Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
LanguageLanguage
-
SubjectSubject
-
Item TypeItem Type
-
DisciplineDiscipline
-
YearFrom:-To:
-
More FiltersMore FiltersIs Peer Reviewed
Done
Filters
Reset
87
result(s) for
"Strandhagen, C."
Sort by:
Results on light dark matter particles with a low-threshold CRESST-II detector
2016
The CRESST-II experiment uses cryogenic detectors to search for nuclear recoil events induced by the elastic scattering of dark matter particles in CaWO
4
crystals. Given the low energy threshold of our detectors in combination with light target nuclei, low mass dark matter particles can be probed with high sensitivity. In this letter we present the results from data of a single detector module corresponding to 52 kg live days. A blind analysis is carried out. With an energy threshold for nuclear recoils of 307 eV we substantially enhance the sensitivity for light dark matter. Thereby, we extend the reach of direct dark matter experiments to the sub- GeV/
c
2
region and demonstrate that the energy threshold is the key parameter in the search for low mass dark matter particles.
Journal Article
Results from 730 kg days of the CRESST-II Dark Matter search
by
Isaila, C.
,
Scholl, S.
,
Sivers, M. v.
in
Astronomy
,
Astrophysics and Cosmology
,
Calcium tungstates
2012
The CRESST-II cryogenic Dark Matter search, aiming at detection of WIMPs via elastic scattering off nuclei in CaWO
4
crystals, completed 730 kg days of data taking in 2011. We present the data collected with eight detector modules, each with a two-channel readout; one for a phonon signal and the other for coincidently produced scintillation light. The former provides a precise measure of the energy deposited by an interaction, and the ratio of scintillation light to deposited energy can be used to discriminate different types of interacting particles and thus to distinguish possible signal events from the dominant backgrounds.
Sixty-seven events are found in the acceptance region where a WIMP signal in the form of low energy nuclear recoils would be expected. We estimate background contributions to this observation from four sources: (1) “leakage” from the
e
/
γ
-band (2) “leakage” from the
α
-particle band (3) neutrons and (4)
206
Pb recoils from
210
Po decay. Using a maximum likelihood analysis, we find, at a statistical significance of more than 4
σ
, that these sources alone are not sufficient to explain the data. The addition of a signal due to scattering of relatively light WIMPs could account for this discrepancy, and we determine the associated WIMP parameters.
Journal Article
Low temperature light yield measurements in NaI and NaI(Tl)
2012
The scintillation light output of a pure and a Thallium doped Sodium Iodide (NaI) crystal under irradiation with 5.486 MeV
α
particles has been measured over a temperature range from 1.7 K to 300 K. Estimates of the decay time constant at three selected temperatures are given. For pure NaI an increase in light yield towards low temperatures could be confirmed and measured at higher precision. For NaI(Tl) below 60 K an increase in light output has been found.
Journal Article
Energy-dependent light quenching in CaWO4 crystals at mK temperatures
by
Gütlein, A.
,
Scholl, S.
,
Jochum, J.
in
Astronomy
,
Astrophysics and Cosmology
,
Calcium tungstates
2014
Scintillating CaWO
4
single crystals are a promising multi-element target for rare-event searches and are currently used in the direct dark matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers). The relative light output of different particle interactions in CaWO
4
is quantified by quenching factors (QFs). These are essential for an active background discrimination and the identification of a possible signal induced by weakly interacting massive particles (WIMPs). We present the first precise measurements of the QFs of O, Ca and W at mK temperatures by irradiating a cryogenic detector with a fast neutron beam. A clear energy dependence of the QF of O and, less pronounced, of Ca was observed for the first time. Furthermore, in CRESST neutron-calibration data a variation of the QFs among different CaWO
4
single crystals was found. For typical CRESST detectors the QFs in the region-of-interest (10–40 keV) are
QF
O
ROI
=
(
11.2
±
0.5
)
%,
QF
Ca
ROI
=
(
5.94
±
0.49
)
% and
QF
W
ROI
=
(
1.72
±
0.21
)
%. The latest CRESST data (run32) is reanalyzed using these fundamentally new results on light quenching in CaWO
4
having moderate influence on the WIMP analysis. Their relevance for future CRESST runs and for the clarification of previously published results of direct dark matter experiments is emphasised.
