Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
14 result(s) for "Veran, Nicolas"
Sort by:
Fully Automated Macro- and Microfluidic Production of 68GaGa-Citrate on mAIO® and iMiDEVTM Modules
68Ga-radionuclide has gained importance due to its availability via 68Ge/68Ga generator or cyclotron production, therefore increasing the number of 68Ga-based PET radiopharmaceuticals available in clinical practice. [68Ga]Ga-citrate PET has been shown to be prominent for detection of inflammation/infection of the musculoskeletal, gastrointestinal, respiratory, and cardiovascular systems. Automation and comparison between conventional and microfluidic production of [68Ga]Ga-citrate was performed using miniAllInOne® (Trasis) and iMiDEV™ (PMB-Alcen) synthetic modules. Fully automated procedures were elaborated for cGMP production of tracer. In order to facilitate the tracer approval as a radiopharmaceutical for clinical use, a new method for radiochemical identity determination by HPLC analysis to complement standard TLC radiochemical purity measurement was developed. The results showed higher radiochemical yields when using MCX cartridge on the conventional module mAIO®, while a PS-H+ cation exchanger was shown to be preferred for integration into the microfluidic cassette of iMiDEV™ module. In this study, the fully automated radiosynthesis of [68Ga]Ga-citrate using different synthesizers demonstrated reliable and reproducible radiochemical yields. In order to demonstrate the applicability of [68Ga]Ga-citrate, in vitro and in vivo studies were performed showing similar characteristics of the tracer obtained using macro- and microfluidic ways of production.
Preliminary Study of New Gallium-68 Radiolabeled Peptide Targeting NRP-1 to Detect Brain Metastases by Positron Emission Tomography
Due to their very poor prognosis and a fatal outcome, secondary brain tumors are one of the biggest challenges in oncology today. From the point of view of the early diagnosis of these brain micro- and macro-tumors, the sensitivity and specificity of the diagnostic tools constitute an obstacle. Molecular imaging, such as Positron Emission Tomography (PET), is a promising technique but remains limited in the search for cerebral localizations, given the commercially available radiotracers. Indeed, the [18F]FDG PET remains constrained by the physiological fixation of the cerebral cortex, which hinders the visualization of cerebral metastases. Tumor angiogenesis is recognized as a crucial phenomenon in the progression of malignant tumors and is correlated with overexpression of the neuropilin-1 (NRP-1) receptor. Here, we describe the synthesis and the photophysical properties of the new gallium-68 radiolabeled peptide to target NRP-1. The KDKPPR peptide was coupled with gallium-68 anchored into a bifunctional NODAGA chelating agent, as well as Cy5 for fluorescence detection. The Cy5 absorbance spectra did not change, whereas the molar extinction coefficient (ε) decreased drastically. An enhancement of the fluorescence quantum yield (φF) could be observed due to the better water solubility of Cy5. [68Ga]Ga-NODAGA-K(Cy5)DKPPR was radiosynthesized efficiently, presented hydrophilic properties (log D = −1.86), and had high in vitro stability (>120 min). The molecular affinity and the cytotoxicity of this new chelated radiotracer were evaluated in vitro on endothelial cells (HUVEC) and MDA-MB-231 cancer cells (hormone-independent and triple-negative line) and in vivo on a brain model of metastasis in a nude rat using the MDA-MB-231 cell line. No in vitro toxicity has been observed. The in vivo preliminary experiments showed promising results, with a high contrast between the healthy brain and metastatic foci for [68Ga]Ga-NODAGA-K(Cy5)DKPPR.
Fully automated radiolabeling of 68GaGa-EMP100 targeting c-MET for PET-CT clinical imaging
Backgroundc-MET is a transmembrane receptor involved in many biological processes and contributes to cell proliferation and migration during cancer invasion process. Its expression is measured by immunehistochemistry on tissue biopsy in clinic, although this technique has its limitations. PET-CT could allow in vivo mapping of lesions expressing c-MET, providing whole-body detection. A number of radiopharmaceuticals are under development for this purpose but are not yet in routine clinical use. EMP100 is a cyclic oligopeptide bound to a DOTA chelator, with nanomolar affinity for c-MET. The aim of this project was to develop an automated method for radiolabelling the radiopharmaceutical [68Ga]Ga-EMP100.ResultsThe main results showed an optimal pH range between 3.25 and 3.75 for the complexation reaction and a stabilisation of the temperature at 90 °C, resulting in an almost complete incorporation of gallium-68 after 10 min of heating. In these experiments, 90 µg of EMP-100 peptide were initially used and then lower amounts (30, 50, 75 µg) were explored to determine the minimum required for sufficient synthesis yield. Radiolysis impurities were identified by radio-HPLC and ascorbic acid and ethanol were used to improve the purity of the compound. Three batches of [68Ga]Ga-EMP100 were then prepared according to the optimised parameters and all met the established specifications. Finally, the stability of [68Ga]Ga-EMP100 was assessed at room temperature over 3 h with satisfactory results in terms of appearance, pH, radiochemical purity and sterility.ConclusionsFor the automated synthesis of [68Ga]Ga-EMP100, the parameters of pH, temperature, precursor peptide content and the use of adjuvants for impurity management were efficiently optimised, resulting in the production of three compliant and stable batches according to the principles of good manufacturing practice. [68Ga]Ga-EMP100 was successfully synthesised and is now available for clinical development in PET-CT imaging.
