Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
38
result(s) for
"Viguier, Éric"
Sort by:
Prevalence of canine hip dysplasia in 10 breeds in France, a retrospective study of the 1997-2017 radiographic screening period
by
Baldinger, Arnaud
,
Barthélemy, Anthony
,
Genevois, Jean-Pierre
in
Animals
,
Biology and Life Sciences
,
Biomedical materials
2020
Canine hip dysplasia (HD) is a complex developmental disease of the coxo-femoral joint and is one of the most common orthopedic conditions in dogs. Due to the genetic contribution, most of the programs fighting against HD recommend selective breeding that excludes affected dogs. Using the best-scoring dogs for breeding may reduce the prevalence of HD. In France, the phenotypic screening of coxo-femoral joint conformation remains a strategy for breeders to establish selection decisions. The HD prevalence was evaluated in 10 breeds, based on the assessment of 27,710 dogs, during the 1997-2017 screening period, which was divided into 3 homogeneous cohorts for analysis. The global HD prevalence varied widely among breeds from 5% (Siberian Husky) to 51.9% (Cane Corso). It decreased over time in 6 breeds, among which 4 (Cane Corso, Gordon Setter, Rottweiler and White Swiss Shepherd) showed a significant decrease. A statistically significant increase in HD prevalence was noted for the Siberian Husky. Although the efficacy of phenotype-based breeding programs remains controversial, our results are in accordance with several recent studies showing that long-term selection policies are valuable, as they may help decreasing the HD prevalence in some breeds. The complementary use of more recent tools such as estimated breeding values and genomics would probably help breeders achieve more substantive results.
Journal Article
Risk factors and clinical relevance of positive urine cultures in cats with subcutaneous ureteral bypass
2021
Background
The objective of the study was to report the incidence and risk factors associated with positive urine bacterial cultures as well as long-term outcome in cats with subcutaneous ureteral bypass (SUB) devices.
Results
Medical records of cats that underwent SUB device placement were retrospectively reviewed. Signalment of the cat, laterality of the ureteral obstruction, surgery, anesthesia and hospitalization duration, bacterial culture results and follow-up data were retrieved.
Thirty-two cats met the inclusion criteria. Four cats (12.5%) had a positive intraoperative culture, with two of them being treated successfully. Ten cats out of 28 (35.7%) were documented with a positive urine culture during follow-up period, with a median time between discharge and identification of the first positive urine culture of 159 days (range 8–703 days). Bacteriuria resolved in 60% of cats (6/10).
Escherichia coli
was the most common organism, isolated in 4 out of 10 postoperative urine cultures. Overall, subclinical bacteriura was documented for 6 of 32 (18.8%) cats and 5 of 32 (15.6%) cats displayed clinicals signs suggestive of persistent UTI. One cat had subclinical bacteriuria. Three cats died during the follow-up period.
There was a significant difference between negative and positive urine bacterial culture groups in median hospitalization duration (5 days versus 6 days,
P
= 0.022) and in median body condition score (5/9 versus 4/9,
P
= 0.03). Cats with a longer hospital stay and with a lower body condition score were more likely to have a positive urine culture during follow-up period.
Conclusions
SUB device placement surgery is associated with complications such as chronic bacteriuria. Bacteriuria in our study resolved with appropriate antibiotic treatment in more than half of cats. Risk factors identified for positive urine culture were a longer hospitalization duration and a decreased body condition score.
Journal Article
Cellulose Nanofiber-Reinforced Chitosan Hydrogel Composites for Intervertebral Disc Tissue Repair
by
Sudre, Guillaume
,
Peniche-Covas, Carlos
,
Horbelt, Niels
in
Animal models
,
Biocompatibility
,
Biodegradation
2019
The development of non-cellularized composites of chitosan (CHI) hydrogels, filled with cellulose nanofibers (CNFs) of the type nanofibrillated cellulose, was proposed for the repair and regeneration of the intervertebral disc (IVD) annulus fibrosus (AF) tissue. With the achievement of CNF-filled CHI hydrogels, biomaterial-based implants were designed to restore damaged/degenerated discs. The structural, mechanical and biological properties of the developed hydrogel composites were investigated. The neutralization of weakly acidic aqueous CNF/CHI viscous suspensions in NaOH yielded composites of physical hydrogels in which the cellulose nanofibers reinforced the CHI matrix, as investigated by means of microtensile testing under controlled humidity. We assessed the suitability of the achieved biomaterials for intervertebral disc tissue engineering in ex vivo experiments using spine pig models. Cellulose nanofiber-filled chitosan hydrogels can be used as implants in AF tissue defects to restore IVD biomechanics and constitute contention patches against disc nucleus protrusion while serving as support for IVD regeneration.
