Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
4
result(s) for
"Sobolevsky, Tim"
Sort by:
Detection of JWH-018 metabolites in smoking mixture post-administration urine
2010
Smoking mixtures containing the cannabimimetic indoles may still be available over-the-counter in several countries. Due to the high affinity of these compounds to the cannabinoid receptors, their effective dose is lower than that of the marijuana products resulting in a low concentration of the excreted metabolites accompanied by a higher psychoactive potency. Up to now the
in vivo metabolism of the cannabimimetic indoles seems to be insufficiently investigated and no data have been published on an assay of JWH-018 in urine.
In this publication the urinary metabolites of JWH-018 are reported. Using gas and liquid chromatography combined with tandem mass spectrometry two main monohydroxylated metabolites were identified in the forensic urine samples. Based on the differences in their electron ionization MS/MS spectra it is supposed that one is formed by hydroxylation of the indole ring whilst the other by hydroxylation of the
N-alkyl chain. The main metabolites are almost completely glucuroconjugated, whereas minor ones (
N-despentyl hydroxy-, carboxy-, dihydroxy-, and reduced di- and trihydroxy metabolites) were also present in the free fraction. The parent compound was not detected in urine.
Journal Article
Improving the accuracy of carbon-to-hydrogen ratio determination for P, N, S, O, Cl, and Br-containing organic compounds using atomic emission detection
2005
The objective of this work was to investigate the dependence of atomic emission detector C and H response on microwave-induced plasma conditions and to improve the accuracy of carbon-to-hydrogen ratio determination for trialkylphosphates, herbicides, chlorophenols, and sulfur-containing organic compounds. Compounds which differed structurally from the analytes were used as reference compounds. It was found that when the oxygen concentration in the helium was the maximum for the instrument (9%) relative errors in carbon-to-hydrogen ratio determination were 3-8%, irrespective of analyte and reference compound structure, whereas when working in the mode of operation recommended by the manufacturer of the instrument (1.5% oxygen in helium) the respective errors were 10-20% or higher. This improvement in the accuracy of carbon-to-hydrogen ratio determination was accompanied by a factor of ten decrease in sensitivity.
Journal Article