Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
3 result(s) for "Yu, Stephanie CY"
Sort by:
High-Resolution Profiling of Fetal DNA Clearance from Maternal Plasma by Massively Parallel Sequencing
With the advent of massively parallel sequencing (MPS), DNA analysis can now be performed in a genomewide manner. Recent studies have demonstrated the high precision of MPS for quantifying fetal DNA in maternal plasma. In addition, paired-end sequencing can be used to determine the size of each sequenced DNA fragment. We applied MPS in a high-resolution investigation of the clearance profile of circulating fetal DNA. Using paired-end MPS, we analyzed serial samples of maternal plasma collected from 13 women after cesarean delivery. We also studied the transrenal excretion of circulating fetal DNA in 3 of these individuals by analyzing serial urine samples collected after delivery. The clearance of circulating fetal DNA occurred in 2 phases, with different kinetics. The initial rapid phase had a mean half-life of approximately 1 h, whereas the subsequent slow phase had a mean half-life of approximately 13 h. The final disappearance of circulating fetal DNA occurred at about 1 to 2 days postpartum. Although transrenal excretion was involved in the clearance of circulating fetal DNA, it was not the major route. Furthermore, we observed significant changes in the size profiles of circulating maternal DNA after delivery, but we did not observe such changes in circulating fetal DNA. MPS of maternal plasma and urinary DNA permits high-resolution study of the clearance profile of circulating fetal DNA.
Combined Count- and Size-Based Analysis of Maternal Plasma DNA for Noninvasive Prenatal Detection of Fetal Subchromosomal Aberrations Facilitates Elucidation of the Fetal and/or Maternal Origin of the Aberrations
Noninvasive prenatal detection of fetal subchromosomal copy number aberrations (CNAs) can be achieved through massively parallel sequencing of maternal plasma DNA. However, when a mother herself is a carrier of a CNA, one cannot discern if her fetus has inherited the CNA. In addition, false-positive results would become more prevalent when more subchromosomal regions are analyzed. We used a strategy that combined count- and size-based analyses of maternal plasma DNA for the detection of fetal subchromosomal CNAs in 7 target regions for 10 test cases. For the 5 cases in which CNAs were present only in the fetus, the size-based approach confirmed the aberrations detected by the count-based approach. For the 5 cases in which the mother herself carried an aberration, we successfully deduced that 3 of the fetuses had inherited the aberrations and that the other 2 fetuses had not inherited the aberrations. No false positives were observed in this cohort. Combined count- and size-based analysis of maternal plasma DNA permits the noninvasive elucidation of whether a fetus has inherited a CNA from its mother who herself is a carrier of the CNA. This strategy has the potential to improve the diagnostic specificity of noninvasive prenatal testing.
Noninvasive Prenatal Molecular Karyotyping from Maternal Plasma. e60968
Fetal DNA is present in the plasma of pregnant women. Massively parallel sequencing of maternal plasma DNA has been used to detect fetal trisomies 21, 18, 13 and selected sex chromosomal aneuploidies noninvasively. Case reports describing the detection of fetal microdeletions from maternal plasma using massively parallel sequencing have been reported. However, these previous reports were either polymorphism-dependent or used statistical analyses which were confined to one or a small number of selected parts of the genome. In this report, we reported a procedure for performing noninvasive prenatal karyotyping at 3 Mb resolution across the whole genome through the massively parallel sequencing of maternal plasma DNA. This method has been used to analyze the plasma obtained from 6 cases. In three cases, fetal microdeletions have been detected successfully from maternal plasma. In two cases, fetal microduplications have been detected successfully from maternal plasma. In the remaining case, the plasma DNA sequencing result was consistent with the pregnant mother being a carrier of a microduplication. Simulation analyses were performed for determining the number of plasma DNA molecules that would need to be sequenced and aligned for enhancing the diagnostic resolution of noninvasive prenatal karyotyping to 2 Mb and 1 Mb. In conclusion, noninvasive prenatal molecular karyotyping from maternal plasma by massively parallel sequencing is feasible and would enhance the diagnostic spectrum of noninvasive prenatal testing.