Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
131 result(s) for "Tarassenko, Lionel"
Sort by:
Pulse arrival time as a surrogate of blood pressure
Various models have been proposed for the estimation of blood pressure (BP) from pulse transit time (PTT). PTT is defined as the time delay of the pressure wave, produced by left ventricular contraction, measured between a proximal and a distal site along the arterial tree. Most researchers, when they measure the time difference between the peak of the R-wave in the electrocardiogram signal (corresponding to left ventricular depolarisation) and a fiducial point in the photoplethysmogram waveform (as measured by a pulse oximeter attached to the fingertip), describe this erroneously as the PTT. In fact, this is the pulse arrival time (PAT), which includes not only PTT, but also the time delay between the electrical depolarisation of the heart’s left ventricle and the opening of the aortic valve, known as pre-ejection period (PEP). PEP has been suggested to present a significant limitation to BP estimation using PAT. This work investigates the impact of PEP on PAT, leading to a discussion on the best models for BP estimation using PAT or PTT. We conducted a clinical study involving 30 healthy volunteers (53.3% female, 30.9 ± 9.35 years old, with a body mass index of 22.7 ± 3.2 kg/m 2 ). Each session lasted on average 27.9 ± 0.6 min and BP was varied by an infusion of phenylephrine (a medication that causes venous and arterial vasoconstriction). We introduced new processing steps for the analysis of PAT and PEP signals. Various population-based models (Poon, Gesche and Fung) and a posteriori models (inverse linear, inverse squared and logarithm) for estimation of BP from PTT or PAT were evaluated. Across the cohort, PEP was found to increase by 5.5 ms ± 4.5 ms from its baseline value. Variations in PTT were significantly larger in amplitude, − 16.8 ms ± 7.5 ms. We suggest, therefore, that for infusions of phenylephrine, the contribution of PEP on PAT can be neglected. All population-based models produced large BP estimation errors, suggesting that they are insufficient for modelling the complex pathways relating changes in PTT or PAT to changes in BP. Although PAT is inversely correlated with systolic blood pressure (SBP), the gradient of this relationship varies significantly from individual to individual, from − 2946 to − 470.64 mmHg/s in our dataset. For the a posteriori inverse squared model, the root mean squared errors (RMSE) for systolic and diastolic blood pressure (DBP) estimation from PAT were 5.49 mmHg and 3.82 mmHg, respectively. The RMSEs for SBP and DBP estimation by PTT were 4.51 mmHg and 3.53 mmHg, respectively. These models take into account individual calibration curves required for accurate blood pressure estimation. The best performing population-based model (Poon) reported error values around double that of the a posteriori inverse squared model, and so the use of population-based models is not justified.
Features from the photoplethysmogram and the electrocardiogram for estimating changes in blood pressure
There is a growing emphasis being placed on the potential for cuffless blood pressure (BP) estimation through modelling of morphological features from the photoplethysmogram (PPG) and electrocardiogram (ECG). However, the appropriate features and models to use remain unclear. We investigated the best features available from the PPG and ECG for BP estimation using both linear and non-linear machine learning models. We conducted a clinical study in which changes in BP ( Δ BP) were induced by an infusion of phenylephrine in 30 healthy volunteers (53.8% female, 28.0 (9.0) years old). We extracted a large and diverse set of features from both the PPG and the ECG and assessed their individual importance for estimating Δ BP through Shapley additive explanation values and a ranking coefficient. We trained, tuned, and evaluated linear (ordinary least squares, OLS) and non-linear (random forest, RF) machine learning models to estimate Δ BP in a nested leave-one-subject-out cross-validation framework. We reported the results as correlation coefficient ( ρ p ), root mean squared error (RMSE), and mean absolute error (MAE). The non-linear RF model significantly ( p < 0.05 ) outperformed the linear OLS model using both the PPG and the ECG signals across all performance metrics. Estimating Δ SBP using the PPG alone ( ρ p = 0.86 (0.23), RMSE = 5.66 (4.76) mmHg, MAE = 4.86 (4.29) mmHg) performed significantly better than using the ECG alone ( ρ p = 0.69 (0.45), RMSE = 6.79 (4.76) mmHg, MAE = 5.28 (4.57) mmHg), all p < 0.001 . The highest ranking features from the PPG largely modelled increasing reflected wave interference driven by changes in arterial stiffness. This finding was supported by changes observed in the PPG waveform in response to the phenylephrine infusion. However, a large number of features were required for accurate BP estimation, highlighting the high complexity of the problem. We conclude that the PPG alone may be further explored as a potential single source, cuffless, blood pressure estimator. The use of the ECG alone is not justified. Non-linear models may perform better as they are able to incorporate interactions between feature values and demographics. However, demographics may not adequately account for the unique and individualised relationship between the extracted features and BP.
