Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
24
result(s) for
"Wefstaedt, Patrick"
Sort by:
Impact of body weight and sex in selected dog breeds on the canine adrenal gland dimensions measured by computed tomographic imaging
by
Wefstaedt, Patrick
,
Büttelmann, Gerrit
,
Harder, Lisa Katharina
in
Abdomen
,
Adrenal gland
,
Adrenal glands
2023
Background
The present study aimed to investigate possible influences of body weight and sex on adrenal gland size in endocrinologically healthy dogs. Possible factors influencing the adrenal size are discussed in relation to a universal upper reference value from the literature of 7.4 mm as the thickness in the caudal pole of the adrenal gland. The adrenal size was measured by computed tomography (CT) from 66 normal dogs of six different breeds (Labrador Retriever (n = 16), German Shepherd (n = 10), Boxer (n = 8), Beagle (n = 14), Dachshund (n = 6) and Jack Russell Terrier (n = 12); male n = 38 (thereof neutered n = 23), female n = 28 (thereof neutered n = 17)) based on volume quantification and linear measurements using the data processing software Amira. For interbreed comparability, a ratio consisting of the third root of adrenal volume to aortic diameter (Ratio volume-aorta, RVA) was introduced. Additionally, breed-related attenuation values in contrast-enhanced CT data sets were measured.
Results
The measured volumes ranged from 0.34 to 1.93 cm
3
for the right and from 0.39 to 2.23 cm
3
for the left adrenal gland. The present study was able to demonstrate a body weight effect on the adrenal volume as well as on length and height. In terms of adrenal size, no significant differences between male and female, nor between intact and neutered dogs were obtained due to the RVA. In addition, for the weight classes, a breed independent threshold for dogs less (left 1.4; right gland 1.5) or more than 20 kg body weight (left 1.1; right gland 1.2) based on RVA was defined. Breed-related significant differences with respect to attenuation were determined only for the left adrenal gland, with lower attenuation values in large dog breeds.
Conclusion
The present study points out the importance of weight-related data when assessing CT data of the canine adrenal gland regarding volume, size and attenuation. The use of a universal reference value for the assessment of adrenal size appears unsuitable considering weight-related volume and linear measurements. Sex seems not to affect adrenal gland size.
Journal Article
Fore-Aft Ground Force Adaptations to Induced Forelimb Lameness in Walking and Trotting Dogs
by
Wefstaedt, Patrick
,
Nolte, Ingo
,
Abdelhadi, Jalal
in
Acceleration
,
Adaptation
,
Adaptation, Physiological
2012
Animals alter their locomotor mechanics to adapt to a loss of limb function. To better understand their compensatory mechanisms, this study evaluated the changes in the fore-aft ground forces to forelimb lameness and tested the hypothesis that dogs unload the affected limb by producing a nose-up pitching moment via the exertion of a net-propulsive force when the lame limb is on the ground. Seven healthy Beagles walked and trotted at steady speed on an instrumented treadmill while horizontal force data were collected before and after a moderate lameness was induced. Peak, mean and summed braking and propulsive forces as well as the duration each force was exerted and the time to reach maximum force were evaluated for both the sound and the lame condition. Compared with the sound condition, a net-propulsive force was produced by the lame diagonal limbs due to a reduced braking force in the affected forelimb and an increased propulsive force in the contralateral hindlimb when the dogs walked and trotted. To regain pitch stability and ensure steady speed for a given locomotor cycle, the dogs produced a net-braking force when the sound diagonal limbs were on the ground by exerting greater braking forces in both limbs during walking and additionally reducing the propulsive force in the hindlimb during trotting. Consistent with the proposed mechanism, dogs maximize their double support phases when walking. Likely associated with the fore-aft force adaptations to lameness are changes in muscle recruitment that potentially result in short- and long-term effects on the limb and trunk muscles.
Journal Article
Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings
by
Wefstaedt, Patrick
,
Henjes, Christiane R
,
Nolte, Ingo
in
abnormal development
,
angiography
,
Animals
2011
Background
Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT) was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography.
Results
Electrocardiography (ECG)-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol.
Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats.
Conclusions
Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional information can be of help with regard to improved diagnoses of thoracic anomalies and the planning of surgical interventions.
