Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
61 result(s) for "Smith-Jones, Peter M."
Sort by:
Noninvasive measurement of androgen receptor signaling with a positron-emitting radiopharmaceutical that targets prostate-specific membrane antigen
Despite encouraging clinical results with next generation drugs (MDV3100 and abiraterone) that inhibit androgen receptor (AR) signaling in patients with castration-resistant prostate cancer (CRPC), responses are variable and short-lived. There is an urgent need to understand the basis of resistance to optimize their future use. We reasoned that a radiopharmaceutical that measures intratumoral changes in AR signaling could substantially improve our understanding of AR pathway directed therapies. Expanding on previous observations, we first show that prostate-specific membrane antigen (PSMA) is repressed by androgen treatment in multiple models of AR-positive prostate cancer in an AR-dependent manner. Conversely, antiandrogens up-regulate PSMA expression. These expression changes, including increased PSMA expression in response to treatment with the antiandrogen MDV3100, can be quantitatively measured in vivo in human prostate cancer xenograft models through PET imaging with a fully humanized, radiolabeled antibody to PSMA, ⁶⁴Cu-J591. Collectively, these results establish that relative changes in PSMA expression levels can be quantitatively measured using a human-ready imaging reagent and could serve as a biomarker of AR signaling to noninvasively evaluate AR activity in patients with CRPC.
Development of a Second-Generation Antiandrogen for Treatment of Advanced Prostate Cancer
Metastatic prostate cancer is treated with drugs that antagonize androgen action, but most patients progress to a more aggressive form of the disease called castration-resistant prostate cancer, driven by elevated expression of the androgen receptor. Here we characterize the diarylthiohydantoins RD162 and MDV3100, two compounds optimized from a screen for nonsteroidal antiandrogens that retain activity in the setting of increased androgen receptor expression. Both compounds bind to the androgen receptor with greater relative affinity than the clinically used antiandrogen bicalutamide, reduce the efficiency of its nuclear translocation, and impair both DNA binding to androgen response elements and recruitment of coactivators. RD162 and MDV3100 are orally available and induce tumor regression in mouse models of castration-resistant human prostate cancer. Of the first 30 patients treated with MDV3100 in a Phase I/II clinical trial, 13 of 30 (43%) showed sustained declines (by >50%) in serum concentrations of prostate-specific antigen, a biomarker of prostate cancer. These compounds thus appear to be promising candidates for treatment of advanced prostate cancer.
Evolution of Bombesin Conjugates for Targeted PET Imaging of Tumors
Bombesin receptors are under intense investigation as molecular targets since they are overexpressed in several prevalent solid tumors. We rationally designed and synthesized a series of modified bombesin (BN) peptide analogs to study the influence of charge and spacers at the N-terminus, as well as amino acid substitutions, on both receptor binding affinity and pharmacokinetics. This enabled development of a novel (64/67)Cu-labeled BN peptide for PET imaging and targeted radiotherapy of BN receptor-positive tumors. Our results show that N-terminally positively charged peptide ligands had significantly higher affinity to human gastrin releasing peptide receptor (GRPr) than negatively charged or uncharged ligands (IC(50): 3.2±0.5 vs 26.3±3.5 vs 41.5±2.5 nM). The replacement of Nle(14) by Met, and deletion of D-Tyr(6), further resulted in 8-fold higher affinity. Contrary to significant changes to human GRPr binding, modifications at the N-terminal and at the 6(th), 11(th), and 14(th) position of BN induced only slight influences on affinity to mouse GRPr. [Cu(II)]-CPTA-[βAla(11)] BN(7-14) ([Cu(II)]-BZH7) showed the highest internalization rate into PC-3 cells with relatively slow efflux because of its subnanomolar affinity to GRPr. Interestingly, [(64/67)Cu]-BZH7 also displayed similar affinities to the other 2 human BN receptor subtypes. In vivo studies showed that [(64/67)Cu]-BZH7 had a high accumulation in PC-3 xenografts and allowed for clear-cut visualization of the tumor in PET imaging. In addition, a CPTA-glycine derivative, forming a hippurane-type spacer, enhanced kidney clearance of the radiotracer. These data indicate that the species variation of BN receptor plays an important role in screening radiolabeled BN. As well, the positive charge from the metallated complex at the N-terminal significantly increases affinity to human GRPr. Application of these observations enabled the novel ligand [(64/67)Cu]-BZH7 to clearly visualize PC-3 tumors in vivo. This study provides a strong starting point for optimizing radiopeptides for targeting carcinomas that express any of the BN receptor subtypes.
