Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
103
result(s) for
"Xiong, Shuping"
Sort by:
A Dynamic Time Warping Based Algorithm to Evaluate Kinect-Enabled Home-Based Physical Rehabilitation Exercises for Older People
2019
Older people face difficulty engaging in conventional rehabilitation exercises for improving physical functions over a long time period due to the passive nature of the conventional exercise, inconvenience, and cost. This study aims to develop and validate a dynamic time warping (DTW) based algorithm for assessing Kinect-enabled home-based physical rehabilitation exercises, in order to support auto-coaching in a virtual gaming environment. A DTW-based algorithm was first applied to compute motion similarity between two time series from an individual user and a virtual coach. We chose eight bone vectors of the human skeleton and body orientation as the input features and proposed a simple but innovative method to further convert the DTW distance to a meaningful performance score in terms of the percentage (0–100%), without training data and experience of experts. The effectiveness of the proposed algorithm was validated through a follow-up experiment with 21 subjects when playing a Tai Chi exergame. Results showed that the algorithm scores had a strong positive linear relationship (r = 0.86) with experts’ ratings and the calibrated algorithm scores were comparable to the gold standard. These findings suggested that the DTW-based algorithm could be effectively used for automatic performance evaluation of an individual when performing home-based rehabilitation exercises.
Journal Article
A Large-Scale Open Motion Dataset (KFall) and Benchmark Algorithms for Detecting Pre-impact Fall of the Elderly Using Wearable Inertial Sensors
by
Yu, Xiaoqun
,
Jang, Jaehyuk
,
Xiong, Shuping
in
Activities of daily living
,
algorithm development
,
Algorithms
2021
Research on pre-impact fall detection with wearable inertial sensors (detecting fall accidents prior to body-ground impacts) has grown rapidly in the past decade due to its great potential for developing an on-demand fall-related injury prevention system. However, most researchers use their own datasets to develop fall detection algorithms and rarely make these datasets publicly available, which poses a challenge to fairly evaluate the performance of different algorithms on a common basis. Even though some open datasets have been established recently, most of them are impractical for pre-impact fall detection due to the lack of temporal labels for fall time and limited types of motions. In order to overcome these limitations, in this study, we proposed and publicly provided a large-scale motion dataset called “KFall,” which was developed from 32 Korean participants while wearing an inertial sensor on the low back and performing 21 types of activities of daily living and 15 types of simulated falls. In addition, ready-to-use temporal labels of the fall time based on synchronized motion videos were published along with the dataset. Those enhancements make KFall the first public dataset suitable for pre-impact fall detection, not just for post-fall detection. Importantly, we have also developed three different types of latest algorithms (threshold based, support-vector machine, and deep learning), using the KFall dataset for pre-impact fall detection so that researchers and practitioners can flexibly choose the corresponding algorithm. Deep learning algorithm achieved both high overall accuracy and balanced sensitivity (99.32%) and specificity (99.01%) for pre-impact fall detection. Support vector machine also demonstrated a good performance with a sensitivity of 99.77% and specificity of 94.87%. However, the threshold-based algorithm showed relatively poor results, especially the specificity (83.43%) was much lower than the sensitivity (95.50%). The performance of these algorithms could be regarded as a benchmark for further development of better algorithms with this new dataset. This large-scale motion dataset and benchmark algorithms could provide researchers and practitioners with valuable data and references to develop new technologies and strategies for pre-impact fall detection and proactive injury prevention for the elderly.
Journal Article
TouchView: Mid-Air Touch on Zoomable 2D View for Distant Freehand Selection on a Virtual Reality User Interface
2024
Selection is a fundamental interaction element in virtual reality (VR) and 3D user interfaces (UIs). Raycasting, one of the most common object selection techniques, is known to have difficulties in selecting small or distant objects. Meanwhile, recent advancements in computer vision technology have enabled seamless vision-based hand tracking in consumer VR headsets, enhancing accessibility to freehand mid-air interaction and highlighting the need for further research in this area. This study proposes a new technique called TouchView, which utilizes a virtual panel with a modern adaptation of the Through-the-Lens metaphor to improve freehand selection for VR UIs. TouchView enables faster and less demanding target selection by allowing direct touch interaction with the magnified object proxies reflected on the panel view. A repeated-measures ANOVA on the results of a follow-up experiment on multitarget selection with 23 participants showed that TouchView outperformed the current market-dominating freehand raycasting technique, Hybrid Ray, in terms of task performance, perceived workload, and preference. User behavior was also analyzed to understand the underlying reasons for these improvements. The proposed technique can be used in VR UI applications to enhance the selection of distant objects, especially for cases with frequent view shifts.
