Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
46
result(s) for
"Van Stenis, M"
Sort by:
Recent Developments on Precise Timing with the PICOSEC Micromegas Detector
2020
The PICOSEC-Micromegas detector was developed for precise timing of the arrival of charged particles with a resolution bellow 30 ps. This contribution, after a brief introduction presents results concerning the PICOSEC-Micromegas response to single photoelectrons, estimation of the photoelectron yield of various photocathode types, as well as its performance to time the arrival of test beam muons. In addition, results based on detailed simulation studies and a stochastic model developed for the understanding of the detector are presented. Finally, results of studies related to the development of large scale PICOSEC-Micromegas detector for practical applications are also presented, in particular, the timing performance of a multi-channel PICOSEC prototype.
Journal Article
Multi-GEM Detectors in High Particle Fluxes
2018
Gaseous Electron Multipliers (GEM) are well known for stable operation at high particle fluxes. We present a study of the intrinsic limits of GEMdetectors when exposed to very high particle fluxes of the order of MHz/mm2. We give an interpretation to the variations of the effective gain, which, as a function of the particle flux, first increases and then decreases. We also discuss the reduction of the ion back-flow with increasing flux. We present measurements and simulations of a triple GEM detector, describing its behaviour in terms of accumulation of positive ions that results in changes of the transfer fields and the amplification fields. The behaviour is expected to be common to all multi-stage amplification devices where the efficiency of transferring the electrons from one stage to the next one is not 100%.
Journal Article
PICOSEC-Micromegas: Robustness measurements and study of different photocathode materials
2019
Detectors with a time resolution of 20-30 ps and a reliable performance in high particles flux environments are necessary for an accurate vertex separation in future HEP experiments. The PICOSEC-Micromegas detector concept is a Micro-Pattern Gaseous Detector (MPGD) based solution addressing this particular challenge. The PICOSEC-Micromegas concept is based on a Micromegas detector coupled to a Cherenkov radiator and a photocathode. In this detector concept, all primary electrons are initiated in the photocathode and the time jitter fluctuations are reduced. Different resistive anode layers have been tested with the goal of preserving a stable detector operation in a high intensity pion beam. One important characteristic of a gaseous detector in a high flux environment is the ion backflow (IBF). That can cause damage to more fragile photocathode materials like CsI. Various types of photocathode materials have been tested in order to find a robust solution against IBF bombardment.
Journal Article
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
2018
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m 2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.
Journal Article
Quality control for the first large areas of triple-GEM chambers for the CMS endcaps
2018
The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m 2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.
Journal Article
Reflectivity Studies and Production of New Flat Mirrors for the Cherenkov Threshold Detectors at CERN
2024
Cherenkov threshold detectors (XCET) are used for identifying particles in the experimental areas at CERN. These detectors observe Cherenkov light emitted by charged particles travelling inside a pressurized gas vessel. A key component of the XCET detector is the 45-degree flat mirror reflecting the Cherenkov light towards the photomultiplier (PMT). A thorough analysis and optimization was conducted on the design and materials of this mirror, along with the surface coatings and coating techniques. A suitable manufacturing process was selected, and the first mirror prototype was produced, installed, and tested in the East Area at CERN. Experimental data obtained during beam tests is presented to assess the efficiency of the new coating and materials used.
Demonstration of Gd-GEM detector design for neutron macromolecular crystallography applications
2023
The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm\\(^2\\) detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. This work presents measurements with the improved version of the NMX detector prototype consisting of a Triple-GEM detector with natural Gd converter and a low material budget readout. The detector was successfully tested at the neutron reactor of the Budapest Neutron Centre (BNC) and at the D16 instrument at the Institut Laue-Langevin (ILL) in Grenoble. The measurements with Cadmium and Gadolinium masks in Budapest demonstrate that the point spread function of the detector lacks long tails that could impede the measurement of diffraction spot intensities. On the D16 instrument at ILL, diffraction spots from Triose phosphate isomerase w/ 2-phosphoglycolate (PGA) inhibitor were measured both in the D16 Helium-3 detector and the Gd-GEM. The comparison between the two detectors show a similar point spread function in both detectors, and the expected efficiency ratio compared to the Helium-3 detector. Both measurements together thus give good indications that the Gd-GEM detector fits the requirements for the NMX instrument at ESS.
Performance of the new RD51 VMM3a/SRS beam telescope---studying MPGDs simultaneously in energy, space and time at high rates
2023
The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the detectors at high rates (up to the MHz regime) with electronics time resolutions of the order of 1 ns and the ability to handle different detector types and sizes, due to a larger dynamic range compared to the previous front-end electronics based on the APV25 ASIC. Having studied and improved the beam telescope's performance over the course of three test beam campaigns, the results are presented in this paper.
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
2024
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.
The novel XYU-GEM to resolve ambiguities
2023
Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was proposed as a three coordinate strip-readout which is combined with a triple GEM detector. The readout complements a common XY readout with an additional projection which is tilted by 45{\\deg}. The overdetermination due to three projections can be used to resovle ambiguities. Following the detector design will be explained, first measurements discussed to understand the response of the detector and a way to change the charge sharing without changing the manufacturing parameters of the readout.