Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
20
result(s) for
"Strugnell, Wendy"
Sort by:
Cardiac MR: From Theory to Practice
by
Weingärtner, Sebastian
,
Ismail, Tevfik F.
,
Coletti, Chiara
in
Artificial intelligence
,
Cardiovascular Medicine
,
cardiovascular MR
2022
Cardiovascular disease (CVD) is the leading single cause of morbidity and mortality, causing over 17. 9 million deaths worldwide per year with associated costs of over $800 billion. Improving prevention, diagnosis, and treatment of CVD is therefore a global priority. Cardiovascular magnetic resonance (CMR) has emerged as a clinically important technique for the assessment of cardiovascular anatomy, function, perfusion, and viability. However, diversity and complexity of imaging, reconstruction and analysis methods pose some limitations to the widespread use of CMR. Especially in view of recent developments in the field of machine learning that provide novel solutions to address existing problems, it is necessary to bridge the gap between the clinical and scientific communities. This review covers five essential aspects of CMR to provide a comprehensive overview ranging from CVDs to CMR pulse sequence design, acquisition protocols, motion handling, image reconstruction and quantitative analysis of the obtained data. (1) The basic MR physics of CMR is introduced. Basic pulse sequence building blocks that are commonly used in CMR imaging are presented. Sequences containing these building blocks are formed for parametric mapping and functional imaging techniques. Commonly perceived artifacts and potential countermeasures are discussed for these methods. (2) CMR methods for identifying CVDs are illustrated. Basic anatomy and functional processes are described to understand the cardiac pathologies and how they can be captured by CMR imaging. (3) The planning and conduct of a complete CMR exam which is targeted for the respective pathology is shown. Building blocks are illustrated to create an efficient and patient-centered workflow. Further strategies to cope with challenging patients are discussed. (4) Imaging acceleration and reconstruction techniques are presented that enable acquisition of spatial, temporal, and parametric dynamics of the cardiac cycle. The handling of respiratory and cardiac motion strategies as well as their integration into the reconstruction processes is showcased. (5) Recent advances on deep learning-based reconstructions for this purpose are summarized. Furthermore, an overview of novel deep learning image segmentation and analysis methods is provided with a focus on automatic, fast and reliable extraction of biomarkers and parameters of clinical relevance.
Journal Article
An appraisal of lung computer tomography in very early anti-inflammatory treatment of two different ovine ARDS phenotypes
2024
Mortality and morbidity of Acute Respiratory Distress Syndrome (ARDS) are largely unaltered. A possible new approach to treatment of ARDS is offered by the discovery of inflammatory subphenotypes. In an ovine model of ARDS phenotypes, matching key features of the human subphenotypes, we provide an imaging characterization using computer tomography (CT). Nine animals were randomized into (a) OA (oleic acid, hypoinflammatory; n = 5) and (b) OA-LPS (oleic acid and lipopolysaccharides, hyperinflammatory; n = 4). 48 h after ARDS induction and anti-inflammatory treatment, CT scans were performed at high (H) and then low (L) airway pressure. After CT, the animals were euthanized and lung tissue was collected. OA-LPS showed a higher air fraction and OA a higher tissue fraction, resulting in more normally aerated lungs in OA-LPS in contrast to more non-aerated lung in OA. The change in lung and air volume between H and L was more accentuated in OA-LPS, indicating a higher recruitment potential. Strain was higher in OA, indicating a higher level of lung damage, while the amount of lung edema and histological lung injury were largely comparable. Anti-inflammatory treatment might be beneficial in terms of overall ventilated lung portion and recruitment potential, especially in the OA-LPS group.
Journal Article
T1 mapping performance and measurement repeatability: results from the multi-national T1 mapping standardization phantom program (T1MES)
2020
Background
The
T
1
Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored
T
1
mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report
T
1
measurement repeatability across centers describing sequence, magnet, and vendor performance.
Methods
Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging,
B
0
and
B
1
, and “reference” slow
T
1
testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific
T
1
mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple
T
1
mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial
T
1
was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of
T
1
variation.
