Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
803 result(s) for "Agglutination Tests - methods"
Sort by:
A haemagglutination test for rapid detection of antibodies to SARS-CoV-2
Serological detection of antibodies to SARS-CoV-2 is essential for establishing rates of seroconversion in populations, and for seeking evidence for a level of antibody that may be protective against COVID-19 disease. Several high-performance commercial tests have been described, but these require centralised laboratory facilities that are comparatively expensive, and therefore not available universally. Red cell agglutination tests do not require special equipment, are read by eye, have short development times, low cost and can be applied at the Point of Care. Here we describe a quantitative Haemagglutination test (HAT) for the detection of antibodies to the receptor binding domain of the SARS-CoV-2 spike protein. The HAT has a sensitivity of 90% and specificity of 99% for detection of antibodies after a PCR diagnosed infection. We will supply aliquots of the test reagent sufficient for ten thousand test wells free of charge to qualified research groups anywhere in the world. Serological detection of antibodies against SARS-CoV-2 can help establish rates of seroconversion. Here the authors develop a red cell agglutination test to detect antibodies against the receptor binding domain for distribution free of charge to qualified research groups.
Diagnosis of human leptospirosis: systematic review and meta-analysis of the diagnostic accuracy of the Leptospira microscopic agglutination test, PCR targeting Lfb1, and IgM ELISA to Leptospira fainei serovar Hurstbridge
Background Leptospirosis is an underdiagnosed infectious disease with non-specific clinical presentation that requires laboratory confirmation for diagnosis. The serologic reference standard remains the microscopic agglutination test (MAT) on paired serum samples. However, reported estimates of MAT’s sensitivity vary. We evaluated the accuracy of four index tests, MAT on paired samples as well as alternative standards for leptospirosis diagnosis: MAT on single acute-phase samples, polymerase chain reaction (PCR) with the target gene Lfb1 , and ELISA IgM with Leptospira fainei serovar Hurstbridge as an antigen. Methods We performed a systematic review of studies reporting results of leptospirosis diagnostic tests. We searched eight electronic databases and selected studies that tested human blood samples and compared index tests with blood culture and/or PCR and/or MAT (comparator tests). For MAT selection criteria we defined a threshold for single acute-phase samples according to a national classification of leptospirosis endemicity. We used a Bayesian random-effect meta-analysis to estimate the sensitivity and specificity of MAT in single acute-phase and paired samples separately, and assessed risk of bias using the Quality Assessment of Studies of Diagnostic Accuracy Approach- 2 (QUADAS-2) tool. Results For the MAT accuracy evaluation, 15 studies were included, 11 with single acute-phase serum, and 12 with paired sera. Two included studies used PCR targeting the Lfb1 gene, and one included study used IgM ELISA with Leptospira fainei serovar Hurstbridge as antigen. For MAT in single acute-phase samples, the pooled sensitivity and specificity were 14% (95% credible interval [CrI] 3–38%) and 86% (95% CrI 59–96%), respectively, and the predicted sensitivity and specificity were 14% (95% CrI 0–90%) and 86% (95% CrI 9–100%). Among paired MAT samples, the pooled sensitivity and specificity were 68% (95% CrI 32–92%) and 75% (95% CrI 45–93%) respectively, and the predicted sensitivity and specificity were 69% (95% CrI 2–100%) and 75% (2–100%). Conclusions Based on our analysis, the accuracy of MAT in paired samples was not high, but it remains the reference standard until a more accurate diagnostic test is developed. Future studies that include larger numbers of participants with paired samples will improve the certainty of accuracy estimates.
