Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
7 result(s) for "Ziagkos, Dimitrios"
Sort by:
Additive effect of erythropoietin use on exercise-induced endothelial activation and hypercoagulability in athletes
Purpose Recombinant human erythropoietin (rHuEPO) is known to increase thrombotic risk in patients and might have similar effects in athletes abusing the drug. rHuEPO is prohibited by anti-doping legislation, but this risk has not been investigated thoroughly. This analysis was designed to evaluate whether rHuEPO impacts hemostatic profile and endothelial and platelet activation markers in trained subjects, and whether the combination with exercise affects exercise induced alterations. Methods This double-blind, randomized, placebo-controlled trial enrolled healthy, trained male cyclists aged 18–50 years. Participants were randomly allocated (1:1) to receive subcutaneous injections of rHuEPO (epoetin-β; mean dose 6000 IU per week) or placebo (0.9% NaCl) for 8 weeks. Subjects performed five maximal exercise tests and a road race, coagulation and endothelial/platelet markers were measured at rest and directly after each exercise effort. Results rHuEPO increased P-selectin (+ 7.8% (1.5–14.5), p  = 0.02) and E-selectin (+ 8.6% (2.0–15.7), p  = 0.01) levels at rest. Maximal exercise tests significantly influenced all measured coagulation and endothelial/platelet markers, and in the rHuEPO group maximal exercise tests led to 15.3% ((7.0–24.3%), p  = 0.0004) higher E-selectin and 32.1% ((4.6–66.8%), p  = 0.0207) higher Platelet factor 4 (PF4) levels compared to the placebo group. Conclusion In conclusion, rHuEPO treatment resulted in elevated E- and P-selectin levels in trained cyclists, indicating enhanced endothelial activation and/or platelet reactivity. Exercise itself induces hypercoagulability, and the combination of rHuEPO and exercise increased E-selectin and PF4 levels more than either intervention alone. Based on this, exercise potentially increases thrombotic risk, a risk that might be enhanced in combination with rHuEPO use.
Mitochondrial function, grip strength, and activity are related to recovery of mobility after a total knee arthroplasty
Low muscle quality and a sedentary lifestyle are indicators for a slow recovery after a total knee arthroplasty (TKA). Mitochondrial function is an important part of muscle quality and a key driver of sarcopenia. However, it is not known whether it relates to recovery. In this pilot study, we monitored activity after TKA using a wrist mounted activity tracker and assessed the relation of mitochondrial function on the rate of recovery after TKA. Additionally, we compared the increase in activity as a way to measure recovery to traditional outcome measures. Patients were studied 2 weeks before TKA and up to 6 months after. Activity was monitored continuously. Baseline mitochondrial function (citrate synthase and complex [CP] 1–5 abundance of the electron transport chain) was determined on muscle tissue taken during TKA. Traditional outcome measures (Knee Injury and Osteoarthritis Outcome Score [KOOS], timed up‐and‐go [TUG] completion time, grip, and quadriceps strength) were performed 2 weeks before, 6 weeks after, and 6 months after TKA. Using a multivariate regression model with various clinical baseline parameters, the following were significantly related to recovery: CP5 abundance, grip strength, and activity (regression weights 0.13, 0.02, and 2.89, respectively). During recovery, activity correlated to the KOOS‐activities of daily living (ADL) score (r = 0.55, p = 0.009) and TUG completion time (r = −0.61, p = 0.001). Mitochondrial function seems to be related to recovery, but so are activity and grip strength, all indicators of sarcopenia. Using activity trackers before and after TKA might give the surgeon valuable information on the expected recovery and the opportunity to intervene if recovery is low.
Postdischarge Recovery after Acute Pediatric Lung Disease Can Be Quantified with Digital Biomarkers
Background: Pediatric patients admitted for acute lung disease are treated and monitored in the hospital, after which full recovery is achieved at home. Many studies report in-hospital recovery, but little is known regarding the time to full recovery after hospital discharge. Technological innovations have led to increased interest in home-monitoring and digital biomarkers. The aim of this study was to describe at-home recovery of 3 common pediatric respiratory diseases using a questionnaire and wearable device. Methods: In this study, patients admitted due to pneumonia (n = 30), preschool wheezing (n = 30), and asthma exacerbation (AE; n = 11) were included. Patients were monitored with a smartwatch and a questionnaire during admission, with a 14-day recovery period and a 10-day “healthy” period. Median compliance was calculated, and a mixed-effects model was fitted for physical activity and heart rate (HR) to describe the recovery period, and the physical activity recovery trajectory was correlated to respiratory symptom scores. Results: Median compliance was 47% (interquartile range [IQR] 33–81%) during the entire study period, 68% (IQR 54–91%) during the recovery period, and 28% (IQR 0–74%) during the healthy period. Patients with pneumonia reached normal physical activity 12 days postdischarge, while subjects with wheezing and AE reached this level after 5 and 6 days, respectively. Estimated mean physical activity was closely correlated with the estimated mean symptom score. HR measured by the smartwatch showed a similar recovery trajectory for subjects with wheezing and asthma, but not for subjects with pneumonia. Conclusions: The digital biomarkers, physical activity, and HR obtained via smartwatch show promise for quantifying postdischarge recovery in a noninvasive manner, which can be useful in pediatric clinical trials and clinical care.
