Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Reading LevelReading Level
-
Content TypeContent Type
-
YearFrom:-To:
-
More FiltersMore FiltersItem TypeIs Full-Text AvailableSubjectPublisherSourceDonorLanguagePlace of PublicationContributorsLocation
Done
Filters
Reset
108
result(s) for
"Air conditioning Design and construction Environmental aspects."
Sort by:
The architecture of natural cooling
\"Overheating in buildings is commonplace. This book describes how we can keep cool without conventional air-conditioning: improving comfort and productivity while reducing energy costs and carbon emissions. It provides architects, engineers and policy makers with a 'how-to' guide to the application of natural cooling in new and existing buildings. It demonstrates, through reference to numerous examples, that natural cooling is viable in most climates around the world. The book includes: Guidance on the principles & strategies that can be adopted. Discussion of how designers integrate natural cooling in their buildings. Explanation of simplified tools for performance assessment. A review of components and controls. A detailed evaluation of building case studies from the USA, Europe, India and China. This book is not just for the technical specialist, as it also provides a general grounding in environmental design. Importantly, it demonstrates that understanding our environment, rather than fighting it, will help us to live sustainably in our rapidly warming world.\" -- Provided by publisher.
A Review on Adaptive Thermal Comfort of Office Building for Energy-Saving Building Design
by
Lamsal, Prativa
,
Bajracharya, Sushil Bahadur
,
Rijal, Hom Bahadur
in
Adaptation
,
adaptive model
,
Air conditioning
2023
The thermal environment quality of office buildings has an important role because thermal comfort is directly related to human productivity. Thermal comfort conditions are influenced by climate, location, and the built environment; hence, comfort standards are required to assist building designers in creating a comfortable indoor environment for building occupants. In this context, the present study analyzes the adaptive thermal comfort studies conducted in office buildings from various countries. A large number of research articles selected from the Scopus database were considered for this study. Based on the analysis, outdoor climatic conditions have a greater influence on indoor thermal conditions in naturally ventilated than in air-conditioned office buildings. The temperature required for comfort is as low as 17.6 °C and as high as 31.2 °C in naturally ventilated buildings. An adaptive comfort equation for naturally ventilated and air-conditioned office buildings has also been proposed to predict the indoor comfort temperature. Various studies show that a substantial amount of energy can be saved by changing the set point and natural ventilation. Furthermore, this study successfully provides hearty evidence that there is a need for climate-specific standards on thermal comfort for energy-efficient design development because existing comfort standards might not be applicable to all climates.
Journal Article
Airflow Dynamics for Micro-Wind Environment Optimization and Human Comfort Improvement: Roadshow Design for Theater Stage Spaces
by
Zhang, Menglong
,
Zhang, Yin
,
Yi, Chang
in
Air conditioning
,
airflow distribution
,
Business metrics
2025
The optimization of ventilation strategies in high-ceiling theater stage spaces is crucial for improving thermal comfort and energy efficiency. This study addresses the challenge of uneven temperature distribution and airflow stagnation in stage environments by employing computational fluid dynamics (CFD) simulations to evaluate the effectiveness of different ventilation modes, including natural, mechanical, and hybrid systems. Six airflow organization scenarios were designed based on modifications to structural layout, equipment settings, and mechanical disturbances (e.g., fan integration). Key evaluation indicators such as temperature uniformity coefficient, airflow velocity, and exhaust efficiency were used to assess performance. The results show that a multi-dimensional optimization approach combining spatial adjustments and mechanical disturbances significantly reduced the average temperature from 26 °C to 23 °C and the temperature uniformity coefficient from 2.79 to 1.49. This study contributes a comprehensive design strategy for stage ventilation that improves comfort while minimizing energy consumption, offering practical implications for performance space design and HVAC system integration.
Journal Article
Optimization of Residential Indoor Thermal Environment by Passive Design and Mechanical Ventilation in Tropical Savanna Climate Zone in Nigeria, Africa
2025
Thermal comfort is a fundamental goal of architecture aiming at protecting individuals from harsh weather conditions. In Nigeria’s savanna climate zone, such as Kaduna, poor indoor thermal comfort leads to over-reliance on air-conditioning systems. There is limited research on the application of passive design strategies in the Nigerian savanna climate, which creates a barrier to their widespread implementation in residential buildings. In response to the increased awareness of climate change and the need for sustainable design, this study explores the potential of passive design strategies, focusing on the combination of rooftop insulation and reflective materials with mechanical ventilation as a means of improving indoor thermal comfort solutions. This study conducted a 3-day field experiment of typical dwellings in Kaduna, a major city in the Nigerian savanna climate zone. The data collected from this experiment served as the basis for a simulation study using EnergyPlus software, which tested and evaluated 3 different strategies: passive design (roof insulation + reflective materials), mechanical ventilation, and a combination of passive design and mechanical ventilation. This study highlights the potential for passive design strategies to provide a more sustainable, cost-effective solution, reducing dependence on air conditioning while supporting indoor comfort. Additionally, the research methodology and insights gained offer a basis for developing future building codes in Nigeria that emphasize sustainable practices. Such codes would guide architects, builders, and policymakers in designing homes that respond to local climate needs and align with broader sustainability goals. Further research could explore additional passive measures, including advanced window technologies, shading, and natural ventilation, to maximize sustainable residential design potential in tropical savanna climates.
