Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
117
result(s) for
"U. G. Oberlack"
Sort by:
Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of 136Xe
2020
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of
136
Xe. Out of its 50 t total natural xenon inventory, 40 t will be the active target of a time projection chamber which thus contains about 3.6 t of
136
Xe. Here, we show that its projected half-life sensitivity is
2.4
×
10
27
year
, using a fiducial volume of 5 t of natural xenon and 10 year of operation with a background rate of less than 0.2 events/(t
·
year) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in
136
Xe.
Journal Article
Erratum to: Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of 136Xe
by
Rupp, N.
,
Clark, M.
,
Oberlack, U. G.
in
Astronomy
,
Astrophysics and Cosmology
,
Elementary Particles
2023
We correct an overestimation of the production rate of
137
Xe in the DARWIN detector operated at LNGS. This formerly dominant intrinsic background source is now at a level similar to the irreducible background from solar
8
B neutrinos, thus unproblematic at the LNGS depth. The projected half-life sensitivity for the neutrinoless double beta decay (
0
ν
β
β
) of
136
Xe improves by
22
%
compared to the previously reported number and is now
T
1
/
2
0
ν
=
3.0
×
10
27
yr
(90% C.L.) after 10 years of DARWIN operation.
Journal Article
Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of$$^{136}$$ Xe
2020
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of$$^{136}$$136 Xe. Out of its 50 t total natural xenon inventory, 40 t will be the active target of a time projection chamber which thus contains about 3.6 t of$$^{136}$$136 Xe. Here, we show that its projected half-life sensitivity is$$2.4\\times {10}^{27}\\,{\\hbox {year}}$$2.4 × 10 27 year , using a fiducial volume of 5 t of natural xenon and 10 year of operation with a background rate of less than 0.2 events/(t $$\\cdot $$· year) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in$$^{136}$$136 Xe.
Journal Article
Solar neutrino detection sensitivity in DARWIN via electron scattering
2020
We detail the sensitivity of the proposed liquid xenon DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components:
pp
,
7
Be,
13
N,
15
O and
pep
. The precision of the
13
N,
15
O and
pep
components is hindered by the double-beta decay of
136
Xe and, thus, would benefit from a depleted target. A high-statistics observation of
pp
neutrinos would allow us to infer the values of the electroweak mixing angle,
sin
2
θ
w
, and the electron-type neutrino survival probability,
P
ee
, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, with 10 live years of data and a 30 tonne fiducial volume. An observation of
pp
and
7
Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high- (GS98) and low-metallicity (AGS09) solar models with 2.1–2.5
σ
significance, independent of external measurements from other experiments or a measurement of
8
B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of
131
Xe.
Journal Article
Cosmogenic background simulations for neutrinoless double beta decay with the DARWIN observatory at various underground sites
2024
Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With
40
t
of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay (
0
ν
β
β
), and axion-like particles (ALPs). Although cosmic muons are a source of background that cannot be entirely eliminated, they may be greatly diminished by placing the detector deep underground. In this study, we used Monte Carlo simulations to model the cosmogenic background expected for the DARWIN observatory at four underground laboratories: Laboratori Nazionali del Gran Sasso (LNGS), Sanford Underground Research Facility (SURF), Laboratoire Souterrain de Modane (LSM) and SNOLAB. We present here the results of simulations performed to determine the production rate of
137
Xe, the most crucial isotope in the search for
0
ν
β
β
of
136
Xe. Additionally, we explore the contribution that other muon-induced spallation products, such as other unstable xenon isotopes and tritium, may have on the cosmogenic background.
Journal Article
Erratum to: Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of$$^{136}$$ Xe
2023
We correct an overestimation of the production rate of$$^{137}$$137 Xe in the DARWIN detector operated at LNGS. This formerly dominant intrinsic background source is now at a level similar to the irreducible background from solar$$^8$$8 B neutrinos, thus unproblematic at the LNGS depth. The projected half-life sensitivity for the neutrinoless double beta decay ($$0\\nu \\beta \\beta $$0 ν β β ) of$$^{136}$$136 Xe improves by$$22\\%$$22 % compared to the previously reported number and is now$$T^{0\\nu }_{1/2}= {3.0\\times 10^{27}} \\hbox { yr}$$T 1 / 2 0 ν = 3.0 × 10 27 yr (90% C.L.) after 10 years of DARWIN operation.
Journal Article
Cosmogenic background simulations for the DARWIN observatory at different underground locations
2023
Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay (\\(0\\nu\\beta\\beta\\)), and axion-like particles (ALPs). Although cosmic muons are a source of background that cannot be entirely eliminated, they may be greatly diminished by placing the detector deep underground. In this study, we used Monte Carlo simulations to model the cosmogenic background expected for the DARWIN observatory at four underground laboratories: Laboratori Nazionali del Gran Sasso (LNGS), Sanford Underground Research Facility (SURF), Laboratoire Souterrain de Modane (LSM) and SNOLAB. We determine the production rates of unstable xenon isotopes and tritium due to muon-included neutron fluxes and muon-induced spallation. These are expected to represent the dominant contributions to cosmogenic backgrounds and thus the most relevant for site selection.
Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of¹³⁶136 Xe
2020
Abstract The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of¹³⁶136 Xe. Out of its 50 t total natural xenon inventory, 40 t will be the active target of a time projection chamber which thus contains about 3.6 t of¹³⁶136 Xe. Here, we show that its projected half-life sensitivity is2.4× 10²⁷ \\hbox year2.4×1027year , using a fiducial volume of 5 t of natural xenon and 10 year of operation with a background rate of less than 0.2 events/(t ⋅ · year) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in¹³⁶136 Xe.
Journal Article
Erratum to: Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of¹³⁶136 Xe
2023
Abstract We correct an overestimation of the production rate of¹³⁷137 Xe in the DARWIN detector operated at LNGS. This formerly dominant intrinsic background source is now at a level similar to the irreducible background from solar⁸8 B neutrinos, thus unproblematic at the LNGS depth. The projected half-life sensitivity for the neutrinoless double beta decay (0ν β β 0 ν β β ) of¹³⁶136 Xe improves by22%22 % compared to the previously reported number and is nowT^(0ν)_(1/2)= 3.0× 10²⁷ \\hbox yrT 1 / 2 0 ν = 3.0 × 10 27 yr (90% C.L.) after 10 years of DARWIN operation.
Journal Article
Compton Imaging of MeV Gamma-Rays with the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)
2008
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is the first realization of a liquid xenon time projection chamber for Compton imaging of MeV gamma-ray sources in astrophysics. By measuring the energy deposit and the three spatial coordinates of individual gamma-ray scattering points, the location of the source in the sky is inferred with Compton kinematics reconstruction. The angular resolution is determined by the detector's energy and spatial resolutions, as well as by the separation in space between the first and second scattering. The imaging response of LXeGRIT was established with gamma-rays from radioactive sources, during calibration and integration at the Columbia Astrophysics Laboratory, prior to the 2000 balloon flight mission. In this paper we describe in detail the various steps involved in imaging sources with LXeGRIT and present experimental results on angular resolution and other parameters which characterize its performance as a Compton telescope.