Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
21 result(s) for "Weisse, Bernhard"
Sort by:
Modular stimuli-responsive hydrogel sealants for early gastrointestinal leak detection and containment
Millions of patients every year undergo gastrointestinal surgery. While often lifesaving, sutured and stapled reconnections leak in around 10% of cases. Currently, surgeons rely on the monitoring of surrogate markers and clinical symptoms, which often lack sensitivity and specificity, hence only offering late-stage detection of fully developed leaks. Here, we present a holistic solution in the form of a modular, intelligent suture support sealant patch capable of containing and detecting leaks early. The pH and/or enzyme-responsive triggerable sensing elements can be read out by point-of-need ultrasound imaging. We demonstrate reliable detection of the breaching of sutures, in as little as 3 hours in intestinal leak scenarios and 15 minutes in gastric leak conditions. This technology paves the way for next-generation suture support materials that seal and offer disambiguation in cases of anastomotic leaks based on point-of-need monitoring, without reliance on complex electronics or bulky (bio)electronic implantables. Digestive surgical leaks manifesting days after a successful surgery can lead to severe complications and affect healthcare worldwide. Here, the authors address the problem holistically with a hydrogel patch capable of sealing tissues, while detecting imminent leaks via a smartphone-operated ultrasound probe.
European Society of Biomechanics S.M. Perren Award 2022: Standardized tibio-femoral implant loads and kinematics
Knowledge of both tibio-femoral kinematics and kinetics is necessary for fully understanding knee joint biomechanics, guiding implant design and testing, and driving and validating computational models. In 2017, the CAMS-Knee datasets were presented, containing synchronized in vivo implant kinematics measured using a moving fluoroscope and tibio-femoral contact loads measured using instrumented implants from six subjects. However, to date, no representative summary of kinematics and kinetics obtained from measurements at the joint level of the same cohort of subjects exists. In this study, we present the CAMS-Knee standardized subject “Stan”, whose reference data include tibio-femoral kinematics and loading scenarios from all six subjects for level and downhill walking, stair descent, squat and sit-to-stand-to-sit. Using the peak-preserving averaging method by Bergmann and co-workers, we derived scenarios for generally high (CAMS-HIGH100), peak, and extreme loading. The CAMS-HIGH100 axial forces reached peaks between 3022 and 3856 N (3.08–3.93 body weight) for the five investigated activities. Anterior-posterior forces were about a factor of ten lower. The axial moment around the tibia was highest for level walking and squatting with peaks of 9.4 Nm and 10.5 Nm acting externally. Internal tibial rotations of up to 8.4° were observed during squat and sitting, while the walking activities showed approximately half the internal rotation. The CAMS-HIGH100 loads were comparable to Bergmann and co-workers’, but have the additional benefit of synchronized kinematics. Stan’s loads are +11 to +56% higher than the ISO 14243 wear testing standard loads, while the kinematics exhibit markedly different curve shapes. Along with the original CAMS-Knee datasets, Stan’s data can be requested at cams-knee.orthoload.com.
Microfibrillated cellulose foams obtained by a straightforward freeze–thawing–drying procedure
Microfibrillated cellulose (MFC) is continuously gaining attention due to its outstanding mechanical properties, in particular high strength-to-weight ratio. Recently, more and more studies target the production of porous materials, such as foams, out of this natural resource. Commonly, an energy-consuming freeze–drying method is utilized for producing pure MFC porous structures from water-based suspensions, which renders these products particularly unattractive for industry. Although alternatives for foam production have been proposed, using either modified MFC or with various additives, the freeze–drying step is still one of the most critical bottle-neck of MFC foam production upscaling. A novel straightforward freeze–thawing–drying procedure assisted by the common additive urea was herein proposed. Such method allows the production of mechanically stable, lightweight MFC structures under low-cost ambient conditions drying. The influence of the cellulose fibril characteristics, the suspension formulation and the process parameters on the final foam properties have been studied in terms of porosity, density and mechanical properties.
Effect of two types of shoulder prosthesis on the muscle forces using a generic multibody model for different arm motions
Background This study aims to analyze the effects of a novel dual-bearing shoulder prosthesis and a conventional reverse shoulder prosthesis on the deltoid and rotator cuff muscle forces for four different arm motions. The dual-bearing prosthesis is a glenoid-sparing joint replacement with a moving center of rotation. It has been developed to treat rotator cuff arthropathy, providing an increased post-operative functionality. Methods A three-dimensional musculoskeletal OpenSim® model of an upper body, incorporating a natural gleno-humeral joint and a scapula-thoracic joint developed by Blana et al. (J Biomech 41: 1714-1721, 2008), was used as a reference for the natural shoulder. It was modified by integrating first a novel dual-bearing prosthesis, and second, a reverse shoulder prosthesis into the shoulder joint complex. Four different arm motions, namely abduction, scaption, internal and external rotation, were simulated using an inverse kinematics approach. For each of the three models, shoulder muscle forces and joint reaction forces were calculated with a 2 kg weight in the hand. Results In general, the maximal shoulder muscle force and joint reaction force values were in a similar range for both prosthesis models during all four motions. The maximal deltoid muscle forces in the model with the dual-bearing prosthesis were 18% lower for abduction and 3% higher for scaption compared to the natural shoulder. The maximal rotator cuff muscle forces in the model with the dual-bearing prosthesis were 36% lower for abduction and 1% higher for scaption compared to the natural shoulder. Although the maximal deltoid muscle forces in the model with the dual-bearing prosthesis in internal and external rotation were 52% and 64% higher, respectively, compared to the natural shoulder, the maximal rotator cuff muscle forces were 27% lower in both motions. Conclusion The study shows that the dual-bearing shoulder prosthesis is a feasible option for patients with rotator cuff tear and has a strong potential to be used as secondary as well as primary joint replacement. The study also demonstrates that computer simulations can help to guide the continued optimization of this particular design concept for successful clinical outcomes.
