Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
25 result(s) for "Suckau, Detlev"
Sort by:
A cross-platform toolkit for mass spectrometry and proteomics
Mass-spectrometry-based proteomics has become an important component of biological research. Numerous proteomics methods have been developed to identify and quantify the proteins in biological and clinical samples1, identify pathways affected by endogenous and exogenous perturbations2, and characterize protein complexes3. Despite successes, the interpretation of vast proteomics datasets remains a challenge. There have been several calls for improvements and standardization of proteomics data analysis frameworks, as well as for an application-programming interface for proteomics data access4,5. In response, we have developed the ProteoWizard Toolkit, a robust set of open-source, software libraries and applications designed to facilitate proteomics research. The libraries implement the first-ever, non-commercial, unified data access interface for proteomics, bridging field-standard open formats and all common vendor formats. In addition, diverse software classes enable rapid development of vendor-agnostic proteomics software. Additionally, ProteoWizard projects and applications, building upon the core libraries, are becoming standard tools for enabling significant proteomics inquiries.
direct and simple method of coupling matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) to thin-layer chromatography (TLC) for the analysis of phospholipids from egg yolk
Although the most important application of matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) is “proteomics,” there is growing evidence that this soft ionization method is also useful for phospholipid (PL) analysis. Although all PLs are detectable by MALDI-TOF MS, some lipid classes, particularly those with quaternary amines such as phosphatidylcholines (PCs), are more sensitively detected than others, and these suppress the signals of less sensitively detected PLs when complex mixtures are analyzed. Therefore, a separation of the total organic extract into individual lipid classes is necessary. As MALDI uses a solid sample, the direct evaluation of thin-layer chromatography (TLC) plates is possible. We report here on a method of directly coupling MALDI-TOF MS and TLC that can be easily implemented on commercially available MALDI-TOF devices. A total extract of hen egg yolk is used as a simple PL mixture to demonstrate the capabilities of this method. It will be shown that “clean” spectra without any major contributions from fragmentation products and matrix peaks can be obtained, and that this approach is even sensitive enough to detect the presence of PLs at levels of less than 1% of the total extract. [graphic removed]
Analysis of stem cell lipids by offline HPTLC-MALDI-TOF MS
MALDI-TOF MS is traditionally used for “proteomics”, but is also a useful tool for lipid analysis. Depending on the applied matrix, however, some lipid classes are more sensitively detected than other ones and this may even lead to suppression effects if complex mixtures are analyzed. Therefore, a previous separation into the individual lipid classes is necessary. Using artificial lipid mixtures or easily available tissue extracts, it has been already shown that HPTLC-(High Performance Thin-Layer Chromatography)-separated lipids can be conveniently analyzed by MALDI-TOF MS directly on the TLC plate. Here we present an initial TLC-MALDI study of the lipid composition of ovine mesenchymal stem cells. Due to the complex composition of these cells, data are also compared to lipids extracted from human erythrocytes. It will be shown that even very minor lipid classes can be easily detected and with much higher sensitivity than by common staining protocols. Additionally, MS images of the developed TLC plates will be shown and potential applications, new methods of data analysis as well as problems discussed. [graphic removed]
Toward Top-Down Determination of PEGylation Site Using MALDI In-Source Decay MS Analysis
A novel matrix assisted laser desorption/ionization (MALDI)-based mass spectrometric approach has been evaluated to rapidly analyze a custom designed PEGylated peptide that is 31 residues long and conjugated with 20 kDa linear polyethylene glycol (PEG) at the side chain of Lys. MALDI-TOF MS provided sufficiently high resolution to allow observation of each of the oligomers of the heterogeneous PEGylated peptide (m/Δm of ca. 500), while a typical ESI-MS spectrum of this molecule was extremely complex and unresolved. Reflector in-source decay (reISD) analysis using MALDI-TOF MS was attempted to identify the PEGylation site at intact molecular level without any sample treatment. An reISD spectrum of the free peptide was observed with abundant c-, y-, and [z + 2]-fragment ion series, whereas, in the fragmented PEGylated peptide, the fragment ion series were truncated at the residue where PEG was attached. Therefore, a direct comparison of these top-down reISD spectra suggested the location of the PEGylation site. Results from this study demonstrate a clear analytical utility of the ISD technique to characterize structural aspects of heterogeneous biomolecules. A MALDI-based in-source decay technique was utilized for rapid top-down MS analysis of a peptide conjugated with a 20 kDa polyethylene glycol.