Exacerbations in Chronic Obstructive Pulmonary Disease: Identification and Prediction Using a Digital Health System
Chronic obstructive pulmonary disease (COPD) is a progressive, chronic respiratory disease with a significant socioeconomic burden. Exacerbations, the sudden and sustained worsening of symptoms, can lead to hospitalization and reduce quality of life. Major limitations of previous telemonitoring interventions for COPD include low compliance, lack of consensus on what constitutes an exacerbation, limited numbers of patients, and short monitoring periods. We developed a telemonitoring system based on a digital health platform that was used to collect data from the 1-year EDGE (Self Management and Support Programme) COPD clinical trial aiming at daily monitoring in a heterogeneous group of patients with moderate to severe COPD. The objectives of the study were as follows: first, to develop a systematic and reproducible approach to exacerbation identification and to track the progression of patient condition during remote monitoring; and second, to develop a robust algorithm able to predict COPD exacerbation, based on vital signs acquired from a pulse oximeter. We used data from 110 patients, with a combined monitoring period of more than 35,000 days. We propose a finite-state machine-based approach for modeling COPD exacerbation to gain a deeper insight into COPD patient condition during home monitoring to take account of the time course of symptoms. A robust algorithm based on short-period trend analysis and logistic regression using vital signs derived from a pulse oximeter is also developed to predict exacerbations. On the basis of 27,260 sessions recorded during the clinical trial (average usage of 5.3 times per week for 12 months), there were 361 exacerbation events. There was considerable variation in the length of exacerbation events, with a mean length of 8.8 days. The mean value of oxygen saturation was lower, and both the pulse rate and respiratory rate were higher before an impending exacerbation episode, compared with stable periods. On the basis of the classifier developed in this work, prediction of COPD exacerbation episodes with 60%-80% sensitivity will result in 68%-36% specificity. All 3 vital signs acquired from a pulse oximeter (pulse rate, oxygen saturation, and respiratory rate) are predictive of COPD exacerbation events, with oxygen saturation being the most predictive, followed by respiratory rate and pulse rate. Combination of these vital signs with a robust algorithm based on machine learning leads to further improvement in positive predictive accuracy. International Standard Randomized Controlled Trial Number (ISRCTN): 40367841; http://www.isrctn.com/ISRCTN40367841 (Archived by WebCite at http://www.webcitation.org/6olpMWNpc).
Early risk assessment for COVID-19 patients from emergency department data using machine learning
Since its emergence in late 2019, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a pandemic with more than 55 million reported cases and 1.3 million estimated deaths worldwide. While epidemiological and clinical characteristics of COVID-19 have been reported, risk factors underlying the transition from mild to severe disease among patients remain poorly understood. In this retrospective study, we analysed data of 879 confirmed SARS-CoV-2 positive patients admitted to a two-site NHS Trust hospital in London, England, between January 1st and May 26th, 2020, with a majority of cases occurring in March and April. We extracted anonymised demographic data, physiological clinical variables and laboratory results from electronic healthcare records (EHR) and applied multivariate logistic regression, random forest and extreme gradient boosted trees. To evaluate the potential for early risk assessment, we used data available during patients’ initial presentation at the emergency department (ED) to predict deterioration to one of three clinical endpoints in the remainder of the hospital stay: admission to intensive care, need for invasive mechanical ventilation and in-hospital mortality. Based on the trained models, we extracted the most informative clinical features in determining these patient trajectories. Considering our inclusion criteria, we have identified 129 of 879 (15%) patients that required intensive care, 62 of 878 (7%) patients needing mechanical ventilation, and 193 of 619 (31%) cases of in-hospital mortality. Our models learned successfully from early clinical data and predicted clinical endpoints with high accuracy, the best model achieving area under the receiver operating characteristic (AUC-ROC) scores of 0.76 to 0.87 (F1 scores of 0.42–0.60). Younger patient age was associated with an increased risk of receiving intensive care and ventilation, but lower risk of mortality. Clinical indicators of a patient’s oxygen supply and selected laboratory results, such as blood lactate and creatinine levels, were most predictive of COVID-19 patient trajectories. Among COVID-19 patients machine learning can aid in the early identification of those with a poor prognosis, using EHR data collected during a patient’s first presentation at ED. Patient age and measures of oxygenation status during ED stay are primary indicators of poor patient outcomes.
