Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Language
      Language
      Clear All
      Language
  • Subject
      Subject
      Clear All
      Subject
  • Item Type
      Item Type
      Clear All
      Item Type
  • Discipline
      Discipline
      Clear All
      Discipline
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
34 result(s) for "Woodburn, William"
Sort by:
Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures – a biomechanical investigation
Background The aim of this study was to investigate the biomechanical performance of novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Methods Sixteen pairs of human cadaveric knees were used to simulate two-part simple transverse AO/OTA 34-C1 and five-part complex AO/OTA 34-C3 patella fractures. The complex fracture pattern was characterized with a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral and an inferior fragment mimicking comminution around the distal patella pole. Eight pairs with simple fractures were split for fixation via either tension band wiring (TBW) through two parallel cannulated screws or anterior variable-angle locked plating, whereas other eight pairs with complex fractures were split for either TBW through two parallel cannulated screws plus circumferential cerclage wiring, or anterior variable-angle locked plating using a cortical caudo-cranial polar screw. Each specimen was tested over 5000 cycles with a range of motion from 90° flexion to full extension by pulling on the quadriceps tendon. Interfragmentary movements were captured by motion tracking. Results For both fracture types, the longitudinal and shear articular displacements, measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following anterior variable-angle locked plating versus TBW, p ≤ 0.01. Conclusions From a biomechanical perspective, anterior locked plating of both simple and complex patella fractures resulted in less interfragmentary displacement under extended cyclic loading.
Risk Factors for Helminth, Malaria, and HIV Infection in Pregnancy in Entebbe, Uganda
Infections during pregnancy may have serious consequences for both mother and baby. Assessment of risk factors for infections informs planning of interventions and analysis of the impact of infections on health outcomes. To describe risk factors for helminths, malaria and HIV in pregnant Ugandan women before intervention in a trial of de-worming in pregnancy. The trial recruited 2,507 pregnant women between April 2003 and November 2005. Participants were interviewed and blood and stool samples obtained; location of residence at enrolment was mapped. Demographic, socioeconomic, behavioral and other risk factors were modelled using logistic regression. There was a high prevalence of helminth, malaria and HIV infection, as previously reported. All helminths and malaria parasitemia were more common in younger women, and education was protective against every infection. Place of birth and/or tribe affected all helminths in a pattern consistent with the geographical distribution of helminth infections in Uganda. Four different geohelminths (hookworm, Trichuris, Ascaris and Trichostrongylus) showed a downwards trend in prevalence during the enrolment period. There was a negative association between hookworm and HIV, and between hookworm and low CD4 count among HIV-positive women. Locally, high prevalence of schistosomiasis and HIV occurred in lakeshore communities. Interventions for helminths, malaria and HIV need to target young women both in and out of school. Antenatal interventions for malaria and HIV infection must continue to be promoted. Women originating from a high risk area for a helminth infection remain at high risk after migration to a lower-risk area, and vice versa, but overall, geohelminths seem to be becoming less common in this population. High risk populations, such as fishing communities, require directed effort against schistosomiasis and HIV infection.
Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study
Introduction Treatment of both simple and complex patella fractures is a challenging clinical problem. Although tension band wiring has been the standard of care, it can be associated with high complication rates. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Materials and methods Sixteen pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34-C1 or five-part complex AO/OTA 34-C3 patella fractures by means of osteotomies, with each fracture model created in eight pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior (central distal) fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full extension. Interfragmentary movements were captured via motion tracking. Results For both fracture types, the articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p ≤ 0.01. Conclusions From a biomechanical perspective, lateral rim variable angle locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading.
Gender roles, computer attitudes, and dyadic computer interaction performance in college students
Examines effects of several mediating factors (experimenter and partner sex, sex typing, and past experience) on a computer-interaction task completed by 154 male and 223 female college students in dyads. Computer experience is related to computer experience for all students. Findings support the expected pattern of male advantage but highlight the complexity of sex differences in computer interactions. (SLD)