Results
Over 2 years, phantom gel integrity remained intact (no rips/tears),
B
0
and
B
1
homogenous, and “reference”
T
1
stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T,
T
1
(MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated
T
1
times with “reference”
T
1
was similar across Siemens and Philips CMR systems at both field strengths (adjusted
R
2
ranges for both field strengths, 0.99–1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native
T
1
was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the
T
1
mapping sequence and scanner software version (both
P
< 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (
P
= 0.011, 1.5 T only), had the greatest influence on
T
1
across multiple centers.
Conclusion
The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting,
T
1
mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of
T
1
times for clinical use, although temperature correction is required for native
T
1
tubes at least.
Journal Article
Topographical distribution of perioperative cerebral infarction associated with transcatheter aortic valve implantation
by
Barnett, Adrian G.
,
Platts, David G.
,
Strugnell, Wendy E.
in
Anesthesia
,
Aortic valve
,
Blood clots
2018
Transcatheter aortic valve implantation (TAVI) is associated with a high incidence of cerebrovascular injury. As these injuries are thought to be primarily embolic, neuroprotection strategies have focused on embolic protection devices. However, the topographical distribution of cerebral emboli and how this impacts on the effectiveness of these devices have not been thoroughly assessed. Here, we evaluated the anatomical characteristics of magnetic resonance imaging (MRI)–defined cerebral ischemic lesions occurring secondary to TAVI to enhance our understanding of the distribution of cardioembolic phenomena.
Forty patients undergoing transfemoral TAVI with an Edwards SAPIEN-XT valve under general anesthesia were enrolled prospectively in this observational study. Participants underwent brain MRI preprocedure, and 3 ± 1 days and 6 ± 1 months postprocedure.
Mean ± SD participant age was 82 ± 7 years. Patients had an intermediate to high surgical risk, with a mean Society of Thoracic Surgeons score of 6.3 ± 3.5 and EuroSCORE of 18.1 ± 10.6. Post-TAVI, there were no clinically apparent cerebrovascular events, but MRI assessments identified 83 new lesions across 19 of 31 (61%) participants, with a median ± interquartile range number and volume of 1 ± 2.8 lesions and 20 ± 190 μL per patient. By volume, 80% of the infarcts were cortical, 90% in the posterior circulation and 81% in the right hemisphere.
The distribution of lesions that we detected suggests that cortical gray matter, the posterior circulation, and the right hemisphere are all particularly vulnerable to perioperative cerebrovascular injury. This finding has implications for the use of intraoperative cerebral embolic protection devices, particularly those that leave the left subclavian and, therefore, left vertebral artery unprotected.
[Display omitted]
Journal Article
Loss of connectivity in Alzheimer's disease: an evaluation of white matter tract integrity with colour coded MR diffusion tensor imaging
by
Rose, Stephen E
,
Zelaya, Fernando O
,
Semple, James
in
Aged
,
Aged, 80 and over
,
Alzheimer Disease - pathology
2000
A NOVEL MRI METHOD diffusion tensor imaging—was used to compare the integrity of several white matter fibre tracts in patients with probable Alzheimer's disease. Relative to normal controls, patients with probable Alzheimer's disease showed a highly significant reduction in the integrity of the association white matter fibre tracts, such as the splenium of the corpus callosum, superior longitudinal fasciculus, and cingulum. By contrast, pyramidal tract integrity seemed unchanged. This novel finding is consistent with the clinical presentation of probable Alzheimer's disease, in which global cognitive decline is a more prominent feature than motor disturbance.
Journal Article
T 1 mapping performance and measurement repeatability: results from the multi-national T 1 mapping standardization phantom program (T1MES)
by
Moon, James C
,
Steeds, Richard
,
Barison, Andrea
in
Calibration
,
Consensus
,
Extracellular volume
2020
The T
Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T
mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T
measurement repeatability across centers describing sequence, magnet, and vendor performance.
Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B
and B
, and \"reference\" slow T
testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T
mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T
mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T
was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T
variation.
Over 2 years, phantom gel integrity remained intact (no rips/tears), B
and B
homogenous, and \"reference\" T
stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T, T
(MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T
times with \"reference\" T
was similar across Siemens and Philips CMR systems at both field strengths (adjusted R
ranges for both field strengths, 0.99-1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T
was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T
mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (P = 0.011, 1.5 T only), had the greatest influence on T
across multiple centers.