Journal Article
Repair of Tendon Disruption Using a Novel Synthetic Fiber Implant in Dogs and Cats: The Surgical Procedure and Three Case Reports
2020
Surgical management of tendon rupture is challenging. One concern is to provide adequate tensile strength to prevent distraction during weight-bearing and gap formation following repair, associated with an increased risk of repair failure. Additional challenges may arise from the nature or the chronicity of the lesion. In the event of avulsion, when the tendon is torn off at the bone insertion, its reinsertion on the bone is generally difficult and may even be impossible in the presence of an avulsion fracture, especially when the bone fragment is too small or fragmented. Repair management is also complicated in chronic cases, as degeneration of the tendon may lead to excessive scar tissue formation, tendon retraction, and muscle atrophy, resulting in a large gap and inadequate tissue for reconstruction. The authors describe the surgical procedure for implanting a novel implant, illustrated by three characteristic clinical cases: (1) an acute Achilles tendon avulsion; (2) a chronic patellar tendon rupture; and (3) a chronic avulsion fracture of the triceps tendon. In these three cases, complete recovery of the function was observed at the last clinical evaluation (6 or 8 months), and no complication was noted. A splinted dressing (6 to 8 weeks) was used successfully in two cases. A resin cast (8 weeks) was preferred in case 1, a very active dog. In conclusion, this novel implant represents a simple procedure for the effective repair of chronic tendon rupture, as well as an effective tendon reinsertion on the bone and adequate support for bone tendon healing in the treatment of tendon avulsion, even in cases of fragmented bone fracture. The thinness of the implant facilitates its insertion into the native tendon, while the bone-screw-implant interface provides immediate and lasting mechanical support. This may facilitate the healing process and potentially shorten the period of immobilization.
Journal Article
Safe corridor for the implantation of thoracolumbar pedicle screws in growing pigs: A morphometric study
by
Carozzo, Claude
,
Pillard, Paul
,
Odent, Thierry
in
Animal models
,
Animals
,
Biology and Life Sciences
2017
The pig spine is widely used as a large animal model for preclinical research in human medicine to test new spinal implants and surgical procedures. Among them, pedicle screw is one of the most common method of fixation of those implants. However, the pedicle of the porcine vertebra is not as well defined and not as large as the pedicle of the human vertebra. Therefore, the position of the screw should be adapted to the pig and not merely transposed based on the literature on humans. The purpose of this study is to determine the characteristics of the optimum implantation corridors for pedicle screws in the thoracolumbar spine of piglets of different ages using computed tomography (CT) and to determine the size and length of these corridors in pigs of different ages. CT scans from five groups of age: 6, 10, 14, 18, and 26 weeks were reviewed. For each thoracolumbar vertebrae, the pedicle width, pedicle axis length, and the pedicle angle was measured for the left and right pedicle. A total of 326 thoracic vertebrae and 126 lumbar vertebrae were included in the study. Pedicles are statistically larger but not longer for the lumbar vertebrae. An important variation of the pedicle angle is observed along the spine. In all pigs, an abrupt modification of the pedicle angle between T10 and T11 was observed, which corresponds to the level of the anticlinal vertebra which is the vertebra for which the spinous process is nearly perpendicular to the vertebral body. In conclusion, this study provides a quantitative database of pedicle screw implantation corridors in pigs of different ages. When using pedicle screws in experimental studies in pigs, these results should be considered for selecting the most suitable implants for the study but also to ensure a correct and safer screw position. Improving study procedures may limit postoperative complications and pain, thereby limiting the use of live animals.
Journal Article
Long-Term Safety and Efficacy of Single or Repeated Intra-Articular Injection of Allogeneic Neonatal Mesenchymal Stromal Cells for Managing Pain and Lameness in Moderate to Severe Canine Osteoarthritis Without Anti-inflammatory Pharmacological Support: Pilot Clinical Study
2019
To explore the long-term safety and efficacy of canine allogeneic mesenchymal stromal cells (MSC) administered intra-articularly as single or repeated injections in appendicular joints of dogs affected by moderate to severe refractory osteoarthritis.
22 pet dogs were recruited into a non-randomized, open and monocentric study initially administering one cellular injection. A second injection was offered after 6 months to owners if the first injection did not produce expected results.
