Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
8,208
result(s) for
"Biomechanical study"
Sort by:
Compression analysis of the gray and white matter of the spinal cord
by
Jiang, Fei
,
Suzuki, Hidenori
,
Sakuramoto, Itsuo
in
biomechanical study; cervical spondylotic myelopathy; collapse rate; compression; gray matter; mechanical properties; spinal cord injury; white matter
,
Computer simulation
,
Experiments
2020
The spinal cord is composed of gray matter and white matter. It is well known that the properties of these two tissues differ considerably. Spinal diseases often present with symptoms that are caused by spinal cord compression. Understanding the mechanical properties of gray and white matter would allow us to gain a deep understanding of the injuries caused to the spinal cord and provide information on the pathological changes to these distinct tissues in several disorders. Previous studies have reported on the physical properties of gray and white matter, however, these were focused on longitudinal tension tests. Little is known about the differences between gray and white matter in terms of their response to compression. We therefore performed mechanical compression test of the gray and white matter of spinal cords harvested from cows and analyzed the differences between them in response to compression. We conducted compression testing of gray matter and white matter to detect possible differences in the collapse rate. We found that increased compression (especially more than 50% compression) resulted in more severe injuries to both the gray and white matter. The present results on the mechanical differences between gray and white matter in response to compression will be useful when interpreting findings from medical imaging in patients with spinal conditions.
Journal Article
Initial construct stability of long cephalomedullary nails with superior locking for a complex trochanteric fracture model AO31A2.2– a biomechanical study
2024
Background
Complex fractures of the trochanteric region, as well as fractures located in the directly subtrochanteric region, are controversially discussed around the world regarding the nail type to be used. A long nail is recommended by manufacturers but requires longer surgical and fluoroscopy times. A possible solution could be a nail with an appropriate length which can be locked in a minimally invasive manner by the main aiming device. We aimed to determine if such a nail model (DCN SL nail, SWEMAC, Linköping, Sweden) offers similar structural stability on biomechanical testing on artificial bone as a standard long nail when used to treat complex trochanteric fractures and compared it to long nails usually used in this setting.
Methods
An osteoporotic bone model was chosen. The Swemac Hansson DCN Nail System was used as osteosynthesis material. Two types of nails were chosen: a superior lock nail which can be implanted with a singular targeting device, and a long nail with distal locking using free-hand technique. AO31A2.2 fractures were simulated in a standardised manner. Axial height of the construct, varus collapse, and rotational deformity directly after nail insertion were simulated. A Universal Testing Machine was used. Measurements were made with a stereo-optic tracking system.
Findings
There was a detectable difference in the axial fracture movement resulting in narrowing of the fracture gap. There was no difference in varus collapse or rotational deformity between the nail variants
Conclusion
We conclude that there are small differences which are clinically insignificant and that a superior locking nail can safely be used to manage complex trochanteric fractures.
Journal Article
Endplate weakening during cage bed preparation significantly reduces endplate load capacity
2024
Purpose
To analyze the effect of endplate weakness prior to PLIF or TLIF cage implantation and compare it to the opposite intact endplate of the same vertebral body. In addition, the influence of bone quality on endplate resistance was investigated.
Methods
Twenty-two human lumbar vertebrae were tested in a ramp-to-failure test. One endplate of each vertebral body was tested intact and the other after weakening with a rasp (over an area of 200 mm
2
). Either a TLIF or PLIF cage was then placed and the compression load was applied across the cage until failure of the endplate. Failure was defined as the first local maximum of the force measurement. Bone quality was assessed by determining the Hounsfield units (HU) on CT images.
Results
With an intact endplate and a TLIF cage, the median force to failure was 1276.3N (693.1–1980.6N). Endplate weakening reduced axial endplate resistance to failure by 15% (0–23%). With an intact endplate and a PLIF cage, the median force to failure was 1057.2N (701.2–1735.5N). Endplate weakening reduced axial endplate resistance to failure by 36.6% (7–47.9%). Bone quality correlated linearly with the force at which endplate failure occurred. Intact and weakened endplates showed a strong positive correlation: intact-TLIF: r = 0.964, slope of the regression line (slope) = 11.8,
p
< 0.001; intact-PLIF: r = 0.909, slope = 11.2,
p
= 5.5E−05; weakened-TLIF: r = 0.973, slope = 12.5,
p
< 0.001; weakened-PLIF: r = 0.836, slope = 6,
p
= 0.003.
