Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
14 result(s) for "Tomoki Ohori"
Sort by:
Different effects of the lateral meniscus complete radial tear on the load distribution and transmission functions depending on the tear site
Purpose To compare the effect of the lateral meniscus (LM) complete radial tear at different tear sites on the load distribution and transmission functions. Methods A compressive load of 300 N was applied to the intact porcine knees ( n  = 30) at 15°, 30°, 60°, 90°, and 120° of flexion. The LM complete radial tears were created at the middle portion (group M), the posterior portion (group P), or the posterior root (group R) ( n  = 10, each group), and the same loading procedure was followed. Finally, the recorded three-dimensional paths were reproduced on the LM-removed knees. The peak contact pressure (contact area) in the lateral compartment and the calculated in situ force of the LM under the principle of superposition were compared among the four groups (intact, group M, group P, and group R). Results At all the flexion angles, the peak contact pressure (contact area) was significantly higher (lower) after creating the LM complete radial tear as compared to that in the intact state ( p  < 0.01). At 120° of flexion, group R represented the highest peak contact pressure (lowest contact area), followed by group P and group M ( p  < 0.05). The results of the in situ force carried by the LM were similar to those of the tibiofemoral contact mechanics. Conclusion The detrimental effect of the LM complete radial tear on the load distribution and transmission functions was greatest in the posterior root tear, followed by the posterior portion tear and the middle portion tear in the deep-flexed position. Complete radial tars of the meniscus, especially at the posterior root, should be repaired to restore the biomechanical function.
A longitudinal tear in the medial meniscal body decreased the in situ meniscus force under an axial load
Purpose To clarify the effect of longitudinal tears of the medial meniscus on the in situ meniscus force and the tibiofemoral relationship under axial load. Methods Twenty-one intact porcine knees were mounted on a 6-degrees of freedom robotic system, and the force and three-dimensional path of the knee joints were recorded during three cycles under a 250-N axial load at 30°, 60°, 90° and 120° of knee flexion. They were divided into three groups of seven knees with longitudinal tears in the middle to the posterior segment of the medial meniscus based on the tear site: rim, outer one-third and inner one-third of the meniscal body. After creating tears, the same tests were performed. Finally, all paths were reproduced after total medial meniscectomy, and the in situ force of the medial meniscus was calculated based on the principle of superposition. Results With a longitudinal tear, the in situ force of the medial meniscus was significantly decreased at 60°, 90° and 120° of knee flexion, regardless of the tear site. The decrement was greater with a tear in the meniscal body than a tear in the rim. A longitudinal tear in the meniscal body caused a significantly greater tibial varus rotation than a tear in the rim at all flexion angles. Conclusion Longitudinal tears significantly decreased the in situ force of the medial meniscus. Tears in the meniscal body caused a larger decrease of the in situ meniscus force and greater varus tibial rotation than tears in the rim.
Effect of radial meniscal tear on in situ forces of meniscus and tibiofemoral relationship
Purpose To clarify the effect of the radial tear of the lateral meniscus on the in situ meniscus force and the tibiofemoral relationship under axial loads and valgus torques. Methods Ten intact porcine knees were settled to a 6-degree of freedom robotic system, while the force and 3-dimensional path of the knees were recorded via Universal Force Sensor (UFS) during 3 cycles of 250-N axial load and 5-Nm valgus torque at 15°, 30°, 45°, and 60° of knee flexion. The same examination was performed on the following 3 meniscal states sequentially; 33, 66, and 100% width of radial tears at the middle segment of the lateral meniscus, while recording the force and path of the knees via UFS. Finally, all paths were reproduced after total lateral meniscectomy and the in situ force of the lateral meniscus were calculated with the principle of superposition. Results The radial tear of 100% width significantly decreased the in situ force of the lateral meniscus and caused tibial medial shift and valgus rotation at 30°–60° of knee flexion in both testing protocols. Under a 250-N axial load at 60° of knee flexion, the in situ force decreased to 36 ± 29 N with 100% width of radial tear, which was 122 ± 38 N in the intact state. Additionally, the tibia shifted medially by 2.1 ± 0.9 mm and valgusrotated by 2.5 ± 1.9° with the complete radial tear. However, the radial tear of 33 or 66% width had little effect on either the in situ force or the tibial position. Conclusion A radial tear of 100% width involving the rim significantly decreased the in situ force of the lateral meniscus and caused medial shift and valgus rotation of the tibia, whereas a radial tear of up to 66% width produced only little change. The clinical relevance is that loss of meniscal functions due to complete radial tear can lead to abnormal stress concentration in a focal area of cartilage and can increase the risk of osteoarthritis in the future.
