Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
19 result(s) for "Valstar, Edward"
Sort by:
Effect of Alkali-Acid-Heat Chemical Surface Treatment on Electron Beam Melted Porous Titanium and Its Apatite Forming Ability
Advanced additive manufacturing techniques such as electron beam melting (EBM), can produce highly porous structures that resemble the mechanical properties and structure of native bone. However, for orthopaedic applications, such as joint prostheses or bone substitution, the surface must also be bio-functionalized to promote bone growth. In the current work, EBM porous Ti6Al4V alloy was exposed to an alkali acid heat (AlAcH) treatment to bio-functionalize the surface of the porous structure. Various molar concentrations (3, 5, 10M) and immersion times (6, 24 h) of the alkali treatment were used to determine optimal parameters. The apatite forming ability of the samples was evaluated using simulated body fluid (SBF) immersion testing. The micro-topography and surface chemistry of AlAcH treated samples were evaluated before and after SBF testing using scanning electron microscopy and energy dispersive X-ray spectroscopy. The AlAcH treatment successfully modified the topographical and chemical characteristics of EBM porous titanium surface creating nano-topographical features ranging from 200–300 nm in size with a titania layer ideal for apatite formation. After 1 and 3 week immersion in SBF, there was no Ca or P present on the surface of as manufactured porous titanium while both elements were present on all AlAcH treated samples except those exposed to 3M, 6 h alkali treatment. An increase in molar concentration and/or immersion time of alkali treatment resulted in an increase in the number of nano-topographical features per unit area as well as the amount of titania on the surface.
Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy
State-of-the-art fluoroscopic knee kinematic analysis methods require the patient-specific bone shapes segmented from CT or MRI. Substituting the patient-specific bone shapes with personalizable models, such as statistical shape models (SSM), could eliminate the CT/MRI acquisitions, and thereby decrease costs and radiation dose (when eliminating CT). SSM based kinematics, however, have not yet been evaluated on clinically relevant joint motion parameters. Therefore, in this work the applicability of SSMs for computing knee kinematics from biplane fluoroscopic sequences was explored. Kinematic precision with an edge based automated bone tracking method using SSMs was evaluated on 6 cadaveric and 10 in-vivo fluoroscopic sequences. The SSMs of the femur and the tibia–fibula were created using 61 training datasets. Kinematic precision was determined for medial–lateral tibial shift, anterior–posterior tibial drawer, joint distraction–contraction, flexion, tibial rotation and adduction. The relationship between kinematic precision and bone shape accuracy was also investigated. The SSM based kinematics resulted in sub-millimeter (0.48–0.81mm) and approximately 1° (0.69–0.99°) median precision on the cadaveric knees compared to bone-marker-based kinematics. The precision on the in-vivo datasets was comparable to that of the cadaveric sequences when evaluated with a semi-automatic reference method. These results are promising, though further work is necessary to reach the accuracy of CT-based kinematics. We also demonstrated that a better shape reconstruction accuracy does not automatically imply a better kinematic precision. This result suggests that the ability of accurately fitting the edges in the fluoroscopic sequences has a larger role in determining the kinematic precision than that of the overall 3D shape accuracy.
AQUILA: assessment of quality in lower limb arthroplasty. An expert Delphi consensus for total knee and total hip arthroplasty
Background In the light of both the importance and large numbers of case series and cohort studies (observational studies) in orthopaedic literature, it is remarkable that there is currently no validated measurement tool to appraise their quality. A Delphi approach was used to develop a checklist for reporting quality, methodological quality and generalizability of case series and cohorts in total hip and total knee arthroplasty with a focus on aseptic loosening. Methods A web-based Delphi was conducted consisting of two internal rounds and three external rounds in order to achieve expert consensus on items considered relevant for reporting quality, methodological quality and generalizability. Results The internal rounds were used to construct a master list. The first external round was completed by 44 experts, 35 of them completed the second external round and 33 of them completed the third external round. Consensus was reached on an 8-item reporting quality checklist, a 6-item methodological checklist and a 22-item generalizability checklist. Conclusions Checklist for reporting quality, methodological quality and generalizability for case series and cohorts in total hip and total knee arthroplasty were successfully created through this Delphi. These checklists should improve the accuracy, completeness and quality of case series and cohorts regarding total hip and total knee arthroplasty.