Molecular Targeting of Carbonic Anhydrase IX in Mice with Hypoxic HT29 Colorectal Tumor Xenografts
Carbonic anhydrase IX (CAIX) is a membrane spanning protein involved in the enzymatic regulation of tumor acid-base balance. CAIX has been shown to be elevated in a number of hypoxic tumor types. The purpose of this study was to determine the efficiency of intact and IgG fragments of cG250 to target CAIX in vivo in a hypoxic tumor model. Conventional biodistribution studies were performed with (111)In-DO3A-cG250, (111)In-DO3A-F(ab')(2)-cG250 and (111)In-DO3A-Fab-cG250. Additional ex vivo analysis of the tumor was performed with markers for tumor hypoxia, blood perfusion and endogenous CAIX expression. All four data sets were digitally correlated to determine the optimal agent for determining hypoxia in a HT29 colon cancer xenograft. The HT29 human colorectal tumor xenografts show strong CAIX expression in hypoxic areas of poor blood perfusion. The intact IgG had an initial high focal uptake at the periphery of these hypoxic regions and penetration into the areas of highest CAIX expression over the 7-day study period. The lower molecular weight antibody fragments had a faster uptake into areas of high CAIX expression, but had a much lower absolute uptake at the optimal imaging times. For the clinical detection of hypoxia induced CAIX using cG250 antibody based agents, imaging with the intact IgG at 7 days post injection would allow for the most sensitive and accurate detection of CAIX.
Utility of positron emission tomography for drug development for heart failure
Only about 1 in 5,000 investigational agents in a preclinical stage acquires Food and Drug Administration approval. Among many reasons for this includes an inefficient transition from preclinical to clinical phases, which exponentially increase the cost and the delays the process of drug development. Positron emission tomography (PET) is a nuclear imaging technique that has been used for the diagnosis, risk stratification, and guidance of therapy. However, lately with the advance of radiochemistry and of molecular imaging technology, it became evident that PET could help novel drug development process. By using a PET radioligand to report on receptor occupancy during novel agent therapy, it may help assess the effectiveness, efficacy, and safety of such a new medication in an early preclinical stage and help design successful clinical trials even at a later phase. In this article, we explore the potential implications of PET in the development of new heart failure therapies and review PET's application in the respective pathophysiologic pathways such as myocardial perfusion, metabolism, innervation, inflammation, apoptosis, and cardiac remodeling.
Complement factor H–deficient mice develop spontaneous hepatic tumors
Hepatocellular carcinoma (HCC) is difficult to detect, carries a poor prognosis, and is one of few cancers with an increasing yearly incidence. Molecular defects in complement factor H (CFH), a critical regulatory protein of the complement alternative pathway (AP), are typically associated with inflammatory diseases of the eye and kidney. Little is known regarding the role of CFH in controlling complement activation within the liver. While studying aging CFH-deficient (fH-/-) mice, we observed spontaneous hepatic tumor formation in more than 50% of aged fH-/- males. Examination of fH-/- livers (3-24 months) for evidence of complement-mediated inflammation revealed widespread deposition of complement-activation fragments throughout the sinusoids, elevated transaminase levels, increased hepatic CD8+ and F4/80+ cells, overexpression of hepatic mRNA associated with inflammatory signaling pathways, steatosis, and increased collagen deposition. Immunostaining of human HCC biopsies revealed extensive deposition of complement fragments within the tumors. Investigating the Cancer Genome Atlas also revealed that increased CFH mRNA expression is associated with improved survival in patients with HCC, whereas mutations are associated with worse survival. These results indicate that CFH is critical for controlling complement activation in the liver, and in its absence, AP activation leads to chronic inflammation and promotes hepatic carcinogenesis.