Journal Article
Thermal Performance and Optimizing of Composite Trombe Wall with Temperature-Controlled DC Fan in Winter
by
Ma, Qingsong
,
Zhu, Yuewei
,
Fukuda, Hiroatsu
in
Air conditioning
,
Concrete construction
,
Design
2022
This paper discusses an improved approach to the Trombe wall: an insulated panel is installed on the inner side, and vents are installed at the top and bottom to connect the outer and inner air layer with the interior. Direct current (DC) fans are installed in the upper vents for stable control of the air circulation. The study first analyzed the thermal performance of this composite Trombe wall, for which the heat load was 27.3% less compared to the classic Trombe wall and 32.1% less compared to the case without the Trombe wall. However, its efficiency for heating the room temperature was not high without heating. Then, we optimized the ventilation efficiency, the proportion of the Trombe wall in the room, and the type of glazing. The highest heat load savings could be achieved when the ventilation openings used high ventilation with temperature-controlled fans and the Trombe wall about 3% of the house floor area. With the use of Low-e double-glazing, we were able to save nearly 41.3% of the heat load than that with the regular single-glazing. For the composite Trombe wall, after taking into account the optimization factors, the room temperature was significantly higher, and could save nearly 52.3% of energy compared to the pre-optimization period.
Journal Article
Integrated Atmospheric Water Generators for Building Sustainability: A Simulation-Based Approach
by
Magrini, Anna
,
Cattani, Lucia
,
Figoni, Roberto
in
Air conditioning
,
Analysis
,
atmospheric water generators
2025
This paper presents the first results of a broader study aimed at considering atmospheric water generation as a viable option within sustainable building design strategies. In particular, the focus is on integrated systems in which atmospheric water generator (AWG) machines, in addition to producing water, support HVAC systems. The research focuses on the combined use of two different simulation tools: a commercial tool designed to study the energy balance of buildings and a custom-developed software for AWG modelling. This is the first step of a more complex procedure of software integration that is aimed to provide designers with a method to implement AWGs in the design process of buildings, both residential or industrial. This preliminary procedure is applied to a case study concerning the link between an advanced integrated AWG and a building housing inverters and transformers that belong to a photovoltaic field. The scope of the integration consists in enhancing the energy sustainability of atmospheric water intended for hydrogen production and panel washing by means of the dry and cold air flux that comes from the cycle of vapour condensation. The results highlight the potentialities of the integrated design, which includes AWGs, to enhance the final efficiency of sustainable housing. In particular, the joint action of the simulation tools used in this study provides insights about the possibility to reduce the size of traditional chiller that serve the building by an order of magnitude, and to achieve an energy saving of 29.8 MWh a year.
Journal Article
Supporting the Design and Development of Solar Cooling Integrated Façades: A Framework of Decisions, Information, and Stakeholder Involvement
by
Hamida, Hamza
,
Konstantinou, Thaleia
,
Prieto, Alejandro
in
Architecture
,
Climate change
,
Climatic changes
2025
Given the global challenges arising from climate change, relevant, promising methods to expedite the energy transition are essential. The integration of solar cooling technologies into façades represents an important option. Potential benefits of applying solar cooling technologies include conserving primary and conventional electricity sources, lowering peak energy demand to achieve cost savings, and offering environmental benefits. This study aimed to support the design team and stakeholders involved at the design and development stages with a framework that supports developing solar cooling integrated façades. This study adopted a participatory research methodology to identify, outline, and validate key decisions, information, and stakeholders supporting product design and development. The key study findings revealed that the integration of solar cooling technologies into façades should be considered at the conception stage, where the client, climate designer, building physicists, building service consultants, and architects were identified as key participants who should be involved in the decision-making process. The most critical information identified for supporting design decisions includes technology costs, performance and efficiency, cooling demand, and construction characteristics of the thermal envelope.
