Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
523 result(s) for "Stiller, M."
Sort by:
A Meta-Analysis of Intracortical Device Stiffness and Its Correlation with Histological Outcomes
Neural implants offer solutions for a variety of clinical issues. While commercially available devices can record neural signals for short time periods, they fail to do so chronically, partially due to the sustained tissue response around the device. Our objective was to assess the correlation between device stiffness, a function of both material modulus and cross-sectional area, and the severity of immune response. Meta-analysis data were derived from nine previously published studies which reported device material and geometric properties, as well as histological outcomes. Device bending stiffness was calculated by treating the device shank as a cantilevered beam. Immune response was quantified through analysis of immunohistological images from each study, specifically looking at fluorescent markers for neuronal nuclei and astrocytes, to assess neuronal dieback and gliosis. Results demonstrate that the severity of the immune response, within the first 50 µm of the device, is highly correlated with device stiffness, as opposed to device modulus or cross-sectional area independently. In general, commercially available devices are around two to three orders of magnitude higher in stiffness than devices which induced a minimal tissue response. These results have implications for future device designs aiming to decrease chronic tissue response and achieve increased long-term functionality.
Unconventional Magnetization below 25 K in Nitrogen-doped Diamond provides hints for the existence of Superconductivity and Superparamagnetism
The magnetization of nitrogen-doped single crystalline diamond bulk samples shows unconventional field and temperature hysteresis loops at T   ≲  25 K. The results suggest the existence of superparamagnetic and superconducting regions in samples with nitrogen concentration <200 ppm. Both phases vanish at temperatures above 25 K where the samples show diamagnetic behavior similar to undoped diamond. The observation of superparamagnetism and superconductivity is attributed to the nitrogen doping and to the existence of defective regions. From particle-induced X-ray emission with ppm resolution we rule out that the main observations below 25 K are due to magnetic impurities. We investigated also the magnetic properties of ferromagnetic/high-temperature superconducting oxide bilayers. The magnetization results obtained from those bilayers show remarkable similarities to the ones in nitrogen-doped diamond.
Combining Pultrusion with Carbonization: Process Analysis and Material Properties of CFRP and C/C
Composites made of carbon-fiber-reinforced carbon (C/C or CFC) are high-performance materials with a wide range of properties, making them especially suitable for the design of thermally and mechanically highly stressed components. As the production process of these high-performance materials is currently still very expensive, new concepts for an economical manufacturing process are required. This paper focusses on an innovative approach that uses the polymer-based pultrusion process for shaping with a subsequent carbonization step to C/C. In this process, carbon fibers (CF) and a phenolic resin were used to manufacture a semi-finished product made of unidirectional (UD) carbon-fiber-reinforced plastic (CFRP) with a fiber volume content of 66%. The C/C composite shows dimensional stability and has a flexural strength of approx. 240 MPa and a flexural modulus of approx. of 135 GPa with an elongation of 1.8%.
Chronic Intracortical Recording and Electrochemical Stability of Thiol-ene/Acrylate Shape Memory Polymer Electrode Arrays
Current intracortical probe technology is limited in clinical implementation due to the short functional lifetime of implanted devices. Devices often fail several months to years post-implantation, likely due to the chronic immune response characterized by glial scarring and neuronal dieback. It has been demonstrated that this neuroinflammatory response is influenced by the mechanical mismatch between stiff devices and the soft brain tissue, spurring interest in the use of softer polymer materials for probe encapsulation. Here, we demonstrate stable recordings and electrochemical properties obtained from fully encapsulated shape memory polymer (SMP) intracortical electrodes implanted in the rat motor cortex for 13 weeks. SMPs are a class of material that exhibit modulus changes when exposed to specific conditions. The formulation used in these devices softens by an order of magnitude after implantation compared to its dry, room-temperature modulus of ~2 GPa.
Mechanically Robust, Softening Shape Memory Polymer Probes for Intracortical Recording
While intracortical microelectrode arrays (MEAs) may be useful in a variety of basic and clinical scenarios, their implementation is hindered by a variety of factors, many of which are related to the stiff material composition of the device. MEAs are often fabricated from high modulus materials such as silicon, leaving devices vulnerable to brittle fracture and thus complicating device fabrication and handling. For this reason, polymer-based devices are being heavily investigated; however, their implementation is often difficult due to mechanical instability that requires insertion aids during implantation. In this study, we design and fabricate intracortical MEAs from a shape memory polymer (SMP) substrate that remains stiff at room temperature but softens to 20 MPa after implantation, therefore allowing the device to be implanted without aids. We demonstrate chronic recordings and electrochemical measurements for 16 weeks in rat cortex and show that the devices are robust to physical deformation, therefore making them advantageous for surgical implementation.