Zr-huJ591 immuno-PET imaging in patients with advanced metastatic prostate cancer
Given the bone tropism of prostate cancer, conventional imaging modalities poorly identify or quantify metastatic disease. (89)Zr-huJ591 positron emission tomography (PET) imaging was performed in patients with metastatic prostate cancer to analyze and validate this as an imaging biomarker for metastatic disease. The purpose of this initial study was to assess safety, biodistribution, normal organ dosimetry, and optimal imaging time post-injection for lesion detection. Ten patients with metastatic prostate cancer received 5 mCi of (89)Zr-huJ591. Four whole-body scans with multiple whole-body count rate measurements and serum activity concentration measurements were obtained in all patients. Biodistribution, clearance, and lesion uptake by (89)Zr-huJ591 immuno-PET imaging was analyzed and dosimetry was estimated using MIRD techniques. Initial assessment of lesion targeting of (89)Zr-huJ591 was done. Optimal time for imaging post-injection was determined. The dose was well tolerated with mild chills and rigors seen in two patients. The clearance of (89)Zr-huJ591 from serum was bi-exponential with biological half-lives of 7 ± 4.5 h (range 1.1-14 h) and 62 ± 13 h (range 51-89 h) for initial rapid and later slow phase. Whole-body biological clearance was 219 ± 48 h (range 153-317 h). The mean whole-body and liver residence time was 78.7 and 25.6 h, respectively. Dosimetric estimates to critical organs included liver 7.7 ± 1.5 cGy/mCi, renal cortex 3.5 ± 0.4 cGy/mCi, and bone marrow 1.2 ± 0.2 cGy/mCi. Optimal time for patient imaging after injection was 7 ± 1 days. Lesion targeting of bone or soft tissue was seen in all patients. Biopsies were performed in 8 patients for a total 12 lesions, all of which were histologically confirmed as metastatic prostate cancer. One biopsy-proven lesion was not positive on (89)Zr-huJ591, while the remaining 11 lesions were (89)Zr-huJ591 positive. Two biopsy-positive nodal lesions were noted only on (89)Zr-huJ591 study, while the conventional imaging modality was negative. (89)Zr-huJ591 PET imaging of prostate-specific membrane antigen expression is safe and shows good localization of disease in prostate cancer patients. Liver is the critical organ for dosimetry, and 7 ± 1 days is the optimal imaging time. A larger study is underway to determine lesion detection in an expanded cohort of patients with metastatic prostate cancer.
Imaging the pharmacodynamics of HER2 degradation in response to Hsp90 inhibitors
The development of therapeutic inhibitors of key signaling pathways has been hampered by the inability to assess the effect of a drug on its target in the patient. 17-allylaminogeldanamycin (17-AAG) is the first Hsp90 inhibitor to be tested in a clinical trial. It causes the degradation of HER2 and other Hsp90 targets, and has antitumor activity in preclinical models. We have developed a method for imaging the inhibition of Hsp90 by 17-AAG. We labeled an F(ab′) 2 fragment of the anti-HER2 antibody Herceptin with 68 Ga, a positron emitter, which allows the sequential positron-emission tomographic imaging of HER2 expression. We have used this method to quantify as a function of time the loss and recovery of HER2 induced by 17-AAG in animal tumors. This approach allows noninvasive imaging of the pharmacodynamics of a targeted drug and will facilitate the rational design of combination therapy based on target inhibition.
