Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
2 result(s) for "Vignando, M."
Sort by:
Optimizing the ITER NBI ion source by dedicated RF driver test stand
The experimental fusion reactor ITER will feature two (or three) heating neutral beam injectors (NBI) capable of delivering 33(or 50) MW of power into the plasma. A NBI consists of a plasma source for production of negative ions (extracted negative ion current up to 329 A/m 2 in H and 285 A/m 2 in D) then accelerated up to 1 MeV for one hour. The negative ion beam is neutralized, and the residual ions are electrostatically removed before injection. The beamline was designed for a beam divergence between 3 and 7 mrad. The ion source in ITER NBIs relies on RF-driven, Inductively-Coupled Plasmas (ICP), based on the prototypes developed at IPP Garching; RF-driven negative-ion beam sources have never been employed in fusion devices up to now. The recent results of SPIDER, the full size ITER NBI ion source operating at NBTF in Consorzio RFX, Padova, measure a beamlet divergence minimum of 12mrad and highlighted beam spatial non-uniformity. SPIDER results confirmed the experimental divergence found in smaller prototype sources, which is larger compared to filament-arc ion sources. Although prototype experiments have shown that the extracted current requirement can be achieved with minor design improvements, the beamlet divergence is expected to marginally achieve the design value of 7 mrad, which in multi-grid long accelerators results in unexpected heat loads over the accelerator grids. A contributor to the beam divergence is the energy/temperature of the extracted negative ions, so it is believed that plasma differences between the two source types play a role. Research is focused on the plasma parameters in the ion source. One RF driver, identical to the ones used in SPIDER, installed in a relatively small-scale experimental set-up, inherently more flexible than large devices, is starting operations devoted to the investigation of the properties of RF-generated plasmas, so as to contribute to the assessment of negative ion precursors, and of their relationship with the plasma parameters, particularly when enhancing plasma confinement. The scientific questions, that have arisen from the preliminary results of SPIDER, guided the design of the test stand, which are described in this contribution, together with the diagnostic systems and related simulation tools. The test stand, which shares with the larger experiment all the geometrical features and constraints, will allow technological developments and optimized engineering solutions related to the ICP design for the ITER NBIs.
Lessons learned after three years of SPIDER operation and the first MITICA integrated tests
ITER envisages the use of two heating neutral beam injectors plus an optional one as part of the auxiliary heating and current drive system. The 16.5 MW expected neutral beam power per injector is several notches higher than worldwide existing facilities. A Neutral Beam Test Facility (NBTF) was established at Consorzio RFX, exploiting the synergy of two test beds, SPIDER and MITICA. SPIDER is dedicated to developing and characterizing large efficient negative ion sources at relevant parameters in ITER-like conditions: source and accelerator located in the same vacuum where the beam propagates, immunity to electromagnetic interferences of multiple radio-frequency (RF) antennas, avoidance of RF-induced discharges on the outside of the source. Three years of experiments on SPIDER have addressed to the necessary design modifications to enable full performances. The source is presently under a long shut-down phase to incorporate learnings from the experimental campaign. Parallelly, developments on MITICA, the full-scale prototype of the ITER NBI featuring a 1 MV accelerator and ion neutralization, are underway including manufacturing of in-vessel components, while power supplies and auxiliary plants are already under final testing and commissioning. Integration, commissioning and tests of the 1MV power supplies are essential for this first-of-kind system, unparalleled both in research and industry field. The integrated test to confirm 1MV output by combining invertor systems, DC generators and transmission lines extracted errors/accidents in some components. To realize a concrete system for ITER, solutions for the repair and the improvement of the system were developed. Hence, NBTF is emerging as a necessary facility, due to the large gap with existing injectors, effectively dedicated to identify issues and find solutions to enable successful ITER NBI operations in a time bound fashion.