Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
12 result(s) for "Triantafyllou, Matthaios"
Sort by:
Ultrasound radiomics predict the success of US-guided percutaneous irrigation for shoulder calcific tendinopathy
Objective Calcific tendinopathy, predominantly affecting rotator cuff tendons, leads to significant pain and tendon degeneration. Although US-guided percutaneous irrigation (US-PICT) is an effective treatment for this condition, prediction of patient’ s response and long-term outcomes remains a challenge. This study introduces a novel radiomics-based model to forecast patient outcomes, addressing a gap in the current predictive methodologies. Materials and methods The study involved 84 patients who underwent US-PICT, with data collected on clinical and demographic factors, alongside radiomic features extracted from ultrasound images. Key radiomic features predictive of the outcome were discerned through Least Absolute Shrinkage and Selection Operator (LASSO) method. Machine Learning models, including Random Forest, XGBoost, and Support Vector Machines, were employed to analyze the radiomics, the clinical and the combined dataset, focusing on calcium removal extent. An external testing was conducted using an independent cohort from a different institution to assess the model’s generalizability. Metrics were calculated for the best-performing models, namely area under the curve (AUC) score, sensitivity, specificity, precision or positive predictive value, and negative predictive value. Results The selected features were merged with clinical data, notably the calcification’s maximum diameter. This enriched dataset was fed into classification models. The superior model achieved an AUC of 0.88 (95% CI 0.73–0.99), with a positive predictive value of 0.92 and a sensitivity of 0.90. In external testing, the combined model achieved an AUC of 0.78. SHAP analysis was employed to highlight the impact of the selected features on the optimal model’s effectiveness. Conclusion The developed radiomics model offers a promising tool for predicting outcomes of US-PICT, potentially guiding clinical decision-making.
Explanation and Elaboration with Examples for CLEAR (CLEAR-E3): an EuSoMII Radiomics Auditing Group Initiative
Overall quality of radiomics research has been reported as low in literature, which constitutes a major challenge to improve. Consistent, transparent, and accurate reporting is critical, which can be accomplished with systematic use of reporting guidelines. The CheckList for EvaluAtion of Radiomics research (CLEAR) was previously developed to assist authors in reporting their radiomic research and to assist reviewers in their evaluation. To take full advantage of CLEAR, further explanation and elaboration of each item, as well as literature examples, may be useful. The main goal of this work, Explanation and Elaboration with Examples for CLEAR (CLEAR-E3), is to improve CLEAR’s usability and dissemination. In this international collaborative effort, members of the European Society of Medical Imaging Informatics−Radiomics Auditing Group searched radiomics literature to identify representative reporting examples for each CLEAR item. At least two examples, demonstrating optimal reporting, were presented for each item. All examples were selected from open-access articles, allowing users to easily consult the corresponding full-text articles. In addition to these, each CLEAR item’s explanation was further expanded and elaborated. For easier access, the resulting document is available at https://radiomic.github.io/CLEAR-E3/ . As a complementary effort to CLEAR, we anticipate that this initiative will assist authors in reporting their radiomics research with greater ease and transparency, as well as editors and reviewers in reviewing manuscripts. Relevance statement  Along with the original CLEAR checklist, CLEAR-E3 is expected to provide a more in-depth understanding of the CLEAR items, as well as concrete examples for reporting and evaluating radiomic research. Key points • As a complementary effort to CLEAR, this international collaborative effort aims to assist authors in reporting their radiomics research, as well as editors and reviewers in reviewing radiomics manuscripts. • Based on positive examples from the literature selected by the EuSoMII Radiomics Auditing Group, each CLEAR item explanation was further elaborated in CLEAR-E3. • The resulting explanation and elaboration document with examples can be accessed at  https://radiomic.github.io/CLEAR-E3/ . Graphical Abstract
Explanation and Elaboration with Examples for METRICS (METRICS-E3): an initiative from the EuSoMII Radiomics Auditing Group
Radiomics research has been hindered by inconsistent and often poor methodological quality, limiting its potential for clinical translation. To address this challenge, the METhodological RadiomICs Score (METRICS) was recently introduced as a tool for systematically assessing study rigor. However, its effective application requires clearer guidance. The METRICS-E3 (Explanation and Elaboration with Examples) resource was developed by the European Society of Medical Imaging Informatics—Radiomics Auditing Group in response. This international initiative provides comprehensive support for users by offering detailed rationales, interpretive guidance, scoring recommendations, and illustrative examples for each METRICS item and condition. Each criterion includes positive examples from peer-reviewed, open-access studies and hypothetical negative examples. In total, the finalized METRICS-E3 includes over 200 examples. The complete resource is publicly available through an interactive website. Critical relevance statement METRICS-E3 offers deeper insights into each METRICS item and condition, providing concrete examples with accompanying commentary and recommendations to enhance the evaluation of methodological quality in radiomics research. Key Points As a complementary initiative to METRICS, METRICS-E3 is intended to support stakeholders in evaluating the methodological aspects of radiomics studies. In METRICS-E3, each METRICS item and condition is supplemented with interpretive guidance, positive literature-based examples, hypothetical negative examples, and scoring recommendations. The complete METRICS-E3 explanation and elaboration resource is accessible at its interactive website. Graphical Abstract
Radiomics Analysis for Multiple Myeloma: A Systematic Review with Radiomics Quality Scoring
Multiple myeloma (MM) is one of the most common hematological malignancies affecting the bone marrow. Radiomics analysis has been employed in the literature in an attempt to evaluate the bone marrow of MM patients. This manuscript aimed to systematically review radiomics research on MM while employing a radiomics quality score (RQS) to accurately assess research quality in the field. A systematic search was performed on Web of Science, PubMed, and Scopus. The selected manuscripts were evaluated (data extraction and RQS scoring) by three independent readers (R1, R2, and R3) with experience in radiomics analysis. A total of 23 studies with 2682 patients were included, and the median RQS was 10 for R1 (IQR 5.5–12) and R3 (IQR 8.3–12) and 11 (IQR 7.5–12.5) for R2. RQS was not significantly correlated with any of the assessed bibliometric data (impact factor, quartile, year of publication, and imaging modality) (p > 0.05). Our results demonstrated the low quality of published radiomics research in MM, similarly to other fields of radiomics research, highlighting the need to tighten publication standards.
