Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
14
result(s) for
"Terazawa, Sachie"
Sort by:
Administration of an antibody against apoptosis inhibitor of macrophage prevents aortic aneurysm progression in mice
by
Fujii, Taro
,
Narita, Yuji
,
Yamawaki-Ogata, Aika
in
692/308/1426
,
692/4019/592/75/593/1301
,
Angiotensin
2024
Apoptosis inhibitor of macrophage (AIM) is known to induce apoptosis resistance in macrophages and to exacerbate chronic inflammation, leading to arteriosclerosis. The role of AIM in aortic aneurysm (AA) remains unknown. This study examined the effects of an anti-AIM antibody in preventing AA formation and progression. In apolipoprotein E-deficient mice, AA was induced by subcutaneous angiotensin II infusion. Mice were randomly divided into two groups: (i) AIM group; weekly anti-murine AIM monoclonal antibody injection (n = 10), and (ii) IgG group; anti-murine IgG antibody injection as control (n = 14). The AIM group, compared with the IgG group, exhibited reduced AA enlargement (aortic diameter at 4 weeks: 2.1 vs. 2.7 mm, respectively, p = 0.012); decreased loss of elastic lamellae construction; reduced expression levels of IL-6, TNF-α, and MCP-1; decreased numbers of AIM-positive cells and inflammatory M1 macrophages (AIM: 1.4 vs. 8.0%, respectively, p = 0.004; M1 macrophages: 24.5 vs. 55.7%, respectively, p = 0.017); and higher expression of caspase-3 in the aortic wall (22.8 vs. 10.5%, respectively, p = 0.019). Our results suggest that administration of an anti-AIM antibody mitigated AA progression by alleviating inflammation and promoting M1 macrophage apoptosis.
Journal Article
HeartMate 3 driveline damage by gradual corrosion due to liquid infiltration: a case report
by
Ito, Hideki
,
Narita, Yuji
,
Sakurai, Hajime
in
Adult
,
Biomedical Engineering and Bioengineering
,
Cables
2025
A 31-year-old man with a HeartMate 3 was admitted with a “Driveline Communication Fault” alarm due to liquid infiltration. Eleven months earlier, the connector between the modular and pump cables had gotten wet when he was taking a shower. The cable connector was dried immediately, and no alarm had been observed during follow-up. Subsequently, the modular cable and system controller were replaced, with corrosion found on the modular cable connector. The “Communication Fault” alarm recurred, and complete damage to the communication cables was discovered. The pump was replaced, and the removed pump cable connector showed corrosion as well. If the driveline connector gets wet, the multidisciplinary team should discuss if it should be immediately disconnected and dried, averting the need for future pump replacements due to corrosion.
Journal Article
Sudden circulatory collapse caused by mechanical obstruction of the left main coronary trunk with infective endocarditis vegetation: a case report
by
Ito, Hideki
,
Narita, Yuji
,
Tokuda, Yoshiyuki
in
Acute coronary syndrome
,
Acute coronary syndromes
,
Aneurysms
2021
Background
Acute coronary syndrome (ACS) caused by mechanical obstruction of the coronary artery with a vegetation is extremely rare but associated with high mortality. The optimal management strategy of this condition remains controversial because of its scarcity. We experienced a case of sudden circulatory collapse due to mechanical occlusion of the left main coronary trunk with a vegetation.
Case presentation
A 68-year-old woman with aortic and mitral valve infective endocarditis suffered sudden dyspnea followed by heart arrest while awaiting surgery. Despite treatment with adequate antibiotic therapy, she had had multiple embolic infarctions and ruptured infectious cerebral aneurysms. We conducted transcatheter arterial embolization of the aneurysm and postponed the cardiac surgery due to residual aneurysmal blood flow. She suffered sudden cardiac arrest, and extracorporeal membrane oxygenation was applied after cardiopulmonary resuscitation. An echocardiogram revealed diffuse severe hypokinesis, and emergency coronary angiography was performed under suspicion of ACS. It revealed obstruction of the left main coronary trunk by a vegetation. Emergent cardiac surgery was performed. A vegetation had occluded the left coronary orifice. Aortic and mitral valve replacement with coronary artery bypass to the left antero-descending branch was performed. Regarding her cardiac function, she still required extracorporeal membrane oxygenation after surgery. She passed away 19 days after surgery due to multiple organ failure.