Conclusion
Weakening of the endplate during cage bed preparation significantly reduces the resistance of the endplate to subsidence to failure: endplate load capacity is reduced by 15% with TLIF and 37% with PLIF. Bone quality correlates with the force at which endplate failure occurs.
Journal Article
Speed whip ripstop technique during anterior cruciate ligament reconstruction using quadriceps tendon results in higher fixation strength
by
Yanatori, Yusuke
,
Kimura, Mitsuhiro
,
Ishida, Yoshihiro
in
Anterior cruciate ligament
,
Biomechanics
,
Configurations
2023
Purpose
To compare the biomechanical strength of different fixation configurations using a suspensory button in a soft-tissue quadriceps tendon graft for Anterior Cruciate Ligament (ACL) reconstruction.
Methods
Thirty fresh-frozen bovine Achilles tendons (10 mm wide, 50 mm long, and 4 mm thick) were used in this study. Tendons were assigned to three groups (
n
= 10 per group) with different suture configurations using adjustable loops with a suspensory button: group A, with the threads of an adjustable loop fixed by crossing at the tip of the loop and the entire loop; group B, continuous loops with hanging buttons were directly sutured to the tendon with eight simple sutures; group C, fixation was performed using the speed whip ripstop technique. Tensile tests with five cycles of preloading were performed at 50 N, held at 50 N for 1 min, and load-to-failure testing was conducted until rupture at 5 mm/min. The difference in the elongation and the maximum load-to-failure force were measured.
Results
The average elongation was significantly larger in group B (16.6 ± 2.2 mm) than in groups A (10.3 ± 2.4 mm) and C (10.0 ± 1.0 mm), (
p
< 0.001). The average load-to-failure force varied significantly between the three groups, 157.5 ± 33.4 N in group A, 253.4 ± 45.5 N in group B, and 337.7 ± 21.0 N in group C, (
p
< 0.001).
Conclusion
Fixation using the speed whip ripstop technique to fix the suspensory button and soft-tissue transplant tendon resulted in minimal elongation and higher fixation strength. Simple devices that use this method have already been developed. Since it can be fixed using a relatively simple method, speed whip ripstop technique was shown to be advantageous for femoral fixation in ACL reconstruction using soft-tissue quadriceps tendon. The findings of this study could help surgeons reduce graft re-tear rates in ACL reconstruction using quadriceps tendons.
Level of evidence
N/A, laboratory control study.
Journal Article
Republication of “A Biomechanical Comparison of Limited Open Versus Krackow Repair for Achilles Tendon Rupture”
2023
Background:
Soft tissue complications after Achilles tendon repair has led to increased interest in less invasive techniques. Various limited open techniques have gained popularity as an alternative to open operative repair. The purpose of this study was to biomechanically compare an open Krackow and limited open repair for Achilles tendon rupture. We hypothesized that there would be no statistical difference in load to failure, work to failure, and initial linear stiffness.
Methods:
A simulated Achilles tendon rupture was created 4 cm proximal to its insertion in 18 fresh-frozen cadaveric below-knee lower limbs. Specimens were randomized to open or limited open PARS Achilles Jig System repair. Repairs were loaded to failure at a rate of 25.4 mm/s to reflect loading during normal ankle range of motion. Load to failure, work to failure, and initial linear stiffness were compared between the 2 repair types.
Results:
The average load to failure (353.8 ± 88.8 N vs 313.3 ± 99.9 N; P = .38) and work to failure (6.4 ± 2.3 J vs 6.3 ± 3.5 J; P = .904) were not statistically different for Krackow and PARS repair, respectively. Mean initial linear stiffness of the Krackow repair (17.8 ± 5.4 N/mm) was significantly greater than PARS repair (11.8 ± 2.5 N/mm) (P = .011).
Conclusion:
No significant difference in repair strength was seen, but higher initial linear stiffness for Krackow repair suggests superior resistance to gap formation, which may occur during postoperative rehabilitation. With equal repair strength, but less soft tissue devitalization, the PARS may be a favorable option for patients with risk factors for soft tissue complications.
Journal Article
Transosseous all-suture anchor fixation for bony Bankart lesions: a biomechanical study
by
Kuan, Fa-Chuan
,
Hsu, Kai-Lan
,
Chang, Wen-Hao
in
All-suture anchor
,
Bankart Lesions - physiopathology
,
Bankart Lesions - surgery
2025
Background
The use of all-suture anchors (ASA) for treating bony Bankart lesions remains challenging because of the limited availability of cortical bone for secure fixation. In this study, the mechanical properties of transosseous ASA fixation, wherein the anchor is placed through the far cortex, were compared with those of metallic suture anchors and standard ASA fixation.