Journal Article
Validation of canine prostate volumetric measurements in computed tomography determined by the slice addition technique using the Amira program
by
Kuhnt, Nora Sophie Marita
,
Lüpke, Matthias
,
Wefstaedt, Patrick
in
Accessory gland
,
Accuracy
,
Age composition
2019
Background
Prostatic diseases are common and mostly associated with enlargement of the accessory gland. Thus, determining the prostate size has become a main criterion for evaluating prostate health status. Computed tomography (CT) is recommended as a beneficial tool for evaluating prostate size, morphology and surrounding tissues. The purpose of this study was to establish an accurate procedure for volume estimation and afterwards evaluate the prostate volume in CT. Data of 95 dogs were analysed (58 male intact, 37 male neutered) using the slice addition technique with the Amira program. Accuracy of volumetric measurements by CT was validated by comparing them with those of phantoms of known volume. Patients were grouped according to age (< 4 yrs., 4–8 yrs., > 8 yrs) and prostate morphology in CT (H = homogeneous, I = inhomogeneous, C = cystic). The length of the sixth lumbar vertebra was measured to relate prostate volume to body size. This ratio was generated to compare prostate volume between the groups, irrespective of body size (ratio volume = Rv).
Results
A high correlation between the CT-derived and phantom volume was found. Overall, the mean prostate volume was 58.6 cm
3
. The mean ratio volume was 1.3 in intact male dogs, this being significantly higher than in neutered dogs (0.7). The lowest ratio volume values were found in group H for intact (Rv = 0.9) and neutered dogs (Rv = 0.6), followed by group I (intact: Rv = 1.1; neutered: Rv = 0.7) and C (intact: Rv = 1.4; neutered: Rv = 0.8). The length of the sixth lumbar vertebra was well correlated with the prostate volume (intact: r = 0.63,
p
< 0.001; neutered: r = 0.48,
p
= 0.003), while age exhibited a correlation only in intact dogs (r = 0.52,
p
< 0.001).
Conclusion
The present study is pioneering in applying a slice addition technique to volumetric measurements of the prostate gland in CT, resulting in a highly precise method. Volumetric measurements of the canine prostate gland in CT images provide information about the prostate structure, castration status, age and body size of the patients. Therefore, prostate volume is a relevant parameter for evaluating prostate health status.
Journal Article
Evaluation of canine prostate volume in calculated tomographic images - comparison of two assessment methods
2019
Background
Since most prostatic diseases are associated with the organ’s enlargement, evaluation of prostatic size is a main criterion in the diagnosis of prostatic state of health. While enlargement is a non-uniform process, volumetric measurements are believed to be advantageous to any single dimensional parameter for the diagnosis of prostatomegaly. In a previous study, volume was analysed with a slice addition technique (SAT), which was validated as highly accurate. Irrespective of high accuracy, SAT represents a complex and time-consuming procedure, which limits its clinical use. Thus, demand exists for more practical volume assessment methods. In this study, the prostatic volume of 95 canine patients (58 intact males, 37 neutered males) were analysed retrospectively by using the ellipsoid formula (Formula) and an imaging “wrap” function tool (Wrap) to help assess accuracy and applicability. Accuracy was checked against phantom measurements and results were compared to SAT measurements of the same patient pool obtained from a previously published paper. Patients were grouped according to prostatic structure (H = homogeneous, I = inhomogeneous, C = cystic) and volume using the SAT (volume group = vg: 1, 2 and 3).
Results
High correlation between the Formula or Wrap volume and the phantom volume was found, the values being higher for the Formula. Mean Formula volumes (vg 1: 2.2 cm
3
, vg 2: 14.5 cm
3
, vg 3: 109.4 cm
3
, respectively) were significantly underestimated, while mean Wrap volumes (vg 1: 3.8 cm
3
, vg 2: 19.5 cm
3
, vg 3: 159.2 cm
3
) were statistically equivalent to SAT measurements (vg 1: 3.1 cm
3
, vg 2: 18.6 cm
3
, vg 3: 157.2 cm
3
, respectively). Differences between Formula and SAT volumes ranged from 22.4–31.1%, while differences between Wrap and SAT volumes were highest in small prostates (vg 1: 22.1%) and fell with increasing prostatic size (vg 3: 1.3%).
Conclusion
The Wrap function is highly accurate, less time-consuming and complex compared to SAT and could serve as beneficial tool for measuring prostatic volume in clinical routine after further validation in future studies. The Formula method cannot be recommended as an alternative for volumetric measurements of the prostate gland due to its underestimation of volumes compared to SAT results.
Journal Article
Measurement of single kidney glomerular filtration rate in dogs using dynamic contrast-enhanced magnetic resonance imaging and the Rutland-Patlak plot technique
2018
Background
Nephropathies are among the most common diseases in dogs. Regular examination of the kidney function plays an important role for an adequate treatment scheme. The determination of the glomerular filtration rate (GFR) is seen as the gold standard in assessing the kidney status. Most of the tests have the disadvantage that only the complete glomerular filtration rate of both kidneys can be assessed and not the single kidney glomerular filtration rate. Imaging examination techniques like dynamic contrast-enhanced magnetic resonance imaging have the potential to evaluate the single kidney GFR. There are studies in human medicine describing the determination of the single kidney GFR using this technique. To our knowledge there are no such studies for dogs.