The impact of wearable continuous vital sign monitoring on deterioration detection and clinical outcomes in hospitalised patients: a systematic review and meta-analysis
Background Timely recognition of the deteriorating inpatient remains challenging. Wearable monitoring systems (WMS) may augment current monitoring practices. However, there are many barriers to implementation in the hospital environment, and evidence describing the clinical impact of WMS on deterioration detection and patient outcome remains unclear. Objective To assess the impact of vital-sign monitoring on detection of deterioration and related clinical outcomes in hospitalised patients using WMS, in comparison with standard care. Methods A systematic search was conducted in August 2020 using MEDLINE, Embase, CINAHL, Cochrane Database of Systematic Reviews, CENTRAL, Health Technology Assessment databases and grey literature. Studies comparing the use of WMS against standard care for deterioration detection and related clinical outcomes in hospitalised patients were included. Deterioration related outcomes (primary) included unplanned intensive care admissions, rapid response team or cardiac arrest activation, total and major complications rate. Other clinical outcomes (secondary) included in-hospital mortality and hospital length of stay. Exploratory outcomes included alerting system parameters and clinical trial registry information. Results Of 8706 citations, 10 studies with different designs met the inclusion criteria, of which 7 were included in the meta-analyses. Overall study quality was moderate. The meta-analysis indicated that the WMS, when compared with standard care, was not associated with significant reductions in intensive care transfers (risk ratio, RR 0.87; 95% confidence interval, CI 0.66–1.15), rapid response or cardiac arrest team activation (RR 0.84; 95% CI 0.69–1.01), total (RR 0.77; 95% CI 0.44–1.32) and major (RR 0.55; 95% CI 0.24–1.30) complications prevalence. There was also no statistically significant association with reduced mortality (RR 0.48; 95% CI 0.18–1.29) and hospital length of stay (mean difference, MD − 0.09; 95% CI − 0.43 to 0.44). Conclusion This systematic review indicates that there is no current evidence that implementation of WMS impacts early deterioration detection and associated clinical outcomes, as differing design/quality of available studies and diversity of outcome measures make it difficult to reach a definite conclusion. Our narrative findings suggested that alarms should be adjusted to minimise false alarms and promote rapid clinical action in response to deterioration. PROSPERO Registration number : CRD42020188633 .
Non-contact vital-sign monitoring of patients undergoing haemodialysis treatment
A clinical study was designed to record a wide range of physiological values from patients undergoing haemodialysis treatment in the Renal Unit of the Churchill Hospital in Oxford. Video was recorded for a total of 84 dialysis sessions from 40 patients during the course of 1 year, comprising an overall video recording time of approximately 304.1 h. Reference values were provided by two devices in regular clinical use. The mean absolute error between the heart rate estimates from the camera and the average from two reference pulse oximeters (positioned at the finger and earlobe) was 2.8 beats/min for over 65% of the time the patient was stable. The mean absolute error between the respiratory rate estimates from the camera and the reference values (computed from the Electrocardiogram and a thoracic expansion sensor—chest belt) was 2.1 breaths/min for over 69% of the time for which the reference signals were valid. To increase the robustness of the algorithms, novel methods were devised for cancelling out aliased frequency components caused by the artificial light sources in the hospital, using auto-regressive modelling and pole cancellation. Maps of the spatial distribution of heart rate and respiratory rate information were developed from the coefficients of the auto-regressive models. Most of the periods for which the camera could not produce a reliable heart rate estimate lasted under 3 min, thus opening the possibility to monitor heart rate continuously in a clinical environment.
Non-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit
The implementation of video-based non-contact technologies to monitor the vital signs of preterm infants in the hospital presents several challenges, such as the detection of the presence or the absence of a patient in the video frame, robustness to changes in lighting conditions, automated identification of suitable time periods and regions of interest from which vital signs can be estimated. We carried out a clinical study to evaluate the accuracy and the proportion of time that heart rate and respiratory rate can be estimated from preterm infants using only a video camera in a clinical environment, without interfering with regular patient care. A total of 426.6 h of video and reference vital signs were recorded for 90 sessions from 30 preterm infants in the Neonatal Intensive Care Unit (NICU) of the John Radcliffe Hospital in Oxford. Each preterm infant was recorded under regular ambient light during daytime for up to four consecutive days. We developed multi-task deep learning algorithms to automatically segment skin areas and to estimate vital signs only when the infant was present in the field of view of the video camera and no clinical interventions were undertaken. We propose signal quality assessment algorithms for both heart rate and respiratory rate to discriminate between clinically acceptable and noisy signals. The mean absolute error between the reference and camera-derived heart rates was 2.3 beats/min for over 76% of the time for which the reference and camera data were valid. The mean absolute error between the reference and camera-derived respiratory rate was 3.5 breaths/min for over 82% of the time. Accurate estimates of heart rate and respiratory rate could be derived for at least 90% of the time, if gaps of up to 30 seconds with no estimates were allowed.
