Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
9 result(s) for "Stavrakis, Adrian K."
Sort by:
Wearable humidity sensor embroidered on a commercial face mask and its electrical properties
Owing to the rapid development in the field of e-textile-based flexible and portable sensors, the present work demonstrates a fully textile-based stretchable face mask humidity sensor which was created using digital embroidery technique. The design of the sensor was comprised of interdigitated structured electrodes made up of polymer core-based conductive silver-coated threads and hygroscopic threads embedded between them. The fabricated sensor performed well towards moisture detection in accordance with the principle where resistance of the face mask sensor decreased with the increase in the relative humidity along with the changing operational frequency in the range from 1 Hz to 200 kHz. The electrical response (resistance, impedance, capacitance and phase angle) of the novel thread-based sensor towards change in relative humidity was recorded and showed in the present work. The embroidery of polymer-based threads onto the face mask towards humidity sensing offers a novel wearable platform for more extended biomedical applications for detection of various breath biomarkers and thus early diagnosis of diseases.
A novel method for in-situ extracting bio-impedance model parameters optimized for embedded hardware
A novel method for embedded hardware-based parameter estimation of the Cole model of bioimpedance is developed and presented. The model parameters R ∞ , R 1 and C are estimated using the derived set of equations based on measured values of real ( R ) and imaginary part ( X ) of bioimpedance, as well as the numerical approximation of the first derivative of quotient R / X with respect to angular frequency. The optimal value for parameter α is estimated using a brute force method. The estimation accuracy of the proposed method is very similar with the relevant work from the existing literature. Moreover, performance evaluation was performed using the MATLAB software installed on a laptop, as well as on the three embedded-hardware platforms (Arduino Mega2560, Raspberry Pi Pico and XIAO SAMD21). Obtained results showed that the used platforms can perform reliable bioimpedance processing with the same accuracy, while Raspberry Pi Pico is the fastest solution with the smallest energy consumption.
Portable Respiration Monitoring System with an Embroidered Capacitive Facemask Sensor
Respiration monitoring is a very important indicator of health status. It can be used as a marker in the recognition of a variety of diseases, such as sleep apnea, asthma or cardiac arrest. The purpose of the present study is to overcome limitations of the current state of the art in the field of respiration monitoring systems. Our goal was the development of a lightweight handheld device with portable operation and low power consumption. The proposed approach includes a textile capacitive sensor with interdigitated electrodes embroidered into the facemask, integrated with readout electronics. Readout electronics is based on the direct interface of the capacitive sensor and a microcontroller through just one analog and one digital pin. The microcontroller board and sensor are powered by a smartphone or PC through a USB cable. The developed mobile application for the Android™ operating system offers reliable data acquisition and acts as a bridge for data transfer to the remote server. The embroidered sensor was initially tested in a humidity-controlled chamber connected to a commercial impedance analyzer. Finally, in situ testing with 10 volunteering subjects confirmed stable operation with reliable respiration monitoring.
Gold Leaf-Based Microfluidic Platform for Detection of Essential Oils Using Impedance Spectroscopy
Drug delivery systems are engineered platforms for the controlled release of various therapeutic agents. This paper presents a conductive gold leaf-based microfluidic platform fabricated using xurography technique for its potential implication in controlled drug delivery operations. To demonstrate this, peppermint and eucalyptus essential oils (EOs) were selected as target fluids, which are best known for their medicinal properties in the field of dentistry. The work takes advantage of the high conductivity of the gold leaf, and thus, the response characteristics of the microfluidic chip are studied using electrochemical impedance spectroscopy (EIS) upon injecting EOs into its micro-channels. The effect of the exposure time of the chip to different concentrations (1% and 5%) of EOs was analyzed, and change in electrical resistance was measured at different time intervals of 0 h (the time of injection), 22 h, and 46 h. It was observed that our fabricated device demonstrated higher values of electrical resistance when exposed to EOs for longer times. Moreover, eucalyptus oil had stronger degradable effects on the chip, which resulted in higher electrical resistance than that of peppermint. 1% and 5% of Eucalyptus oil showed an electrical resistance of 1.79 kΩ and 1.45 kΩ at 10 kHz, while 1% and 5% of peppermint oil showed 1.26 kΩ and 1.07 kΩ of electrical resistance at 10 kHz respectively. The findings obtained in this paper are beneficial for designing suitable microfluidic devices to expand their applications for various biomedical purposes.
