Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
9 result(s) for "Steckiewicz, M."
Sort by:
Silver Nanoparticles as Chlorhexidine and Metronidazole Drug Delivery Platforms: Their Potential Use in Treating Periodontitis
Periodontal disease (PD), defined as oral inflammation caused by dental plaque, is an emerging problem. PD may lead to tooth loss, and treatment options are limited. In this study, we designed, synthesized, and characterized silver nanoparticles (AgNPs) conjugated with chlorhexidine (AgNPs-CHL) or metronidazole (AgNPs-PEG-MET) to determine whether they can be used to treat PDs. AgNPs were synthesized and characterized by transmission electron microscopy, UV-vis spectrometry, thermogravimetric analyses, and dynamic light scattering. We determined the safety and the antimicrobial and anti-inflammatory properties of synthesized AgNPs in an in vitro model of periodontitis. Antimicrobial properties were determined by measuring the minimum inhibitory concentration (MIC) and minimum biofilm eradication concentration (MBEC) on reference strains of bacteria and fungi. Human gingival fibroblast (HGF-1), murine macrophage (RAW264.7) and human foetal osteoblast (hFOB1.19) cells were used in the study. Lipopolysaccharide (LPS) was used to induce inflammation. Cytokine levels were measured using an enzyme-linked immunosorbent assay; metalloproteinase expression was measured using Western blotting. The synthesized AgNPs were spherical and narrow-dispersed with an average diameter of 13.4 nm ± 3.0 nm in the case of AgNPs-CHL and 3.72 nm ± 0.72 nm in the case of AgNPs-PEG-MET. Both types of AgNPs were active against bacteria and fungi. AgNPs-CHL proved to be a more potent antimicrobial agent, although they were more cytotoxic than AgNPs-PEG-MET; however, both demonstrated beneficial properties in nontoxic concentrations. AgNPs-CHL and AgNPs-PEG-MET decreased the production of proinflammatory cytokines IL-1β, IL-6, IL-8 and TNFα. Both agents also decreased the levels of metalloproteinases MMP3 and MMP8, which may indicate that they will inhibit tissue degradation. AgNPs-CHL and AgNPs-PEG-MET may be possible therapeutic options for PD, as they have antibacterial and anti-inflammatory properties. However, to fully understand the potential of AgNPs, our in vitro findings must be evaluated in an in vivo model.
Silver Nanoparticles as Chlorhexidine and Metronidazole Drug Delivery Platforms: Their Potential Use in Treating Periodontitis Corrigendum
Steckiewicz KP, Cieciórski P, Barcińska E, et al. Int J Nanomedicine. 2022;17:495-517. Our authors have advised that the funding source number listed in the Acknowledgment section on page 513 was incorrect. The sentence should read from \"This work was supported by PRELUDIUM grant 2017/27/N/NZ7/0267 from the Polish National Science Centre...\" to \"This work was supported by PRELUDIUM grant 2017/27/N/NZ7/02675 from the Polish National Science Centre...\" The authors apologize for this oversight.
Double superior vena cava and left brachiocephalic vein agenesis: a rare systemic vein anomaly and potential source of cardiac implantable electronic device and central venous catheter placement complications
Abnormal systemic vein development produces anomalous veins, which — in the case of persistent left superior vena cava and/or left brachiocephalic vein — exhibit considerable topographic and morphometric differences in comparison with their usual anatomy. The nature and extent of those developmental anomalies — detected during intravenous procedures, such as cardiac implantable electronic device (CIED) lead insertion or central venous catheter placement — may hinder the procedure itself and/or adversely affect its outcome, both at the stage of cardiac lead advancement through an abnormally shaped vessel and lead positioning within the heart. This may lead to problems in achieving optimal sensing and pacing parameters and in ensuring that the patient cannot feel the pacing impulses. These events accompanied a de novo CIED implantation procedure in the patient with a double superior vena cava and left brachiocephalic vein agenesis, who ultimately required reoperation.