(124)I-huA33 antibody PET of colorectal cancer
Humanized A33 (huA33) is a promising monoclonal antibody that recognizes A33 antigen, which is present in more than 95% of colorectal cancers and in normal bowel. In this study, we took advantage of quantitative PET to evaluate (124)I huA33 targeting, biodistribution, and safety in patients with colorectal cancer. We also determined the biodistribution of (124)I-huA33 when a large dose of human intravenous IgG (IVIG) was administered to manipulate the Fc receptor or when (124)I-huA33 was given via hepatic arterial infusion (HAI). We studied 25 patients with primary or metastatic colorectal cancer; 19 patients had surgical exploration or resection. Patients received a median of 343 MBq (44.4-396 MBq) and 10 mg of (124)I-huA33. Nineteen patients received the antibody intravenously and 6 patients via HAI, and 5 patients also received IVIG. Ten of 12 primary tumors were visualized in 11 patients. The median concentration in primary colon tumors was 0.016% injected dose per gram, compared with 0.004% in normal colon. The PET-based median ratio of hepatic tumor uptake to normal-liver uptake was 3.9 (range, 1.8-22.2). Quantitation using PET, compared with well counting of serum and tissue, showed little difference. Prominent uptake in bowel hindered tumor identification in some patients. Pharmacokinetics showed that patients receiving IVIG had a significantly shorter serum half-time (41.6 ± 14.0 h) than those without (65.2 ± 9.8 h). There were no differences in clearance rates among the intravenous group, IVIG group, and HAI group, nor was there any difference in serum area under the curve, maximum serum concentration, or volume of distribution. Weak titers of human-antihuman antibodies were observed in 6 of 25 patients. No acute side effects or significant toxicities were associated with huA33. Good localization of (124)I-huA33 in colorectal cancer with no significant toxicity has been observed. PET-derived (124)I concentrations agreed well with those obtained by well counting of surgically resected tissue and blood, confirming the quantitative accuracy of (124)I-huA33 PET. The HAI route had no advantage over the intravenous route. No clinically significant changes in blood clearance were induced by IVIG.
124I-huA33 Antibody PET of Colorectal Cancer
Humanized A33 (huA33) is a promising monoclonal antibody that recognizes A33 antigen, which is present in more than 95% of colorectal cancers and in normal bowel. In this study, we took advantage of quantitative PET to evaluate 124I huA33 targeting, biodistribution, and safety in patients with colorectal cancer. We also determined the biodistribution of 124I-huA33 when a large dose of human intravenous IgG (IVIG) was administered to manipulate the Fc receptor or when 124I-huA33 was given via hepatic arterial infusion (HAI). METHODS: We studied 25 patients with primary or metastatic colorectal cancer; 19 patients had surgical exploration or resection. Patients received a median of 343 MBq (44.4-396 MBq) and 10 mg of 124I-huA33. Nineteen patients received the antibody intravenously and 6 patients via HAI, and 5 patients also received IVIG. RESULTS: Ten of 12 primary tumors were visualized in 11 patients. The median concentration in primary colon tumors was 0.016% injected dose per gram, compared with 0.004% in normal colon. The PET-based median ratio of hepatic tumor uptake to normal-liver uptake was 3.9 (range, 1.8-22.2). Quantitation using PET, compared with well counting of serum and tissue, showed little difference. Prominent uptake in bowel hindered tumor identification in some patients. Pharmacokinetics showed that patients receiving IVIG had a significantly shorter serum half-time (41.6 plus or minus 14.0 h) than those without (65.2 plus or minus 9.8 h). There were no differences in clearance rates among the intravenous group, IVIG group, and HAI group, nor was there any difference in serum area under the curve, maximum serum concentration, or volume of distribution. Weak titers of human-antihuman antibodies were observed in 6 of 25 patients. No acute side effects or significant toxicities were associated with huA33. CONCLUSION: Good localization of 124I-huA33 in colorectal cancer with no significant toxicity has been observed. PET-derived 124I concentrations agreed well with those obtained by well counting of surgically resected tissue and blood, confirming the quantitative accuracy of 124I-huA33 PET. The HAI route had no advantage over the intravenous route. No clinically significant changes in blood clearance were induced by IVIG.