Journal Article
Epidemiology of fall and its socioeconomic risk factors in community-dwelling Korean elderly
2020
Although falls in older people are a major public health problem globally, to date there are scarce reports on socioeconomic risk factors for falls. The aim of the present study was to investigate the epidemiology of fall, its associated socioeconomic risk factors and relative importance among community-dwelling Korean elderly. Secondary analysis of national survey data with 31,684 community-dwelling Korean elderly was performed. Eleven socioeconomic factors (age, gender, household type, marital status, education level, current occupation, past occupation, income, wealth, number of children, and relationship satisfaction) were selected for analysing their associations with the epidemiology of fall through complex sample analysis and logistic regressions. Results showed that 15.9%~25.1% of community-dwelling Korean elderly experienced fall yearly. The groups with significantly higher fall risks were identified as older aged, being female, not married or widowed, less educated, unemployed, and having lower relationship satisfaction. Gender (adjusted odds ratio-AOR = 1.548) and relationship satisfaction (AOR = 1.276) were the utmost important fall risk factors, indicating being older female with lower relationship satisfaction were the foremost socioeconomic characteristics for risk of falling. These findings could contribute to better understanding of the socioeconomic fall risk profiles among Korean elderly and effective strategies for fall prevention.
Journal Article
Accuracy of Base of Support Using an Inertial Sensor Based Motion Capture System
2017
The potential of miniature inertial sensors for human balance and gait analysis appears promising. Base of support (BOS), together with its interaction with center of mass, is a critical indicator in above mentioned research fields. This study aims to evaluate the accuracy of Xsens MVN BIOMECH, a commercial widely used inertial sensor-based motion capture system, for measuring static BOS and examine the effect of different task complexity on the accuracy. Eleven young males participated in this study and went through eleven different experimental tasks. Results showed there were considerable errors in estimating BOS area (error ranged from −12.6% to +64.6%) from Xsens MVN and a large error in foot separation distance when there was knee flexion. The estimated BOS area from MVN was smaller than the ground truth from footprint when there was no knee flexion, and larger when there was knee flexion, and it increased monotonically along with the knee flexion angles. Wrongly estimated foot separations, mainly caused by knee flexion, and the initial system estimation error on BOS, were two major reasons for error and instability of BOS estimation. The findings suggested that caution should be taken when using Xsens MVN BIOMECH to estimate BOS and foot position-related measurements, especially for postures/motions with knee flexion.
Journal Article
The role of glutamine synthetase isozymes in enhancing nitrogen use efficiency of N-efficient winter wheat
2017
Glutamine synthetase (GS) isozymes play critical roles in nitrogen (N) metabolism. However, the exact relationship between GS and nitrogen use efficiency (NUE) remain unclear. We have selected and compared two wheat cultivars, YM49 and XN509, which were identified as the N-efficient and N-inefficient genotypes, respectively. In this study, agronomical, morphological, physiological and biochemical approaches were performed. The results showed that
TaGS1
was high expressed post-anthesis, and
TaGS2
was highly expressed pre-anthesis in N-efficient genotype compared to N-inefficient genotype. GS1 and GS2 isozymes were also separated by native-PAGE and found that the spatial and temporal distribution of GS isozymes, their expression of gene and protein subunits in source-sink-flow organs during development periods triggered the pool strength and influenced the N flow. According to the physiological role of GS isozymes, we illustrated four metabolic regulation points, by which acting collaboratively in different organs, accelerating the transport of nutrients to the grain. It suggested that the regulation of GS isozymes may promote flow strength and enhance NUE by a complex C-N metabolic mechanism. The relative activity or amount of GS1 and GS2 isozymes could be a potential marker to predict and select wheat genotypes with enhanced NUE.
Journal Article
Acute Effects of Carbon Fiber Insole on Three Aspects of Sports Performance, Lower Extremity Muscle Activity, and Subjective Comfort
2023
Carbon fiber insole (CFI), which is lightweight and stiff to reduce energy loss and help wearers perform better in sports, has recently been introduced. However, reports are scarce on the effects of CFI on sports performance, muscle activation, and wearing comfort. This study investigated the acute effects of CFI on sports performance, lower extremity muscle activity, and subjective comfort. Thirty young healthy males with shoe sizes between 260 and 270 mm performed various sports tasks (power generation, agility, and speed) and treadmill runs with wearable sensors under two experimental insole conditions (benchmark insole as a baseline, CFI). The results showed that, compared to the benchmark insole, CFI significantly improved sports performance in terms of power generation (~1.5%) and agility (~1%). However, it activated more of the Tibialis Anterior (~0.7%) and Gastrocnemius Medialis (~0.8%) muscles, and was perceived to be stiffer and less comfortable. These findings suggested that CFI could improve sports performance, but could cause more lower extremity muscle activation and subjective discomfort.