MALDI tissue imaging: mass spectrometric localization of biomarkers in tissue slices
New mass-spectrometric proteomics technologies have been developed with the potential to transition from pure research applications into the diagnostic laboratory. Of these, one very promising technique has already gained much interest in the research community: matrix-assisted laser desorption/ionization (MALDI) molecular imaging. For easy and successful application of MALDI imaging in the laboratory, Bruker Daltonics offers an innovative product line: a stand-alone automated sample preparation device, ImagePrep™; mass spectrometers with vital smartbeam™ laser technology: namely, the autoflex III™ and ultraflex III™ MALDI–tandem time-of-flight (MALDI-TOF/TOF) instruments; and sophisticated software tools for fast data evaluation and biomarker visualization, flexImaging™.
Capabilities and Disadvantages of Combined Matrix-Assisted Laser-Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) and High-Performance Thin-Layer Chromatography (HPTLC): Analysis of Egg Yolk Lipids
Summary Lipids are important natural products and essential in nutrition, cosmetic formulations, pharmaceuticals, etc. Lipids and, particularly, phospholipids are of substantial medical interest (some are molecules with messenger function) and of diagnostic potential (for instance, the lipoproteins in human blood). Among the different soft-ionization mass spectrometric methods that enable detection of the intact lipid molecules, matrix-assisted laser-desorption/ioniza-tion time-of-flight mass spectrometry (MALDI-TOF MS) has several advantages, for instance, simple performance, high sensitivity, and robustness against contaminants. Additionally, MALDI-TOF MS analyzes a solid sample. This enables (in contrast with isotropic solutions) acquisition of spatially-resolved mass spectra (‘mass spec-trometric imaging’). However, separation of complex mixtures into the individual lipid classes is normally required to enable detection of all the components. It will be shown with the example of a lipid extract from hens’ egg yolk that MALDI-TOF MS can be easily combined with TLC, enabling detection of as little as picomole amounts of lipids directly on the HPTLC plate. This results in sensitivities higher than those from established staining procedures. Additionally, because of the substantial spatial resolution, lipids separated by normal-phase TLC may not only be differentiated according to differences of their headgroups but also according to differences of their fatty acyl composition. Finally, MS-MS experiments, providing further insights into the structures of the relevant lipids, can be also performed directly on the HPTLC plate. Although the HPTLC-MALDI coupling can be easily established, there are different points to which special attention should be paid. Aspects of matrix application, data acquisition (including the stability of lipids and reproducibility), and data evaluation will be emphasized in this paper.
Coexisting Stable Conformations of Gaseous Protein Ions
For further insight into the role of solvent in protein conformer stabilization, the structural and dynamic properties of protein ions in vacuo have been probed by hydrogen-deuterium exchange in a Fourier-transform mass spectrometer. Multiply charged ions generated by electrospray ionization of five proteins show exchange reactions with2H2O at 10-7 torr (1 torr = 133.3 Pa) exhibiting pseudo-first-order kinetics. Gas-phase compactness of the S-S cross-linked RNase A relative to denatured S-derivatized RNase A is indicated by exchange of 35 and 135 hydrogen atoms, respectively. For pure cytochrome c ions, the existence of at least three distinct gaseous conformers is indicated by the substantially different values-52, 113, and 74-of reactive H atoms; the observation of these same values for ions of a number-2, 7, and 5, respectively-of different charge states indicates conformational insensitivity to coulombic forces. For each of these conformers, the compactness in vacuo indicated by these values corresponds directly to that of a known conformer structure in the solution from which the conformer ions are produced by electrospray. S-derivatized RNase A ions also exist as at least two gaseous conformers exchanging 50-140 H atoms. Gaseous conformer ions are isomerically stable for hours; removal of solvent greatly increases conformational rigidity. More specific ion-molecule reactions could provide further details of conformer structures.