PET imaging of 68Ga-NODAGA-RGD, as compared with 18F-fluorodeoxyglucose, in experimental rodent models of engrafted glioblastoma
BackgroundTracers triggering αvβ3 integrins, such as certain RGD-containing peptides, were found promising in previous pilot studies characterizing high-grade gliomas. However, only limited comparisons have been performed with current PET tracers. This study aimed at comparing the biodistribution of 18F-fluorodeoxyglucose (18F-FDG) with that of 68Ga-NODAGA-RGD, an easily synthesized monomeric RGD compound with rapid kinetics, in two different rodent models of engrafted human glioblastoma.MethodsNude rodents bearing human U87-MG glioblastoma tumor xenografts in the flank (34 tumors in mice) or in the brain (5 tumors in rats) were analyzed. Kinetics of 68Ga-NODAGA-RGD and of 18F-FDG were compared with PET imaging in the same animals, along with additional autohistoradiographic analyses and blocking tests for 68Ga-NODAGA-RGD.ResultsBoth tracers showed a primary renal route of clearance, although with faster clearance for 68Ga-NODAGA-RGD resulting in higher activities in the kidneys and bladder. The tumor activity from 68Ga-NODAGA-RGD, likely corresponding to true integrin binding (i.e., suppressed by co-injection of a saturating excess of unlabeled RGD), was found relatively high, but only at the 2nd hour following injection, corresponding on average to 53% of total tumor activity. Tumor uptake of 68Ga-NODAGA-RGD decreased progressively with time, contrary to that of 18F-FDG, although 68Ga-NODAGA-RGD exhibited 3.4 and 3.7-fold higher tumor-to-normal brain ratios on average compared to 18F-FDG in mice and rat models, respectively. Finally, ex-vivo analyses revealed that the tumor areas with high 68Ga-NODAGA-RGD uptake also exhibited the highest rates of cell proliferation and αv integrin expression, irrespective of cell density.Conclusions68Ga-NODAGA-RGD has a high potential for PET imaging of glioblastomas, especially for areas with high integrin expression and cell proliferation, although PET recording needs to be delayed until the 2nd hour following injection in order to provide sufficiently high integrin specificity.
Fully Automated Macro- and Microfluidic Production of 68GaGa-Citrate on mAIO® and iMiDEVTM Modules
68Ga-radionuclide has gained importance due to its availability via 68Ge/68Ga generator or cyclotron production, therefore increasing the number of 68Ga-based PET radiopharmaceuticals available in clinical practice. [68Ga]Ga-citrate PET has been shown to be prominent for detection of inflammation/infection of the musculoskeletal, gastrointestinal, respiratory, and cardiovascular systems. Automation and comparison between conventional and microfluidic production of [68Ga]Ga-citrate was performed using miniAllInOne® (Trasis) and iMiDEV™ (PMB-Alcen) synthetic modules. Fully automated procedures were elaborated for cGMP production of tracer. In order to facilitate the tracer approval as a radiopharmaceutical for clinical use, a new method for radiochemical identity determination by HPLC analysis to complement standard TLC radiochemical purity measurement was developed. The results showed higher radiochemical yields when using MCX cartridge on the conventional module mAIO®, while a PS-H+ cation exchanger was shown to be preferred for integration into the microfluidic cassette of iMiDEV™ module. In this study, the fully automated radiosynthesis of [68Ga]Ga-citrate using different synthesizers demonstrated reliable and reproducible radiochemical yields. In order to demonstrate the applicability of [68Ga]Ga-citrate, in vitro and in vivo studies were performed showing similar characteristics of the tracer obtained using macro- and microfluidic ways of production.68Ga-radionuclide has gained importance due to its availability via 68Ge/68Ga generator or cyclotron production, therefore increasing the number of 68Ga-based PET radiopharmaceuticals available in clinical practice. [68Ga]Ga-citrate PET has been shown to be prominent for detection of inflammation/infection of the musculoskeletal, gastrointestinal, respiratory, and cardiovascular systems. Automation and comparison between conventional and microfluidic production of [68Ga]Ga-citrate was performed using miniAllInOne® (Trasis) and iMiDEV™ (PMB-Alcen) synthetic modules. Fully automated procedures were elaborated for cGMP production of tracer. In order to facilitate the tracer approval as a radiopharmaceutical for clinical use, a new method for radiochemical identity determination by HPLC analysis to complement standard TLC radiochemical purity measurement was developed. The results showed higher radiochemical yields when using MCX cartridge on the conventional module mAIO®, while a PS-H+ cation exchanger was shown to be preferred for integration into the microfluidic cassette of iMiDEV™ module. In this study, the fully automated radiosynthesis of [68Ga]Ga-citrate using different synthesizers demonstrated reliable and reproducible radiochemical yields. In order to demonstrate the applicability of [68Ga]Ga-citrate, in vitro and in vivo studies were performed showing similar characteristics of the tracer obtained using macro- and microfluidic ways of production.
