when both isoflurane and oxygen were administered, [⁶⁴Cu]-CuATSM did show an additional significant decrease in TMR. When using the same anaesthetic regimes, the extent of TMR reduction was less pronounced for [⁶⁴Cu]-CuATSM than for [¹⁸F]-FMISO (40-60% versus 70% reduction as compared to awake animals breathing air).METHODOLOGY/PRINCIPAL FINDINGSThe effect of carrier gas and anaesthetic was studied in 6 groups of CaNT-bearing CBA mice using [⁶⁴Cu]-CuATSM, [(⁹⁹m)Tc]-HL91 or [¹⁸F]-FMISO. Mice were anaesthetised with isoflurane in air, isoflurane in pure oxygen, with ketamine/xylazine or hypnorm/hypnovel whilst breathing air, or in the awake state whilst breathing air or pure oxygen. PET or SPECT imaging was performed after which the mice were killed for organ/tumor tracer quantitation. Tumor hypoxia was confirmed. Arterial blood gas analysis was performed for the different anaesthetic regimes. The results demonstrate marked influences on tumor uptake of both carrier gas and anaesthetic, and show differences between [(99m)Tc]-HL91, [¹⁸F]-FMISO and [⁶⁴Cu]-CuATSM. [(⁹⁹m)Tc]-HL91 tumor uptake was only altered significantly by administration of 100% oxygen. The latter was not the case for [¹⁸F]-FMISO and [⁶⁴Cu]-CuATSM. Tumor-to-muscle ratio (TMR) for both compounds was reduced significantly when either oxygen or anaesthetics (isoflurane in air, ketamine/xylazine or hypnorm/hypnovel) were introduced. For [¹⁸F]-FMISO no further decrease was measured when both isoflurane and oxygen were administered, [⁶⁴Cu]-CuATSM did show an additional significant decrease in TMR. When using the same anaesthetic regimes, the extent of TMR reduction was less pronounced for [⁶⁴Cu]-CuATSM than for [¹⁸F]-FMISO (40-60% versus 70% reduction as compared to awake animals breathing air).The use of anaesthesia can have profound effects on the experimental outcome. More importantly, all tested anaesthetics reduced tumor-hypoxia uptake. Anaesthesia cannot be avoided in preclinical studies but great care has to be taken in preclinical models of hypoxia as anaesthesia effects cannot be generalised across applications, nor disease states.CONCLUSIONS/SIGNIFICANCEThe use of anaesthesia can have profound effects on the experimental outcome. More importantly, all tested anaesthetics reduced tumor-hypoxia uptake. Anaesthesia cannot be avoided in preclinical studies but great care has to be taken in preclinical models of hypoxia as anaesthesia effects cannot be generalised across applications, nor disease states.
Journal Article
Magnetic resonance imaging of the regenerating neonatal mouse heart
2018
We present longitudinal magnetic resonance imaging (MRI) of neonatal mouse hearts during the first three weeks following coronary artery ligation to mimic heart attack. We confirm heart regeneration in individual animals injured on post-natal day 1 (P1) while those injured on P7 show the adult response of fibrosis, scarring and impaired heart performance. We document heart growth and development of the principal functional cardiac parameters, and also remodeling during tissue regeneration as compared to fibrosis when imaging repeatedly up to 21 days after myocardial infarction (MI). We reveal compensatory changes in cardiac function with the restoration of tissue and resolution of injury for the P1 cohort and sustained injury responses for the P7 cohort. This study resolves the controversy surrounding neonatal mouse heart regeneration and establishes a functional platform for live capture of the regenerative process and for the future testing of genetic or therapeutic interventions.