Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Series TitleSeries Title
-
Reading LevelReading Level
-
YearFrom:-To:
-
More FiltersMore FiltersContent TypeItem TypeIs Full-Text AvailableSubjectCountry Of PublicationPublisherSourceTarget AudienceDonorLanguagePlace of PublicationContributorsLocation
Done
Filters
Reset
884
result(s) for
"Weber, Eric"
Sort by:
The wizard's war
by
Luper, Eric, author
,
Weber, Lisa K., illustrator
,
Luper, Eric. Key hunters ;
in
Books and reading Juvenile fiction.
,
Libraries Juvenile fiction.
,
Magic Juvenile fiction.
2017
This time Cleo, Evan, and Ms. Crowley (who, it turns out, is the missing Ms. Hilliard's sister) find themselves in a confusing fantasy book, caught up in a war with wizards, elves, trolls, and the mighty Golden Dragon-- and while they manage to find their missing librarian, their quest does not end there.
National population mapping from sparse survey data
by
Weber, Eric M.
,
Jochem, Warren C.
,
Seaman, Vincent
in
Bayesian analysis
,
Bayesian statistics
,
Census
2020
Population estimates are critical for government services, development projects, and public health campaigns. Such data are typically obtained through a national population and housing census. However, population estimates can quickly become inaccurate in localized areas, particularly where migration or displacement has occurred. Some conflict-affected and resource-poor countries have not conducted a census in over 10 y. We developed a hierarchical Bayesian model to estimate population numbers in small areas based on enumeration data from sample areas and nationwide information about administrative boundaries, building locations, settlement types, and other factors related to population density. We demonstrated this model by estimating population sizes in every 10- m grid cell in Nigeria with national coverage. These gridded population estimates and areal population totals derived from them are accompanied by estimates of uncertainty based on Bayesian posterior probabilities. The model had an overall error rate of 67 people per hectare (mean of absolute residuals) or 43% (using scaled residuals) for predictions in out-of-sample survey areas (approximately 3 ha each), with increased precision expected for aggregated population totals in larger areas. This statistical approach represents a significant step toward estimating populations at high resolution with national coverage in the absence of a complete and recent census, while also providing reliable estimates of uncertainty to support informed decision making.
Journal Article
Battle of the bots
by
Luper, Eric, author
,
Weber, Lisa K., illustrator
,
Luper, Eric. Key hunters ;
in
Books and reading Juvenile fiction.
,
Libraries Juvenile fiction.
,
Magic Juvenile fiction.
2018
Despite the evil Locke, Cleo and Evan manage to get Gabriel back to his world, but it is a world that is controlled by a computer network which is connected by a device called a Neuro-Zip implanted in the skull of every human being in the world--every human except for Cleo and Evan, so it is up to them to bring down the Network, and return control to the human population.
Evaluating the construct validity and test-retest reliability of the Orthotic Patient-Reported Outcomes–Mobility (OPRO-M) short forms in lower limb orthosis users
2025
Lower limb orthoses (LLOs) are often prescribed to facilitate mobility in individuals with functional impairments. The Orthotic Patient-Reported Outcomes – Mobility (OPRO-M) is a self-report instrument developed recently to measure LLO users’ perceived mobility with an orthosis. An observational, prospective, psychometric validation study was conducted to evaluate the construct validity and test-retest reliability of the OPRO-M 12- and 20-item short forms. LLO users were recruited from orthotic clinics across the United States. Participants were administered four self-report instruments (OPRO-M, Orthotic and Prosthetic Users Survey – Lower Extremity Functional Status, Lower Extremity Functional Scale, and Patient-Reported Outcomes Measurement Information System – Physical Function) and three performance-based instruments (10-meter Walk Test, Timed Up and Go Test, and Two-Minute Walk Test) during an in-person assessment. Self-report instruments were re-administered via an online survey sent to participants 7 days later. Convergent validity was assessed by comparing OPRO-M scores to those from co-administered self-report and performance-based instruments. Known groups validity was evaluated by comparing scores from patients grouped by clinician-assigned mobility level. Test-retest reliability was assessed by comparing scores from the in-person and follow-up assessments. Standard error of measurement (SEM) and smallest detectable change (SDC) were derived from test-retest reliability coefficients. A total of 104 LLO users (51% male, mean age = 53 years) completed both assessments. OPRO-M short form scores correlated strongly with those from self-report (ρ = 0.84–0.91) and performance-based (|ρ| = 0.73–0.83) instruments. OPRO-M short form scores also effectively differentiated all mobility groups except household and limited community ambulators. The OPRO-M short forms showed excellent test-retest reliability (ICC = 0.93–0.94) and low measurement error (SEM = 2.4–2.6, SDC = 5.5–6.0). These results provide sound evidence of the OPRO-M short forms’ validity and reliability when used to measure mobility in LLO users. These instruments are promising, population-specific alternatives to generic surveys with psychometric performance comparable to or better than established self-report instruments.
Journal Article
Development and initial validation of the Orthotic Patient-Reported Outcomes—Mobility (OPRO-M): An item bank for evaluating mobility of people who use lower-limb orthoses
by
Stevens, Phillip M.
