Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
36
result(s) for
"Thulasidas, Mithun"
Sort by:
Retropupillary Iris-Claw Intraocular Lenses: A Literature Review
2021
Retropupillary iris-claw intraocular lenses (ICIOLs) have been increasingly chosen by surgeons nowadays as a primary or secondary procedure of IOL implantation in eyes with insufficient capsular or zonular support. They have gained popularity due to their simple fast technique, favourable functional outcomes, and safety. The transition in the ICIOL fixation from prepupillary to a more biologically appropriate retropupillary position and change in the optic design from biconvex to convex-concave have provided better visual outcomes and improved safety. A peer-reviewed literature search was conducted in Medline (PubMed), Embase, and Cochrane Library using the keywords \"retropupillary iris claw\" and \"iris claw\". The search yielded 310 articles that were screened. Forty-three articles on retropupillary ICIOLs were finally found to be relevant and reviewed in full-text versions. The functional outcomes following retropupillary implantation of ICIOLs have been acceptable in eyes with no ocular co-morbidities otherwise. However, the indications for surgery may affect the outcomes. The major postoperative complications directly associated with ICIOLs include pupil ovalization and redislocation. Nevertheless, the rate of disenclavation depends on the experience and skill of the surgeon. This review is based on a literature review, and it focuses on the preoperative evaluation, surgical technique, postoperative outcomes, and associated complications. Prospective randomized trials with a larger sample size and longer follow-up are needed for comparison with other techniques of IOL fixation and confirmation of long-term safety profile. Keywords: iris-claw, retropupillary iris-claw, posterior iris-claw, IOL dislocation
Journal Article
Flow capsulorhexis: A novel technique in white and hypermature cataracts
2024
We described a novel \"flow capsulorhexis\" technique in white and hypermature cataracts and compared it with the standard \"needle decompression capsulorhexis\" technique. Six hundred and eight eyes of 420 patients with intumescent or non-intumescent mature white cataracts who had undergone phacoemulsification or manual small incision cataract surgery with \"flow capsulorhexis\" (Group 1) or \"needle decompression capsulorhexis\" (Group 2) were assessed. The mean continuous curvilinear capsulorhexis (CCC) completion time was 6.6 ± 3.4 seconds in Group 1 and 10.4 ± 4.2 seconds in Group 2 (P < 0.001). The mean number of times for an ophthalmic viscosurgical device (OVD) supplement was 0.4 ± 0.2 and 1.8 ± 0.8 in Group 1 and Group 2, respectively (P < 0.001). CCC success rate was 95.8% in Group 1 and 87.2% in Group 2 (P = 0.001). The new technique was observed to have better outcomes in terms of surgical time, OVD supplement times, and success rate than the standard needle decompression technique.
Journal Article
Evaluation of corneal topography and tomography in fellow eyes of unilateral keratoconus patients for early detection of subclinical keratoconus
by
Thulasidas, Mithun
,
Teotia, Prateek
in
belin/ambrosio enhanced ectasia display
,
Care and treatment
,
Cornea
2020
Purpose: To analyse topographic and tomographic changes in fellow eyes of unilateral keratoconus patients by comparing them with normal eyes. Methods: This five-year retrospective observational comparative case study included 15 advanced keratoconus eyes of unilateral keratoconus (KCN group), 15 normal fellow eyes of unilateral keratoconus (Fellow eye group) and 34 eyes of normal refractive surgery candidates (Normal group). Topographic and tomographic data, data from enhanced elevation maps, and keratoconus indices were measured in all study eyes using Pentacam. Receiver operating characteristic (ROC) curves were used to evaluate the area under the curve (AUC), sensitivity and specificity of each parameter and identify cut-off points in discriminating between the fellow and normal eyes. Results: Corneal thickness at the apex (CTA, P = 0.001) and at the thinnest point (CTT, P < 0.001), corneal volume (CV, P = 0.007), Belin/Ambrosio Enhanced Ectasia Display (BAD) - thinnest point (Dt, P = 0.002) and thinnest point displacement (Da, P = 0.002) were significantly lower in the fellow group compared to eyes of normal subjects. On ROC curve analysis, the most efficient distinguishing indices between the fellow group and normal controls were BAD - overall D value (AUC = 0.859), Dt (AUC =0.827), Da (AUC = 0.789) followed by pachymetric progression index maximum (AUC = 0.741). Conclusion: BAD-D value and pachymetric progression index could be useful in detecting the earliest form of subclinical keratoconus. However, every single parameter alone is not enough to detect early changes; a combination of different data is required to distinguish subclinical keratoconus.