Marker Configuration Model-Based Roentgen Fluoroscopic Analysis
It remains unknown if and how the polyethylene bearing in mobile bearing knees moves during dynamic activities with respect to the tibial base plate. Marker Configuration Model-Based Roentgen Fluoroscopic Analysis (MCM-based RFA) uses a marker configuration model of inserted tantalum markers in order to accurately estimate the pose of an implant or bone using single plane Roentgen images or fluoroscopic images. The goal of this study is to assess the accuracy of (MCM-Based RFA) in a standard fluoroscopic set-up using phantom experiments and to determine the error propagation with computer simulations. The experimental set-up of the phantom study was calibrated using a calibration box equipped with 600 tantalum markers, which corrected for image distortion and determined the focus position. In the computer simulation study the influence of image distortion, MC-model accuracy, focus position, the relative distance between MC-models and MC-model configuration on the accuracy of MCM-Based RFA were assessed. The phantom study established that the in-plane accuracy of MCM-Based RFA is 0.1 mm and the out-of-plane accuracy is 0.9 mm. The rotational accuracy is 0.1°. A ninth-order polynomial model was used to correct for image distortion. Marker-Based RFA was estimated to have, in a worst case scenario, an in vivo translational accuracy of 0.14 mm ( x-axis), 0.17 mm ( y-axis), 1.9 mm ( z-axis), respectively, and a rotational accuracy of 0.3°. When using fluoroscopy to study kinematics, image distortion and the accuracy of models are important factors, which influence the accuracy of the measurements. MCM-Based RFA has the potential to be an accurate, clinically useful tool for studying kinematics after total joint replacement using standard equipment.
Percutaneous bone cement refixation of aseptically loose hip prostheses: the effect of interface tissue removal on injected cement volumes
Objective To quantify whether injected cement volumes differed between two groups of patients who underwent experimental minimally invasive percutaneous cement injection procedures to stabilize aseptically loose hip prostheses. One patient group was preoperatively treated using gene-directed enzyme prodrug therapy to remove fibrous interface tissue, while the other group received no preoperative treatment. It was hypothesized that cement penetration may have been inhibited by the presence of fibrous interface tissue in periprosthetic lesions. Materials and Methods We analyzed 17 patients (14 female, 3 male, ages 72-91, ASA categories 2-4) who were treated at our institution. Osteolytic lesions and injected cement were manually delineated using 3D CT image segmentation, and the deposition of injected cement was quantified. Results Patients who underwent preoperative gene-directed enzyme therapy to remove fibrous tissue exhibited larger injected cement volumes than those who did not. The observed median increase in injected cement volume was 6.8 ml. Higher cement leakage volumes were also observed for this group. Conclusion We conclude that prior removal of periprosthetic fibrous interface tissue may enable better cement flow and penetration. This might lead to better refixation of aseptically loosened prostheses.
A fluoroscopy-based planning and guidance software tool for minimally invasive hip refixation by cement injection
PurposeIn orthopaedics, minimally invasive injection of bone cement is an established technique. We present HipRFX, a software tool for planning and guiding a cement injection procedure for stabilizing a loosening hip prosthesis. HipRFX works by analysing a pre-operative CT and intraoperative C-arm fluoroscopic images.MethodsHipRFX simulates the intraoperative fluoroscopic views that a surgeon would see on a display panel. Structures are rendered by modelling their X-ray attenuation. These are then compared to actual fluoroscopic images which allow cement volumes to be estimated. Five human cadaver legs were used to validate the software in conjunction with real percutaneous cement injection into artificially created periprothetic lesions.ResultsBased on intraoperatively obtained fluoroscopic images, our software was able to estimate the cement volume that reached the pre-operatively planned targets. The actual median target lesion volume was 3.58 ml (range 3.17–4.64 ml). The median error in computed cement filling, as a percentage of target volume, was 5.3 % (range 2.2–14.8 %). Cement filling was between 17.6 and 55.4 % (median 51.8 %).ConclusionsAs a proof of concept, HipRFX was capable of simulating intraoperative fluoroscopic C-arm images. Furthermore, it provided estimates of the fraction of injected cement deposited at its intended target location, as opposed to cement that leaked away. This level of knowledge is usually unavailable to the surgeon viewing a fluoroscopic image and may aid in evaluating the success of a percutaneous cement injection intervention.