Journal Article
A Novel Hybrid Deep Neural Network to Predict Pre-impact Fall for Older People Based on Wearable Inertial Sensors
2020
Falls in the elderly is a major public health concern due to its high prevalence, serious consequences and heavy burden on the society. Many falls in older people happen within a very short time, which makes it difficult to predict a fall before it occurs and then to provide protection for the person who is falling. The primary objective of this study was to develop deep neural networks for predicting a fall during its initiation and descending but before the body impacts to the ground so that a safety mechanism can be enabled to prevent fall-related injuries. We divided the falling process into three stages (non-fall, pre-impact fall and fall) and developed deep neutral networks to perform three-class classification. Three deep learning models, convolutional neural network (CNN), long short term memory (LSTM), and a novel hybrid model integrating both convolution and long short term memory (ConvLSTM) were proposed and evaluated on a large public dataset of various falls and activities of daily living (ADL) acquired with wearable inertial sensors (accelerometer and gyroscope). Fivefold cross validation results showed that the hybrid ConvLSTM model had mean sensitivities of 93.15, 93.78, and 96.00% for non-fall, pre-impact fall and fall, respectively, which were higher than both LSTM (except the fall class) and CNN models. ConvLSTM model also showed higher specificities for all three classes (96.59, 94.49, and 98.69%) than LSTM and CNN models. In addition, latency test on a microcontroller unit showed that ConvLSTM model had a short latency of 1.06 ms, which was much lower than LSTM model (3.15 ms) and comparable with CNN model (0.77 ms). High prediction accuracy (especially for pre-impact fall) and low latency on the microboard indicated that the proposed hybrid ConvLSTM model outperformed both LSTM and CNN models. These findings suggest that our proposed novel hybrid ConvLSTM model has great potential to be embedded into wearable inertial sensor-based systems to predict pre-impact fall in real-time so that protective devices could be triggered in time to prevent fall-related injuries for older people.
Journal Article
Validity and Reliability of Upper Limb Functional Assessment Using the Microsoft Kinect V2 Sensor
2019
Objective. To quantify the concurrent accuracy and the test-retest reliability of a Kinect V2-based upper limb functional assessment system. Approach. Ten healthy males performed a series of upper limb movements, which were measured concurrently with Kinect V2 and the Vicon motion capture system (gold standard). Each participant attended two testing sessions, seven days apart. Four tasks were performed including hand to contralateral shoulder, hand to mouth, combing hair, and hand to back pocket. Upper limb kinematics were calculated using our developed kinematic model and the UWA model for Kinect V2 and Vicon. The interdevice coefficient of multiple correlation (CMC) and the root mean squared error (RMSE) were used to evaluate the validity of the kinematic waveforms. Mean absolute bias and Pearson’s r correlation were used to evaluate the validity of the angles at the points of target achieved (PTA) and the range of motion (ROM). The intersession CMC and RMSE and the intraclass correlation coefficient (ICC) were used to assess the test-retest reliability of Kinect V2. Main Results. Both validity and reliability are found to be task-dependent and plane-dependent. Kinect V2 had good accuracy in measuring shoulder and elbow flexion/extension angular waveforms (CMC>0.87), moderate accuracy of measuring shoulder adduction/abduction angular waveforms (CMC=0.69-0.82), and poor accuracy of measuring shoulder internal/external angles (CMC<0.6). We also found high test-retest reliability of Kinect V2 in most of the upper limb angular waveforms (CMC=0.75-0.99), angles at the PTA (ICC=0.65-0.91), and the ROM (ICC=0.68-0.96). Significance. Kinect V2 has great potential as a low-cost, easy implemented device for assessing upper limb angular waveforms when performing functional tasks. The system is suitable for assessing relative within-person change in upper limb motions over time, such as disease progression or improvement due to intervention.
Journal Article
TinyFallNet: A Lightweight Pre-Impact Fall Detection Model
2023
Falls represent a significant health concern for the elderly. While studies on deep learning-based preimpact fall detection have been conducted to mitigate fall-related injuries, additional efforts are needed for embedding in microcomputer units (MCUs). In this study, ConvLSTM, the state-of-the-art model, was benchmarked, and we attempted to lightweight it by leveraging features from image-classification models VGGNet and ResNet while maintaining performance for wearable airbags. The models were developed and evaluated using data from young subjects in the KFall public dataset based on an inertial measurement unit (IMU), leading to the proposal of TinyFallNet based on ResNet. Despite exhibiting higher accuracy (97.37% < 98.00%) than the benchmarked ConvLSTM, the proposed model requires lower memory (1.58 MB > 0.70 MB). Additionally, data on the elderly from the fall data of the FARSEEING dataset and activities of daily living (ADLs) data of the KFall dataset were analyzed for algorithm validation. This study demonstrated the applicability of image-classification models to preimpact fall detection using IMU and showed that additional tuning for lightweighting is possible due to the different data types. This research is expected to contribute to the lightweighting of deep learning models based on IMU and the development of applications based on IMU data.
Journal Article