Complementary Function of the Meniscofemoral Ligament and Lateral Meniscus Posterior Root to Stabilize the Lateral Meniscus Posterior Horn: A Biomechanical Study in a Porcine Knee Model
Background: It has been demonstrated that the load distribution function of the lateral meniscus (LM) is compromised by resecting both the meniscofemoral ligament (MFL) and LM posterior root (LMPR). However, the effect of resecting these fibers on load transmission through the LM needs to be investigated. Purpose: To evaluate using a porcine knee model (1) the in situ forces of the MFL and LMPR and (2) the effect of resecting these fibers on the in situ force of the LM under a compressive load and valgus torque to the lateral knee compartment. Study Design: Controlled laboratory study. Methods: Twenty fresh-frozen porcine knees and a 6 degrees of freedom robotic system were utilized. An axial compressive load of 250 N and 5 N·m of valgus torque were applied to intact, MFL-deficient, LMPR-deficient, and MFL/LMPR-deficient knees at 30°, 60°, and 90° of flexion. The valgus angles under the applied loads were compared among the 4 states. The in situ forces of the MFL and LMPR under the applied loads were calculated under the principle of superposition. The in situ forces of the LM under the applied loads were also calculated and compared among the 4 conditions (intact, without the MFL, without LMPR, and without the MFL/LMPR). Results: The valgus angles significantly increased after resecting both the MFL and LMPR at all the flexion angles. The in situ forces of the MFL and LMPR changed reciprocally as the knee flexed. The in situ forces of the LM significantly decreased after resecting both the MFL and LMPR, although resecting only the MFL or LMPR represented no significant effect. Conclusion: The MFL and LMPR functioned complementarily as the posterior attachments of the LM against a compressive load and valgus torque to the lateral knee compartment in porcine knee joints. Clinical Relevance: If the LMPR is completely detached and needs to be repaired, the MFL should be preserved because it may provide some stability to the LM posterior horn and protect the repaired LMPR.
Reduction of in situ force through the meniscus with phased inner resection of medial meniscus: an experimental study in a porcine model
Purpose Partial meniscectomy can cause osteoarthritic changes in knees, as inner portion as well as peripheral portion of meniscus is important. The hypothesis of this study was that the amount of the inner resection of medial meniscus affected the in situ forces through the meniscus and the tibial varus and external rotation under axial load. Methods Fourteen intact porcine knees were investigated with a six-degree of freedom robotic system and force/moment, and the three-dimensional path of intact knees were recorded by universal force sensor when an axial load of 300-N was applied at four different flexion angles (30°, 60°, 90°, and 120°). The same examination was performed on three phased inner resections (30%, 60%, and 90% width) of the medial meniscus. Finally, all paths were reproduced after total medial meniscectomy, and in situ forces of the medial meniscus were calculated based on the superposition principle. Changes in tibiofemoral varus/valgus and internal/external rotation alignment during an axial load were also calculated. Results In situ forces of the medial meniscus decreased according to the amount of meniscal resection at all flexion angles. The reduction was significant in knees with inner resections of > 60% width at all flexion angles and even of 30% width at a flexion angle of 120° ( p  < .05). Incremental changes in the tibiofemoral varus alignment increased depending on the inner resection width at all flexion angles ( p  < .05). Conclusion The amount of inner resection of the medial meniscus was related to reduction of its in situ forces and increment of the tibial varus rotation under axial load.
