Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
LanguageLanguage
-
SubjectSubject
-
Item TypeItem Type
-
DisciplineDiscipline
-
YearFrom:-To:
-
More FiltersMore FiltersIs Peer Reviewed
Done
Filters
Reset
91
result(s) for
"631/1647/664/1467"
Sort by:
Digital immunoassay for biomarker concentration quantification using solid-state nanopores
by
Lomovtsev, Dmytro
,
Charron, Martin
,
Tessier, Daniel R.
in
45/71
,
631/1647/664/1467
,
631/57/2282
2021
ABSTRACT
Single-molecule counting is the most accurate and precise method for determining the concentration of a biomarker in solution and is leading to the emergence of digital diagnostic platforms enabling precision medicine. In principle, solid-state nanopores—fully electronic sensors with single-molecule sensitivity—are well suited to the task. Here we present a digital immunoassay scheme capable of reliably quantifying the concentration of a target protein in complex biofluids that overcomes specificity, sensitivity, and consistency challenges associated with the use of solid-state nanopores for protein sensing. This is achieved by employing easily-identifiable DNA nanostructures as proxies for the presence (“1”) or absence (“0”) of the target protein captured via a magnetic bead-based sandwich immunoassay. As a proof-of-concept, we demonstrate quantification of the concentration of thyroid-stimulating hormone from human serum samples down to the high femtomolar range. Further optimization to the method will push sensitivity and dynamic range, allowing for development of precision diagnostic tools compatible with point-of-care format.
The concentration of a biomarker in solution can be determined by counting single molecules. Here the authors report a digital immunoassay scheme with solid-state nanopore readout to quantify a target protein and use this to measure thyroid-stimulating hormone from human serum.
Journal Article
Standardization of ELISA protocols for serosurveys of the SARS-CoV-2 pandemic using clinical and at-home blood sampling
by
Hicks, Jennifer
,
Sadtler, Kaitlyn
,
Gulten, Gulcin
in
49/56
,
631/1647/664/1467
,
631/250/2152/2153/1291
2021
The extent of SARS-CoV-2 infection throughout the United States population is currently unknown. High quality serology is key to avoiding medically costly diagnostic errors, as well as to assuring properly informed public health decisions. Here, we present an optimized ELISA-based serology protocol, from antigen production to data analyses, that helps define thresholds for IgG and IgM seropositivity with high specificities. Validation of this protocol is performed using traditionally collected serum as well as dried blood on mail-in blood sampling kits. Archival (pre-2019) samples are used as negative controls, and convalescent, PCR-diagnosed COVID-19 patient samples serve as positive controls. Using this protocol, minimal cross-reactivity is observed for the spike proteins of MERS, SARS1, OC43 and HKU1 viruses, and no cross reactivity is observed with anti-influenza A H1N1 HAI. Our protocol may thus help provide standardized, population-based data on the extent of SARS-CoV-2 seropositivity, immunity and infection.
Understanding the infection parameters and host responses against SARS-CoV-2 require data from large cohorts using standardized methods. Here, the authors optimize a serum ELISA protocol that has minimal cross-reactivity and flexible sample collection workflow in an attempt to standardize data generation and help inform on COVID-19 pandemic and immunity.
Journal Article
A plug-and-play platform of ratiometric bioluminescent sensors for homogeneous immunoassays
2021
Heterogeneous immunoassays such as ELISA have become indispensable in modern bioanalysis, yet translation into point-of-care assays is hindered by their dependence on external calibration and multiple washing and incubation steps. Here, we introduce RAPPID (Ratiometric Plug-and-Play Immunodiagnostics), a mix-and-measure homogeneous immunoassay platform that combines highly specific antibody-based detection with a ratiometric bioluminescent readout. The concept entails analyte-induced complementation of split NanoLuc luciferase fragments, photoconjugated to an antibody sandwich pair via protein G adapters. Introduction of a calibrator luciferase provides a robust ratiometric signal that allows direct in-sample calibration and quantitative measurements in complex media such as blood plasma. We developed RAPPID sensors that allow low-picomolar detection of several protein biomarkers, anti-drug antibodies, therapeutic antibodies, and both SARS-CoV-2 spike protein and anti-SARS-CoV-2 antibodies. With its easy-to-implement standardized workflow, RAPPID provides an attractive, fast, and low-cost alternative to traditional immunoassays, in an academic setting, in clinical laboratories, and for point-of-care applications.
Many current immunoassays require multiple washing, incubation and optimization steps. Here the authors present Ratiometric Plug-and-Play Immunodiagnostics (RAPPID), a generic assay platform that uses ratiometric bioluminescent detection to allow sandwich immunoassays to be performed directly in solution.
