Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
55 result(s) for "Vuletić, Marko"
Sort by:
Comparison of Hydrophilic Properties of Titanium and Zirconia Dental Implants’ Surfaces
One of the key factors influencing osseointegration is the hydrophilicity of the surface of dental implants; high hydrophilicity is more advantageous than low hydrophilicity. This study aimed to compare the hydrophilic properties of titanium and zirconia implants from different manufacturers. An in vitro analysis was conducted on 15 implants—13 titanium and 2 zirconia—each featuring distinct compositions and surface treatments. Their hydrophilicity was assessed using the contact angle method, where a drop of saline solution was pipetted onto the apical part of the implant. For each implant, 30 contact angle measurements were taken at three different surface wetting time intervals. The contact angle is defined as the internal angle between the tangent to the surface of the liquid and the surface at the point of tangency; a smaller angle means a higher hydrophilicity. The results show that titanium implants from BTI UniCa, Nobel TiUltra, and Straumann Roxolid SLActive—which are classified as premium implants—exhibited the highest hydrophilicity. In contrast, zirconia implants demonstrated significantly lower hydrophilicity. Within this group, the Nobel Pearl implant exhibited smaller contact angles than the Bredent WhiteSKY implant. Our findings confirm that high-quality titanium implants show superior hydrophilicity, potentially improving clinical outcomes by accelerating healing and facilitating immediate loading protocols, but this could only be proven with an in vivo animal study. Conversely, the relatively lower hydrophilicity of zirconia implants highlights the need for continued advancements in zirconia composition and surface modification to optimize their osseointegration potential.
Dimensional Stability of Polymer and Titanium Implant Scan Bodies After Repeated Steam Sterilization: A High-Resolution 3D Metrological In Vitro Study
The increasing adoption of digital workflows in implant dentistry relies heavily on the accuracy of implant scan bodies (ISBs), which may be affected by repeated sterilization. This in vitro study evaluated the effect of 50 steam sterilization cycles on the dimensional stability of polymer and titanium ISBs. A total of 100 test specimens (n = 50 per material) were scanned before (T0) and after sterilization (T50) using a high-resolution intraoral scanner, generating 900 STL datasets for metrological analysis. Surface deviation, linear displacement, and angular deviation were assessed using validated industrial and dental software, with statistical evaluation performed through paired tests and linear mixed-effects models. Both materials exhibited statistically significant dimensional changes after sterilization (p < 0.001). Titanium scan bodies demonstrated greater linear deformation (69.76 μm) compared to polymer ones (49.50 μm), while maintaining superior angular stability (0.21° vs. −1.69° mean angular change in the polymer group). A significant interaction between material type and sterilization was observed. Despite high baseline precision, repeated autoclaving induced clinically relevant deviations in both materials. These findings indicate that cumulative sterilization cycles adversely affect ISB accuracy and highlight the importance of adhering to manufacturer recommendations to ensure optimal prosthetic outcomes.
Accuracy of Static Computer-Aided Implant Surgery: A Clinical Comparison of Tooth-, Bone-, and Mucosa-Supported Surgical Guides
The accuracy of static computer-aided implant surgery (s-CAIS) is fundamental for predictable clinical outcomes. The objective of this study was to evaluate the influence of different guide-support modalities on the linear and angular accuracy of implant placement. In this retrospective clinical investigation conducted at a single specialty hospital, a total of 180 implants were analyzed, divided into three equal groups (n = 60) based on the guide support type: tooth-supported, bone-supported, and mucosa-supported. Accuracy was assessed by superimposing preoperative virtual plans with postoperative cone-beam computed tomography (CBCT) scans, measuring linear deviations at the neck and apex of the implant, as well as angular discrepancies. The type of guide support was found to be a significant factor associated with surgical accuracy (p < 0.001). Tooth-supported guides demonstrated the highest level of accuracy, with a mean angular deviation of 1.81° ± 0.45° and linear deviations at the neck and apex of 0.59 ± 0.18 mm and 0.73 ± 0.19 mm, respectively. These were followed by bone-supported guides (2.14° ± 0.48°; 1.04 ± 0.26 mm; 1.61 ± 0.31 mm), while mucosa-supported guides exhibited the greatest deviations (2.95° ± 0.60°; 1.47 ± 0.29 mm; 1.87 ± 0.37 mm). Significant intergroup differences and large effect sizes were observed, particularly regarding angular and horizontal discrepancies. These findings demonstrate a distinct gradient of accuracy based on guide support, establishing tooth-supported guides as the most accurate, followed by bone-supported and, lastly, mucosa-supported guides. While all modalities are clinically applicable, the use of mucosa-supported guides necessitates increased safety margins to account for the increased risk of linear and angular discrepancies inherent to mucosal tissue displacement.