Methods
For this controlled experimental study, 24 suture anchors were inserted into 12 synthetic scapulae with simulated bony Bankart lesions, with two anchors placed in each scapula. The scapulae were randomly assigned to Group A (two 2.7-mm metallic anchors), Group B (two 1.3-mm ASAs secured through standard fixation), or Group C (two 1.3-mm ASAs secured transosseously). For biomechanical analysis, a 5 N preload was applied for 2 min, followed by cyclic loading from 5 to 25 N at 1 Hz for 100 cycles. In addition, a load-to-failure test was conducted at a rate of 60 mm/min. Displacement, stiffness, ultimate failure load, and failure mode were recorded.
Results
There were no significant differences and low correlations in biomechanical properties between the two anchors placed in each scapula. Nor significant intergroup differences were noted in cyclic displacement or linear stiffness. Group C exhibited a significantly higher (
P
< 0.001) ultimate failure load (176.8 ± 32.7 N) than did with Group A (104.4 ± 17.5 N) and Group B (83.0 ± 10.8 N). All failures resulted from anchor pullout, except for two cases in Group C, where deformed suture balls were observed without pullout.
Conclusion
Compared with metallic suture anchors and standard ASA fixation, transosseous ASA fixation significantly improved the maximum failure load in a bony Bankart lesion model, without increasing cyclic displacement.
Level of evidence
Basic Science Study; Biomechanics.
Journal Article
Finite element analysis of biomechanical investigation on diverse internal fixation techniques in oblique lumbar interbody fusion
by
Hu, Xu Qi
,
Lu, Hui Gen
,
Zou, Zhuo Lin
in
Adjacent segment degeneration
,
Advances in minimally invasive orthopedic surgery
,
Analysis
2024
Background
To establish a three-dimensional finite element model of the lumbar spine and investigate the impact of different fixation techniques on the biomechanical characteristics of oblique lumbar interbody fusion (OLIF).
Methods
The study aimed to establish and validate a comprehensive three-dimensional model of the lower lumbar spine (L3-S1) using the finite element method. L4-L5 was selected as the surgical segment, and four distinct OLIF surgical models were constructed: Stand-alone (SA), unilateral cortical bone trajectory screw (UCBT), bilateral cortical bone trajectory screw (BCBT), and bilateral pedicle screw (BPS). The models were underwent a pure moment of 10N·m to simulate lumbar extension, flexion, left bending, right bending, left and right rotation movements. Subsequently, the range of motion (ROM), cage stress, and fixation stress were calculated.
Results
In the L3-L5 segment, the BCBT group showed the most limited range of motion (ROM) under exercise load, indicating superior stability within this group. The ROM and cage stress values were found to be highest in the SA group. In contrast, the cage and internal fixation stress in the BPS group were observed to be lowest (9.91 ~ 53.83MPa, 44.93 ~ 84.85 MPa). With the exception of right bending and right rotation, the UCBT group demonstrated higher levels of internal fixation stress (102.20 ~ 164.62 MPa).
Conclusions
The study found that OLIF-assisted internal fixation improved segmental stability and reduced cage stress. The BPS group had advantages over the CBT group in preventing endplate damage and reducing the risk of cage subsidence. However, BCBT group has distinct merits in maintaining surgical segment stability, distributing stress load on the spinal motor unit, and reducing the likelihood of adjacent segment degeneration (ASD).