Results
An exponential fit was found to describe the functional interrelation between signal intensity and contrast medium concentrations. The changes of contrast medium concentrations during the contrast medium bolus propagation were calculated. The extreme values of contrast medium concentrations in the kidneys were reached at nearly the same time in every individual dog (1st maximum aorta 8.5 s, 1st maximum in both kidneys after about 14.5 s; maximum concentration values varied between 17 and 125 µmol/mL in the aorta and between 4 and 15 µmol/mL in the kidneys). The glomerular filtration rate was calculated from the concentration changes of the contrast medium using a modified Rutland-Patlak plot technique. The GFR was 12.7 ± 2.9 mL/min m
2
BS for the left kidney and 12.0 ± 2.2 mL/min/m
2
BS for the right kidney. The mean values of the coefficient of determination of the regression lines were averagely 0.91 ± 0.08.
Conclusions
The propagation of contrast medium bolus could be depicted well. The contrast medium proceeded in a similar manner for every individual dog. Additionally, the evaluation of the single kidney function of the individual dogs is possible with this method. A standardized examination procedure would be recommended in order to minimize influencing parameters.
Journal Article
Development of a zoomorphic test specimen for constancy testing on digital X-ray systems in veterinary radiology
2019
Background
Technical failures and incorrect usage of digital X-ray systems may lead to a decreasing image quality, artefacts and a higher dose exposure of staff and patients. Although there are no regulations regarding constancy testing in veterinary radiology all operators are required to avoid unnecessary exposure. The aim of this study was to develop a reasonably inexpensive zoomorphic 3D-printed test specimen for constancy testing that allows the detection of changing image quality by visual analysis.
Primarily, a calibration curve of the attenuation factor of the 3D-printing material (ZP150) was determined. MATLAB converted every pixel value of a thorax X-ray image of a Beagle dog into an equivalent thickness of printing material. The thickness distribution was printed using a 3D-printer. This printed test specimen was additionally provided with five thin aluminium discs to simulate lung nodules.
To evaluate the usability for constancy testing 12 X-ray images of the test specimen were made. Two images (reference and control) were taken with the minimum dose in order to obtain images suitable for diagnosis purposes. Eight images were taken with a dose differing 30–140% from the reference dose by varying current–time product (mAs) or tube voltage (kVp). Two images were taken with the same parameters as the reference image but edited with different image processing. Six veterinarians (general practitioners) evaluated ten chosen structures in the X-ray images in a Visual Grading Analysis and scored the image quality of these structures for every image in comparison to the reference image. A Visual Grading Analysis Score was calculated and statistically analysed.
Results
A higher current–time product led to a negligibly better evaluation of the X-ray image. The lower the current–time product the worse the X-ray images were scored. Likewise, both increasing and decreasing of the tube voltage led to lower scores.
Conclusions
A zoomorphic test specimen can be used for constancy testing of digital X-ray systems in veterinary medicine. Especially a lower dose can be recognised due to deviation in the image quality when compared to the reference image. The 3D-printed test specimen is less expensive than test equipment used in human medicine.
Journal Article
The cementless Bicontact® stem in a prospective dual-energy X-ray absorptiometry study
by
Stukenborg-Colsman, Christina M.
,
Wefstaedt, Patrick
,
Lerch, Matthias
in
Absorptiometry, Photon - methods
,
Adult
,
Aged
2012
Purpose
The cementless Bicontact® total hip arthroplasty (THA) system (AESCULAP AG, Tuttlingen, Germany) was introduced in 1986/1987 and has been in successful clinical use in an unaltered form up to today. Although good long-term results with the Bicontact® stem have been published, it is questionable whether the implant provides the criteria for a state-of-the-art stem regarding proximal bone stock preservation. The purpose of the study was to monitor the periprosthetic bone mineral density (BMD) in a prospective two-year follow-up dual-energy X-ray absorptiometry (DEXA) study.
Methods
After power analysis, a consecutive series of 25 patients with unilateral Bicontact® stem implantation was examined clinically and underwent DEXA examinations. Scans of seven regions of interest were taken preoperatively and at one week, six months, and one and two years.
Results
One patient required stem revision due to a deep infection. The Harris Hip Score increased significantly by 44 points. The most significant bone loss was observed in the calcar region (R7) in the first six months (−19.2 %). It recovered in the following 18 months to −8.5 %. The BMD in the greater trochanter dropped significantly after six months and remained stable at this level. BMD exceeded baseline values in distal regions and even more in the lesser trochanter region after two years.
