Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
10,239 result(s) for "Biological Assay - methods"
Sort by:
Maximizing binary interactome mapping with a minimal number of assays
Complementary assays are required to comprehensively map complex biological entities such as genomes, proteomes and interactome networks. However, how various assays can be optimally combined to approach completeness while maintaining high precision often remains unclear. Here, we propose a framework for binary protein-protein interaction (PPI) mapping based on optimally combining assays and/or assay versions to maximize detection of true positive interactions, while avoiding detection of random protein pairs. We have engineered a novel NanoLuc two-hybrid (N2H) system that integrates 12 different versions, differing by protein expression systems and tagging configurations. The resulting union of N2H versions recovers as many PPIs as 10 distinct assays combined. Thus, to further improve PPI mapping, developing alternative versions of existing assays might be as productive as designing completely new assays. Our findings should be applicable to systematic mapping of other biological landscapes. Comprehensive mapping of binary protein-protein interactions requires to combine several complementary assays. Here, the authors show that complete coverage could be reached with a minimal number of assays as long as they explore various experimental conditions.
Stability and Reproducibility Underscore Utility of RT-QuIC for Diagnosis of Creutzfeldt-Jakob Disease
Real-time quaking-induced conversion (RT-QuIC) allows the amplification of miniscule amounts of scrapie prion protein (PrP Sc ). Recent studies applied the RT-QuIC methodology to cerebrospinal fluid (CSF) for diagnosing human prion diseases. However, to date, there has not been a formal multi-centre assessment of the reproducibility, validity and stability of RT-QuIC in this context, an indispensable step for establishment as a diagnostic test in clinical practice. In the present study, we analysed CSF from 110 prion disease patients and 400 control patients using the RT-QuIC method under various conditions. In addition, “blinded” ring trials between different participating sites were performed to estimate reproducibility. Using the previously established cut-off of 10,000 relative fluorescence units (rfu), we obtained a sensitivity of 85 % and a specificity of 99 %. The multi-centre inter-laboratory reproducibility of RT-QuIC revealed a Fleiss’ kappa value of 0.83 (95 % CI: 0.40–1.00) indicating an almost perfect agreement. Moreover, we investigated the impact of short-term CSF storage at different temperatures, long-term storage, repeated freezing and thawing cycles and the contamination of CSF with blood on the RT-QuIC seeding response. Our data indicated that the PrP Sc seed in CSF is stable to any type of storage condition but sensitive to contaminations with blood (>1250 erythrocytes/μL), which results in a false negative RT-QuIC response. Fresh blood-contaminated samples (3 days) can be rescued by removal of erythrocytes. The present study underlines the reproducibility and high stability of RT-QuIC across various CSF storage conditions with a remarkable sensitivity and specificity, suggesting RT-QuIC as an innovative and robust diagnostic method.
Molecular assays for antimalarial drug resistance surveillance: A target product profile
Antimalarial drug resistance is a major constraint for malaria control and elimination efforts. Artemisinin-based combination therapy is now the mainstay for malaria treatment. However, delayed parasite clearance following treatment with artemisinin derivatives has now spread in the Greater Mekong Sub region and may emerge or spread to other malaria endemic regions. This spread is of great concern for malaria control programmes, as no alternatives to artemisinin-based combination therapies are expected to be available in the near future. There is a need to strengthen surveillance systems for early detection and response to the antimalarial drug resistance threat. Current surveillance is mainly done through therapeutic efficacy studies; however these studies are complex and both time- and resource-intensive. For multiple common antimalarials, parasite drug resistance has been correlated with specific genetic mutations, and the molecular markers associated with antimalarial drug resistance offer a simple and powerful tool to monitor the emergence and spread of resistant parasites. Different techniques to analyse molecular markers associated with antimalarial drug resistance are available, each with advantages and disadvantages. However, procedures are not adequately harmonized to facilitate comparisons between sites. Here we describe the target product profiles for tests to analyse molecular markers associated with antimalarial drug resistance, discuss how use of current techniques can be standardised, and identify the requirements for an ideal product that would allow malaria endemic countries to provide useful spatial and temporal information on the spread of resistance.