The Effect of Hydroxyapatite on the Micromotion of Total Knee Prostheses. A Prospective, Randomized, Double-Blind Study
A prospective, randomized, double-blind study was performed to evaluate three different means of fixing tibial components during total knee arthroplasty. Eleven components fixed with cement, ten hydroxyapatite-coated components fixed without cement, and ten noncoated components fixed without cement were studied. A posterior cruciate ligament-retaining total condylar implant was used. Micromotion of the components was assessed with roentgen stereophotogrammetric analysis during the two-year follow-up period. There were no significant differences among the patients with regard to age (mean [and standard deviation], 68 ± 11.6 years), body-mass index (mean, 23 ± 2.8 kilograms per square meter), or stage of osteoarthrosis (mean, 4 ± 2.4 according to the classification system of Ahlbäck and 5 ± 0.6 according to that of Larsen et al.). The diagnosis was osteoarthrosis in five knees, and it was rheumatoid arthritis in twenty-six. The clinical scores were similar among the study groups. According to the system of the Knee Society, the mean preoperative functional score was 10 ± 2.9 points and the mean preoperative knee score was 24 ± 3.2 points. At the two-year follow-up evaluation, these scores were 41 ± 8.3 and 79 ± 3.2 points, respectively. A significant difference with regard to micromotion was found between the noncoated components fixed without cement and the hydroxyapatite-coated components fixed without cement as well as between the noncoated components fixed without cement and the components fixed with cement (p < 0.001, analysis of variance). The hydroxyapatite-coated components fixed without cement and the components fixed with cement both had far less micromotion along the longitudinal axis (subsidence) throughout the follow-up period than did the noncoated components fixed without cement. At the two-year follow-up evaluation, the subsidence of the noncoated components was -0.73 ± 0.924 millimeter, the subsidence of the cemented components was -0.05 ± 0.109 millimeter, and the subsidence of the hydroxyapatite-coated components was -0.06 ± 0.169 millimeter. The cemented components as well as the hydroxyapatite-coated components also had less translation along the transverse axis (p < 0.001, analysis of variance) and the sagittal axis (p < 0.001, analysis of variance) compared with the noncoated components. In conclusion, micromotion of hydroxyapatite-coated tibial components fixed without cement was similar to that of tibial components fixed with cement. Therefore, hydroxyapatite, a biological mediator, may be necessary for the adequate fixation of tibial components when cement is not used.
Measuring femoral lesions despite CT metal artefacts: a cadaveric study
Objective Computed tomography is the modality of choice for measuring osteolysis but suffers from metal-induced artefacts obscuring periprosthetic tissues. Previous papers on metal artefact reduction (MAR) show qualitative improvements, but their algorithms have not found acceptance for clinical applications. We investigated to what extent metal artefacts interfere with the segmentation of lesions adjacent to a metal femoral implant and whether metal artefact reduction improves the manual segmentation of such lesions. Materials and methods We manually created 27 periprosthetic lesions in 10 human cadaver femora. We filled the lesions with a fibrotic interface tissue substitute. Each femur was fitted with a polished tapered cobalt-chrome prosthesis and imaged twice—once with the metal, and once with a substitute resin prosthesis inserted. Metal-affected CTs were processed using standard back-projection as well as projection interpolation (PI) MAR. Two experienced users segmented all lesions and compared segmentation accuracy. Results We achieved accurate delineation of periprosthetic lesions in the metal-free images. The presence of a metal implant led us to underestimate lesion volume and introduced geometrical errors in segmentation boundaries. Although PI MAR reduced streak artefacts, it led to greater underestimation of lesion volume and greater geometrical errors than without its application. Conclusion CT metal artefacts impair image segmentation. PI MAR can improve subjective image appearance but causes loss of detail and lower image contrast adjacent to prostheses. Our experiments showed that PI MAR is counterproductive for manual segmentation of periprosthetic lesions and should be used with care.
Co-contraction in RA patients with a mobile bearing total knee prosthesis during a step-up task
It was hypothesized that rheumatoid arthritis (RA) patients with a total knee prosthesis that allows axial rotation of the bearing (MB) will show more co-contraction to stabilize the knee joint during a step-up task than RA patients with a fixed bearing total knee prosthesis (FB) where this rotational freedom is absent while having the same articular geometry. Surface EMG, kinematics and kinetics about the knee were recorded during a step-up task of a MB group ( n  = 5), a FB group ( n  = 4) and a control group ( n  = 8). Surface EMG levels of thigh muscles were calibrated to either knee flexion or extension moments by means of isokinetic contractions on a dynamometer. During the step-up task co-contraction indices were determined from an EMG-force model. Controls showed a higher active ROM during the step-up task than the patient group, 96° versus 88° ( P  = 0.007). In the control group higher average muscle extension, flexion and net moments during single limb support phase were observed than in the patient group. During the 20–60% interval of the single limb support, MB patients showed a significant higher level of flexor activity, resulting in a lower net joint moment, however co-contraction levels were not different. Compared to the control group arthroplasty patients showed a 40% higher level of co-contraction during this interval ( P  = 0.009). Control subjects used higher extension moments, resulting in a higher net joint moment. Visual analysis revealed a timing difference between the MB and FB group. The FB group seems to co-contract approximately 20% later compared to the MB group. RA patients after total knee arthroplasty show a lower net knee joint moment and a higher co-contraction than controls indicating avoidance of net joint load and an active stabilization of the knee joint. MB and FB patients showed no difference in co-contraction levels, although timing in FB is closer to controls than MB subjects. Since visual analysis revealed a timing difference between the MB and FB group, this may express compensation by coordination. Rehabilitation programs for RA patients should include besides muscle strength training, elements of muscle-coordination training.