Recreational Exercise and Inflammatory Patterns in Hashimoto’s Thyroiditis: Observations from a Cross-Sectional Study
In this cross-sectional observational study, we investigated whether recreational exercise (RE) influences systemic inflammation in Hashimoto’s thyroiditis (HT) across different disease severity groups. We analyzed 403 participants from the Croatian Biobank of Patients with HT (CRO-HT), including 173 controls and 230 HT patients (euthyroid, levothyroxine [LT4]-treated, and hypothyroid). Serum levels of 92 inflammatory proteins were measured using the Olink® Target 96 Inflammation panel, and exercise status was assessed via structured questionnaires. Linear regression revealed distinct protein associations depending on thyroid status. In controls, RE was associated with reduced MMP-10 and FGF-5, reflecting cardiovascular and muscle benefits. In euthyroid patients, RE was associated with decreased CXCL9 and TRAIL, implicating reduced type 1 inflammation and vascular risk. LT4-treated patients showed increases in IL-15RA and IL-24 with RE, suggesting improved muscle metabolism and anti-inflammatory effects. In hypothyroid patients, RE was associated with reduced CCL20 and increased HGF, while changes in TRANCE and TWEAK indicated mixed effects on bone and immune regulation. Notably, RE was associated with reduced CXCL9 and CCL20, two proteins previously linked to HT risk. Overall, RE is associated with distinct changes in inflammatory profiles across HT disease severity groups, with the most favourable responses observed in LT4-treated patients, suggesting synergy with hormone therapy.
Safety and Feasibility of Dental Evaluation in Patients Undergoing Heart Valve Replacement Surgery: Retrospective Analysis
Background/Objectives: Although there is a general consensus that patients should have dental evaluation before heart valve surgery, data on the extent and complications of this evaluation are scarce. The objective was to analyze safety and feasibility of dental evaluation in patients undergoing heart valve surgery. Methods: A retrospective chart review of patients referred for dental evaluation prior to heart valve surgery in 2021–2023 was conducted. Demographic, medical, and dental data were recorded. The number and type of dental procedures and their complications were recorded, along with the number of appointments and the time required to achieve dental clearance for heart valve surgery. Results: One hundred and fifty-three patients were referred in the observed period. The predominant procedure was tooth extraction, accounting for 76 (49.7%) cases. Complications were recorded in 3 (1.9%) patients, with delayed bleeding being the most prevalent issue, occurring in 2 (1.3%) patients. The median time required to obtain dental clearance for cardiosurgical procedure was 1 day, with 124 (81%) patients obtaining clearance in a single appointment. No dental emergencies were observed during hospital admission for the cardiosurgical procedure. Conclusions: Our results suggest that dental evaluation before heart valve surgery can be conducted in a reasonable amount of time with a low complication rate and without the need to delay cardiosurgical procedures.
Accuracy of Fully Guided Implant Placement Using Bone-Supported Stackable Surgical Guides in Completely Edentulous Patients—A Retrospective Study
Background/Objectives: Precise implant positioning is critical for successful prosthetic rehabilitation, particularly in completely edentulous patients where anatomical landmarks are lost. The aim of this study was to assess the accuracy of implant placement in the edentulous maxilla and mandible using computer-assisted planning and a bone-supported stackable surgical guide protocol. Methods: This retrospective clinical study included 15 completely edentulous patients who received a total of 60 implants. A dual-scan protocol was utilized for planning. The surgical protocol involved a base guide fixed to the bone with pins, serving as a rigid foundation for stackable components used for osteotomy and implant insertion. Postoperative CBCT scans were superimposed onto the preoperative plan to calculate angular deviations, 3D linear deviations at the implant neck and apex, and depth deviations. Results: The analysis demonstrated high accuracy with a mean angular deviation of 1.25° ± 0.80°. The mean 3D linear deviation was 0.96 ± 0.57 mm at the implant neck and 1.07 ± 0.56 mm at the apex. Depth deviation showed a mean discrepancy of 0.37 ± 0.58 mm. All measured parameters were statistically significantly lower (p < 0.05) than the pre-established clinical safety thresholds. Conclusions: Within the limitations of this study, the bone-supported stackable surgical guide protocol proved to be a highly accurate method for full-arch rehabilitation. By eliminating mucosal resilience and ensuring rigid fixation, this approach enables predictable implant placement and facilitates the passive fit of screw-retained bar-supported prostheses, representing a reliable alternative to dynamic navigation in daily clinical practice.
Evaluation of Different Procedures for Titanium Dental Implant Surface Decontamination—In Vitro Study
Polymicrobial biofilm removal and decontamination of the implant surface is the most important goal in the treatment of periimplantitis. The aim of this study is to evaluate the efficacy of four different decontamination methods for removing Acinetobacter baumannii and Staphylococcus aureus biofilms in vitro. Seventy-five dental implants were contaminated with a bacterial suspension and randomly divided into five groups (n = 15): the negative control group, which received no treatment; the positive control group, treated with 0.2% chlorhexidine; group 1, treated with a chitosan brush (Labrida BioCleanTM, Labrida AS, Oslo, Norway); group 2, treated with a chitosan brush and 0.2% chlorhexidine; and group 3, treated with a device based on the electrolytic cleaning method (GalvoSurge, GalvoSurge Dental AG, Widnau, Switzerland). The colony-forming unit (CFU) count was used to assess the number of viable bacteria in each sample, and statistical analyses were performed. When compared to the negative control group, all the decontamination methods reduced the CFU count. The electrolytic cleaning method decontaminated the implant surface more effectively than the other three procedures, while the chitosan brush was the least effective. Further research in more realistic settings is required to assess the efficacy of the decontamination procedures described in this study.
