Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
4 result(s) for "Stucke-Straub, Kathrin"
Sort by:
Assessment of Photodynamic Therapy Penetration Depth in a Synthetic Pig Brain Model: A Novel Approach to Simulate the Reach of PDT-Mediated Effects In Vitro
Recurrence of glioblastoma (GBM) mostly occurs in close vicinity to the resection cavity. Therefore, our group has previously designed an implant to locally apply repetitive photodynamic therapy to mitigate tumor recurrence. The penetration depths of different wavelengths in brain tissue were exhaustively studied before. However, the PDT-induced biological effects of 5-ALA-based PDT against GBM cells at different depths have not been evaluated yet. Therefore, a synthetic brain substitute material of 1-10 mm thickness and with optical properties comparable to the white or gray matter of pig brain was developed. Tumor cell viability was assessed in spheroids from six GBM cell lines using disks of varying thickness prepared from pig brain substitute material to mimic in vivo radiation attenuation. Using an artificial brain tissue optical model based on material science, we have established a relationship between the PDT-induced effect of our PDT implant and the distance of migrating GBM cells from the resection cavity wall. This model may be helpful to aid optimization of the irradiation doses and fractionation required to attain the maximal therapeutic effect by long-term PDT applications.
GAITEX: Human motion dataset of impaired gait and rehabilitation exercises using inertial and optical sensors
Wearable inertial measurement units (IMUs) provide a cost-effective approach to assessing human movement in clinical and everyday environments. However, developing the associated classification models for robust assessment of physiotherapeutic exercise and gait analysis requires large, diverse datasets that are costly and time-consuming to collect. We present a multimodal dataset of physiotherapeutic and gait-related exercises, including correct and clinically relevant variants, recorded from 19 healthy subjects using synchronized IMUs and optical marker-based motion capture (MoCap). It contains data from nine IMUs and 68 markers tracking full-body kinematics. Four markers per IMU allow direct comparison between IMU- and MoCap-derived orientations. We additionally provide processed IMU orientations aligned to common segment coordinate systems, subject-specific OpenSim models, inverse kinematics outputs, and visualization tools for IMU-derived orientations. The dataset is fully annotated with movement quality ratings and timestamped segmentations. It supports various machine learning tasks such as exercise evaluation, gait classification, temporal segmentation, and biomechanical parameter estimation. Code for postprocessing, alignment, inverse kinematics, and technical validation is provided to promote reproducibility.
Disinfection of Human and Porcine Corneal Endothelial Cells by Far-UVC Irradiation
Background and Objectives: The cornea protects the eye from external influences and contributes to its refractive power. Corneas belong to the most frequently transplanted tissues, providing a last resort for preserving the patient’s vision. There is a high demand for donor corneas worldwide, but almost 4% of these transplants are not eligible due to microbial contamination. The objective of this study is to ascertain the suitability of 222 nm Far-UVC irradiation for the decontamination of corneas without damaging corneal endothelial cells. Materials and Methods: To assess the destructive effect of irradiation and, thus, identify the applicable dose needed to decontaminate the cornea without interfering with its integrity, 141 porcine corneas were irradiated with 0, 60 or 150 mJ/cm2 at 222 nm. In the second step, a series of 13 human corneas were subjected to half-sided irradiation using 15 or 60 mJ/cm2 at 222 nm. After five days of in vitro culturing, the endothelial cell density of the non-irradiated area of each human cornea was compared to the irradiated area. Results: Irradiation with up to 60 mJ/cm2 had no detectably significant effect on the cell integrity of human corneas (p = 0.764), with only a minimal reduction in cell density of 3.7% observed. These findings were partially corroborated by tests on porcine corneas, wherein the variability between test groups was consistent, even at increased irradiation doses of up to 150 mJ/cm2, and no notable effects on the irradiated porcine endothelium were monitored. The efficacy of the antimicrobial treatment was evident in the disinfection tests conducted on corneas. Conclusions: These initial irradiation experiments demonstrated that 222 nm Far-UVC radiation has the potential to decontaminate the cornea without compromising sensitive endothelial cell viability.
GAITEX: Human motion dataset of impaired gait and rehabilitation exercises using inertial and optical sensors
Wearable inertial measurement units (IMUs) provide a cost-effective approach to assessing human movement in clinical and everyday environments. However, developing the associated classification models for robust assessment of physiotherapeutic exercise and gait analysis requires large, diverse datasets that are costly and time-consuming to collect. We present a multimodal dataset of physiotherapeutic and gait-related exercises, including correct and clinically relevant variants, recorded from 19 healthy subjects using synchronized IMUs and optical marker-based motion capture (MoCap). It contains data from nine IMUs and 68 markers tracking full-body kinematics. Four markers per IMU allow direct comparison between IMU- and MoCap-derived orientations. We additionally provide processed IMU orientations aligned to common segment coordinate systems, subject-specific OpenSim models, inverse kinematics outputs, and visualization tools for IMU-derived orientations. The dataset is fully annotated with movement quality ratings and timestamped segmentations. It supports various machine learning tasks such as exercise evaluation, gait classification, temporal segmentation, and biomechanical parameter estimation. Code for postprocessing, alignment, inverse kinematics, and technical validation is provided to promote reproducibility.