The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T
mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T
times for clinical use, although temperature correction is required for native T
tubes at least.
Journal Article
Study protocol for a randomised controlled trial of exercise training in pulmonary hypertension (ExTra_(P)H)
by
Louis, Menaka
,
Harris, Julie
,
Lin, Aaron
in
Exercise cardiac magnetic resonance imaging
,
Exercise training
,
Pulmonary hypertension
2018
Abstract Background Exercise training is an integral component of evidence-based management programs for many chronic cardiac and respiratory conditions. Despite this, there are limited high-quality studies available on the significance of exercise training in pulmonary hypertension (PH). The aim of this study is to evaluate the short and long-term effectiveness of exercise training in PH patients in terms of exercise capacity, quality of life, cardiac function and disease progression. Methods This randomized control trial will aim to recruit 50 medically stable PH patients categorised as New York Heart Association functional classification II-III. Participants will be randomly allocated to either the supervised exercise training group or usual care group for the 8-week study period. Exercise training will be conducted in an outpatient setting. Measurements at baseline and following the 8-week study period include exercise capacity (6 min walk distance and cardiopulmonary exercise test), cardiac function (exercise cardiac magnetic resonance imaging [CMRI] and echocardiography), health-related quality of life (Cambridge Pulmonary Hypertension Outcome Review), adverse responses to exercise training and time to clinical worsening. In addition, participants will be followed up for a minimum of 2 year period from commencement of the study so as to monitor long-term clinical outcomes i.e. time to clinical worsening. Discussion This study will determine whether an 8-week outpatient based supervised exercise training program is safe and beneficial for medically stable PH patients in the short and long term. This will be the first study to examine the impact of exercise training on right heart function using exercise CMRI. Results from the study will contribute new knowledge in relation to the impact of exercise training on cardiac function, long-term prognosis and inform clinical practice guidelines for this patient population. Moreover, the study will add to our understanding regarding the efficacy of exercise training in individuals with PH in an outpatient setting. Trial registration Australia and New Zealand Clinical Trials Registry: ACTRN12616001467426. Registered 21st October, 2016.
Journal Article
CT angiography with cardiac MRI: non-invasive functional and anatomical assessment for the etiology in newly diagnosed heart failure
2012
Exclusion of ischemia is important in patients with newly diagnosed systolic heart failure (HF). We prospectively compared standard-of-care invasive catheter angiography (iCA) and echocardiography to a novel non-invasive strategy of both Coronary Computed Tomographic Angiography (CCTA) and Cardiovascular MRI (CMR) to determine the etiology of myocardial dysfunction Prospective data were collected from consecutive patients referred for iCA to investigate echocardiographically-confirmed new onset HF. CMR (1.5T GE) and dual source CCTA were performed within 2–7 days of iCA. Results were blinded and separately analyzed by expert readers. 426 coronary segments from 28 prospectively enrolled patients were analyzed by CCTA and quantitative iCA. The per-patient sensitivity and specificity of CCTA was 100% and 90%, respectively, negative predictive value (NPV) 100%, positive predictive value (PPV) 78%. Mean ejection fraction by CMR was 24%. Presence of ischemic-type LGE on CMR conferred a 67% sensitivity, 100% specificity, 90% NPV and 100% PPV. Combining CCTA with CMR conferred 100% specificity, 100% sensitivity, 100% PPV and 100% NPV for detection or exclusion of coronary disease. In patients with negative CCTA all invasive angiograms could have been avoided. In addition, two patients with no ischemic LGE by CMR had severe coronary disease on both CCTA and iCA, indicating global hibernation. This is a noteworthy finding in contrast to previous reports which suggested that absence of LGE rules out significant CAD. CCTA with CMR in newly-diagnosed HF enables non-invasive assessment of coronary artery disease, the severity and etiology of myocardial dysfunction and defines suitability for revascularization. Absence of ischemic-type LGE at CMR does not exclude CAD as a cause of LV dysfunction. A first-line strategy of functional and anatomic imaging with CMR and CCTA appears appropriate in newly diagnosed HF.
Journal Article