Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
3,043 result(s) for "Auditory nerve"
Sort by:
Threshold-distance functions predict speech recognition with cochlear implants
Cochlear implantation shows unexplained outcome variability. Among the key factors affecting outcomes measured by speech understanding is the functional state of the auditory nerve and the amount of its degeneration due to hearing loss. In the present study we actively varied the distance of the stimulating electrodes from the modiolus (the spiral ganglion), quantified it using fluoroscopy and cone-beam computed tomography and related it to electrically-evoked compound action potentials (eCAPs) in human subjects. Stimulation was monopolar. The distance from modiolus could explain up to 91% of the variability in the thresholds of eCAPs. The threshold varied between participants. For individual electrodes of the implant in the given participant, a linear relationship between threshold (in current level) and distance from modiolar axis was found, with different slopes in different participants. The slopes of the eCAP thresholds to modiolus distance of the electrode across ears could explain up to 67% of the variability of speech understanding in these participants. We suggest that the slope of the threshold-distance function might serve as a marker for the functional state of the target neurons (spiral ganglion cells) and can be used to assess this in individual subjects.
Sound exposure dynamically induces dopamine synthesis in cholinergic LOC efferents for feedback to auditory nerve fibers
Lateral olivocochlear (LOC) efferent neurons modulate auditory nerve fiber (ANF) activity using a large repertoire of neurotransmitters, including dopamine (DA) and acetylcholine (ACh). Little is known about how individual neurotransmitter systems are differentially utilized in response to the ever-changing acoustic environment. Here we present quantitative evidence in rodents that the dopaminergic LOC input to ANFs is dynamically regulated according to the animal’s recent acoustic experience. Sound exposure upregulates tyrosine hydroxylase, an enzyme responsible for dopamine synthesis, in cholinergic LOC intrinsic neurons, suggesting that individual LOC neurons might at times co-release ACh and DA. We further demonstrate that dopamine down-regulates ANF firing rates by reducing both the hair cell release rate and the size of synaptic events. Collectively, our results suggest that LOC intrinsic neurons can undergo on-demand neurotransmitter re-specification to re-calibrate ANF activity, adjust the gain at hair cell/ANF synapses, and possibly to protect these synapses from noise damage. Every day, we hear sounds that might be alarming, distracting, intriguing or calming – or simply just too loud. Our hearing system responds to these acoustic changes by fine-tuning sounds before they enter the brain. For example, if a noise is too loud, the volume can be turned down by dampening the signals nerve fibers in the ear send to the brain. This is thought to reduce the damage loud sounds can cause to the sensory organ inside the ear. A set of nerve cells located at the base of the brain called the lateral olivocochlear (LOC) neurons coordinate this adjustment to different volumes and sounds. When these neurons receive information on external sounds, they signal back to the hearing organs and adjust the activity of auditory nerve fibers that communicate this information to the brain. LOC neurons use a diverse range of molecules to modify the activity of auditory nerve fibers, including the ‘feel-good’ neurotransmitter dopamine. But it is unclear what role dopamine plays in this auditory feedback loop. To find out, Wu et al. studied the hearing system of mice that had been exposed to different levels of sound. This involved imaging LOC neurons stained with a marker for dopamine and measuring the activity of nerve fibers in the inner ear. The experiments showed that LOC neurons in mice that had recently been exposed to sound were covered in an enzyme that is essential for making dopamine. The louder the sound, the more of this enzyme was present, suggesting that the amount of dopamine released depends on the volume of the sound. LOC neurons release another neurotransmitter called acetylcholine, which stimulates activity in auditory nerve fibers. Wu et al. found that dopamine and acetylcholine are released from the same group of LOC neurons. However, dopamine had the opposite effect to acetylcholine and reduced nerve activity. These findings suggest that by controlling the mixture of neurotransmitters released, LOC neurons are able to fine-tune the activity of auditory nerve fibers in response to acoustic changes. This work provides a new insight into how our hearing system is able to perceive and relay changes in the sound environment. A better understanding of this auditory feedback loop could influence the design of implant devices for people with impaired hearing.