Key considerations for the experimental training and evaluation of cancer odour detection dogs: lessons learnt from a double-blind, controlled trial of prostate cancer detection
Background Cancer detection using sniffer dogs is a potential technology for clinical use and research. Our study sought to determine whether dogs could be trained to discriminate the odour of urine from men with prostate cancer from controls, using rigorous testing procedures and well-defined samples from a major research hospital. Methods We attempted to train ten dogs by initially rewarding them for finding and indicating individual prostate cancer urine samples (Stage 1). If dogs were successful in Stage 1, we then attempted to train them to discriminate prostate cancer samples from controls (Stage 2). The number of samples used to train each dog varied depending on their individual progress. Overall, 50 unique prostate cancer and 67 controls were collected and used during training. Dogs that passed Stage 2 were tested for their ability to discriminate 15 (Test 1) or 16 (Tests 2 and 3) unfamiliar prostate cancer samples from 45 (Test 1) or 48 (Tests 2 and 3) unfamiliar controls under double-blind conditions. Results Three dogs reached training Stage 2 and two of these learnt to discriminate potentially familiar prostate cancer samples from controls. However, during double-blind tests using new samples the two dogs did not indicate prostate cancer samples more frequently than expected by chance (Dog A sensitivity 0.13, specificity 0.71, Dog B sensitivity 0.25, specificity 0.75). The other dogs did not progress past Stage 1 as they did not have optimal temperaments for the sensitive odour discrimination training. Conclusions Although two dogs appeared to have learnt to select prostate cancer samples during training, they did not generalise on a prostate cancer odour during robust double-blind tests involving new samples. Our study illustrates that these rigorous tests are vital to avoid drawing misleading conclusions about the abilities of dogs to indicate certain odours. Dogs may memorise the individual odours of large numbers of training samples rather than generalise on a common odour. The results do not exclude the possibility that dogs could be trained to detect prostate cancer. We recommend that canine olfactory memory is carefully considered in all future studies and rigorous double-blind methods used to avoid confounding effects.
Metabolomic prediction of endometrial cancer
IntroductionEndometrial cancer (EC) is associated with metabolic disturbances including obesity, diabetes and metabolic syndrome. Identifying metabolite biomarkers for EC detection has a crucial role in reducing morbidity and mortality.ObjectiveTo determine whether metabolomic based biomarkers can detect EC overall and early-stage EC.MethodsWe performed NMR and mass spectrometry based metabolomic analyses of serum in EC cases versus controls. A total of 46 early-stage (FIGO stages I–II) and 10 late-stage (FIGO stages III–IV) EC cases constituted the study group. A total of 60 unaffected control samples were used. Patients and controls were divided randomly into a discovery group (n = 69) and an independent validation group (n = 47). Predictive algorithms based on biomarkers and demographic characteristics were generated using logistic regression analysis.ResultsA total of 181 metabolites were evaluated. Extensive changes in metabolite levels were noted in the EC versus the control group. The combination of C14:2, phosphatidylcholine with acyl-alkyl residue sum C38:1 (PCae C38:1) and 3-hydroxybutyric acid had an area under the receiver operating characteristics curve (AUC) (95% CI) = 0.826 (0.706–0.946) and a sensitivity = 82.6%, and specificity = 70.8% for EC overall. For early EC prediction: BMI, C14:2 and PC ae C40:1 had an AUC (95% CI) = 0.819 (0.689–0.95) and a sensitivity = 72.2% and specificity = 79.2% in the validation group.ConclusionsEC is characterized by significant perturbations in important cellular metabolites. Metabolites accurately detected early-stage EC cases and EC overall which could lead to the development of non-invasive biomarkers for earlier detection of EC and for monitoring disease recurrence.
Clinical utility of a blood-based protein assay to increase screening of elevated-risk patients for colorectal cancer in the primary care setting
Purpose Colorectal cancer (CRC) screening is effective in finding early stage CRC and dramatically improves survival rates. Despite this, the number of eligible patients who do not obtain CRC screening is unacceptably high. Methods We conducted a longitudinal, randomized controlled trial investigating the utility of a blood-based protein assay on the quality of care delivered by practicing PCPs in the United States. We used standardized simulated patients (CPVs), presenting with symptoms suggestive of a higher likelihood of CRC, to measure how frequently these PCPs ordered diagnostic colonoscopy. 190 PCPs cared for three patients at baseline and three patients post-intervention. The PCPs were randomized into one of two study arms: control and intervention. The intervention arm consisted of educational materials about the blood-based protein assay and positive test results. Each simulated patient in the intervention arm had a positive test result that was given to the doctor. The controls were given neither intervention materials nor blood-based protein assay results. Physician responses in both groups were scored against evidence-based criteria. Data were collected at baseline and post-intervention. Results At baseline, we found that 71% of physicians ordered diagnostic colonoscopy. In round 2, 23% of physicians in the intervention arm adopted the new blood-based protein assay. Ordering physicians were 3.88 (95% CI 1.67–9.03) times more likely to order a diagnostic colonoscopy. In percentage terms, those who ordered the assay were more likely to order colonoscopy (92%) than either intervention physicians who did not order the assay (77%) or control physicians (66%) ( p  < 0.001). A marginal effects estimation showed that use of the assay would increase ordering colonoscopy to nearly 95%. Conclusion Over one-third of adults in the United States do not follow the recommended screening guidelines for CRC. The introduction of a blood-based protein assay significantly increased the likelihood that physicians would order diagnostic colonoscopies in elevated-risk patients compared to those without access to the assay results. The overall change in clinical utility observed here has the potential to significantly improve clinical care.