Anti-inflammatory treatment (if prescribed) was discontinued at last one week before the onset of treatment. Each injection consisted of at least 10 million viable neonatal allogeneic mesenchymal stromal cells obtained from fetal adnexa. Medical data was collected from veterinary clinical evaluations of joints up to 6 months post-injection and owner's assessment of their dog's mobility and well-being followed for a further 2 years when possible.
Mild, immediate self-limiting inflammatory joint reactions were observed in 5/22 joints after the first injection, and in almost all dogs having a subsequent injection. No other MSC-related adverse medical events were reported, neither during the 6 months follow up visits, nor during the long-term (2-years) safety follow up. Veterinary clinical evaluation showed a significant and durable clinical improvement (up to 6 months) following MSC administration. Eight dogs (11 joints) were re-injected 6 months apart, sustaining clinical benefits up to 1 year. Owner's global satisfaction reached 75% at 2 years post-treatment
Our data suggest that a single or repeated intra-articular administration of neonatal MSC in dogs with moderate to severe OA is a safe procedure and confer clinical benefits over a 24-month period. When humoral response against MSC is investigated by flow cytometry, a positive mild and transient signal was detected in only one dog from the studied cohort, this dog having had a positive clinical outcome.
Journal Article
Pedicle Screw Fixation Study in Immature Porcine Spines to Improve Pullout Resistance during Animal Testing
by
Rossi, Jean-Marie
,
Le Cann, Sophie
,
Miladi, Lotfi
in
Animal biology
,
Animal experimentation
,
Animal research
2015
The porcine model is frequently used during development and validation of new spinal devices, because of its likeness to the human spine. These spinal devices are frequently composed of pedicle screws with a reputation for stable fixation but which can suffer pullouts during preclinical implantation on young animals, leading to high morbidity. With a view to identifying the best choices to optimize pedicle screw fixation in the porcine model, this study evaluates ex vivo the impact of weight (age) of the animal, the level of the vertebrae (lumbar or thoracic) and the type of screw anchorage (mono- or bi-cortical) on pedicle screw pullouts. Among the 80 pig vertebrae (90- and 140-day-old) tested in this study, the average screw pullout forces ranged between 419.9N and 1341.2N. In addition, statistical differences were found between test groups, pointing out the influence of the three parameters stated above. We found that the the more caudally the screws are positioned (lumbar level), the greater their pullout resistance is, moreover, screw stability increases with the age, and finally, the screws implanted with a mono-cortical anchorage sustained lower pullout forces than those implanted with a bi-cortical anchorage. We conclude that the best anchorage can be obtained with older animals, using a lumbar fixation and long screws traversing the vertebra and inducing bi-cortical anchorage. In very young animals, pedicle screw fixations need to be bi-cortical and more numerous to prevent pullout.
Journal Article
Intra-Articular Surgical Reconstruction of a Canine Cranial Cruciate Ligament Using an Ultra-High-Molecular-Weight Polyethylene Ligament: Case Report with Six-Month Clinical Outcome
by
Buttin, Philippe
,
Martenne-Duplan, Antonin
,
Crumière, Antonin
in
Allografts
,
Anterior cruciate ligament
,
Antiarthritic agents
2024
The intra-articular reconstruction of the cranial cruciate ligament (CrCL) by an organic graft or a synthetic implant allows the restoration of physiological stifle stability. This treatment is still marginal in routine practice. A Rottweiler presented an acute complete CrCL rupture treated using an ultra-high-molecular-weight polyethylene (UHMWPE) implant. The latter was positioned under arthroscopic guidance and fixed with interference screws through femoral and tibial bone tunnels. The dog was weight-bearing just after surgery and resumed normal standing posture and gait after one month, with mild signs of pain upon stifle manipulation. At three months postoperatively, minimal muscle atrophy and minimal craniocaudal translation were noted on the operated hindlimb, with no effects on the clinical outcome. The stifle was painless. At six months postoperatively, standing posture and gait were normal, muscle atrophy had decreased, the stifle was painless, and the craniocaudal translation was stable. On radiographs, congruent articular surfaces were observed without worsening of osteoarthrosis over the follow-up, as well as stable moderate joint effusion. Replacement of a ruptured CrCL with a UHMWPE ligament yielded good functional clinical outcome at six months postoperatively. This technique could be considered an alternative for the treatment of CrCL rupture in large dogs, but it needs confirmation from a prospective study with more dogs.