Journal Article
Comparison of Perimetric Outcomes from Melbourne Rapid Fields Tablet Perimeter Software and Humphrey Field Analyzer in Glaucoma Patients
2020
Purpose. To compare visual field results obtained using Melbourne Rapid Fields (MRF) iPad-based perimeter software and Humphrey Field Analyzer (HFA) 24-2 Swedish Interactive Threshold Algorithm (SITA) standard program in glaucoma patients. Design. A cross-sectional observational study. Methods. In this single-centre study involving patients diagnosed with glaucoma, the perimetric outcomes of MRF were compared against those returned from the HFA 24-2 SITA standard. Outcomes included mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI)/visual capacity (VC), foveal threshold, test time, number of points depressed at P<5% on PSD probability plot, and glaucoma hemifield test/color coded indicator. Results. The study included 28 eyes of 28 glaucoma patients. Mean (standard deviation) test times were 342.07 (56.70) seconds for MRF and 375.11 (88.95) for HFA 24-2 SITA standard P=0.046. Mean MD was significantly lower for MRF (Δ = 3.09, P<0.001), and mean PSD was significantly higher for MRF (Δ = 1.40, P=0.005) compared with HFA. The mean foveal threshold for the MRF was significantly lower than the mean HFA foveal threshold ((Δ = 9.25, P<0.001). The number of points depressed at P<5% on the PSD probability plot was significantly less for MRF P<0.001. Other perimetric outcomes showed no significant differences between both. Bland–Altman plots showed that considerable variability existed between the programs. Conclusion. MRF is a good cost-effective, time-saving, user-friendly tool for monitoring visual fields in settings where access to traditional perimetry is limited. The lack of Internet strength in rural areas and questionable detection of early cases may be two points in MRF fields requiring an upgrade.
Journal Article
Comparison of the clinical outcomes of Eyecryl™ and Tecnis® toric intraocular lenses: A real-world study
by
Thulasidas, Mithun
,
Pradeep, Balam
,
Sasidharan, Ajita
in
Acuity
,
Astigmatism
,
Astigmatism - complications
2022
Purpose:
To compare the postoperative uncorrected distance visual acuity (UDVA) and refractive outcomes of cataract patients with astigmatism following implantation of Eyecryl™ and Tecnis® toric intraocular lenses (IOLs).
Methods:
We conducted a single-center, retrospective study including patients who had undergone phacoemulsification and implantation with either Eyecryl™ toric (Group 1) or Tecnis® toric (Group 2) IOL. The primary outcome measures included postoperative UDVA and residual astigmatism at 3 months. The secondary outcome measure was IOL misalignment >10° throughout the follow-up period.
Results:
One hundred and eight eyes of 76 patients (44 males and 32 females) were analyzed. Twenty-nine patients (38 eyes) received Eyecryl™ toric IOL (Group 1), and 47 patients (70 eyes) received Tecnis® toric IOL (Group 2). Groups 1 and 2 showed a mean postoperative logMAR UDVA of 0.09 ± 0.11 and 0.06 ± 0.09, respectively, at 3 months (P = 0.114). In both groups, all the eyes achieved a postoperative UDVA of ≤0.3 logMAR. The postoperative residual astigmatism of group 1 and group 2 was -0.29 ± 0.34 D and -0.16 ± 0.27 D, respectively (P = 0.038). Postoperative astigmatism was within ± 1.00 D in all the eyes. No eyes had an IOL misalignment >10° throughout the follow-up period.
Conclusion:
Both Eyecryl™ and Tecnis® toric IOLs provided significant improvement in uncorrected visual acuity and astigmatism correction postoperatively. The Tecnis® toric IOL provided statistically significant lower residual astigmatism than Eyecryl™toric IOL. However, the difference in postoperative astigmatism between the two IOLs was clinically insignificant.
Journal Article
Comparison of peripapillary capillary plexus using optical coherence tomography angiography and retinal nerve fibre layer analysis using spectral domain optical coherence tomography in glaucoma patients, glaucoma suspects, and healthy subjects
by
Dutta, Ananya
,
Sasidharan, Ajita
,
Thulasidas, Mithun
in
Angiography
,
Care and treatment
,
Comparative analysis
2022
Purpose:
To assess the association between radial peripapillary capillary (RPC) plexus using optical coherence tomography angiography (OCTA) and retinal nerve fibre layer (RNFL) thickness using spectral domain OCT (SD-OCT) in primary open-angle glaucoma (POAG) patients, glaucoma suspects, and healthy subjects.
Methods:
In this single-centre cross-sectional observational study, POAG, glaucoma suspects, and healthy patients underwent OCT-RNFL and optic nerve head angiography scans. The RNFL thickness and the vascular parameters obtained from RPC plexus, including perfusion density (PD), flux index (FI), and vessel density (VD), were analysed.
Results:
In all, 120 eyes of 120 patients, including 40 POAG patients, 40 glaucoma suspects, and 40 healthy subjects, were included. The pairwise comparison of mean RNFL thickness, FI, and VD showed significant difference (P < 0.001) in all sectors between POAG, glaucoma suspects, and healthy eyes. However, PD showed no significant difference between glaucoma suspects and healthy eyes. The average RNFL thickness was found to have a better diagnostic ability than VD to distinguish POAG eyes from healthy eyes and glaucoma suspects based on receiver operating characteristics curve and area under the curve. VD had better diagnostic accuracy than RNFL when glaucoma suspects and healthy were compared.
Conclusion:
OCT-RNFL has better diagnostic capability in differentiating glaucoma from healthy eyes compared to OCTA. However, OCTA was found to be better in screening out glaucoma suspects from healthy eyes. The VD is a better OCTA parameter than FI and PD to differentiate POAG and glaucoma suspects from healthy eyes.
Journal Article