Development of a non-human primate model for preclinical research of a novel auditory nerve implant
The cochlear implant is a widely available hearing restoration technology that can provide speech understanding in quiet environments. This technology struggles however, in noisy settings or situations involving multiple speakers. The primary cause of these performance limitations is a poor neural interface, in which the bony wall of the cochlea separates the electrode surface from the auditory nerve fibers, thus causing unwanted current spread and non-specific frequency activation. This study utilizes an alternative auditory prosthetic technology (auditory nerve implant, ANI) that enables direct auditory nerve stimulation, which provides a potentially superior neural interface and enables more precise targeting of auditory nerve fibers than traditional cochlear implants. As auditory nerve implants progress towards clinical translation, new implant designs and stimulation strategies will be created. Animal models to efficiently test and iterate through these new designs will be useful for the continued development of ANI technology. We present a viable surgical approach in the non-human primate (rhesus macaque) along with electrophysiological results that demonstrate robust activation of the auditory system at low current levels via intraneural stimulation. Our findings indicate that the rhesus macaque, which possesses an inner ear anatomy more similar to the human compared to other animal models used in the hearing field (e.g., rodents, felines and ferrets), has strong potential as a useful preclinical testbed involving an upright head model for future ANI prototypes and stimulation strategy development.
Investigating the Effect of Cochlear Synaptopathy on Envelope Following Responses Using a Model of the Auditory Nerve
The healthy auditory system enables communication in challenging situations with high levels of background noise. Yet, despite normal sensitivity to pure tones, many listeners complain about having difficulties in such situations. Recent animal studies demonstrated that noise overexposure that produces temporary threshold shifts can cause the loss of auditory nerve (AN) fiber synapses (i.e., cochlear synaptopathy, CS), which appears to predominantly affect medium- and low-spontaneous rate (SR) fibers. In the present study, envelope following response (EFR) magnitude-level functions were recorded in normal hearing (NH) threshold and mildly hearing-impaired (HI) listeners with thresholds elevated above 2 kHz. EFRs were elicited by sinusoidally amplitude modulated (SAM) tones presented in quiet with a carrier frequency of 2 kHz, modulated at 93 Hz, and modulation depths of 0.85 (deep) and 0.25 (shallow). While EFR magnitude-level functions for deeply modulated tones were similar for all listeners, EFR magnitudes for shallowly modulated tones were reduced at medium stimulation levels in some NH threshold listeners and saturated in all HI listeners for the whole level range. A phenomenological model of the AN was used to investigate the extent to which hair-cell dysfunction and/or CS could explain the trends observed in the EFR data. Hair-cell dysfunction alone, including postulated elevated hearing thresholds at extended high frequencies (EHF) beyond 8 kHz, could not account for the recorded EFR data. Postulated CS led to simulations generally consistent with the recorded data, but a loss of all types of AN fibers was required within the model framework. The effects of off-frequency contributions (i.e., away from the characteristic place of the stimulus) and the differential loss of different AN fiber types on EFR magnitude-level functions were analyzed. When using SAM tones in quiet as the stimulus, model simulations suggested that (1) EFRs are dominated by the activity of high-SR fibers at all stimulus intensities, and (2) EFRs at medium-to-high stimulus levels are dominated by off-frequency contributions.
Residual Hair Cell Responses in Electric-Acoustic Stimulation Cochlear Implant Users with Complete Loss of Acoustic Hearing After Implantation
Changes in cochlear implant (CI) design and surgical techniques have enabled the preservation of residual acoustic hearing in the implanted ear. While most Nucleus Hybrid L24 CI users retain significant acoustic hearing years after surgery, 6–17 % experience a complete loss of acoustic hearing (Roland et al. Laryngoscope. 126(1):175-81. (2016), Laryngoscope. 128(8):1939-1945 (2018); Scheperle et al. Hear Res. 350:45-57 (2017)). Electrocochleography (ECoG) enables non-invasive monitoring of peripheral auditory function and may provide insight into the pathophysiology of hearing loss. The ECoG response is evoked using an acoustic stimulus and includes contributions from the hair cells (cochlear microphonic—CM) as well as the auditory nerve (auditory nerve neurophonic—ANN). Seven Hybrid L24 CI users with complete loss of residual hearing months after surgery underwent ECoG measures before and after loss of hearing. While significant reductions in CMs were evident after hearing loss, all participants had measurable CMs despite having no measurable acoustic hearing. None retained measurable ANNs. Given histological data suggesting stable hair cell and neural counts after hearing loss (e.g., Quesnel et al. Hear Res. 333:225-234. (2016)), the loss of ECoG and audiometric hearing may reflect reduced synaptic input. This is consistent with the theory that residual CM responses coupled with little to no ANN responses reflect a “disconnect” between hair cells and auditory nerve fibers (Fontenot et al. Ear Hear. 40(3):577-591. 2019). This “disconnection” may prevent proper encoding of auditory stimulation at higher auditory pathways, leading to a lack of audiometric responses, even in the presence of viable cochlear hair cells.