Diagnosis of brucellosis: Combining tests to improve performance
Brucellosis, a zoonotic infectious disease caused by bacteria of the genus Brucella, remains a significant global health concern in many parts of the world. Traditional diagnostic methods, including serological tests, suffer from limitations, including low sensibility and high false-positive rates, emphasizing the need for improved diagnostic strategies. In this study, we aimed to optimize diagnostic accuracy by reevaluating serological tests and exploring novel diagnostic algorithms. A retrospective observational study was conducted using sera collected between June 2012 and June 2023 at the French National Reference Center for Brucella. Various serological tests, including Rose Bengal plate test (RBT), standard agglutination test (SAT), Brucellacapt, and ELISA for IgM and IgG, were performed. Different diagnostic algorithms were evaluated, combining RBT with SAT, Brucellacapt, and ELISA to enhance the performance of diagnostic tests. Among 3587 sera analyzed, 148 were confirmed cases of human brucellosis. Individual serological tests exhibited good sensitivity and specificity but lacked diagnostic accuracy. However, combining RBT with SAT or Brucellacapt significantly improved diagnostic performance, with reduced false positives. The most promising results were observed when an algorithm was built combining RBT, Brucellacapt, and ELISA for IgM and IgG (a score value of 0.5 with 90.5% for sensitivity, 99.7% for specificity, 92.4% for PPV, and 99.6% for NPV). Serological tests remain crucial for brucellosis diagnosis, but their limitations necessitate innovative diagnostic approaches. Combining multiple serological tests in diagnostic algorithms shows promise in improving diagnostic accuracy. Efforts to refine diagnostic, strengthen surveillance, and raise awareness are essential for effective brucellosis control, particularly in resource-limited settings.
Optimizing the microscopic agglutination test (MAT) panel for the diagnosis of Leptospirosis in a low resource, hyper-endemic setting with varied microgeographic variation in reactivity
The microscopic agglutination test (MAT) is the standard serological reference test for the diagnosis of leptospirosis, despite being a technically demanding and laborious procedure. The use of a locally optimised MAT panel is considered essential for proper performance and interpretation of results. This paper describes the procedure of selecting such an optimised panel for Sri Lanka, a country hyper-endemic for leptospirosis. MAT was performed using 24 strains on 1132 serum samples collected from patients presenting with acute undifferentiated fever. Of 24 strains, 15 were selected as the optimised panel, while only 11% of serum samples showed positivity. A geographical variation in predominantly reactive serovars was observed, whereas reactivity was low with the saprophytic strain Patoc. Testing with paired sera yielded a higher sensitivity but provided only a retrospective diagnosis. Serological tests based on ELISA with complementary molecular diagnosis using PCR are a feasible and robust alternative approach to diagnose leptospirosis in countries having a higher burden of the disease.
Diagnosis of Leptospirosis: Comparison between Microscopic Agglutination Test, IgM-ELISA and IgM Rapid Immunochromatography Test
Leptospirosis is diagnosed on clinical grounds, and confirmed by microscopic agglutination test (MAT). IgM-ELISA (Serion-Virion) and immunochromatography test (Leptocheck-WB) are two immunodiagnostic assays for leptospirosis. Their sensitivity, specificity and applicability in Sri Lanka have not been systematically evaluated. Clinically diagnosed leptospirosis patients (n = 919) were recruited from three hospitals in the Western Province of Sri Lanka, during June 2012 to December 2013. MAT, IgM-ELISA and Leptocheck-WB were performed on all patient sera. MAT titer of ≥ 400 in single sample, four-fold rise or seroconversion ≥ 100 in paired samples were considered as positive for MAT. For diagnostic confirmation, MAT was performed during both acute and convalescent phases. Anti-leptospiral IgM ≥ 20 IU/ml and appearance of a band in the test window were considered as positive for IgM-ELISA and Leptocheck-WB test respectively. Patients with an alternative diagnosis (n = 31) were excluded. Data analysis was performed using two methods, i) considering MAT as reference standard and ii) using Bayesian latent class model analysis (BLCM) which considers each test as imperfect. MAT, IgM-ELISA and Leptocheck-WB positivity were 39.8%, 45.8% and 38.7% respectively during the acute phase. Acute-phase MAT had specificity and sensitivity of 95.7% and 55.3% respectively, when compared to overall MAT positivity. IgM-ELISA and Leptocheck-WB had similar diagnostic sensitivity when compared with acute-phase MAT as the gold standard, although IgM-ELISA showed higher specificity (84.5%) than Leptocheck-WB (73.3%). BLCM analysis showed that IgM-ELISA and Leptocheck-WB had similar sensitivities (86.0% and 87.4%), while acute-phase MAT had the lowest sensitivity (77.4%). However, acute-phase MAT had high specificity (97.6%), while IgM-ELISA and Leptocheck-WB showed similar but lower specificity (84.5% and 82.9%). Both IgM-ELISA and Leptocheck-WB shows similar sensitivities and specificities. IgM-ELISA may be superior to MAT during the acute phase and suitable for early diagnosis of leptospirosis. Leptocheck-WB is suitable as a rapid immunodiagnostic screening test for resource limited settings.