A Study of the Performance Degradation of Conductive Threads Based on the Effects of Tensile Forces and Repeated Washing
In recent years, after the ongoing success in the creation of portable electronic devices, an increasing effort has been put in creating wearable devices capable of sensing multiple parameters while being imperceptible to the user. A field that has recently gained attention due to this is that of textile electronics. For this purpose, one of the most commonly used materials is conductive threads, capable of sustaining an electrical connection, while at the same time being part of a garment. As research on the performance and stability of such threads is scarce, the aim of this work is to study the effects of tension on readily available conductive threads and to verify their suitability and reliability for e-textile applications. After testing seven commercially available threads, this study demonstrates that the nominal parameters provided by the manufacturers are not in line with experimentation, and that both embroidery and washing have an impact on their performance.
Performance Evaluation of Dental Flosses Pre- and Post-Utilization
Dental floss is an oral hygiene product used to remove food and plaque in places where toothbrushes cannot reach. Even though over the years since its introduction some research in suitable materials has been performed, thread cracking and wear can still compromise efficiency. The aim of this study was to examine the morphological properties of four different commercially available dental floss types before and after use. For that purpose, scanning electron microscopy and optical microscopy were used to assess the flosses before and after use, and tension testing was performed to determine any degradation in the floss performance after utilization. The analyzed floss samples verify the hypothesis that the properties of the floss need to be known in depth, before recommending a specific type to patients for daily use in all clinical indications.
Electrical Characterization of Conductive Threads for Textile Electronics
In recent years, advancements in technology are constantly driving the miniaturization of electronic devices, not only in the renowned domain of Internet-of-Things but also in other fields such as that of flexible and textile electronics. As the latter forms a great ecosystem for new devices, that could be functional such as heating garments or sensory, many suppliers have already started producing and bringing to market conductive threads that can be used by researchers and the mass public for their work. However, to date, no extensive characterization has been carried out with respect to the electrical performance of such threads and that is what this article is aiming to amend. Four commercially available threads by two different suppliers were put under test, to establish their limitations in terms of maximum power handling, both continuous and instantaneous. They were subsequently examined at a microscopic scale as well, to verify any potential caveats in their design, and any hidden limitations. A preliminary profile for each of the four threads was successfully established.
Association of QRS narrowing with response to cardiac resynchronization therapy—a systematic review and meta-analysis of observational studies
Prolonged QRS duration, which reflects a higher degree of mechanical dysynchrony, is a predictor of response to CRT. However, the association of QRS narrowing after biventricular pacing with CRT response rates is not clear. Our aim was to conduct a systematic review and meta-analysis on the association between QRS narrowing after cardiac resynchronization therapy (CRT) and clinical and echocardiographic response to CRT in patients with heart failure. Two independent investigators searched MedLine and EMBASE databases through July 2018 without any limitations. Studies providing estimates (continuous data) on the association of QRS shortening with either clinical (defined as New York Heart Association (NYHA) reduction ≥ 1) or echocardiographic (defined as left ventricular end-systolic volume (LVESV) reduction ≥ 15%) response to CRT were finally included in the quantitative synthesis. We included 32 studies (14 studies (1274 patients mean age 64 years old, males 79.3%) using clinical CRT response and 18 studies (1270 patients, mean age 64 years old, males 69.1%) using echocardiographic CRT response). A significant association between QRS narrowing and shorter attained QRS duration with clinical and echocardiographic CRT response was observed. The observed association was independent of the timing of QRS width measurement after CRT implantation. Acute and late improvement of electrical dysynchrony as depicted by QRS narrowing following biventricular pacing is associated with clinical and echocardiographic response to CRT. However, large prospective studies are needed to further examine our findings.
Impact of ranolazine on ventricular arrhythmias – A systematic review
Ranolazine is a new medication for the treatment of refractory angina. However, except its anti‐anginal properties, it has been found to act as an anti‐arrhythmic. The aim of our systematic review is to present the existing data about the impact of ranolazine in ventricular arrhythmias. We searched MEDLINE and Cochrane databases as well clinicaltrials.gov until September 1, 2017 to find all studies (clinical trials, observational studies, case reports/series) reported data about the impact of ranolazine in ventricular arrhythmias. Our search revealed 14 studies (3 clinical trials, 2 observational studies, 8 case reports, 1 case series). These data reported a beneficial impact of ranolazine in ventricular tachycardia/fibrillation, premature ventricular beats, and ICD interventions in different clinical settings. The existing data highlight the anti‐arrhythmic properties of ranolazine in ventricular arrhythmias.