Stress-first protocol for myocardial perfusion SPECT imaging with semiconductor cameras: high diagnostic performances with significant reduction in patient radiation doses
Purpose Effective doses of 14 mSv or higher are currently being attained in patients having stress and rest myocardial perfusion imaging (MPI) single photon emission computed tomography (SPECT) performed on the same day with conventional protocols. This study aimed to assess the actual reduction in effective doses as well as diagnostic performances for MPI routinely planned with: (1) high-sensitivity cadmium zinc telluride (CZT) cameras, (2) very low injected activities and (3) a stress-first protocol where the normality of stress images may lead to avoiding rest imaging. Methods During a 1-year period, 2,845 patients had MPI on a CZT camera, a single-day stress-first protocol and low injected activities (120 MBq of 99m Tc-sestamibi at stress for 75 kg body weight and threefold higher at rest). The ability to detect > 50 % coronary stenosis was assessed in a subgroup of 149 patients who also had coronary angiography, while the normalcy rate was assessed in a subgroup of 128 patients with a low pretest likelihood of coronary artery disease (<10 %). Results Overall, 33 % of patients had abnormal MPI of which 34 % were women and 34 % were obese. The mean effective doses and the percentage of exams involving only stress images were: (1) 3.53 ± 2.10 mSv and 37 % in the overall population, (2) 4.83 ± 1.56 mSv and 5 % in the subgroup with angiography and (3) 1.96 ± 1.52 mSv and 71 % in the low-probability subgroup. Sensitivity and global accuracy for identifying the 106 patients with coronary stenosis were 88 and 80 %, respectively, while the normalcy rate was 97 %. Conclusion When planned with a low-dose stress-first protocol on a CZT camera, MPI provides high diagnostic performances and a dramatic reduction in patient radiation doses. This reduction is even greater in low-risk subgroups with high rates of normal stress images, thus allowing the mean radiation dose to be balanced against cardiac risk in targeted populations.
Fully Automated Macro- and Microfluidic Production of 68 GaGa-Citrate on mAIO ® and iMiDEV TM Modules
Ga-radionuclide has gained importance due to its availability via Ge/ Ga generator or cyclotron production, therefore increasing the number of Ga-based PET radiopharmaceuticals available in clinical practice. [ Ga]Ga-citrate PET has been shown to be prominent for detection of inflammation/infection of the musculoskeletal, gastrointestinal, respiratory, and cardiovascular systems. Automation and comparison between conventional and microfluidic production of [ Ga]Ga-citrate was performed using miniAllInOne (Trasis) and iMiDEV™ (PMB-Alcen) synthetic modules. Fully automated procedures were elaborated for cGMP production of tracer. In order to facilitate the tracer approval as a radiopharmaceutical for clinical use, a new method for radiochemical identity determination by HPLC analysis to complement standard TLC radiochemical purity measurement was developed. The results showed higher radiochemical yields when using MCX cartridge on the conventional module mAIO , while a PS-H+ cation exchanger was shown to be preferred for integration into the microfluidic cassette of iMiDEV™ module. In this study, the fully automated radiosynthesis of [ Ga]Ga-citrate using different synthesizers demonstrated reliable and reproducible radiochemical yields. In order to demonstrate the applicability of [ Ga]Ga-citrate, in vitro and in vivo studies were performed showing similar characteristics of the tracer obtained using macro- and microfluidic ways of production.
Routine evaluation of left ventricular function using CZT-SPECT, with low injected activities and limited recording times
Gamma-cameras, with Cadmium-Zinc-Telluride (CZT) detectors, allow to perform myocardial perfusion imaging (MPI) with limited injected activities and recorded times. This study aimed at determining whether the routine assessment of left ventricular (LV) function with such limited counts protocols compares well with reference values from cardiac MRI. The study included patients who have undergone cardiac MRI and an MPI routinely planned on a CZT camera with a low-dose protocol (120 MBq of Sestamibi for stress and 360 MBq at rest for 75 kg body weight), while targeting the recording of only 500 myocardial kcounts in order to limit the recording times (<10 minutes for stress, <4 minutes for rest). SPECT images were reconstructed with a method maintaining rather high spatial (8 mm) and temporal (16 frames/cycle) resolutions. Seventy-six patients were included, and mean effective dose was 3.5 ± 1.7 mSv for the total MPI protocol. Correlations between CZT-SPECT and MRI were good to excellent for ejection fraction (r2 = 0.77), end-diastolic (r2 = 0.88) and end-systolic (r2 = 0.93) volumes, and the analysis of segmental contractility correlated well between the two techniques (kappa score = 0.72 ± 0.02). LV function, assessed on a CZT camera with low injected activities and limited recording times, correlates well with the reference assessment from cardiac MRI.