Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
89 result(s) for "Zanon, Francesco"
Sort by:
Stylet-driven Leads or Lumenless Leads for Conduction System Pacing
Stylet-driven leads have been recently introduced for conduction system pacing, while most of the previous experience has been obtained with lumenless leads. Design and structural characteristics of both lead types are significantly different, resulting in different implant techniques and independent learning curves. Lead performance appears to be comparable, whereas data on direct comparison of clinical outcomes are scarce. Currently, there are no specific clinical scenarios favouring the use of one lead type over another and the decision should rely on the individual experience of the implanter.
The weakest point of cardiac resynchronization therapy: new technologies facing old terminology
Patients with symptomatic heart failure (HF) and left bundle branch block (LBBB) are currently treated with biventricular pacing (BiV) which has a Class IA recommendation. Given the possibility to re-establish the inter and intra-ventricular synchrony, BiV is commonly referred to as cardiac resynchronization therapy (CRT). This wording is widely utilized and over time the terms BiV and CRT have become interchangeable. Conduction system pacing (CSP) is emerging as a valid therapeutic opportunity to obtain CRT restoring the native conduction via the Purkinje network. Therefore the acronym CRT is no longer synonymous with BiV only but could also refer to CSP. A terminology update is needed to include the resource of CSP to ensure better communication among all the stakeholders involved in managing recipients of cardiac devices and should be a fundamental step in advancing the quality of patient care. Making use of the NBG code to describe the implantable cardiac device would ease such terminology update, since only the first three positions of the five letters NBG code are commonly utilized, while the last two are rarely used.
Is Conduction System Pacing a Valuable Alternative to Biventricular Pacing for Cardiac Resynchronization Therapy?
Cardiac resynchronization therapy (CRT) significantly improves clinical outcomes in patients with ventricular systolic dysfunction and dyssynchrony. Biventricular pacing (BVP) has a class IA recommendation for patients with symptomatic heart failure with reduced ejection fraction (HFrEF) and left bundle branch block (LBBB). However, approximately 30% of patients have a poor therapeutic response and do not achieve real clinical benefit. Pre-implant imaging, together with tailored programming and dedicated device algorithms, have been proposed as possible tools to improve success rate but have shown inconsistent results. Over the last few years, conduction system pacing (CSP) is becoming a real and attractive alternative to standard BVP as it can restore narrow QRS in patients with bundle branch block (BBB) by stimulating and recruiting the cardiac conduction system, thus ensuring true resynchronization. It includes His bundle pacing (HBP) and left bundle branch area pacing (LBBAP). Preliminary data coming from small single-center experiences are very promising and have laid the basis for currently ongoing randomized controlled trials comparing CSP with BVP. The purpose of this review is to delve into the emerging role of CSP as an alternative method of achieving CRT. After framing CSP in a historical perspective, the pathophysiological rationale and available clinical evidence will be examined, and crucial technical aspects will be discussed. Finally, evidence gaps and future perspectives on CSP as a technique of choice to deliver CRT will be summarized.
Energy Saving in Permanent Cardiac Pacing: Pulse Waveform and Charge Balancing Deserve Consideration
The pacing pulse produced by implantable stimulators can be described as a truncated exponential decay from the starting peak amplitude, corresponding to the discharge of the output stage capacitance (reservoir and isolation capacitors, in series) along the application time. Pulse decay and charge balancing have relevant implications on the ideal setting of a pacing device, as demonstrated by mathematical predictions based on well-acknowledged theoretical statements. Successful stimulation is achieved with minimum energy expense at a pulse duration shorter than the chronaxie time, which represents the upper border of the advisable duration interval. With any start amplitude, the stimulation safety margin can be improved by a duration increase beyond the chronaxie only up to an absolute limit (longest useful duration), which depends on the chronaxie and the pulse time-constant. At the longest useful duration, the threshold start amplitude is at the minimum and cannot decrease any further, though it and the corresponding pulse mean amplitude largely exceed the rheobase. The overall pacing performance is affected, in addition, by the load resistance and the electrode capacitance. Pulse amplitude decay limits the effectiveness of extended duration in implantable stimulators, making short pulses preferable whenever possible. Proper pulse settings based on actual waveform properties can prevent energy waste and reduce pacing consumption, thus prolonging the service life of the stimulator.
Physiological pacing to improve cardiac resynchronization therapy non-responder and a tryst with calcified septum—a case report
Background As per the literature, patients with intraventricular conduction delay (IVCD) do not respond well to cardiac resynchronization therapy (CRT) alone. They need advanced technological approach and out of the box thinking for a good response. Case Ours is a case of ischemic cardiomyopathy with wide QRS-IVCD, a non-responder to CRT. While planning for replacement of the device for early replacement indicator (ERI), we decided to do His-optimized CRT/left bundle optimized CRT (HOT-CRT/LOT-CRT) for the patient. Conclusion The challenges we faced with the present available hardware paved a way for insisting on the limitation of the available lumenless lead to penetrate calcified the septum and importance of the pre-procedure evaluation of intraventricular septum (IVS) for calcification by more than just echocardiography.