Journal Article
Performance-Oriented Parametric Optimization Design for Energy Efficiency of Rural Residential Buildings: A Case Study from China’s Hot Summer and Cold Winter Zone
by
Xu, Ying
,
Wu, Yun
,
Shen, Runtian
in
Air conditioning
,
Alternative energy sources
,
Architecture
2024
With the implementation of the rural revitalization strategy, rural residences have become an essential component of China’s building energy conservation efforts. However, most existing research has focused more on urban buildings, with less attention given to rural residences. This study, taking rural residential buildings (RRBs) in the hot summer and cold winter zones in China as an example, proposes a more precise, two-stage optimization design framework using Rhino-Grasshopper for the overall optimization of RRBs. First, field surveys and numerical analysis of collected rural residential design drawings were conducted to clarify spatial characteristics and air conditioning usage. The parametric optimization design of RRBs was then conducted in two steps. The first step involves room function positioning, where spatial geometric models are established. Annual dynamic simulation analyses of AC (air conditioning) and AL (artificial lighting) energy consumption are performed to obtain energy intensity distribution maps. Based on the principle that “space with higher energy consumption is set in the location with lower energy consumption intensity” and the habit of functional space distribution, room function positioning, and adjustments are made. In the second step, the SPEA-2 genetic algorithm was applied for multi-objective optimization of room width, depth, WWR (window-to-wall ratio), SHGC (solar heat gain coefficient), and VLT (visible light transmittance), all based on the logical relationships of the building structure. The final Pareto front solution sets were obtained by multi-objective optimization simulation (MOO). A typical three-bay RRB was selected for application in this study, and the optimized design led to a total energy savings rate of 11% in annual AC and AL energy consumption.
Journal Article
Assessing the Energy and Economic Performance of Green and Cool Roofs: A Life Cycle Approach
by
Scolaro, Taylana Piccinini
,
Ghisi, Enedir
in
Air conditioning
,
Architecture and energy conservation
,
Brazil
2025
Green and cool roofs have significant potential to reduce energy consumption in buildings, but high initial costs and the need for local adaptation limit their adoption. This study aims to compare the life cycle energy assessment (LCEA) and life cycle cost analysis (LCCA) of green, cool, and standard (fibre cement) roofs in three Brazilian cities with different climatic and economic contexts. Computer simulations were carried out on a multifamily residential building model to assess the energy performance of the roofs. The simulation results and literature data were used to estimate the roofs’ energy consumption and cost over the life cycle. Over a 40-year life cycle, green and cool roofs reduced energy consumption by 13% to 22% compared to standard roofs. Cool roofs showed the lowest life cycle costs, while green roofs faced cost-effectiveness challenges due to high initial and maintenance costs. However, in areas with high energy demands and electricity tariffs, the life cycle cost of green roofs may be decreased. The study highlights the crucial role of material selection in embodied energy and emphasises the dominant impact of the operational phase on energy consumption and life cycle costs. These findings underscore the need for customised design strategies and localised assessments to support decision-making.
Journal Article
Assessing Thermal Comfort in Green and Conventional Office Buildings in Hot Climates
by
Khattak, Sanober Hassan
,
Taki, Ahmad
,
Muhammad, Abdulrahman Haruna
in
Air conditioning
,
Certification
,
Climate change
2025
Green buildings are recognised for their potential to reduce energy consumption, minimise environmental impact, and improve occupants’ well-being, benefits that are especially critical in rapidly urbanising regions. However, questions remain about whether these buildings fully meet occupant comfort expectations while delivering energy efficiency. This is particularly relevant in Africa, where climate conditions and energy infrastructure challenges make sustainable building operation essential. Although interest in sustainable construction has increased, limited research has examined the real-world performance of green buildings in Africa. This study helps address that gap by evaluating indoor thermal comfort in a green-certified office building and two conventional office buildings in Abuja, Nigeria, through post-occupancy evaluation (POE). The Predicted Mean Vote (PMV) and Thermal Sensation Vote (TSV) were used to assess comfort, revealing discrepancies between predicted and actual occupant responses. In the green building, PMV indicated near-neutral conditions (0.28), yet occupants reported a slightly cool sensation (TSV: −1.1). Neutral temperature analysis showed that the TSV-based neutral temperature (26.5 °C) was 2.2 °C higher than the operative temperature (24.3 °C), suggesting overcooling. These findings highlight the importance of incorporating occupant feedback into HVAC control. Aligning cooling setpoints with comfort preferences could improve satisfaction and reduce unnecessary cooling, promoting energy-efficient building operation.
Journal Article