Diagnostic method-based underestimation of leptospirosis in clinical and research settings; an experience from a large prospective study in a high endemic setting
Leptospirosis has globally significant human mortality and morbidity, yet estimating the clinical and public health burden of leptospirosis is challenging because timely diagnosis remains limited. The goal of the present study was to evaluate leptospirosis undercounting by current standard methods in both clinical and epidemiological study settings. A prospective hospital-based study was conducted in multiple hospitals in Sri Lanka from 2016 to 2019. Culture, whole blood, and urine samples were collected from clinically suspected leptospirosis cases and patients with undifferentiated fever. Analysis of biological samples from 1,734 subjects confirmed 591 (34.1%) cases as leptospirosis and 297 (17.1%) were classified as \"probable\" leptospirosis cases. Whole blood quantitative PCR (qPCR) did identify the most cases (322/540(60%)) but missed 40%. Cases missed by each method include; urine qPCR, 70% (153/220); acute sample microscopic agglutination test (MAT), 80% (409/510); paired serum sample MAT, 58% (98/170); and surveillance clinical case definition, 53% (265/496). qPCR of negative culture samples after six months of observation was of diagnostic value retrospectively with but missed 58% of positives (109/353). Leptospirosis disease burden estimates should consider the limitations of standard diagnostic tests. qPCR of multiple sample types should be used as a leading standard test for diagnosing acute leptospirosis.
Evaluating the efficacy of serological testing of clinical specimens collected from patients with suspected brucellosis
This study aims to evaluate the efficacy of the standard agglutination test (SAT), the Brucellacapt test and enzyme-linked immunosorbent assay (ELISA) in clinical specimens collected from patients with suspected brucellosis. A prospective study was conducted from December 2020 to December 2021. Brucellosis was diagnosed on the basis of clinical evidence, and confirmed by isolation of Brucella or a four-fold rise in SAT titer. All samples were tested by the SAT, ELISA and the Brucellacapt test. Titers ≥1:100 were considered as SAT positive; ELISA was considered positive when an index greater than 11 was detected, while titers ≥1/160 indicated positivity on the Brucellacapt test. The specificity, sensitivity, and positive (PPVs) and negative predictive values (NPVs) of the three different methods were calculated. A total of 149 samples were collected from patients with suspected brucellosis. The sensitivities for the SAT, IgG, and IgM detection were 74.42%, 88.37% and 74.42%, respectively. The specificities were 95.24%, 93.65%, and 88.89%, respectively. The simultaneous measurement of IgG and IgM improved the sensitivity (98.84%) but reduced the specificity (84.13%) compared to each antibody test separately. The Brucellacapt test had excellent specificity (100%) and a high PPV (100%); however, the sensitivity and NPV were 88.37% and 86.30%, respectively. The combination of IgG detection by ELISA and the Brucellacapt test had excellent diagnostic performance, with 98.84% sensitivity and 93.65% specificity. This study showed that the simultaneous performance of IgG detection by ELISA and the Brucellacapt test has the potential to overcome the current limitations of detection.
Direct agglutination test: Evolution and significance as a simple and safe alternative to tissue aspiration procedures in the diagnosis of visceral leishmaniasis
Although tissue aspiration procedures (TAPs) are considered the gold standard for visceral leishmaniasis (VL) diagnosis, they often fail to detect disease progression before the amastigote-demonstrable phase. To overcome this limitation, a primary direct agglutination test (DAT) was developed using intact Leishmania donovani promastigotes initially treated with trypsin as the antigen. To enhance the exposure of specific epitopes on the promastigote surface and antibody-binding sites, alternative proteolytic agents were evaluated and incorporated into antigen processing and test execution. This approach led to significant or complete inhibition of agglutination in most known cross-reacting disorders. The LQ-DAT consistently demonstrated highly reproducible results across diverse geographical regions, regardless of the L. donovani sub-species or strain. To facilitate routine implementation and local production, the LQ-DAT processing know-how was disseminated to all major VL-endemic areas. Sensitivities comparable to TAP outcomes were demonstrated in 2,224 of 2,697 VL cases successfully diagnosed and treated over 35 years of routine, epidemic, and outbreak evaluations. Notably, 473 (17.5%) of these cases were symptomatic, with TAP-negative but LQ-DAT-positive results, and responded favorably (98.0%−100%) to specific treatment. Given the lower sensitivity also demonstrated by LQ-DAT, TAP does not meet the criteria for classification as the gold-standard VL diagnostic. Consequently, a positive response to specific anti-leishmanial treatment is recommended as a benchmark for diagnostic reliability. Beyond its advantage in detecting VL at earlier stages compared to TAP, the improved LQ-DAT described here also exhibited feasibility and stability required for local production in low-resource settings.