Experimental and computational evaluation of knee implant wear and creep under in vivo and ISO boundary conditions
Background Experimental knee implant wear testing according to ISO 14243 is a standard procedure, but it inherently possesses limitations for preclinical evaluations due to extended testing periods and costly infrastructure. In an effort to overcome these limitations, we hereby develop and experimentally validate a finite-element (FE)-based algorithm, including a novel cross-shear and contact pressure dependent wear and creep model, and apply it towards understanding the sensitivity of wear outcomes to the applied boundary conditions. Methods Specifically, we investigated the application of in vivo data for level walking from the publicly available “Stan” data set, which contains single representative tibiofemoral loads and kinematics derived from in vivo measurements of six subjects, and compared wear outcomes against those obtained using the ISO standard boundary conditions. To provide validation of the numerical models, this comparison was reproduced experimentally on a six-station knee wear simulator over 5 million cycles, testing the same implant Stan’s data was obtained from. Results Experimental implementation of Stan’s boundary conditions in displacement control resulted in approximately three times higher wear rates (4.4 vs. 1.6 mm 3 per million cycles) and a more anterior wear pattern compared to the ISO standard in force control. While a force-controlled ISO FE model was unable to reproduce the bench test kinematics, and thus wear rate, due to a necessarily simplified representation of the simulator machine, similar but displacement-controlled FE models accurately predicted the laboratory wear tests for both ISO and Stan boundary conditions. The credibility of the in silico wear and creep model was further established per the ASME V&V-40 standard. Conclusions The FE wear model is suitable for supporting future patient-specific models and development of novel implant designs. Incorporating the Stan data set alongside ISO boundary conditions emphasized the value of using measured kinematics in displacement control for reliably replicating in vivo joint mechanics in wear simulation. Future work should focus on expanding the range of daily activities simulated and addressing model sensitivity to contact mechanics to further enhance predictive accuracy.
Classification of Progressive Wear on a Multi-Directional Pin-on-Disc Tribometer Simulating Conditions in Human Joints-UHMWPE against CoCrMo Using Acoustic Emission and Machine Learning
Human joint prostheses experience wear failure due to the complex interactions between Ultra-High-Molecular-Weight Polyethylene (UHMWPE) and Cobalt-Chromium-Molybdenum (CoCrMo). This study uses the wear classification to investigate the gradual and progressive abrasive wear mechanisms in UHMWPE. Pin-on-disc tests were conducted under simulated in vivo conditions, monitoring wear using Acoustic Emission (AE). Two Machine Learning (ML) frameworks were employed for wear classification: manual feature extraction with ML classifiers and a contrastive learning-based Convolutional Neural Network (CNN) with ML classifiers. The CNN-based feature extraction approach achieved superior classification performance (94% to 96%) compared to manual feature extraction (81% to 89%). The ML techniques enable accurate wear classification, aiding in understanding surface states and early failure detection. Real-time monitoring using AE sensors shows promise for interventions and improving prosthetic joint design.
Ductile Compressive Behavior of Biomedical Alloys
The mechanical properties of ductile metals are generally assessed by means of tensile testing. Compression testing of metal alloys is usually only applied for brittle materials, or if the available specimen size is limited (e.g., in micro indentation). In the present study a previously developed test procedure for compressive testing was applied to determine the elastic properties and the yield curves of different biomedical alloys, such as 316L (two different batches), Ti-6Al-7Nb, and Co-28Cr-6Mo. The results were compared and validated against data from tensile testing. The converted flow curves for true stress vs. logarithmic strain of the compressive samples coincided well up to the yield strength of the tensile samples. The developed compression test method was shown to be reliable and valid, and it can be applied in cases where only small material batches are available, e.g., from additive manufacturing. Nevertheless, a certain yield asymmetry was observed with one of the tested 316L stainless steel alloys and the Co-28Cr-6Mo. Possible hypotheses and explanations for this yield asymmetry are given in the discussion section.