Journal Article
The effect of Ding’s screws and tension band wiring for treatment of olecranon fractures: a biomechanical study
2024
Although tension band wiring (TBW) is popular and recommended by the AO group, the high rate of complications such as skin irritation and migration of the K-wires cannot be ignored. Ding’s screw tension band wiring (DSTBW) is a new TBW technique that has shown positive results in the treatment of other fracture types. The objective of this study was to evaluate the stability of DSTBW in the treatment of olecranon fractures by biomechanical testing. We conducted a Synbone biomechanical model by using three fixation methods: DSTBW, intramedullary screw and tension band wiring (IM-TBW), and K-wire TBW, were simulated to fix the olecranon fractures. We compared the mechanical stability of DSTBW, IM-TBW, and TBW in the Mayo Type IIA olecranon fracture Synbone model using a single cycle loading to failure protocol or pullout force. During biomechanical testing, the average fracture gap measurements were recorded at varying flexion angles in three different groups: TBW, IM-TBW, and DSTBW. The TBW group exhibited measurements of 0.982 mm, 0.380 mm, 0.613 mm, and 1.285 mm at flexion angles of 0°, 30°, 60°, and 90° respectively. The IM-TBW group displayed average fracture gap measurements of 0.953 mm, 0.366 mm, 0.588 mm, and 1.240 mm at each of the corresponding flexion angles. The DSTBW group showed average fracture gap measurements of 0.933 mm, 0.358 mm, 0.543 mm, and 1.106 mm at the same flexion angles. No specimen failed in each group during the cyclic loading phase. Compared with the IM-TBW and TBW groups, the DSTBW group showed significant differences in 60° and 90° flexion angles. The mean maximum failure load was 1229.1 ± 110.0 N in the DSTBW group, 990.3 ± 40.7 N in the IM-TBW group, and 833.1 ± 68.7 N in the TBW group. There was significant difference between each groups (
p
< 0.001).The average maximum pullout strength for TBW was measured at 57.6 ± 5.1 N, 480.3 ± 39.5 N for IM-TBW, and 1324.0 ± 43.8 N for DSTBW. The difference between maximum pullout strength of both methods was significant to
p
< 0.0001. DSTBW fixation provides more stability than IM-TBW and TBW fixation models for olecranon fractures.
Journal Article
Lateral locking plate plus antero-posterior lag screws techniques for the management of posterolateral tibial plateau fracture: preliminary clinical results and biomechanical study
2023
IntroductionTo date, there is no consensus on the optimal surgical strategy for the treatment of posterolateral tibial plateau fracture (PLF). This study introduced a novel, simple technique for treating PLF with a lateral locking plate plus antero-posterior lag screws (LPpLS).MethodsWe conducted a retrospective case series of 42 patients (Female/Male 19/23) with PLF treated with LPpLS between 1 July 2016 and 30 June 2019. Several pre- and postoperative outcomes were recorded, including operative time, intraoperative blood loss, CT findings, HSS, and ROM. For biomechanical studies, seventy synthetic tibiae with a simulated posterolateral split fracture were divided into seven groups. The biomechanical evaluation included displacement measurement at axial compression and fatigue testing.ResultsForty-two eligible patients were followed up for an average of 18 months (range 14–21 months). Postoperative radiographs and CT showed good positioning of plates and screws, no fracture fragment loss, and normal articular surfaces in all 42 cases. The biomechanical study showed that the axial stiffness of LPpLS was in the same fashion as the posterior buttress plate and better than the other fixation methods (P < 0.05). Additionally, the LPpLS group had a smaller displacement of fracture fragments along the X-axis (medial to lateral direction) than the BP group (P < 0.01).ConclusionsThe LPpLS technique could implement good reconstruction of the PLF, showing satisfactory therapeutic effect. The biomechanical evaluation demonstrated that the LPpLS had better stability in three-dimensional directions for PLF than other fixation strategies.
Journal Article
The effect of humeral tray thickness on glenohumeral loads in a reverse shoulder ‘smart’ implant
by
Rutigliano, Stella
,
Parsons, Moby
,
Erickson, John
in
Aged
,
Aged, 80 and over
,
Arthroplasty, Replacement, Shoulder - adverse effects
2024
Purpose
The aim of this study was to observe the effects of changing humeral tray thickness on the resultant of intraoperative glenohumeral joint loads using a load-sensing system (LSS).
Methods
An rTSA was performed on fresh frozen full-body cadaver shoulders by using an internal proprietary LSS on the humeral side. The glenohumeral loads (Newtons) and the direction of the resultant force applied on the implant were recorded during four standard positions (External rotation, Extension, Abduction, Flexion) and three “complex” positions of Activity Daily Life (“behind back”, “overhead reach” and “across chest”). For each position, the thickness was increased from 0 to 6 mm in a continuous fashion using the adjustment feature of the humeral system. Each manoeuvre was repeated three times.
Results
All shoulder positions showed a high repeatability of the glenohumeral load magnitude measured with an intra-class correlation coefficient of over 0.9. For each position, we observed a strong but no linear correlation between humeral tray thickness and joint loads. It was a cubical correlation (
r
s
= 0,91) with a short ascending phase, then a plateau phase, and finally a phase with an exponential growth of the loads on the humeral implant. In addition, an increase in trail-poly thickness led to a recentering of force application at the interface of the two glenohumeral implants.
Conclusion
This study provides further insight into the effects of humeral implant thickness on rTSA glenohumeral joint loads during different positions of the arm. Data obtained using this type of device could guide surgeons in finding the proper implant balance during rTSA.
Journal Article