SMARThealth India: A stepped-wedge, cluster randomised controlled trial of a community health worker managed mobile health intervention for people assessed at high cardiovascular disease risk in rural India
Cardiovascular diseases (CVD) are rising in India resulting in major health system challenges. Eighteen primary health centre (PHC) clusters in rural Andhra Pradesh were randomised over three, 6-month steps to an intervention comprising: (1) household CVD risk assessments by village-based community health workers (CHWs) using a mobile tablet device; (2) electronic referral and clinical decision support for PHC doctors; and (3) a tracking system for follow-up care. Independent data collectors screened people aged ≥ 40 years in 54 villages serviced by the PHCs to create a high CVD risk cohort (based on WHO risk charts and blood pressure thresholds). Randomly selected, independent samples, comprising 15% of this cohort, were reviewed at each 6-month step. The primary outcome was the proportion meeting systolic blood pressure (SBP) targets (<140mmHg). Eight-four percent of the eligible population (n = 62,254) were assessed at baseline (18.4% at high CVD risk). Of those at high risk, 75.3% were followed up over two years. CHWs screened 85.9% of the baseline cohort and doctors followed up 70.0% of all high risk referrals. There was no difference in the proportion of people achieving SBP targets (41.2% vs 39.2%; adjusted odds ratio (OR) 1.01 95% CI 0.76-1.35) or receiving BP-lowering medications in the intervention vs control periods respectively. There was a high discordance in risk scores generated by independent data collectors and CHWs, resulting in only 37.2% of the evaluation cohort exposed to the intervention. This discordance was mainly driven by fluctuating BP values (both normal variability and marked seasonal variations). In the pre-specified high risk concordant subgroup, there was greater use of BP-lowering medications in the intervention period (54.3% vs 47.9%, OR 1.22, 95% CI 1.03-1.44) but no impact on BP control. The strategy was well implemented with increased treatment rates among high risk individuals assessed by CHWs, however effects on BP were not demonstrated. Use of guideline-recommended BP thresholds for identifying high risk individuals substantially affected the reproducibility of risk assessment, and thus the ability to reliably evaluate the effectiveness of the intervention. In addition, unanticipated seasonal variation in BP in the context of a stepped-wedge trial highlights the inherent risks of this study design. Clinical Trials Registry of India CTRI/2013/06/ 003753.
Identification of motor progression in Parkinson’s disease using wearable sensors and machine learning
Wearable devices offer the potential to track motor symptoms in neurological disorders. Kinematic data used together with machine learning algorithms can accurately identify people living with movement disorders and the severity of their motor symptoms. In this study we aimed to establish whether a combination of wearable sensor data and machine learning algorithms with automatic feature selection can estimate the clinical rating scale and whether it is possible to monitor the motor symptom progression longitudinally, for people with Parkinson’s Disease. Seventy-four patients visited the lab seven times at 3-month intervals. Their walking (2-minutes) and postural sway (30-seconds,eyes-closed) were recorded using six Inertial Measurement Unit sensors. Simple linear regression and Random Forest algorithms were utilised together with different routines of automatic feature selection or factorisation, resulting in seven different machine learning algorithms to estimate the clinical rating scale (Movement Disorder Society- Unified Parkinson’s Disease Rating Scale part III; MDS-UPDRS-III). Twenty-nine features were found to significantly progress with time at group level. The Random Forest model revealed the most accurate estimation of the MDS-UPDRS-III among the seven models. The model estimations detected a statistically significant progression of the motor symptoms within 15 months when compared to the first visit, whereas the MDS-UPDRS-III did not capture any change. Wearable sensors and machine learning can track the motor symptom progression in people with PD better than the conventionally used clinical rating scales. The methods described in this study can be utilised complimentary to the clinical rating scales to improve the diagnostic and prognostic accuracy.