Otoacoustic emissions but not behavioral measurements predict cochlear nerve frequency tuning in an avian vocal communication specialist
Frequency analysis by the cochlea forms a key foundation for all subsequent auditory processing. Stimulus-frequency otoacoustic emissions (SFOAEs) are a potentially powerful alternative to traditional behavioral experiments for estimating cochlear tuning without invasive testing, as is necessary in humans. Which methods accurately predict cochlear tuning remains controversial due to only a single animal study comparing SFOAE-based, behavioral, and cochlear frequency tuning in the same species. The budgerigar ( Melopsittacus undulatus ) is a parakeet species with human-like behavioral sensitivity to many sounds and the capacity to mimic speech. Intriguingly, previous studies of critical bands, psychophysical tuning curves, and critical ratios in budgerigars show that behavioral tuning sharpness increases dramatically with increasing frequency from 1 to 3.5 kHz, doubling once per octave with peak tuning sharpness from 3.5 to 4 kHz. The pattern contrasts with slower monotonic growth of behavioral tuning sharpness with increasing frequency in other animals, including most avian species, suggesting a possible auditory specialization in budgerigars. We measured SFOAE-based and cochlear-afferent tuning in budgerigars, for comparison to previously reported behavioral results. SFOAE-based and cochlear-afferent tuning sharpness both increased monotonically and relatively slowly for higher frequencies, in contrast to the behavioral pattern. SFOAE-based tuning in budgerigars accurately predicted cochlear frequency tuning, and both measures aligned with typical patterns of cochlear tuning in other species. Divergent behavioral tuning in budgerigars is unlikely attributable to the periphery and could reflect specializations for central processing of masked signals. Our findings highlight the value of SFOAEs for estimating cochlear tuning and caution against direct inference of peripheral tuning from behavioral critical bands, psychophysical tuning curves, and critical ratios.
Simulated auditory nerve response evoked by lateral-wall and peri-modiolar electrode arrays inserted in scala tympani or scala vestibuli
Cochlear implants (CIs) are neuroprosthetic devices designed to restore hearing in individuals with severe to profound hearing loss. Clinically, CI electrode arrays differ by location, either peri-modiolar (pm) positioned near the cochlear axis, or lateral-wall (lw), placed closer to the peripheral terminals of auditory nerve fibers (ANFs). Standard insertion is into the scala tympani (ST), though the scala vestibuli (SV) is considered for cases of severe ST ossification. This computational study investigates the neural responses of both healthy and degenerated ANFs to monopolar stimulation from electrode arrays at different locations. Using a 3D finite element model of the human cochlea, we evaluated threshold excitations for short monophasic pulses across 25 traced ANF pathways. Four array configurations were compared (pmST, pmSV, lwST, lwSV), each with electrodes directly targeting the traced fibers. Results show that excitation thresholds and stimulation specificity depend on both neural health and array position. Specificity, defined by minimizing off-target fiber stimulation, was highest for healthy ANFs with lwSV, followed by pmST, lwST, and pmSV, influenced by electrode orientation. Simulated ST ossification, modeled as decreased conductivity, generally led to reduced cathodic thresholds, suggesting that ST insertion may still be advantageous even with developing or partial ossification. The pmST array consistently offered reliable outcomes across varying electrode configuration and neural conditions. These findings support considering SV insertion when ST is obstructed and highlight factors influencing CI performance based on array location and neural status.