Topical Bimiralisib Shows Meaningful Cutaneous Drug Levels in Healthy Volunteers and Mycosis Fungoides Patients but No Clinical Activity in a First-in-Human, Randomized Controlled Trial
Mycosis fungoides (MF) is a subtype of CTCL with a low incidence and high medical need for novel treatments. The objective of this randomized, placebo-controlled, double-blinded, first-in-human study was to evaluate safety, efficacy, cutaneous and systemic pharmacokinetics (PK) of topical bimiralisib in healthy volunteers (HVs) and MF patients. In this trial, a total of 6 HVs and 19 early-stage MF patients were treated with 2.0% bimiralisib gel and/or placebo. Drug efficacy was assessed by the Composite Assessment of Index Lesion Severity (CAILS) score, supported by objective measuring methods to quantify lesion severity. PK blood samples were collected frequently and cutaneous PK was investigated in skin punch biopsies on the last day of treatment. Local distribution of bimiralisib in HVs showed a mean exposure of 2.54 µg/g in the epidermis. A systemic concentration was observed after application of a target dose of 2 mg/cm2 on 400 cm2, with a mean Cavg of 0.96 ng/mL. Systemic exposure of bimiralisib was reached in all treated MF patients, and normalized plasma concentrations showed a 144% increased exposure compared to HVs, with an observed mean Cavg of 4.49 ng/mL and a mean cutaneous concentration of 5.3 µg/g. No difference in CAILS or objective lesion severity quantification upon 42 days of once-daily treatment was observed in the MF patient group. In general, the treatment was well tolerated in terms of local reactions as well as systemic adverse events. In conclusion, we showed that topical bimiralisib treatment leads to (i) meaningful cutaneous drug levels and (ii) well-tolerated systemic drug exposure in MF patients and (iii) a lack of clinical efficacy, in need of further exploration due to numerous unknown factors, before depreciation of topical bimiralisib as a novel therapeutic drug for CTCLs.
Quantification of tremor using consumer product accelerometry is feasible in patients with essential tremor and Parkinson’s disease: a comparative study
Background To quantify pharmacological effects on tremor in patients with essential tremor (ET) or Parkinson’s Disease (PD), laboratory-grade accelerometers have previously been used. Over the last years, consumer products such as smartphones and smartwatches have been increasingly applied to measure tremor in an easy way. However, it is unknown how the technical performance of these consumer product accelerometers (CPAs) compares to laboratory-grade accelerometers (LGA). This study was performed to compare the technical performance of CPAs with LGA to measure tremor in patients with Parkinson’s Disease (PD) and essential tremor (ET). Methods In ten patients with PD and ten with ET, tremor peak frequency and corresponding amplitude were measured with 7 different CPAs (Apple iPhone 7, Apple iPod Touch 5, Apple watch 2, Huawei Nexus 6P, Huawei watch, mbientlabMetaWear (MW) watch, mbientlab MW clip) and compared to a LGA (Biometrics ACL300) in resting and extended arm position. Results Both in PD and ET patients, the peak frequency of CPAs did not significantly differ from the LGA in terms of limits of agreement. For the amplitude at peak frequency, only the iPhone and MW watch performed comparable to the LGA in ET patients, while in PD patients all methods performed comparable except for the iPod Touch and Huawei Nexus. Amplitude was higher when measured with distally-located CPAs (Clip, iPhone, iPod) compared with proximally-located CPAs (all watches). The variability between subjects was higher than within subjects for frequency (25.1% vs. 13.4%) and amplitude measurement (331% vs. 53.6%). Resting arm position resulted in lower intra-individual variability for frequency and amplitude (13.4 and 53.5%) compared to extended arm position (17.8 and 58.1%). Conclusions Peak frequencies of tremor could be measured with all tested CPAs, with similar performance as LGA. The amplitude measurements appeared to be driven by anatomical location of the device and can therefore not be compared. Our results show that the tested consumer products can be used for tremography, allowing at-home measurements, in particular in studies with a cross-over or intra-individual comparison design using the resting arm position. Trial registration This trial was registered in the Dutch Competent Authority (CCMO) database with number NL60672.058.17 on May 30th 2017.