Radiomics for the Detection of Active Sacroiliitis Using MR Imaging
Detecting active inflammatory sacroiliitis at an early stage is vital for prescribing medications that can modulate disease progression and significantly delay or prevent debilitating forms of axial spondyloarthropathy. Conventional radiography and computed tomography offer limited sensitivity in detecting acute inflammatory findings as these methods primarily identify chronic structural lesions. Conversely, Magnetic Resonance Imaging (MRI) is the preferred technique for detecting bone marrow edema, although it is a complex process requiring extensive expertise. Additionally, ascertaining the origin of lesions can be challenging, even for experienced medical professionals. Machine learning (ML) has showcased its proficiency in various fields by uncovering patterns that are not easily perceived from multi-dimensional datasets derived from medical imaging. The aim of this study is to develop a radiomic signature to aid clinicians in diagnosing active sacroiliitis. A total of 354 sacroiliac joints were segmented from axial fluid-sensitive MRI images, and their radiomic features were extracted. After selecting the most informative features, a number of ML algorithms were utilized to identify the optimal method for detecting active sacroiliitis, leading to the selection of an Extreme Gradient Boosting (XGBoost) model that accomplished an Area Under the Receiver-Operating Characteristic curve (AUC-ROC) of 0.71, thus further showcasing the potential of radiomics in the field.
Prostate cancer MRI methodological radiomics score: a EuSoMII radiomics auditing group initiative
Objectives To evaluate the quality of radiomics research in prostate MRI for the evaluation of prostate cancer (PCa) through the assessment of METhodological RadiomICs (METRICS) score, a new scoring tool recently introduced with the goal of fostering further improvement in radiomics and machine learning methodology. Materials and methods A literature search was conducted from July 1st, 2019, to November 30th, 2023, to identify original investigations assessing MRI-based radiomics in the setting of PCa. Seven readers with varying expertise underwent a quality assessment using METRICS. Subgroup analyses were performed to assess whether the quality score varied according to papers’ categories (diagnosis, staging, prognosis, technical) and quality ratings among these latter. Results From a total of 1106 records, 185 manuscripts were available. Overall, the average METRICS total score was 52% ± 16%. ANOVA and chi-square tests revealed no statistically significant differences between subgroups. Items with the lowest positive scores were adherence to guidelines/checklists (4.9%), handling of confounding factors (14.1%), external testing (15.1%), and the availability of data (15.7%), code (4.3%), and models (1.6%). Conversely, most studies clearly defined patient selection criteria (86.5%), employed a high-quality reference standard (89.2%), and utilized a well-described (85.9%) and clinically applicable (87%) imaging protocol as a radiomics data source. Conclusion The quality of MRI-based radiomics research for PCa in recent studies demonstrated good homogeneity and overall moderate quality. Key Points Question To evaluate the quality of MRI-based radiomics research for PCa, assessed through the METRICS score . Findings The average METRICS total score was 52%, reflecting moderate quality in MRI-based radiomics research for PCa, with no statistically significant differences between subgroups . Clinical relevance Enhancing the quality of radiomics research can improve diagnostic accuracy for PCa, leading to better patient outcomes and more informed clinical decision-making .
Ultrasound-Guided Glenohumeral Joint Injection using a Modified Posterior Approach
Glenohumeral joint injections serve diagnostic and therapeutic purposes in a wide spectrum of shoulder disorders. Various techniques have been described, depending on the injection site, needle orientation and utilisation of image or landmark-based guidance. The accuracy of needle placement and clinical effectiveness vary by the injection route and the method of guidance and largely depend on operator's expertise, clinical indication and patient's profile. Herein, we describe an alternative ultrasound-guided glenohumeral joint injection technique through a modified posterior approach for routine use in clinical practice.