Estimating lumbar passive stiffness behaviour from subject-specific finite element models and in vivo 6DOF kinematics
Passive rotational stiffness of the osseo-ligamentous spine is an important input parameter for estimating in-vivo spinal loading using musculoskeletal models. These data are typically acquired from cadaveric testing. Increasingly, they are also estimated from subject-specific imaging-based finite element (FE) models, which are typically built from CT/MR data obtained in supine position and employ pure rotation kinematics. We explored the sensitivity of FE-based lumbar passive rotational stiffness to two aspects of functional in-vivo kinematics: (a) passive strain changes from supine to upright standing position, and (b) in-vivo coupled translation-rotation kinematics. We developed subject-specific FE models of four subjects’ L4L5 segments from supine CT images. Sagittally symmetric flexion was simulated in two ways: (i) pure flexion up to 12° under a 500 N follower load directly from the supine pose. (ii) First, a displacement-based approach was implemented to attain the upright pose, as measured using Dynamic Stereo X-ray (DSX) imaging. We then simulated in-vivo flexion using DSX imaging-derived kinematics. Datasets from weight-bearing motion with three different external weights [(4.5 kg), (9.1 kg), (13.6 kg)] were used. Accounting for supine-upright motion generated compressive pre-loads ≈ 468 N (±188 N) and a “pre-torque” ≈2.5 Nm (±2.2 Nm), corresponding to 25% of the reaction moment at 10° flexion (case (i)). Rotational stiffness estimates from DSX-based coupled translation-rotation kinematics were substantially higher compared to pure flexion. Reaction Moments were almost 90% and 60% higher at 5° and 10° of L4L5 flexion, respectively. Within-subject differences in rotational stiffness based on external weight were small, although between-subject variations were large.
Pelvic incidence–lumbar lordosis mismatch results in increased segmental joint loads in the unfused and fused lumbar spine
Purpose Symptomatic adjacent segment disease (ASD) has been reported to occur in up to 27 % of lumbar fusion patients. A previous study identified patients at risk according to the difference of pelvic incidence and lordosis. Patients with a difference between pelvic incidence and lumbar lordosis >15° have been found to have a 20 times higher risk for ASD. Therefore, it was the aim of the present study to investigate forces acting on the adjacent segment in relation to pelvic incidence–lumbar lordosis (PILL) mismatch as a measure of spino-pelvic alignment using rigid body modeling to decipher the underlying forces as potential contributors to degeneration of the adjacent segment. Methods Sagittal configurations of 81 subjects were reconstructed in a musculoskeletal simulation environment. Lumbar spine height was normalized, and body and segmental mass properties were kept constant throughout the population to isolate the effect of sagittal alignment. A uniform forward/backward flexion movement (0°–30°–0°) was simulated for all subjects. Intervertebral joint loads at lumbar level L3–L4 and L4–L5 were determined before and after simulated fusion. Results In the unfused state, an approximately linear relationship between sagittal alignment and intervertebral loads could be established (shear: 0° flexion r  = 0.36, p  < 0.001, 30° flexion r  = 0.48, p  < 0.001; compression: 0° flexion r  = 0.29, p  < 0.01, 30° flexion r  = 0.40, p  < 0.001). Additionally, shear changes during the transition from upright to 30° flexed posture were on average 32 % higher at level L3–L4 and 14 % higher at level L4–L5 in alignments that were clinically observed to be prone to ASD. Simulated fusion affected shear forces at the level L3–L4 by 15 % (L4–L5 fusion) and 23 % (L4–S1 fusion) more for alignments at risk for ASD. Conclusion Higher adjacent segment shear forces in alignments at risk for ASD already prior to fusion provide a mechanistic explanation for the clinically observed correlation between PILL mismatch and rate of adjacent segment degeneration.
Are asymmetric metal markings on the cone surface of ceramic femoral heads an indication of entrapped debris?
Background The probability of in vivo failure of ceramic hip joint implants is very low (0.004-0.05%). In addition to material flaws and overloading, improper handling during implantation can induce fractures of the ceramic ball head in the long term. Identifying the causes of an in vivo fracture contributes to improved understanding and potentially to further reduction of the fracture probability for patients. Asymmetric metal markings on the cone surface of in vivo ball head fractures have been reported. The question, therefore, is whether asymmetric loading is the sole cause or whether additional factors, specifically contamination entrapped in the taper fit, also contribute or are even the main cause. Methods The influence of the asymmetric physiological load configuration on resulting metal markings in the cone surface of an alumina femoral ball head with and without biological contaminants was investigated. Static and cyclic tests on ball heads were carried out in a load configuration of 0° (axisymmetric) and 40° in a physiological environment. The analysis of the metal marking was carried out to gain a better understanding of the processes that contribute to the generation of metal marking. Fractography was carried out to determine the fracture initiation of failed ball heads. Results Different types and sizes of residuals entrapped in the conical surface are shown to yield strongly asymmetric metal marking patterns. All heads tested without contaminants exhibited an almost homogenous distribution of residual metal markings around the circumference of the ceramic cone surface at the proximal end of the bore hole. The failure of ball heads that contained entrapped contaminants revealed a common fracture pattern. The site of fracture initiation on two of the failed heads was in the entrance region of the bore hole on the superior half of the head. Conclusion Asymmetric metal markings observed on the ball heads tested in this investigation are most probably caused by the presence of contaminants entrapped in the taper fit. Homogenous metal mark distributions around the circumference indicate proper assembly of the ball head without entrapped contaminants. It should, however, be noted that different taper designs may possibly result in different marking patterns.