Inductive Heating of Ceramic Matrix Composites (CMC) for High-Temperature Applications
The inductive heating of a CMC susceptor for industrial applications can generate very high process temperatures. Thus, the behavior of a silicon carbide-based matrix with carbon-fiber-reinforced carbon (C/C-SiC) as a susceptor is investigated. Specifically, the influence of fiber length and the distribution of carbon fibers in the composite were investigated to find out the best parameters for the most efficient heating. For a multi-factorial set of requirements with a combination of filling levels and fiber lengths, a theoretical correlation of the material structure can be used as part of a digital model. Multi-physical simulation was performed to study the behavior of an alternating magnetic field generated by an inducing coil. The simulation results were verified by practical tests. It is shown that the inductive heating of a C/C-SiC susceptor can reach very high temperatures in a particularly fast and efficient way without oxidizing if it is ensured that a silicon carbide-based matrix completely encloses the fibers.
Patterns of Nucleotide Misincorporations during Enzymatic Amplification and Direct Large-scale Sequencing of Ancient DNA
Whereas evolutionary inferences derived from present-day DNA sequences are by necessity indirect, ancient DNA sequences provide a direct view of past genetic variants. However, base lesions that accumulate in DNA over time may cause nucleotide misincorporations when ancient DNA sequences are replicated. By repeated amplifications of mitochondrial DNA sequences from a large number of ancient wolf remains, we show that C/G-to-T/A transitions are the predominant type of such misincorporations. Using a massively parallel sequencing method that allows large numbers of single DNA strands to be sequenced, we show that modifications of C, as well as to a lesser extent of G, residues cause such misincorporations. Experiments where oligonucleotides containing modified bases are used as templates in amplification reactions suggest that both of these types of misincorporations can be caused by deamination of the template bases. New DNA sequencing methods in conjunction with knowledge of misincorporation processes have now, in principle, opened the way for the determination of complete genomes from organisms that became extinct during and after the last glaciation.
A Mosquito Inspired Strategy to Implant Microprobes into the Brain
Mosquitos are among the deadliest insects on the planet due to their ability to transmit diseases like malaria through their bite. In order to bite, a mosquito must insert a set of micro-sized needles through the skin to reach vascular structures. The mosquito uses a combination of mechanisms including an insertion guide to enable it to bite and feed off of larger animals. Here, we report on a biomimetic strategy inspired by the mosquito insertion guide to enable the implantation of intracortical microelectrodes into the brain. Next generation microelectrode designs leveraging ultra-small dimensions and/or flexible materials offer the promise of increased performance, but present difficulties in reliable implantation. With the biomimetic guide in place, the rate of successful microprobe insertion increased from 37.5% to 100% due to the rise in the critical buckling force of the microprobes by 3.8-fold. The prototype guides presented here provide a reproducible method to augment the insertion of small, flexible devices into the brain. In the future, similar approaches may be considered and applied to the insertion of other difficult to implant medical devices.
First experiences with a combined usage of veno-arterial and veno-venous ECMO in therapy-refractory cardiogenic shock patients with cerebral hypoxemia
The use of extracorporeal membrane oxygenation (ECMO) is becoming a popular tool in the treatment of cardiogenic shock. We present two case reports where classical veno-arterial peripherally cannulated ECMO therapy proved insufficient with profuse cerebral hypoxemia. After augmenting the setting into veno-veno-arterial ECMO, we achieved a remarkable improvement of all oxygenation parameters. The simultaneous use of veno-venous and veno-arterial ECMO might display as a novel strategy to counteract the coronary and cerebral hypoxemia in veno-arterial ECMO therapy in patients with therapy-refractory cardiogenic shock or in combined cardiopulmonary failure. In this manuscript, the veno-veno-arterial ECMO setup is described in full detail and different venous cannulas are discussed.
Inter-hospital transfer of ECMO-assisted patients with a portable miniaturized ECMO device: 4 years of experience
Objectives: Extracorporeal membrane oxygenation (ECMO) in patients with severe pulmonary failure is able to keep patients alive until organ regeneration, until shunting out for further diagnostic and therapeutic options or until transportation to specialized centers. Nonetheless, extracorporeal techniques require a high degree of expertise, so that a confinement to specialized centers is meaningful. Following from this requirement, the need for inter-hospital transfer of patients with severely compromised pulmonary function is rising. Methods: We report about our experience with a portable ECMO system during inter-hospital air or ground transfer of patients with cardiopulmonary failure. Results: The portable ECMO system was used for transportation to the center and in-hospital treatment in 36 patients with an average age of 53 years suffering from respiratory failure. Accordingly, the ECMO system was implanted as a veno-venous extracorporeal system. Pre-ECMO ventilation time was 5.2 (2-9) days. Twelve patients were transported to our institution by ground and 24 patients by air ambulance over a median distance of 46 km. With the assistance of the ECMO device, prompt stabilization of cardiopulmonary function could be achieved in all patients without any technical complications. Post-ECMO ventilation was 9.8 days. Weaning from the ECMO system was successful in 61% of all patients after a median device working period of 12.7 days; median ICU stay was 34 days and a survival rate of 64% of patients was achieved. Technical (8%) and device-associated bleeding (11%)/thromboembolic (8%) complication rates showed very acceptable levels. Conclusion: Our experience demonstrates that miniaturized, portable ECMO therapy allows location-independent, out-of-center stabilization of pulmonary compromised patients with consecutive inter-hospital transfer and further in-house treatment, so that sophisticated ECMO therapy can be offered to every patient, even in hospitals with primary healthcare.