Journal Article
The CRESST-III low-mass WIMP detector
2016
The next generation direct dark matter experiment CRESST-III has a high potential to significantly increase the sensitivity to low-mass WIMPs (mx ≲10GeV/c2). We present the new CRESST detector module: it consists of a 24 g CaWO4 crystal operated as a phonon detector and a 20×20 mm2 silicon-on-sapphire light detector. The phonon energy threshold is lowered to ~100eV and a light detector resolution of typically 5eV is achieved. A fully-scintillating inner detector housing is realised which efficiently rejects events from surface-alpha decays. The CaWO4 sticks holding the target crystal are also operated as calorimeters to discriminate all possible artefacts related to the support structure. A projection for the sensitivity to spin-independent WIMP-nucleon scattering is given for the first phase of CRESST-III which will start beginning of 2016.
Journal Article
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter operated above ground
by
Gütlein, A.
,
Jochum, J.
,
Canonica, L.
in
Astronomy
,
Astrophysics and Cosmology
,
Elementary Particles
2017
Models for light dark matter particles with masses below 1 GeV/c
2
are a natural and well-motivated alternative to so-far unobserved weakly interacting massive particles. Gram-scale cryogenic calorimeters provide the required detector performance to detect these particles and extend the direct dark matter search program of CRESST. A prototype 0.5 g sapphire detector developed for the
ν
-cleus experiment has achieved an energy threshold of
E
t
h
=
(
19.7
±
0.9
)
eV. This is one order of magnitude lower than for previous devices and independent of the type of particle interaction. The result presented here is obtained in a setup above ground without significant shielding against ambient and cosmogenic radiation. Although operated in a high-background environment, the detector probes a new range of light-mass dark matter particles previously not accessible by direct searches. We report the first limit on the spin-independent dark matter particle-nucleon cross section for masses between 140 and 500 MeV/c
2
.
Journal Article
New results on low-mass dark matter from the CRESST-II experiment
2016
The CRESST-II experiment is searching for dark matter particles via their elastic scattering off nuclei in a target material. The CRESST target consists of scintillating CaW04 crystals which are operated as cryogenic calorimeters at millikelvin temperatures and read out by transition edge sensors. Each interaction in the CaW04 target crystal produces a phonon signal and also a light signal that is measured by a secondary cryogenic calorimeter. The low energy thresholds of these detectors, combined with the presence of light nuclei in the target material, allow to probe the low-mass region of the parameter space for spin-independent dark matter-nucleon scattering with high sensitivity. In this contribution results from a blind analysis of one detector module operated in the latest measurement campaign are presented. An unprecedented sensitivity for the light dark matter has been obtained with 52kg live days and a threshold of 307eV for nuclear recoils, extending the reach of direct dark matter searches to the sub-GeV/c2 region.
Journal Article
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter operated above ground
2017
Models for light dark matter particles with masses below 1 GeV/c [Formula omitted] are a natural and well-motivated alternative to so-far unobserved weakly interacting massive particles. Gram-scale cryogenic calorimeters provide the required detector performance to detect these particles and extend the direct dark matter search program of CRESST. A prototype 0.5 g sapphire detector developed for the [Formula omitted]-cleus experiment has achieved an energy threshold of [Formula omitted] eV. This is one order of magnitude lower than for previous devices and independent of the type of particle interaction. The result presented here is obtained in a setup above ground without significant shielding against ambient and cosmogenic radiation. Although operated in a high-background environment, the detector probes a new range of light-mass dark matter particles previously not accessible by direct searches. We report the first limit on the spin-independent dark matter particle-nucleon cross section for masses between 140 and 500 MeV/c [Formula omitted].
Journal Article
Results on low mass WIMPs using an upgraded CRESST-II detector
2014
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs via elastic scattering off nuclei in CaWO
4
crystals. We present results from a low-threshold analysis of a single upgraded detector module. This module efficiently vetoes low energy backgrounds induced by
α
-decays on inner surfaces of the detector. With an exposure of 29.35 kg live days collected in 2013 we set a limit on spin-independent WIMP-nucleon scattering which probes a new region of parameter space for WIMP masses below 3 GeV/c
2
, previously not covered in direct detection searches. A possible excess over background discussed for the previous CRESST-II phase 1 (from 2009 to 2011) is not confirmed.
Journal Article
DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes
by
Benato, G.
,
Bertolini, A.
,
Jochum, J.
in
Astronomy
,
Astrophysics and Cosmology
,
Collaboration
2024
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils induced by the scattering of dark matter particles in the detector. In CRESST, this low energy background manifests itself as a steeply rising population of events below 200 eV. A novel detector design named doubleTES using two identical TESs on the target crystal was studied to investigate the hypothesis that the events are sensor-related. We present the first results from two such modules, demonstrating their ability to differentiate between events originating from the crystal’s bulk and those occurring in the sensor or in its close proximity.
Journal Article