A Novel Technique for Disinfection Treatment of Contaminated Dental Implant Surface Using 0.1% Riboflavin and 445 nm Diode Laser—An In Vitro Study
Background: Antimicrobial photodynamic therapy (PDT) has been introduced as a potential option for peri-implantitis treatment. The aim of this study is to evaluate the antimicrobial effect of a novel technique involving a combination of 445 nm diode laser light with 0.1% riboflavin solution (used as a photosensitizing dye) as applied on a bacterial–fungal biofilm formed on implants and to compare the performance of this technique with that of the commonly used combination of 660 nm diode laser with 0.1% methylene blue dye. Methods: An in vitro study was conducted on 80 titanium dental implants contaminated with Staphylococcus aureus (SA) and Candida albicans (CA) species. The implants were randomly divided into four groups: negative control (NC), without surface treatment; positive control (PC), treated with a 0.2% chlorhexidine (CHX)-based solution; PDT1, 660 nm (EasyTip 320 µm, 200 mW, Q power = 100 mW, 124.34 W/cm2, 1240 J/cm2) with a 0.1% methylene blue dye; and PDT2, 445 nm (EasyTip 320 µm, 200 mW, Q power = 100 mW, 100 Hz, 124.34 W/cm2, 1.24 J/cm2) with a 0.1% riboflavin dye. Results: The PDT1 and PDT2 groups showed greater reduction of SA and CA in comparison to the NC group and no significant differences in comparison to the PC group. No statistically significant differences between the PDT1 and PDT2 groups were observed. Conclusions: A novel antimicrobial treatment involving a combination of 445 nm diode laser light with riboflavin solution showed efficiency in reducing SA and CA biofilm formation on dental implant surfaces comparable to those of the more commonly used PDT treatment consisting of 660 nm diode laser light with methylene blue dye or 0.2% CHX treatment.
Implant Prosthodontic Rehabilitation after Surgical Treatment for an Oropharyngeal Malignant Tumour Using Tantalum Dental Implants
Oropharyngeal cancer (OPC) represents a significant portion of head and neck cancers. In most cases, it is localised in the soft palate, lingual and palatine tonsils, base of the tongue, and the surrounding tissues. Alcohol and tobacco exposure are well-known evidence-based risk factors for developing OPC; however, over the last decade, there has been a rapid increase in OPC linked to human papillomavirus (HPV). Dental implant therapy faces many challenges related to immediate and long-term success, and patients who are rehabilitated with implant prosthodontic therapy often have numerous comorbidities. Tantalum is a rare transitional metal element which has high corrosion resistance and is extremely inert. Porous tantalum trabecular metal (PTTM) has high volumetric porosity, a low modulus of elasticity, and very high friction. PTTM implant surface enhancement allows “osseoincorporation,” which means the neovascularisation and formation of new bone directly onto the implant. A 65-year-old patient presented to the Department of Oral Surgery of Clinical Hospital Centre Zagreb after resection of the mandible due to OPC had oral rehabilitation. Three Zimmer Biomet Trabecular Metal™ implants (4.1×10 mm) were inserted in the area of lower left first incisor, lower left second premolar, and lower right second premolar, and after four months, a new upper partial denture and the bar-retained mandibular overdenture were made. Implant prosthodontic rehabilitation of head and neck cancer patients is usually challenging in terms of achieving an improvement in its main aim, quality of life; however, today it is a safe and reliable therapy. Although radiation therapy may negatively affect the patient’s oral condition and influence the short- and long-term success of the implant, the presented case report showed that the excellent properties of PTTM-enhanced dental implants may give great basis for future comparative researches of using these implants in the treatment of oncologic patients.
Evaluation of the Photoactivation Effect of 3% Hydrogen Peroxide in the Disinfection of Dental Implants: In Vitro Study
Photoactivation of 3% hydrogen peroxide with a 445 nm diode laser represents a relatively new, insufficiently researched antimicrobial method in the treatment of peri-implantitis. The purpose of this work is to evaluate the effect of photoactivation of 3% hydrogen peroxide with a 445 nm diode laser, and to compare the obtained results with 0.2% chlorhexidine treatment and 3% hydrogen peroxide treatment without photoactivation, in vitro, on the surface of dental implants contaminated with S. aureus and C. albicans biofilms. Previously, 80 infected titanium implants with S. aureus and C. albicans cultures were divided into four groups: G1-negative control (no treatment), G2-positive control (0.2% chlorhexidine), G3 (3% hydrogen peroxide), and G4 (photoactivated 3% hydrogen peroxide). The number of viable microbes in each sample was determined by the colony forming unit (CFU) count. The results were statistically processed and analyzed, showing a statistically significant difference across all groups compared to the negative control (G1), and the absence of a statistically significant difference between groups G1–G3. The new antimicrobial treatment, according to the results, could be worthy of further analysis and research.