Journal Article
Evaluation of the Effect of a Single Intra-articular Injection of Allogeneic Neonatal Mesenchymal Stromal Cells Compared to Oral Non-Steroidal Anti-inflammatory Treatment on the Postoperative Musculoskeletal Status and Gait of Dogs over a 6-Month Period after Tibial Plateau Leveling Osteotomy: A Pilot Study
2017
Compare the clinical and pressure walkway gait evolution of dogs after a tibial plateau leveling osteotomy (TPLO) for a cranial cruciate ligament rupture (CrCLR) and treatment with either a 1-month course of non-steroidal anti-inflammatory drugs (NSAIDs) or a single postoperative intra-articular (IA) injection of allogeneic neonatal mesenchymal stromal cells (MSCs).
Prospective, double-blinded, randomized, controlled, monocentric clinical study.
Sixteen client-owned dogs.
Dogs with unilateral CrCLR confirmed by arthroscopy were included. Allogeneic neonatal canine MSCs were obtained from fetal adnexa retrieved after C-section performed on healthy pregnant bitches. The dogs were randomly allocated to either the \"MSCs group,\" receiving an IA injection of MSCs after TPLO, followed by placebo for 1 month, or the \"NSAIDs group,\" receiving IA equivalent volume of MSCs vehicle after TPLO, followed by oral NSAID for 1 month. One of the three blinded evaluators assessed the dogs in each group before and after surgery (1, 3, and 6 months). Clinical score and gait and bone healing process were assessed. The data were statistically compared between the two groups for pre- and postoperative evaluations.
Fourteen dogs (nine in the MSCs group, five in the NSAIDs group) completed the present study. No significant difference was observed between the groups preoperatively. No local or systemic adverse effect was observed after MSCs injection at any time point considered. At 1 month after surgery, bone healing scores were significantly higher in the MSCs group. At 1, 3, and 6 months after surgery, no significant difference was observed between the two groups for clinical scores and gait evaluation.
A single IA injection of allogeneic neonatal MSCs could be a safe and valuable postoperative alternative to NSAIDs for dogs requiring TPLO surgery, particularly for dogs intolerant to this class of drugs.
Journal Article
Radiographic assessment of the femorotibial joint of the CCLT rabbit experimental model of osteoarthritis
by
Roger, Thierry W
,
Duclos, Marie-Eve
,
Boulocher, Caroline B
in
Animals
,
Anterior Cruciate Ligament - surgery
,
Arthrography - methods
2010
Background
The purposes of the study were to determine the relevance and validity of in vivo non-invasive radiographic assessment of the CCLT (Cranial Cruciate Ligament Transection) rabbit model of osteoarthritis (OA) and to estimate the pertinence, reliability and reproducibility of a radiographic OA (ROA) grading scale and associated radiographic atlas.
Methods
In vivo non-invasive extended non weight-bearing radiography of the rabbit femorotibial joint was standardized. Two hundred and fifty radiographs from control and CCLT rabbits up to five months after surgery were reviewed by three readers. They subsequently constructed an original semi-quantitative grading scale as well as an illustrative atlas of individual ROA feature for the medial compartment. To measure agreements, five readers independently scored the same radiographic sample using this atlas and three of them performed a second reading. To evaluate the pertinence of the ROA grading scale, ROA results were compared with gross examination in forty operated and ten control rabbits.
Results
Radiographic osteophytes of medial femoral condyles and medial tibial condyles were scored on a four point scale and dichotomously for osteophytes of medial fabella. Medial joint space width was scored as normal, reduced or absent. Each ROA features was well correlated with gross examination (p < 0.001). ICCs of each ROA features demonstrated excellent agreement between readers and within reading. Global ROA score gave the highest ICCs value for between (ICC 0.93; CI 0.90-0.96) and within (ICC ranged from 0.94 to 0.96) observer agreements. Among all individual ROA features, medial joint space width scoring gave the highest overall reliability and reproducibility and was correlated with both meniscal and cartilage macroscopic lesions (r
s
= 0.68 and r
s
= 0.58, p < 0.001 respectively). Radiographic osteophytes of the medial femoral condyle gave the lowest agreements while being well correlated with the macroscopic osteophytes (r
s
= 0.64, p < 0.001).
Conclusion
Non-invasive in vivo radiography of the rabbit femorotibial joint is feasible, relevant and allows a reproducible grading of experimentally induced OA lesion. The radiographic grading scale and atlas presented could be used as a template for in vivo non invasive grading of ROA in preclinical studies and could allow future comparisons between studies.
Journal Article