Conclusions
ACS caused by mechanical obstruction of the coronary artery with a vegetation is rare but associated with high mortality. When circulatory collapse acutely occurs in patients with aortic valve infective endocarditis, we should suspect acute coronary artery obstruction. Urgent coronary angiography is mandatory to rescue the patient while preparing for emergency surgery.
Journal Article
The incidence and risk factors of hypofibrinogenemia in cardiovascular surgery
by
Toshiaki Akita
,
Yoshiyuki Tokuda
,
Kazuro Fujimoto
in
Afibrinogenemia
,
Aged
,
Aged, 80 and over
2020
Objective
Cardiovascular surgery often causes massive bleeding due to coagulopathy, with hypofibrinogenemia being a major causative factor. We assessed the intraoperative incidence of hypofibrinogenemia and explored predictors of hypofibrinogenemia.
Methods
The intraoperative serum fibrinogen level (SFL) was routinely measured in 872 consecutive patients [mean age: 66.9 ± 13.3 years; 598 men (68.6%)] undergoing cardiovascular surgery from July 2013 to November 2016 at Nagoya University Hospital. There were 275 aortic surgeries, 200 cases of coronary artery bypass grafting (CABG), 334 valvular surgeries and 63 other surgeries. We estimated hypofibrinogenemia incidence (intraoperative lowest SFL ≤ 150 mg/dL) and identified its predictors by a logistic regression analysis.
Results
The average intraoperative lowest SFL of all cases, aortic surgery, CABG and valvular surgery was 185 ± 71, 156 ± 65, 198 ± 69 and 198 ± 68 mg/dL, respectively. Aortic surgery had a significantly lower intraoperative lowest SFL than CABG (
p
< 0.001) and valvular surgery (
p
< 0.001). The incidence of hypofibrinogenemia was 32.8%, 50.2%, 26.5% and 22.8% in all cases, aortic surgery, CABG and valvular surgery, respectively. The predictors of hypofibrinogenemia were the preoperative SFL, re-do surgery and perfusion time. A receiver operating characteristics curve analysis showed that the best preoperative SFL cutoff value for predicting hypofibrinogenemia was 308.5 mg/dL. Assuming preoperative SFL 300 mg/dL as the cutoff, the odds ratio for hypofibrinogenemia was 7.22 (95% confidence interval 5.26–9.92,
p
< 0.001).
Conclusions
The incidence of hypofibrinogenemia in aortic surgery was high. The preoperative SFL, re-do surgery and perfusion time were identified as predictors for hypofibrinogenemia. Intraoperative measurement of SFL is important for detecting hypofibrinogenemia and applying appropriate and prompt transfusion treatment.
Journal Article
Spinal cord injury following aortic arch replacement
by
Matsumura, Yasumoto
,
Ito, Hideki
,
Ishida, Shinichi
in
Aneurysms
,
Atherosclerosis
,
Coronary vessels
2020
PurposePostoperative spinal cord injury is a devastating complication after aortic arch replacement. The purpose of this study was to determine the predictors of this complication.MethodsA group of 254 consecutive patients undergoing aortic arch replacement via median sternotomy, with (n = 78) or without (n = 176) extended replacement of the upper descending aorta, were included in a risk analysis. The frozen elephant trunk technique was used in 46 patients. The patients’ atherothrombotic lesions (extensive intimal thickening of > 4 mm) were identified from computed tomography images.ResultsComplete paraplegia (n = 7) and incomplete paraparesis (n = 4) occurred immediately after the operation (permanent spinal cord injury rate, 1.97%; transient spinal cord injury rate, 2.36%). A multivariable logistic regression analysis identified the use of the frozen elephant trunk technique (odds ratio 36.3), previous repair of thoracoabdominal aorta or descending aorta (odds ratio 29.4), proximal atherothrombotic aorta (odds ratio 9.6), chronic obstructive lung disease (odds ratio 7.1) and old age (odds ratio 1.1) as predictors of spinal cord injury (p < 0.0001, area under curve 0.93).ConclusionsSpinal cord injury occurs with a non-negligible incidence following aortic arch replacement. The full objective assessment of the morphology of the whole aorta and the recognition of the risk factors are mandatory.