,
Weber, Eric L.
,
Amtmann, Dagmar
in
Ankle
,
Biology and Life Sciences
,
Bone diseases
2023
Lower limb orthoses (LLOs) are externally-applied leg braces that are designed to improve or maintain mobility in people with a variety of health conditions that affect lower limb function. Clinicians and researchers are therefore often motivated to measure LLO users’ mobility to select or assess the effectiveness of these devices. Patient-reported outcome measures (PROMs) can provide insights into important aspects of a LLO user’s mobility for these purposes. However, few PROMs are available to measure mobility of LLO users. Those few that exist have issues that may limit their clinical or scientific utility. The objective of this study was to create a population-specific item bank for measuring mobility of LLO users. Previously-developed candidate items were administered in a cross-sectional study to a large national sample of LLO users. Responses from study participants (n = 1036) were calibrated to a graded response statistical model using Item Response Theory methods. A set of 39 items was found to be unidimensional, locally independent, and function without bias due to characteristics unrelated to mobility. The set of final calibrated items, termed the Orthotic Patient-Reported Outcomes—Mobility (OPRO-M) item bank, was evaluated for initial evidence of convergent, divergent, and known groups construct validity. OPRO-M was strongly correlated with existing PROMs designed to measure aspects of physical function. Conversely, OPRO-M was weakly correlated with PROMs that measured unrelated constructs, like sleep disturbance and depression. OPRO-M also showed an ability to differentiate groups with expected mobility differences. Two fixed-length short forms were created from the OPRO-M item bank. Items on the short forms were selected based on statistical and clinical criteria. Collectively, results from this study indicate that OPRO-M can effectively measure mobility of LLO users, and OPRO-M short forms can now be recommended for use in routine clinical practice and research studies.
Journal Article
Correction: Development and initial validation of the Orthotic Patient-Reported Outcomes—Mobility (OPRO-M): An item bank for evaluating mobility of people who use lower-limb orthoses
[This corrects the article DOI: 10.1371/journal.pone.0293848.].
Journal Article
Parseval frames from compressions of Cuntz algebras
by
Dutkay, Dorin Ervin
,
Weber, Eric S.
,
Christoffersen, Nicholas
in
Algebra
,
Decomposition
,
Fractals
2023
A row co-isometry is a family
(
V
i
)
i
=
0
N
-
1
of operators on a Hilbert space, subject to the relation
∑
i
=
0
N
-
1
V
i
V
i
∗
=
I
.
As shown in Bratteli et al. (J Oper Theory, 43, 97–143, 2000), row co-isometries appear as compressions of representations of Cuntz algebras. In this paper we will present some general constructions of Parseval frames for Hilbert spaces, obtained by iterating the operators
V
i
on a finite set of vectors. The constructions are based on random walks on finite graphs. As applications of our constructions we obtain Parseval Fourier bases on self-affine measures and Parseval Walsh bases on the interval.
Journal Article
Evaluating the construct validity and test-retest reliability of the Orthotic Patient-Reported Outcomes-Mobility
2025
Lower limb orthoses (LLOs) are often prescribed to facilitate mobility in individuals with functional impairments. The Orthotic Patient-Reported Outcomes - Mobility (OPRO-M) is a self-report instrument developed recently to measure LLO users' perceived mobility with an orthosis. An observational, prospective, psychometric validation study was conducted to evaluate the construct validity and test-retest reliability of the OPRO-M 12- and 20-item short forms. LLO users were recruited from orthotic clinics across the United States. Participants were administered four self-report instruments (OPRO-M, Orthotic and Prosthetic Users Survey - Lower Extremity Functional Status, Lower Extremity Functional Scale, and Patient-Reported Outcomes Measurement Information System - Physical Function) and three performance-based instruments (10-meter Walk Test, Timed Up and Go Test, and Two-Minute Walk Test) during an in-person assessment. Self-report instruments were re-administered via an online survey sent to participants 7 days later. Convergent validity was assessed by comparing OPRO-M scores to those from co-administered self-report and performance-based instruments. Known groups validity was evaluated by comparing scores from patients grouped by clinician-assigned mobility level. Test-retest reliability was assessed by comparing scores from the in-person and follow-up assessments. Standard error of measurement (SEM) and smallest detectable change (SDC) were derived from test-retest reliability coefficients. A total of 104 LLO users (51% male, mean age = 53 years) completed both assessments. OPRO-M short form scores correlated strongly with those from self-report ([rho] = 0.84-0.91) and performance-based (|[rho]| = 0.73-0.83) instruments. OPRO-M short form scores also effectively differentiated all mobility groups except household and limited community ambulators. The OPRO-M short forms showed excellent test-retest reliability (ICC = 0.93-0.94) and low measurement error (SEM = 2.4-2.6, SDC = 5.5-6.0). These results provide sound evidence of the OPRO-M short forms' validity and reliability when used to measure mobility in LLO users. These instruments are promising, population-specific alternatives to generic surveys with psychometric performance comparable to or better than established self-report instruments.
Journal Article