Journal Article
Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye
2012
In resource-constrained countries, affordable methodologies for the detection of disease biomarkers at ultralow concentrations can potentially improve the standard of living
1
,
2
. However, current strategies for ultrasensitive detection often require sophisticated instruments that may not be available in laboratories with fewer resources
3
,
4
,
5
,
6
,
7
,
8
,
9
,
10
,
11
. Here, we circumvent this problem by introducing a signal generation mechanism for biosensing that enables the detection of a few molecules of analyte with the naked eye. The enzyme label of an enzyme-linked immunosorbent assay (ELISA) controls the growth of gold nanoparticles and generates coloured solutions with distinct tonality when the analyte is present. Prostate specific antigen (PSA) and HIV-1 capsid antigen p24 were detected in whole serum at the ultralow concentration of 1 × 10
−18
g ml
−1
. p24 was also detected with the naked eye in the sera of HIV-infected patients showing viral loads undetectable by a gold standard nucleic acid-based test.
A new signal generation mechanism based on the growth of gold nanoparticles offers a way to detect ultralow concentrations of analytes with the naked eye.
Journal Article
Analysis of SARS-CoV-2 antibodies in COVID-19 convalescent blood using a coronavirus antigen microarray
by
Battegay, Manuel
,
Hong, Filbert
,
Stone, Mars
in
631/1647/2017/2065
,
631/1647/664/1467
,
631/61/32
2021
The current practice for diagnosis of COVID-19, based on SARS-CoV-2 PCR testing of pharyngeal or respiratory specimens in a symptomatic patient at high epidemiologic risk, likely underestimates the true prevalence of infection. Serologic methods can more accurately estimate the disease burden by detecting infections missed by the limited testing performed to date. Here, we describe the validation of a coronavirus antigen microarray containing immunologically significant antigens from SARS-CoV-2, in addition to SARS-CoV, MERS-CoV, common human coronavirus strains, and other common respiratory viruses. A comparison of antibody profiles detected on the array from control sera collected prior to the SARS-CoV-2 pandemic versus convalescent blood specimens from virologically confirmed COVID-19 cases demonstrates near complete discrimination of these two groups, with improved performance from use of antigen combinations that include both spike protein and nucleoprotein. This array can be used as a diagnostic tool, as an epidemiologic tool to more accurately estimate the disease burden of COVID-19, and as a research tool to correlate antibody responses with clinical outcomes.
COVID-19 diagnosis is commonly performed by PCR testing, however, serologic methods are more accurate and versatile for monitoring disease burden and epidemiology. Here the authors report a protein microarray with antigens from SARS-CoV-2, SARS-CoV, MERS-CoV as well as common human respiratory viruses.
Journal Article
ELISA detection of SARS-CoV-2 antibodies in saliva
by
MacMullan, Melanie A.
,
Moreno, Jose Ricardo
,
Tran, Frances
in
631/1647/664/1467
,
692/53/2421
,
692/699/255/2514
2020
To facilitate containment of the COVID-19 pandemic currently active in the United States and across the world, options for easy, non-invasive antibody testing are required. Here we have adapted a commercially available, serum-based enzyme-linked immunosorbent assay (ELISA) for use with saliva samples, achieving 84.2% sensitivity and 100% specificity in a set of 149 clinical samples. This strategy will enable widespread, affordable testing for patients who experienced this disease, whilst minimizing exposure risk for healthcare workers.
Journal Article
Single-molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrations
2010
Rissin
et al
. increase the sensitivity of sandwich ELISA by segregating beads bearing a single enzyme-labeled immunoconjugate into femtoliter-volume reaction chambers. As the small volume of each well permits detection of extremely low levels of fluorescence, protein abundance is determined by counting the number of fluorescent wells as a percentage of the number of wells containing beads.
The ability to detect single protein molecules
1
,
2
in blood could accelerate the discovery and use of more sensitive diagnostic biomarkers. To detect low-abundance proteins in blood, we captured them on microscopic beads decorated with specific antibodies and then labeled the immunocomplexes (one or zero labeled target protein molecules per bead) with an enzymatic reporter capable of generating a fluorescent product. After isolating the beads in 50-fl reaction chambers designed to hold only a single bead, we used fluorescence imaging to detect single protein molecules. Our single-molecule enzyme-linked immunosorbent assay (digital ELISA) approach detected as few as ∼10–20 enzyme-labeled complexes in 100 μl of sample (∼10
−19
M) and routinely allowed detection of clinically relevant proteins in serum at concentrations (<10
−15
M) much lower than conventional ELISA
3
,
4
,
5
. Digital ELISA detected prostate-specific antigen (PSA) in sera from patients who had undergone radical prostatectomy at concentrations as low as 14 fg/ml (0.4 fM).