Hemodynamic comparison of different multisites and multipoint pacing strategies in cardiac resynchronization therapies
PurposeIn order to increase the responder rate to CRT, stimulation of the left ventricular (LV) from multiple sites has been suggested as a promising alternative to standard biventricular pacing (BIV). The aim of the study was to compare, in a group of candidates for CRT, the effects of different pacing configurations—BIV, triple ventricular (TRIV) by means of two LV leads, multipoint (MPP), and multipoint plus a second LV lead (MPP + TRIV) pacing—on both hemodynamics and QRS duration.MethodsFifteen patients (13 male) with permanent AF (mean age 76 ± 7 years; left ventricular ejection fraction 33 ± 7%; 7 with ischemic cardiomyopathy; mean QRS duration 178 ± 25 ms) were selected as candidates for CRT. Two LV leads were positioned in two different branches of the coronary sinus. Acute hemodynamic response was evaluated by means of a RADI pressure wire as the variation in LVdp/dtmax.ResultsPer patient, 2.7 ± 0.7 veins and 5.2 ± 1.9 pacing sites were evaluated. From baseline values of 998 ± 186 mmHg/s, BIV, TRIV, MPP, and MPP-TRIV pacing increased LVdp/dtmax to 1200 ± 281 mmHg/s, 1226 ± 284 mmHg/s, 1274 ± 303 mmHg, and 1289 ± 298 mmHg, respectively (p < 0.001). Bonferroni post-hoc analysis showed significantly higher values during all pacing configurations in comparison with the baseline; moreover, higher values were recorded during MPP and MPP + TRIV than at the baseline or during BIV and also during MPP + TRIV than during TRIV. Mean QRS width decreased from 178 ± 25 ms at the baseline to 171 ± 21, 167 ± 20, 168 ± 20, and 164 ± 15 ms, during BIV, TRIV, MPP, and MPP-TRIV, respectively (p < 0.001).ConclusionsIn patients with AF, the acute response to CRT improves as the size of the early activated LV region increases.
Pre-existing atrial fibrillation is associated with increased mortality in COVID-19 Patients
PurposeThe impacts of pre-existing atrial fibrillation (AF) on COVID-19-associated outcomes are unclear. We conducted a systematic review and meta-analysis to investigate the pooled prevalence of pre-existing AF and its short-term mortality risk in COVID-19 patients.MethodsPreferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed in abstracting data and assessing validity. We searched MEDLINE and Scopus to locate all the articles published up to January 31, 2021, reporting data on pre-existing AF among COVID-19 survivors and non-survivors. The pooled prevalence of pre-existing AF was calculated using a random effects model and presenting the related 95% confidence interval (CI), while the mortality risk was estimated using the Mantel-Haenszel random effects models with odds ratio (OR) and related 95% CI. Statistical heterogeneity was measured using the Higgins I2 statistic.ResultsTwelve studies, enrolling 15.562 COVID-19 patients (mean age 71.6 years), met the inclusion criteria and were included in the final analysis. The pooled prevalence of pre-existing AF was 11.0% of cases (95% CI: 7.8–15.2%, p < 0.0001) with high heterogeneity (I2 = 95.2%). Pre-existing AF was associated with higher risk of short-term death (OR 2.22, 95% CI 1.47–3.36, p < 0.0001), with high heterogeneity (I2 = 79.1%).ConclusionPre-existing AF is present in about 11% of COVID-19 cases but results associated with an increased risk of short-term mortality.
Hydrometeorological Analysis of the 29 August 2003 Flash Flood in the Eastern Italian Alps
The 29 August 2003 storm on the upper Tagliamento River basin in the eastern Italian Alps is examined as a prototype for organized convective systems that dominate the upper tail of the precipitation frequency distribution and are likely responsible for the majority of flash flood peaks in this area. The availability of high-resolution rainfall estimates from radar observations and rain gauge networks, together with flood response observations derived from stream gauge data and post-event surveys, provides the opportunity to study the hydrometeorological and hydrological mechanisms associated with this extreme storm and the associated flood. The flood occurred at the end of a climatic anomaly of prolonged drought and warm conditions over Europe and the Mediterranean region. A characteristic of the event is its organization in well-defined banded structures, some of which persisted in the same locations for the duration of the event. The steadiness of these rainbands led to highly variable precipitation accumulations and, associated with orographic enhancement, played a central role in the space–time organization of the storm. Two dominant controls on extreme flood response are recognized and analyzed: steadiness of convective bands and dry antecedent soil moisture conditions.
Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience
Background The Medtronic SelectSecure Model 3830 lumenless lead (Medtronic, Inc., Minneapolis, MN) is commonly used for conduction system pacing (CSP). However, with this increased use, the potential need for transvenous lead extraction (TLE) also will increase. While extraction of endocardial 3830 leads is rather well described especially in pediatric and adult congenital heart disease population, there is very limited data on extraction of CSP leads. In the present study, we reported our preliminary experience on TLE of CSP leads and provided technical considerations. Methods The study population comprised 6 consecutive patients (67% male; mean age 70 ± 22 years) with CSP leads (3830 leads), including left bundle branch pacing (LBBP) lead ( n  = 3) and His pacing lead ( n  = 3) undergoing TLE. Overall target leads were 17. The mean implant duration time of CSP leads was 97 ± 90 months [range 8–193). Results Manual traction was successful in 2 cases and mechanical extraction tools were required in the remaining cases. Sixteen leads (94%) were completely extracted, whereas incomplete removal was observed in one lead (6%) among 1 patient. Of note, in the only lead incompletely removed, we observed retention of < 1-cm remnant of lead material consisting of the screw of 3830 LBBP lead into the interventricular septum. No failure of lead extraction was reported and no major complications occurred. Conclusions Our findings demonstrated that at an experienced center the success of TLE of chronically implanted CSP leads is high in the absence of major complications also when mechanical extraction tools are needed.