Characteristics of ultrasound device: a new technology for bone curettage and excavation
Background Ultrasonic (US) devices are used in laparoscopic, dental, and spinal surgeries, while it is difficult to use for the joint under irrigation and perfusion solutions due to lack of power. A new US device is developed with greater voltage improvement and has been implemented in the arthroscopic field. The aim is to compare the characteristics of the US devices with the conventional ones in water. Methods Twenty bone blocks from the porcine femur were settled in a holder in water. A 4.0 mm diameter abrader burr moved 15 mm along the long axis of the bone block in ten blocks for three times. A 4.3 mm wide curette blade powered by ultrasonic vibration was moved in the same manner in the other ten blocks. The gutter shape, including the gutter depth and the bottom angle of the gutter, and the curetted area ratio of the gutter were assessed. Forty bones blocks from the porcine femurs were clamped with a holder in water, while the cortical bone surface must be located on the side. A 5 mm diameter drill excavated the bone along the previously-inserted guide wire to the 15 mm depth for twenty blocks. Next, the US excavation probe of 5x4mm rectangular shape was moved to the same depth in the other twenty blocks. Each ten block was cut in half along the bone tunnel and was assessed the surface roughness at three area, while the cross-sectional area (CSA) of the tunnel were measured and the ratio of the measured CSA was calculated based on an expected CSA in the remaining ten blocks for each device. Results The depth of curettage and bottom angle were significantly smaller with the US device than with the abrader burr at all planes, while the curetted area ratio created by each device was mostly equal to the other. Surface roughness was similar in two evacuating devices except one area. CSA ratio with the US excavation device was significantly smaller than that with the drill. Conclusion US curettage has an advantage to flatly curette bone surfaces, while a bone tunnel can be accurately created with the US device.
Morphological changes in tibial tunnels after anatomic anterior cruciate ligament reconstruction with hamstring tendon graft
Background Three-dimensional (3D) reconstructed computed tomography (CT) is crucial for the reliable and accurate evaluation of tunnel enlargement after anterior cruciate ligament (ACL) reconstruction. The purposes of this study were to evaluate the tibial tunnel enlargement at the tunnel aperture and inside the tunnel and to clarify the morphological change at the tunnel footprint 1 year after the anatomic triple-bundle (ATB) ACL reconstruction using 3D CT models. Methods Eighteen patients with unilateral ACL rupture were evaluated. The ATB ACL reconstruction with a semitendinosus tendon autograft was performed. 3D computer models of the tibia and the three tibial tunnels were reconstructed from CT data obtained 3 weeks and 1 year after surgery. The cross-sectional areas (CSAs) of the two anterior and the one posterior tunnels were measured at the tunnel aperture and 5 and 10 mm distal from the aperture and compared between the two periods. The locations of the center and the anterior, posterior, medial, and lateral edges of each tunnel footprint were also measured and compared between the two periods. Results The CSA of the posterior tunnel was significantly enlarged at the aperture by 40.4%, whereas that of the anterior tunnels did not change significantly, although the enlargement rate was 6.1%. On the other hand, the CSA was significantly reduced at 10 mm distal from the aperture in the anterior tunnels. The enlargement rate in the posterior tunnel was significantly greater than that in the anterior tunnels at the aperture. The center of the posterior tunnel footprint significantly shifted postero-laterally. The anterior and posterior edges of the posterior tunnel footprint demonstrated a significant posterior shift, while the lateral edge significantly shifted laterally. There was no significant shift of the center or all the edges of the anterior tunnels footprint. Conclusions The posterior tibial tunnel was significantly enlarged at the aperture by 40% with the morphological change in the postero-lateral direction reflected by the ACL fiber orientation 1 year after the ATB ACL reconstruction. The proper tibial tunnel location in the ACL reconstruction should be determined considering the tunnel enlargement in postero-lateral direction after surgery.
Varus-valgus instability in the anterior cruciate ligament-deficient knee: effect of posterior tibial load
Background Anterior cruciate ligament (ACL) injury is often accompanied with medial collateral ligament (MCL) injury. Assessment of varus-valgus (V-V) instability in the ACL-deficient knee is crucial for the management of the concomitant ACL-collateral ligaments injury. We evaluated the V-V laxity and investigated the effect of additional posterior tibial load on the laxity in the ACL-deficient knee. Our hypothesis was that the V-V laxity in the ACL-deficient knee was greater than that in the intact knee and attenuated by additional posterior tibial load. Methods Eight fresh-frozen porcine knees were used, and a 6°-of-freedom (DOF) robotic system was utilized. A 5 Nm of V-V torque was applied to the intact knee, the ACL-deficient knee, and the ACL-deficient knee with 30 N of constant posterior tibial load, at 30° and 60° of flexion. Then, the 3D path in the intact knee was reproduced on the ACL-deficient knee. The total V-V angle under 5 Nm of V-V torque was assessed and compared among the three statuses. The in situ forces of the ACL under 5 Nm of varus and valgus torques, respectively, were also calculated. Results The total V-V angle in the ACL-deficient knee under 5 Nm of V-V torque was significantly greater than that in the intact knee, whereas the angle in the ACL-deficient knee with 30 N of posterior tibial load was significantly smaller than that in the ACL-deficient knee and approached that in the intact knee, at both 30° and 60° of flexion. The in situ force of the ACL was approximately 30 N at 30° and 16 N at 60° of flexion under 5 Nm of both varus and valgus torques. Conclusions The V-V laxity in the isolated ACL-deficient knee was greater than that in the intact knee. The increased laxity was attenuated and approached that in the intact knee by adding posterior tibial load. Application of posterior tibial load is necessary for accurate assessment of V-V instability in the ACL-deficient knee. Clinically, the V-V laxity in the combined ACL-MCL or ACL-LCL injured knee may be overestimated without posterior tibial load.