Conclusions
We conclude that the Bicontact® stem provides adequate proximal bone stock preservation. We observed some signs of stress shielding at the tip of the stem, which is inevitable to some degree in THA with cementless straight stems. However, in this prospective DEXA investigation, we showed that proximal off-loading does not occur after THA with the Bicontact® system. Thus, we believe that this stem is still a state-of-the-art implant.
Journal Article
Numerical investigations on the strain-adaptive bone remodelling in the periprosthetic femur: Influence of the boundary conditions
by
Behrens, Bernd-Arno
,
Wefstaedt, Patrick
,
Nolte, Ingo
in
Adaptation, Physiological - physiology
,
Biomaterials
,
Biomedical Engineering and Bioengineering
2009
Background
There are several numerical investigations on bone remodelling after total hip arthroplasty (THA) on the basis of the finite element analysis (FEA). For such computations certain boundary conditions have to be defined. The authors chose a maximum of three static load situations, usually taken from the gait cycle because this is the most frequent dynamic activity of a patient after THA.
Materials and methods
The numerical study presented here investigates whether it is useful to consider only one static load situation of the gait cycle in the FE calculation of the bone remodelling. For this purpose, 5 different loading cases were examined in order to determine their influence on the change in the physiological load distribution within the femur and on the resulting strain-adaptive bone remodelling. First, four different static loading cases at 25%, 45%, 65% and 85% of the gait cycle, respectively, and then the whole gait cycle in a loading regime were examined in order to regard all the different loadings of the cycle in the simulation.
Results
The computed evolution of the apparent bone density (ABD) and the calculated mass losses in the periprosthetic femur show that the simulation results are highly dependent on the chosen boundary conditions.
Conclusion
These numerical investigations prove that a static load situation is insufficient for representing the whole gait cycle. This causes severe deviations in the FE calculation of the bone remodelling. However, accompanying clinical examinations are necessary to calibrate the bone adaptation law and thus to validate the FE calculations.
Journal Article
Longitudinal MRI contrast enhanced monitoring of early tumour development with manganese chloride (MnCl2) and superparamagnetic iron oxide nanoparticles (SPIOs) in a CT1258 based in vivo model of prostate cancer
by
Meier, Martin
,
Glage, Silke
,
Sterenczak, Katharina A
in
Animal sciences
,
Animals
,
Biomedical and Life Sciences
2012
Background
Cell lines represent a key tool in cancer research allowing the generation of neoplasias which resemble initial tumours in
in-vivo
animal models. The characterisation of early tumour development is of major interest in order to evaluate the efficacy of therapeutic agents. Magnetic resonance imaging (MRI) based
in-vivo
characterisation allows visualisation and characterisation of tumour development in early stages prior to manual palpation. Contrast agents for MRI such as superparamagnetic iron oxide nanoparticles (SPIOs) and manganese chloride (MnCl
2
) represent powerful tools for the
in-vivo
characterisation of early stage tumours. In this experimental study, we labelled prostate cancer cells with MnCl
2
or SPIOs
in vitro
and used 1 T MRI for tracing labelled cells
in-vitro
and 7 T MRI for tracking in an
in-vivo
animal model.
Methods
Labelling of prostate cancer cells CT1258 was established
in-vitro
with MnCl
2
and SPIOs.
In-vitro
detection of labelled cells in an agar phantom was carried out through 1 T MRI while
in-vivo
detection was performed using 7 T MRI after subcutaneous (s.c.) injection of labelled cells into NOD-Scid mice (n = 20). The animals were scanned in regular intervals until euthanization. The respective tumour volumes were analysed and corresponding tumour masses were subjected to histologic examination.
Results
MnCl
2
in-vitro
labelling resulted in no significant metabolic effects on proliferation and cell vitality.
In-vitro
detection-limit accounted 10
5
cells for MnCl
2
as well as for SPIOs labelling.
In-vivo
7 T MRI scans allowed detection of 10
3
and 10
4
cells.
In-vivo
MnCl
2
labelled cells were detectable from days 4–16 while SPIO labelling allowed detection until 4 days after s.c. injection. MnCl
2
labelled cells were highly tumourigenic in NOD-Scid mice and the tumour volume development was characterised in a time dependent manner. The amount of injected cells correlated with tumour size development and disease progression. Histological analysis of the induced tumour masses demonstrated characteristic morphologies of prostate adenocarcinoma.
Conclusions
To the best of our knowledge, this is the first study reporting direct
in-vitro
MnCl
2
labelling and 7 T based
in-vivo
MRI tracing of cancer cells in a model of prostate cancer. MnCl
2
labelling was found to be suitable for
in-vivo
tracing allowing long detection periods. The labelled cells kept their highly tumourigenic potential
in-vivo.
Tumour volume development was visualised prior to manual palpation allowing tumour characterisation in early stages of the disease.
Journal Article