Minimum Detectable Differences in Electrocochleography Measurements: Bayesian-Based Predictions
Physiology of the cochlea and auditory nerve can be assessed with electrocochleography (ECochG), a technique that involves measuring auditory evoked potentials from an electrode placed near or within the cochlea. Research, clinical, and operating room applications of ECochG have in part centered on measuring the auditory nerve compound action potential (AP) amplitude, the summating potential (SP) amplitude, and the ratio of the two (SP/AP). Despite the common use of ECochG, the variability of repeated amplitude measurements for individuals and groups is not well understood. We analyzed ECochG measurements made with a tympanic membrane electrode in a group of younger normal-hearing participants to characterize the within-participant and group-level variability for the AP amplitude, SP amplitude, and SP/AP amplitude ratio. Results show that the measurements have substantial variability and that, especially with smaller sample sizes, significant reduction in variability can be obtained by averaging measurements across repeated electrode placements within subjects. Using a Bayesian-based model of the data, we generated simulated data to predict minimum detectable differences in AP and SP amplitudes for experiments with a given number of participants and repeated measurements. Our findings provide evidence-based recommendations for the design and sample size determination of future experiments using ECochG amplitude measurements, and the evaluation of previous publications in terms of sensitivity to detecting experimental effects on ECochG amplitude measurements. Accounting for the variability of ECochG measurements should result in more consistent results in the clinical and basic assessments of hearing and hearing loss, either hidden or overt.
Electron Microscopic Mapping of Mitochondrial Morphology in the Cochlear Nerve Fibers
To enable nervous system function, neurons are powered in a use-dependent manner by mitochondria undergoing morphological-functional adaptation. In a well-studied model system—the mammalian cochlea, auditory nerve fibers (ANFs) display distinct electrophysiological properties, which is essential for collectively sampling acoustic information of a large dynamic range. How exactly the associated mitochondrial networks are deployed in functionally differentiated ANFs remains scarcely interrogated. Here, we leverage volume electron microscopy and machine-learning-assisted image analysis to phenotype mitochondrial morphology and distribution along ANFs of full-length in the mouse cochlea inner spiral bundle. This reveals greater variance in mitochondrial size with increased ANF habenula to terminal path length. Particularly, we analyzed the ANF terminal-residing mitochondria, which are critical for local calcium uptake during sustained afferent activities. Our results suggest that terminal-specific enrichment of mitochondria, in addition to terminal size and overall mitochondrial abundance of the ANF, correlates with heterogenous mitochondrial contents of the terminal.
Time course and calcium dependence of transmitter release at a single ribbon synapse
At the first synapse in the auditory pathway, the receptor potential of mechanosensory hair cells is converted into a firing pattern in auditory nerve fibers. For the accurate coding of timing and intensity of sound signals, transmitter release at this synapse must occur with the highest precision. To measure directly the transfer characteristics of the hair cell afferent synapse, we implemented simultaneous whole-cell recordings from mammalian inner hair cells (IHCs) and auditory nerve fiber terminals that typically receive input from a single ribbon synapse. During a 1-s IHC depolarization, the synaptic response depressed >90%, representing the main source for adaptation in the auditory nerve. Synaptic depression was slightly affected by α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptor desensitization; however, it was mostly caused by reduced vesicular release. When the transfer function between transmitter release and Ca²⁺ influx was tested at constant open probability for Ca²⁺ channels (potentials >0 mV), a super linear relation was found. This relation is presumed to result from the cooperative binding of three to four Ca²⁺ ions at the Ca²⁺ sensor. However, in the physiological range for receptor potentials (-50 to -30 mV), the relation between Ca²⁺ influx and afferent activity was linear, assuring minimal distortion in the coding of sound intensity. Changes in Ca²⁺ influx caused an increase in release probability, but not in the average size of multivesicular synaptic events. By varying Ca²⁺ buffering in the IHC, we further investigate how Ca²⁺ channel and Ca²⁺ sensor at this synapse might relate.