Novel flat and wide meniscal repair material improves the ultimate load of knot breakage in a porcine trans-capsular meniscal repair model
Background In the meniscal repair procedures, a high ultimate load capacity and low cyclic creep at the repair site are favorable and lead to good biological incorporation of the tear site after surgery. Previous biomechanical tensile tests of the meniscal sutures have identified the suture knot as the weakest point. We hypothesized that the strength of a suture knot depends on the suture shape, and therefore, we compared three differently shaped suture materials composed of the same material and quantity per length. The purpose of this study was to determine whether a novel flat and wide repair material (FWRM), which consists of braided multi-threads that are cross-sectionally flat and wide, improves the ultimate load of knot breakage in a biomechanical experiment using a porcine trans-capsular meniscal repair model. Methods Eighteen fresh-frozen porcine knees ( n  = 6 in each group) were used. A longitudinal tear in the middle segment of the medial meniscus was created and repaired with a trans-capsular inside-out method using the following suture materials: No. 2–0 braided polyester conventional suture, hollow suture, and FWRM. After the separation of the inner segment of the meniscus with leaving, the suture stability of the repaired menisci was biomechanically analyzed with a video camera system for widening after a cyclic load between 5 and 20 N was applied 300 times. Ultimate failure load and stiffness at 5 mm/ min were also analyzed. Results We found no significant difference in suture widening after cyclic load tests [conventional suture, mean 0.51 mm (S.D. 0.39 mm); hollow suture, mean 0.23 mm (S.D. 0.11 mm); and FWRM, mean 0.54 mm (S.D. 0.08 mm)]. The failure mode in all specimens was knot breakage. Compared with those of the other groups, the ultimate failure load of FWRM was statistically significantly higher in the load-to-failure tests (conventional suture, mean 58.8 N [S.D. 8.25 N]; hollow suture, mean 79.4 N [S.D. 10.2 N]; and FWRM, mean 97.4 N [S.D. 3.65 N]; p  < 0.05). Conclusion FWRM improves the ultimate load of knot breakage without altering stability. This material may contribute to safe and stable meniscus repair.
800 EP058 – Assessing knee kinematics relationship between modified drop squat and running after anterior cruciate reconstruction
BackgroundAsymmetry in knee joint kinematics during running after anterior cruciate ligament reconstruction (ACLR) could indicate insufficient recovery of knee functions and might lead to re-injury or secondary knee osteoarthritis. We developed ‘Modified Drop Squat’ (MDS) exercise to assess and improve the asymmetry of knee kinematics during running after ACLR.ObjectiveTo investigate the utility of MDS exercise for detecting altered knee kinematics during running after ACLR.DesignA cross-sectional observational clinical design.SettingClinical laboratory in a hospital’s physical therapy department.PatientsThirty-seven patients after ACLR (22 males, 15 females; average age of 24.5 ± 10.1 years) were included and assessed at 3 months after surgery.InterventionsThe patients performed MDS exercise with a quick knee flexion from standing on tiptoe to squatting down with 40 degrees of flexion on the affected leg, in addition to running with a comfortable pace. Both angular velocity of knee flexion in MDS and knee flexion angle (KFA) during running were analyzed with a video analysis.Main Outcome MeasurementsThe deficit of the peak flexion angular velocity in MDS and the side-to-side difference (SSD) of the maximum KFA during running were calculated. Spearman's rank correlation analysis evaluated the relationship between the two values.ResultsA strong correlation (r=0.82, p<0.05) was identified between the peak flexion angular velocity in MDS and the SSD of the maximum KFA during running.ConclusionsAssessing the peak flexion angular velocity in MDS effectively detected asymmetry in knee joint kinematics during running after ACLR. This approach has a potential for identifying the risk of re-injuries after ACLR and might contribute to prevention re-injury or secondary knee osteoarthritis. Further research is needed to validate these findings for clinical application.