Activities and identification of aryl hydrocarbon receptor agonists in sediments from the Danube river
This study is a consequence of a distinct fish decline in the Danube river since the beginning of the 1990s. In contrast to the decline of fish population, former studies have repeatedly documented that the water quality along the Danube river is improving. However, the conclusion of a pilot study in 2002 was that a high hazard potential is associated with local sediments. The present study documents that sediment samples from the Danube river showed comparatively high aryl hydrocarbon receptor mediated activity in biotests, using the cell lines GPC.2D.Luc, H4IIE (DR-CALUX®) and RTL-W1. The combination of chemical analysis, fractionation techniques and different in vitro tests revealed that priority pollutants could not explain the main induction, even though the concentrations of priority polycyclic aromatic hydrocarbons (PAHs) were very high (maximum in the tributary Schwarzach, sum of 16 EPA PAHs 26 μg/g). In conclusion, this investigation shows that nonpriority pollutants mainly mediate the high induction rates. Nevertheless, owing to the effects of PAHs towards fish and the connection between dioxin-like activity and carcinogenicity, the link between contamination and the fish population decline cannot be ruled out.
Microtiter plate assays to assess antibiofilm activity against bacteria
Bacterial biofilms demonstrate high broad-spectrum adaptive antibiotic resistance and cause two thirds of all infections, but there is a lack of approved antibiofilm agents. Unlike the standard minimal inhibitory concentration assay to assess antibacterial activity against planktonic cells, there is no standardized method to evaluate biofilm inhibition and/or eradication capacity of novel antibiofilm compounds. The protocol described here outlines simple and reproducible methods for assessing the biofilm inhibition and eradication capacities of novel antibiofilm agents against adherent bacterial biofilms grown in 96-well microtiter plates. It employs two inexpensive dyes: crystal violet to stain adhered biofilm biomass and 2,3,5-triphenyl tetrazolium chloride to quantify metabolism of the biofilm cells. The procedure is accessible to any laboratory with a plate reader, requires minimal technical expertise or training and takes 4 or 5 d to complete. Recommendations for how biofilm inhibition and eradication results should be interpreted and presented are also described. This protocol outlines simple and reproducible methods for assessing the biofilm inhibition and eradication capacities of novel antibiofilm agents against adherent bacterial biofilms grown in 96-well microtiter plates.
An overview of apoptosis assays detecting DNA fragmentation
Apoptosis has been recognized as a type of programmed cell death connected with characteristic morphological and biochemical changes in cells. This programmed cell death plays an important role in the genesis of a number of physiological and pathological processes. Thus, it can be very important to detect the signs of apoptosis in a study of cellular metabolism. The present paper provides an overview of methods often being used for detecting DNA fragmentation as one of the most specific findings in apoptosis. To date, three routine assays have been developed for detecting DNA fragmentation: DNA ladder assay, TUNEL assay, and comet assay. All these methods differ in their principles for detecting DNA fragmentation. DNA ladder assay detects the characteristic “DNA ladder” pattern formed during internucleosomal cleavage of DNA. Terminal deoxynUcleotidyl transferase Nick-End Labeling (TUNEL) assay detects DNA strand breaks using terminal deoxynucleotidyl transferase catalyzing attachment of modified deoxynucleotides on the DNA strand breaks. Comet assay can be used for detecting nucleus breakdown producing single/double-strand DNA breaks. The aim of this review is to describe the present knowledge on these three methods, including optimized approaches, techniques, and limitations.
Limitations of the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assay when compared to three commonly used cell enumeration assays
Background The tetrazolium-based MTT assay has long been regarded as the gold standard of cytotoxicity assays as it is highly sensitive and has been miniaturised for use as a high-throughput screening assay. However, various reports refer to interference by different test compounds, including the glycolysis inhibitor 3-bromopyruvate, with the conversion of the dye to coloured formazan crystals. This study assessed the linear range and reproducibility of three commonly used cell enumeration assays; the neutral red uptake (NRU), resazurin reduction (RES) and sulforhodamine B (SRB) assays, in comparison to the MTT assay. Interference between the MTT assay and three glycolysis inhibitors, 2-deoxyglucose, 3-bromopyruvate and lonidamine, was investigated. Results Data indicate that the NRU, RES and SRB assays showed the smallest variability across the linear range, while the largest variation was observed for the MTT assay. This implies that these assays would more accurately detect small changes in cell number than the MTT assay. The SRB assay provided the most reproducible results as indicated by the coefficient of determination after a limited number of experiments. The SRB assay also produced the lowest variance in the derived 50% inhibitory concentration (IC 50 ), while IC 50 concentrations of 3-bromopyruvate could not be detected using either the MTT or RES assays after 24 hours incubation. Interference in the MTT assay was observed for all three tested glycolysis inhibitors in a cell-free environment. No interferences were observed for the NRU, SRB or RES assays. Conclusions This study demonstrated that the MTT assay was not the best assay in a number of parameters that must be considered when a cell enumeration assay is selected: the MTT assay was less accurate in detecting changes in cell number as indicated by the variation observed in the linear range, had the highest variation when the IC 50 concentrations of the glycolysis inhibitors were determined, and interference between the MTT assay and all the glycolysis inhibitors tested were observed. The SRB assay performed best overall considering all of the parameters, suggesting that it is the most suitable assay for use in preclinical screening of novel therapeutic compounds with oxido-reductive potential.