Journal Article
Higher F-wave frequency associates with poor procedural success rate after Maze procedure
2022
Objectives
Persistent atrial fibrillation (AF) causes atrial remodeling, which causes myocardial fibrosis and micro-reentry. Fibrosis may reduce wave voltage and micro-reentry may enhance the dominant frequency (DF) of the F-wave. We investigated whether the DF predicts procedural success by the Maze procedure.
Methods
In 138 consecutive patients who underwent mitral valve surgery and a modified Cox-Maze III procedure for persistent AF in Nagoya University in 2002–2018, 96 (70%) were successfully cardioverted (group S); 42 had persistent or relapsed AF after surgery (group F). Patient data were compared between the groups. Cut-off values were determined by an ROC analysis and predictors of procedural success were evaluated. The DF was obtained from the F-wave of V1 by a high-speed Fourier analysis using the CEPAS software program.
Results
Group F showed a significantly larger LA diameter, better LVEF, lower F-wave voltage, higher DF, and longer duration of AF. The cut-off values were as follows: LA diameter, 56 mm; EF, 64.5%; F-wave voltage, 0.13 mV; DF, 7.3 Hz; and duration of AF, 44 months. Each factor showed statistical significance in a univariate analysis; DF lost significance in the multivariate analysis. The higher (DF ≥ 7.3 Hz) and lower voltage group (≤ 0.13 mV) showed the worst procedural success rate (36%), while the lower DF (< 7.3 Hz) and higher voltage group (> 0.13 mV) showed a good rate (86%).
Conclusions
The DF of the F-wave is a useful predictor of procedural success after the Maze procedure in addition to the voltage of F-wave.
Journal Article
Multiple giant coronary artery aneurysms with extended coronary ectasia emerging 12 years after previous coronary artery bypass grafting
2022
A 73-year-old man presented with multiple giant coronary artery aneurysms. Twelve years prior to the presentation, he had undergone coronary artery bypass grafting. At that time, he exhibited small aneurysms (16 mm diameter) in the right coronary artery and a single aneurysm (10 mm diameter) in the left circumflex artery. During follow-up, the aneurysms gradually increased in size (to 45 and 30 mm, respectively, at 12 years after surgery). We resected all of the aneurysms and performed coronary artery bypass grafting of the left circumflex artery through re-sternotomy.
Journal Article
Influence of the characteristics of Japanese patients on the long-term outcomes after aortic valve replacement: results of a microsimulation
by
Narita, Yuji
,
Araki, Yoshimori
,
Fujimoto, Kazuro
in
Aged
,
Aged, 80 and over
,
Aortic Valve - surgery
2015
Objectives
The aim of this study was to explore the influence of the characteristics of Japanese patients on the long-term outcomes after aortic valve replacement with either mechanical or biological prostheses by means of a microsimulation.
Methods
A microsimulation model was used to simulate the lives of patients living in Japan and in the United States after aortic valve replacement. The background mortality data taken from the 21st complete life table of Japan and the bleeding hazard determined from a meta-analysis of long-term results in Japanese institutions were used to simulate Japanese patients. The life expectancy, event-free life expectancy, and lifetime risk of structural valve degeneration were calculated. A sensitivity analysis for various bleeding hazards was performed.
Results
Regarding the event-free life expectancy, the age crossover points between the two valve types were 64–65 and 57–58 years for Japanese and American patients, respectively. Regarding the life expectancy, the age crossover points were 88–89 and 64–65 years, respectively, for Japanese and American patients. The lifetime risk of structural valve degeneration was higher in Japanese patients than in American patients. The sensitivity analysis showed that the age crossover points were sensitive to the hazard of bleeding complications.
Conclusions
The long-term clinical outcomes after aortic valve replacement were simulated with a microsimulation model. The results indicated that the age crossover points in the advantages and disadvantages between mechanical valves and bioprostheses may be higher in Japanese patients than in American subjects.
Journal Article