Effect of Carbohydrate-Enriched Drink Compared to Fasting on Hemodynamics in Healthy Volunteers. A Randomized Trial
Fasting prior to surgery can cause dehydration and alter hemodynamics. This study aimed to determine the impact of a carbohydrate-enriched drink (NutriciaTM Pre-op®) on selected hemodynamical parameters, measured in a non-invasive manner. We enrolled 100 healthy volunteers and measured their weight, height, systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), thoracic fluid content (TFC), thoracic fluid index (TFCI), stroke volume (SV), stroke volume variation (SVV), stroke index (SI), cardiac output (CO), cardiac index (CI), heather index (HI), systolic time ration (STR), systemic time ratio index (STRI), systemic vascular resistance (SVR), and systemic vascular resistance index (SVRI) by a Niccomo™ device, implementing the impedance cardiography (ICG) method. Measurements were performed at the beginning of the study, and after 10 h and 12 h. We randomly allocated participants to the control group and the pre-op group. The pre-op group received 400 mL of Nutricia™ preOp®, as suggested in the ERAS guidelines, within 10 h of the study. Student’s t-test or the Mann–Whitney U test were used to compare the two groups, and p < 0.05 was considered significant. We did not observe any changes in hemodynamical parameters, blood pressure, and heart rate between the groups. We have proven that carbohydrate-enriched drink administration did not have a significant impact on the hemodynamical parameters of healthy volunteers.
Long-term Efficacy of Ibrutinib in Relapsed or Refractory Chronic Lymphocytic Leukemia: Results of the Polish Adult Leukemia Study Group Observational Study
To study the long-term clinical efficacy and tolerability of ibrutinib monotherapy in real-world relapsed and refractory chronic lymphocytic leukemia (RR-CLL) patients outside clinical trials. Clinical data of 171 RR-CLL patients treated with ibrutinib were collected within the observational study of the Polish Adult Leukemia Study Group. Median patient age was 64 years. Patients were pretreated with 3 (1-10) median lines of therapy, while 42 (24.6%) had 17p deletion. The median observation time was 40 months (range=1-59 months), while median ibrutinib monotherapy reached 37.5 months (range=0.4-59.2 months). Response was noted in 132 (77.2%) patients. The estimated 5-year progression-free survival (PFS) and overall survival (OS) rates were 61.1% (95%CI=49.3-70.9%) and 56.8% (95%CI=45.6-66.6%), respectively. At the time of analysis 97 (56.7%) remained under ibrutinib monotherapy. Ibrutinib is clinically effective and tolerable as a monotherapy in real-world RR-CLL patients.
Vasoconstrictive responses of the cephalic vein during first-time cardiac implantable electronic device placement
During cardiac implantable electronic device (CIED) implantation procedures cardiac leads have been mostly introduced transvenously. The associated injury to the selected vessel and adjacent tissues may induce reflex vasoconstriction. The aim of the study was to assess the incidence of cephalic vein (CV) vasoconstriction during first-time CIED implantation. Of the 146 evaluated first-time CIED implantation procedures conducted in our centre in 2016, we selected those during which CV vasoconstriction was recorded. We focused on the stage of the procedure involving CV cutdown and/or axillary vein (AV)/subclavian vein (SV) puncture for lead insertion. Only cases documented via venography were considered. Vasoconstriction was observed in 11 patients (5 females and 6 males, mean age 59.0 ± 21.2 years). The presence of this phenomenon affected the stage of CIED implantation involving cardiac lead insertion to the venous system, in severe cases, requiring a change of approach from CV cutdown to AV/SV puncture. The extent of vasoconstriction front propagation was limited to the nearest valves. Histological examinations of collected CV samples revealed an altered spatial arrangement of myocytes in the tunica media at the level of leaflet attachment. Cephalic vein vasoconstriction is a rare phenomenon associated with accessing the venous system during first-time CIED implantation. The propagation of CV constriction was limited by the location of the nearest valves.