Journal Article
Improved immunoassay sensitivity and specificity using single-molecule colocalization
2022
Enzyme-linked immunosorbent assays (ELISAs) are a cornerstone of modern molecular detection, but the technique still faces notable challenges. One of the biggest problems is discriminating true signal generated by target molecules versus non-specific background. Here, we developed a
Si
ngle-
M
olecule
C
olocalization
A
ssay (SiMCA) that overcomes this problem by employing total internal reflection fluorescence microscopy to quantify target proteins based on the colocalization of fluorescent signal from orthogonally labeled capture and detection antibodies. By specifically counting colocalized signals, we can eliminate the effects of background produced by non-specific binding of detection antibodies. Using TNF-α, we show that SiMCA achieves a three-fold lower limit of detection compared to conventional single-color assays and exhibits consistent performance for assays performed in complex specimens such as serum and blood. Our results help define the pernicious effects of non-specific background in immunoassays and demonstrate the diagnostic gains that can be achieved by eliminating those effects.
A major challenge of enzyme-linked immunosorbent assays is discriminating true signal from non-specific binding. Here the authors present a Single-Molecule Colocalization Assay (SiMCA) which eliminates such effects, enabling reproducible detection of picomolar protein concentrations.
Journal Article
High plasma level of S100A8/S100A9 and S100A12 at admission indicates a higher risk of death in septic shock patients
by
Dubois, Christelle
,
Université Paris-Saclay
,
Marcé, Dominique
in
631/1647/664/1467
,
692/53/2422
,
82/1
2019
Abstract Biomarkers in sepsis for severity, prediction of outcome or reversibility of organ dysfunction are warranted. Measurements of plasma DAMP levels at admission can reflect the severity of cellular damage in septic shock, which might predict the prognosis and reduce the risk of overtreating patients with costly therapies. We measured plasma levels of two DAMPs, S100A8/S100A9 and S100A12 during the first 24 h of admission of septic shock patients. Forty-nine septic shock patients with a similar SOFA scores were selected from our sepsis database to compare a similar proportion of survivors and non-survivors. Plasma levels of S100A8/S100A9 and S100A12 were compared with healthy volunteers using in-house ELISA. Plasma levels of S100A8/S100A9 and S100A12 (5.71 [2.60–13.63] µg/mL and 0.48 [0.22–1.05] µg/mL) were higher in septic shock patients than in healthy volunteers (1.18 [0.74–1.93] µg/mL and 0.09 [0.02–0.39] µg/mL) (P < 0.0001 and P = 0.0030). Levels of S100A8/S100A9 and S100A12 in non-survivors at day 28 (11.70 [2.85–24.36] µg/mL and 0.62 [0.30–1.64] µg/mL) were significantly higher than in survivors (4.59 [2.16–7.47] µg/mL and 0.30 [0.20–0.49] µg/mL) (P = 0.0420 and P = 0.0248) and correlated well (Spearman r = 0.879, P < 0.0001). The high level of plasma calgranulins at admission in septic shock, were higher in non-survivors compared to survivors. These markers could indicate a higher risk of death when SOFA scores are similar and help the stratification of patients for improved care and therapy selection.
Journal Article
A serum “sweet-doughnut” protein facilitates fibrosis evaluation and therapy assessment in patients with viral hepatitis
by
Mizokami, Masashi
,
Hige, Shuhei
,
Ito, Kiyoaki
in
631/1647/2196/2197
,
631/1647/664/1467
,
631/45/221
2013
Although liver fibrosis reflects disease severity in chronic hepatitis patients, there has been no simple and accurate system to evaluate the therapeutic effect based on fibrosis. We developed a glycan-based immunoassay, FastLec-Hepa, to fill this unmet need. FastLec-Hepa automatically detects unique fibrosis-related glyco-alteration in serum hyperglycosylated Mac-2 binding protein within 20 min. The serum FastLec-Hepa counts increased with advancing fibrosis and illustrated significant differences in medians between all fibrosis stages. FastLec-Hepa is sufficiently sensitive and quantitative to evaluate the effects of PEG-interferon-α/ribavirin therapy in a short post-therapeutic interval. The obtained fibrosis progression is equivalent to -0.30 stages/year in patients with sustained virological response and 0.01 stages/year in relapse/nonresponders. Furthermore, long-term follow-up of the severely affected patients found hepatocellular carcinoma developed in patients after therapy whose FastLec-Hepa counts remained above a designated cutoff value. FastLec-Hepa is the only assay currently available for clinically beneficial therapy evaluation through quantitation of disease severity.
Journal Article