Performance of serological tests available in Brazil for the diagnosis of human visceral leishmaniasis
Visceral leishmaniasis (VL) is the most severe form of leishmaniasis and is potentially fatal if not diagnosed and treated. Accurate and timely diagnosis is considered one of the pillars needed for the reduction in disease-related lethality. Brazil is currently one of the three eco-epidemiological hotspots for this disease. Several serological tests are commercially available in this country for VL diagnosis, although information on the performance of these tests is fragmented and insufficient. The aim of this study was to directly compare the performance of six commercial kits: three enzyme-linked immunosorbent assays (ELISAs), two immunofluorescence antibody tests (IFATs), one immunochromatographic test (ICT), besides one ICT, currently not commercially available in Brazil and one in-house direct agglutination test (DAT-LPC), not yet marketed. A panel of 236 stored samples from patients with clinically suspected VL, including 77 HIV-infected patients, was tested. IT-LEISH and DAT-LPC showed the highest accuracy rate among the non-HIV-infected patients, 96.2% [CI95%: 92.8-99.7%] and 95.6% [CI95%: 91.9-99.3%], respectively. For the ELISA tests evaluated, the maximum accuracy was 91.2%, and in the inter HIV-status group analysis, no significant differences were observed. For both IFATs evaluated, the maximum accuracy was 84.3%, and a lower accuracy rate was observed among the HIV-infected patients (p = 0.039) than among the non-HIV-infected patients. The DAT-LPC was the most accurate test in the HIV-infected patients (p≤0.115). In general, no significant difference in accuracy was observed among the VL-suspected patients stratified by age. In summary, the differences in the performance of the tests available for VL in Brazil confirm the need for local studies before defining the diagnostic strategy.
The diagnostic accuracy of direct agglutination test for serodiagnosis of human visceral leishmaniasis: a systematic review with meta-analysis
Background Direct agglutination test (DAT) as a simple, accurate and reliable method, has been widely used for serodiagnosis of visceral leishmaniasis (VL) during the last three decades. The present study is a systematic review and meta-analysis to evaluate the diagnostic accuracy of DAT for serodiagnosis of human VL. Methods Electronic databases, including MEDLINE (via PubMed), SCOPUS, Web of Science, SID and Mag Iran (two Persian scientific search engines) were searched from December 2004 to April 2019. We determined the pooled sensitivity and specificity rates of DAT for the diagnosis of human VL, calculated positive and negative likelihood ratios (LR+ and LR-), and constructed summary receiver operating characteristic (ROC) curves parameters across the eligible studies. Results Of the 2928 records identified in the mentioned electronic databases and after examining reference lists of articles, 24 articles met inclusion criteria and were enrolled in the systematic review and out of them 20 records qualified for meta-analysis. The pooled sensitivity and specificity rates of DAT was 96% [95% CI, 92–98] and 95% [CI95% 86–99], respectively. The likelihood ratio of a positive test (LR+) was found to be 21 [CI95%, 6.6–66.5] and the likelihood ratio of a negative test (LR−) was found to be 0.04 [(CI95%, 0.02–0.08]. The combined estimate of the diagnostic odds ratio for DAT was high [467 (CI95%, 114–1912]). We found that the summary receiver operating characteristic curve (SROC) is positioned near the upper left corner of the curve and the area under curve (AUC) was 0.98 (95% CI, 0.97 to 0.99). Conclusion Referring to our analysis, we determined that DAT can be considered as a valuable tool for the serodiagnosis of human VL with high sensitivity and specificity. As DAT is a simple, accurate and efficient serological test, it can be recommended for serodiagnosis of human VL particularly in endemic areas.