OpenRad: a Curated Repository of Open-access AI models for Radiology
The rapid developments in artificial intelligence (AI) research in radiology have produced numerous models that are scattered across various platforms and sources, limiting discoverability, reproducibility and clinical translation. Herein, OpenRad was created, a curated, standardized, open-access repository that aggregates radiology AI models and providing details such as the availability of pretrained weights and interactive applications. Retrospective analysis of peer reviewed literature and preprints indexed in PubMed, arXiv and Scopus was performed until Dec 2025 (n = 5239 records). Model records were generated using a locally hosted LLM (gpt-oss:120b), based on the RSNA AI Roadmap JSON schema, and manually verified by ten expert reviewers. Stability of LLM outputs was assessed on 225 randomly selected papers using text similarity metrics. A total of 1694 articles were included after review. Included models span all imaging modalities (CT, MRI, X-ray, US) and radiology subspecialties. Automated extraction demonstrated high stability for structured fields (Levenshtein ratio > 90%), with 78.5% of record edits being characterized as minor during expert review. Statistical analysis of the repository revealed CNN and transformer architectures as dominant, while MRI was the most commonly used modality (in 621 neuroradiology AI models). Research output was mostly concentrated in China and the United States. The OpenRad web interface enables model discovery via keyword search and filters for modality, subspecialty, intended use, verification status and demo availability, alongside live statistics. The community can contribute new models through a dedicated portal. OpenRad contains approx. 1700 open access, curated radiology AI models with standardized metadata, supplemented with analysis of code repositories, thereby creating a comprehensive, searchable resource for the radiology community.
PARROT: An Open Multilingual Radiology Reports Dataset
Rationale and Objectives: To develop and validate PARROT (Polyglottal Annotated Radiology Reports for Open Testing), a large, multicentric, open-access dataset of fictional radiology reports spanning multiple languages for testing natural language processing applications in radiology. Materials and Methods: From May to September 2024, radiologists were invited to contribute fictional radiology reports following their standard reporting practices. Contributors provided at least 20 reports with associated metadata including anatomical region, imaging modality, clinical context, and for non-English reports, English translations. All reports were assigned ICD-10 codes. A human vs. AI report differentiation study was conducted with 154 participants (radiologists, healthcare professionals, and non-healthcare professionals) assessing whether reports were human-authored or AI-generated. Results: The dataset comprises 2,658 radiology reports from 76 authors across 21 countries and 13 languages. Reports cover multiple imaging modalities (CT: 36.1%, MRI: 22.8%, radiography: 19.0%, ultrasound: 16.8%) and anatomical regions, with chest (19.9%), abdomen (18.6%), head (17.3%), and pelvis (14.1%) being most prevalent. In the differentiation study, participants achieved 53.9% accuracy (95% CI: 50.7%-57.1%) in distinguishing between human and AI-generated reports, with radiologists performing significantly better (56.9%, 95% CI: 53.3%-60.6%, p<0.05) than other groups. Conclusion: PARROT represents the largest open multilingual radiology report dataset, enabling development and validation of natural language processing applications across linguistic, geographic, and clinical boundaries without privacy constraints.
Performance and evaluation of a coupled prognostic model TAPM over a mountainous complex terrain industrial area
Atmospheric modeling is considered an important tool with several applications such as prediction of air pollution levels, air quality management, and environmental impact assessment studies. Therefore, evaluation studies must be continuously made, in order to improve the accuracy and the approaches of the air quality models. In the present work, an attempt is made to examine the air pollution model (TAPM) efficiency in simulating the surface meteorology, as well as the SO2 concentrations in a mountainous complex terrain industrial area. Three configurations under different circumstances, firstly with default datasets, secondly with data assimilation, and thirdly with updated land use, ran in order to investigate the surface meteorology for a 3-year period (2009–2011) and one configuration applied to predict SO2 concentration levels for the year of 2011.The modeled hourly averaged meteorological and SO2 concentration values were statistically compared with those from five monitoring stations across the domain to evaluate the model’s performance. Statistical measures showed that the surface temperature and relative humidity are predicted well in all three simulations, with index of agreement (IOA) higher than 0.94 and 0.70 correspondingly, in all monitoring sites, while an overprediction of extreme low temperature values is noted, with mountain altitudes to have an important role. However, the results also showed that the model’s performance is related to the configuration regarding the wind. TAPM default dataset predicted better the wind variables in the center of the simulation than in the boundaries, while improvement in the boundary horizontal winds implied the performance of TAPM with updated land use. TAPM assimilation predicted the wind variables fairly good in the whole domain with IOA higher than 0.83 for the wind speed and higher than 0.85 for the horizontal wind components. Finally, the SO2 concentrations were assessed by the model with IOA varied from 0.37 to 0.57, mostly dependent on the grid/monitoring station of the simulated domain. The present study can be used, with relevant adaptations, as a user guideline for future conducting simulations in mountainous complex terrain.