A novel MALDI LIFT-TOF/TOF mass spectrometer for proteomics
A new matrix-assisted laser-desorption/ionization time-of-flight/time-of-flight mass spectrometer with the novel \"LIFT\" technique (MALDI LIFT-TOF/TOF MS) is described. This instrument provides high sensitivity (attomole range) for peptide mass fingerprints (PMF). It is also possible to analyze fragment ions generated by any one of three different modes of dissociation: laser-induced dissociation (LID) and high-energy collision-induced dissociation (CID) as real MS/MS techniques and in-source decay in the reflector mode of the mass analyzer (relSD) as a pseudo-MS/MS technique. Fully automated operation including spot picking from 2D gels, in-gel digestion, sample preparation on MALDI plates with hydrophilic/hydrophobic spot profiles and spectrum acquisition/processing lead to an identification rate of 66% after the PMF was obtained. The workflow control software subsequently triggered automated acquisition of multiple MS/MS spectra. This information, combined with the PMF increased the identification rate to 77%, thus providing data that allowed protein modifications and sequence errors in the protein sequence database to be detected. The quality of the MS/MS data allowed for automated de novo sequencing and protein identification based on homology searching.
Cross Reactive Material 197 glycoconjugate vaccines contain privileged conjugation sites
Production of glycoconjugate vaccines involves the chemical conjugation of glycans to an immunogenic carrier protein such as Cross-Reactive-Material-197 (CRM 197 ). Instead of using glycans from natural sources recent vaccine development has been focusing on the use of synthetically defined minimal epitopes. While the glycan is structurally defined, the attachment sites on the protein are not. Fully characterized conjugates and batch-to-batch comparisons are the key to eventually create completely defined conjugates. A variety of glycoconjugates consisting of CRM 197 and synthetic oligosaccharide epitopes was characterised using mass spectrometry techniques. The primary structure was assessed by combining intact protein MALDI-TOF-MS, LC-MALDI-TOF-MS middle-down and LC-ESI-MS bottom-up approaches. The middle-down approach on CNBr cleaved glycopeptides provided almost complete sequence coverage, facilitating rapid batch-to-batch comparisons, resolving glycan loading and identification of side products. Regions close to the N- and C-termini were most efficiently conjugated.
Imaging mass spectrometry analysis of renal amyloidosis biopsies reveals protein co-localization with amyloid deposits
Amyloidosis is a heterogeneous group of protein misfolding diseases characterized by deposition of amyloid proteins. The kidney is frequently affected, especially by immunoglobulin light chain (AL) and serum amyloid A (SAA) amyloidosis as the most common subgroups. Current diagnosis relies on histopathological examination, Congo red staining, or electron microscopy. Subtyping is done by immunohistochemistry; however, commercially available antibodies lack specificity. The purpose of this study was to identify and map amyloid proteins in formalin-fixed paraffin-embedded tissue sections using matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis in an integrated workflow. Renal amyloidosis and non-amyloidosis biopsies were processed for histological and MS analysis. Mass spectra corresponding to the congophilic areas were directly linked to the histological and MS images for correlation studies. Peptides for SAA and AL were detected by MALDI IMS associated to Congo red-positive areas. Sequence determination of amyloid peptides by LC-MS/MS analysis provided protein distribution and identification. Serum amyloid P component, apolipoprotein E, and vitronectin proteins were identified in both AA and AL amyloidosis, showing a strong correlation with Congo red-positive regions. Our findings highlight the utility of MALDI IMS as a new method to type amyloidosis in histopathological routine material and characterize amyloid-associated proteins that may provide insights into the pathogenetic process of amyloid formation. Graphical abstract Image correlation between hematoxylin and eosin, histochemistry (Congo red), and MALDI IMS of tissue sections from a patient affected with AA-amyloidosis. Hematoxylin and eosin staining ( HE ) shows glomerular structures ( black arrows ). Amyloid deposits appear in red in the Congo red-stained section in bright light ( CR ), and show an apple-green birefringence under polarized light ( GB , yellow arrows ). MALDI images for m/z = 1456.72, m/z = 1811.89 and m/z = 1156.6 correlate with Congo-red positive areas