Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
9 result(s) for "UMEDA Rumiko"
Sort by:
Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse : comparison with Fibroscan^○!R
Background Accurate evaluation of liver fibrosis in patients with chronic liver damage is required to determine the appropriate treatment. Various approaches, including laboratory tests and transient elastography, have been used to evaluate liver fibrosis. Recently, transient elastography with acoustic radiation force impulse (ARFI) has been developed and applied with conventional ultrasonography. The aim of this study was to evaluate the clinical utility of transient elastography with ARFI and to compare the results with this method and those of the Fibroscan ® procedure. Methods One hundred and thirty-one patients with liver damage, who underwent liver biopsy at our department, were enrolled prospectively in this study. Elastography with ARFI (applied with ACUSON S2000 ® ), and Fibroscan ® was performed at the same time as liver biopsy. These measurements were compared with histological findings in liver biopsy specimens, and measurement accuracy was evaluated by receiver-operating characteristic analysis. Results Elastography values with both procedures were significantly correlated with the stages of liver fibrosis and there was little difference in the results obtained using the 2 procedures. The accuracy of differential diagnosis between no fibrosis at F0 and more than F1 stage was insufficient with ARFI, but this procedure was sufficient for diagnosing advanced fibrosis. The accuracy of ARFI was almost equivalent to that of the Fibroscan ® method. Moreover, both ARFI and Fibroscan ® values increased in proportion to the severity of hepatic inflammation when fibrosis stage is low, but not in proportion to the severity of steatosis. Conclusions Transient elastography with ARFI is simple, non-invasive and useful for diagnosing the stage of fibrosis in chronic liver disease. The utility of ARFI was almost equivalent to that of the Fibroscan ® method.
Complete remission of peritoneal dissemination of colon cancer by alternate-day S-1 and oxaliplatin plus bevacizumab treatment and maintenance chemotherapy comprising alternate-day S-1 plus bevacizumab: A case report
A 56-year-old man diagnosed with sigmoid colon cancer underwent sigmoid colectomy. Nine months later, his serum carcinoembryonic antigen (CEA) level had increased, and the diagnosis of recurrent peritoneal dissemination was made based on positron emission tomography/computed tomography (PET/CT) findings. Although systemic chemotherapy comprising S-1 and oxaliplatin (SOX) plus bevacizumab was initiated, severe diarrhea occurred on day 4 of the second cycle despite reduction in S-1 dose. By changing the daily oral intake schedule for S-1 to an alternate-day intake from the third cycle (modified SOX plus bevacizumab), the patient was able to continue undergoing chemotherapy without any adverse gastrointestinal effects. All tumors disappeared after four cycles, and the patients received eight cycles of modified SOX plus bevacizumab followed by maintenance chemotherapy comprising alternate-day S-1 plus bevacizumab. Maintenance chemotherapy was discontinued after 17 cycles owing to adverse events, including thrombocytopenia, corneal and lacrimal duct disorders, and hyperbilirubinemia. The patient has been radiographically confirmed to be in remission for 5 years without any recurrence, and his serum CEA level has been within normal range for >3 years. To conclude, compared with the conventional consecutive treatment, alternate-day SOX plus bevacizumab treatment may reduce the adverse effects of these chemotherapeutic drugs.
Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan^sup ?
Accurate evaluation of liver fibrosis in patients with chronic liver damage is required to determine the appropriate treatment. Various approaches, including laboratory tests and transient elastography, have been used to evaluate liver fibrosis. Recently, transient elastography with acoustic radiation force impulse (ARFI) has been developed and applied with conventional ultrasonography. The aim of this study was to evaluate the clinical utility of transient elastography with ARFI and to compare the results with this method and those of the Fibroscan^sup ®^ procedure. One hundred and thirty-one patients with liver damage, who underwent liver biopsy at our department, were enrolled prospectively in this study. Elastography with ARFI (applied with ACUSON S2000^sup ®^), and Fibroscan^sup ®^ was performed at the same time as liver biopsy. These measurements were compared with histological findings in liver biopsy specimens, and measurement accuracy was evaluated by receiver-operating characteristic analysis. Elastography values with both procedures were significantly correlated with the stages of liver fibrosis and there was little difference in the results obtained using the 2 procedures. The accuracy of differential diagnosis between no fibrosis at F0 and more than F1 stage was insufficient with ARFI, but this procedure was sufficient for diagnosing advanced fibrosis. The accuracy of ARFI was almost equivalent to that of the Fibroscan^sup ®^ method. Moreover, both ARFI and Fibroscan^sup ®^ values increased in proportion to the severity of hepatic inflammation when fibrosis stage is low, but not in proportion to the severity of steatosis. Transient elastography with ARFI is simple, non-invasive and useful for diagnosing the stage of fibrosis in chronic liver disease. The utility of ARFI was almost equivalent to that of the Fibroscan^sup ®^ method.[PUBLICATION ABSTRACT]
Subacute postoperative myofascial pain diagnosed and treated successfully by ultrasound: a case after laparoscopic hepatectomy
Background Myofascial pain syndrome is one of the causes of prolonged postoperative pain after abdominal surgery. However, diagnosis and treatment of myofascial pain syndrome, especially its myofascial trigger point (MTrP), have not been well established. Case presentation A 55-year-old man experienced severe subacute abdominal pain after laparoscopic hepatectomy despite aggressive postoperative pain management. He had a positive Carnett’s sign, indicating abdominal wall pain, 2 weeks after the surgery. Ultrasonography showed a hyperechoic spot surrounded by a hypoechoic area in the inner abdominal oblique muscle under the palpable spot that fulfills the criteria of MTrP. The echogenic MTrP disappeared after repetitive ultrasound-guided trigger point injections (USG TPIs) with pain relief. Conclusions Our present case indicates that diagnosing myofascial pain by visualizing the echogenic MTrPs in the abdominal muscles, and subsequent USG TPIs, might provide an accurate maneuver for diagnosis and treatment of subacute myofascial pain after abdominal surgery.