Morphometric parameters of cardiac implantable electronic device (CIED) pocket walls observed on device replacement
Background: The final stage of a conventional de-novo cardiac implantable electronic device (CIED) implantation procedure with transvenous lead insertion involves the formation of a pocket by tissue separation superficial to the pectoralis major muscle in the right or left infraclavicular region, where the device is subsequently placed. Over time, a scar “capsule” is formed around the CIED as a result of normal biological remodelling. Materials and methods: The purpose of this study was to analyse the structure and present the variations of CIED capsules observed during device replacement. The nature and extent of this local tissue remodelling, which had occurred from the time of device implantation to its replacement in 2016 (10 ± 3.1 years), was analysed in 100 patients (mean age 77.1 ± 14.5 years), including 45 women and 55 men. Results: The most prevalent types of “capsules” (70% of cases) were those with similar thickness of both walls or a slightly thicker posterior (< 1.0 mm) than anterior wall (< 0.5 mm). The second most common capsule type (23% of cases) was characterised by a significantly thicker posterior wall of scar tissue (> 1.0 mm). The third group of capsules was characterised by various degrees of wall calcification (7% of cases). Conclusions: The extent and nature of scar tissue structure in the CIED pocket walls seem to correlate with the relative position of cardiac lead loops with respect to the device itself; where the more extensive scarring is likely to result from pocket wall irritation in the capsule formation phase due to lead movements underneath the device. The group of cases with calcified capsules was characterised by “old” device pockets (> 13 years) and the oldest population (patients in their 80s and 90s).
Selected clinical challenges of a supraclavicular cephalic vein in cardiac implantable electronic device implantation
Supraclavicular variations of the cephalic vein (CV) are detected sporadically. A somewhat more common finding is a CV variation with the typical course of the main vessel but with an additional supraclavicular branch, called the jugulocephalic vein (JCV). The aim of the study was to detect supraclavicular CVs or JCVs via intra-operative venography as well as assess their effects on primary and later revision cardiac implantable electronic device (CIED) procedures in our patients. We analysed venographic images obtained during CIED procedures at our centre between 2011 and 2015. Out of the 324 venographies conducted during first-time CIED implantation, we identified 14 showing either a supraclavicular course of the CV itself or a persistent JCV. Among revision procedure venographies, we identified 1 case of pertinent CV variations. These vessels had been morphometrically altered by previous medical interventions. Based on topography and morphometric parameters, we identified three anatomical variations of supraclavicular vessels: 2 cases of a supraclavicular CV and 12 cases of an infraclavicular CV accompanied by a persistent supraclavicular JCV (with the diameter larger than that of the main CV in 5 cases and smaller in 7 cases). In 2 cases the enlarged diameter of the JCV was probably due to increased collateral venous flow resulting from thrombotic lesions in the subclavian vein. Supraclavicular CV variations are rare. Nonetheless, they may significantly affect both first-time and later revision CIED procedures. The presence of a supraclavicular vein is an indication for diagnostic venography in the area of the clavipectoral triangle before the CIED procedure.
Clinical implications of cephalic vein morphometry in routine cardiac implantable electronic device insertion
Morphometric parameters of the venous vasculature constitute an important aspect in successful cardiac implantable electronic device (CIED) insertion. The purpose of this study was to present morpho-anatomical variations of the cephalic vein (CV) and their effect on the course of CIED implantation procedures, based on the patients from our centre. We analysed contrast venography results obtained during first-time lead placement. Venography was indicated in the cases of problematic lead introduction with either the CV cutdown or axillary/subclavian vein puncture techniques. The 214 cases of venography (15%) performed out of 1425 first-time lead placement in the period 2011-2013 were divided into 9 subgroups according to the most commonly observed CV variations of similar morpho-anatomical features that limited the use of the CV cutdown technique for lead insertion. The following CV morphometric parameters were found to be unfavo-urable in terms of lead placement: CV diameter of ≤ 1 mm (18%), sharp curva-ture of the terminal CV segment as it joined the axillary vein (14%), terminal CV bifurcation (9%), additional CV branches (7%) or tributaries (7%), stenoses (5%), sharply winding course (5%), single CV with a supraclavicular course (4%). The radiographic records obtained during the procedures allowed us to assess the prevalence of those atypical CV variations in our study group, with graphic presentation of characteristic types and sporadically reported CV variations.