Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
398
result(s) for
"Chromatography, Reverse-Phase - methods"
Sort by:
Greening Reversed-Phase Liquid Chromatography Methods Using Alternative Solvents for Pharmaceutical Analysis
by
Gaudin, Karen
,
Yabré, Moussa
,
Ferey, Ludivine
in
alternative solvents
,
Chromatography
,
Chromatography, High Pressure Liquid - methods
2018
The greening of analytical methods has gained increasing interest in the field of pharmaceutical analysis to reduce environmental impacts and improve the health safety of analysts. Reversed-phase high-performance liquid chromatography (RP-HPLC) is the most widely used analytical technique involved in pharmaceutical drug development and manufacturing, such as the quality control of bulk drugs and pharmaceutical formulations, as well as the analysis of drugs in biological samples. However, RP-HPLC methods commonly use large amounts of organic solvents and generate high quantities of waste to be disposed, leading to some issues in terms of ecological impact and operator safety. In this context, greening HPLC methods is becoming highly desirable. One strategy to reduce the impact of hazardous solvents is to replace classically used organic solvents (i.e., acetonitrile and methanol) with greener ones. So far, ethanol has been the most often used alternative organic solvent. Others strategies have followed, such as the use of totally aqueous mobile phases, micellar liquid chromatography, and ionic liquids. These approaches have been well developed, as they do not require equipment investments and are rather economical. This review describes and critically discusses the recent advances in greening RP-HPLC methods dedicated to pharmaceutical analysis based on the use of alternative solvents.
Journal Article
Lipid Peroxidation Process in Meat and Meat Products: A Comparison Study of Malondialdehyde Determination between Modified 2-Thiobarbituric Acid Spectrophotometric Method and Reverse-Phase High-Performance Liquid Chromatography
2017
The aim of this work was to compare the methods of malondialdehyde detection, as the main secondary product of the lipid peroxidation process, in meat and meat products. Malondialdehyde measurements were performed by two modified methods, the 2-thiobarbituric acid spectrophotometric method and the reverse-phase high-performance liquid chromatography in raw, mechanically-deboned chicken meat and in manufactured frankfurters. The malondialdehyde concentrations measured by the 2-thiobarbituric acid spectrophotometric method were found to be overestimated by more than 25% in raw meat and more than 27% in frankfurters in comparison to the results of reverse-phase high-performance liquid chromatography (p < 0.05). The achieved results showed that the presented modified reverse-phase high-performance liquid chromatography method was more applicable and more accurate for the quantification of malondialdehyde in samples of meat and meat products.
Journal Article
Rapid quantification of fatty acids in plant oils and biological samples by LC-MS
by
Wiebel, Michelle
,
Kampschulte Nadja
,
Koch, Elisabeth
in
Biological properties
,
Biological samples
,
Blood plasma
2021
Analysis of fatty acids (FA) in food and biological samples such as blood is indispensable in modern life sciences. We developed a rapid, sensitive and comprehensive method for the quantification of 41 saturated and unsaturated fatty acids by means of LC-MS. Optimized chromatographic separation of isobaric analytes was carried out on a C8 reversed phase analytical column (100 × 2.1 mm, 2.6 μm core–shell particle) with a total run time of 15 min with back pressure lower than 300 bar. On an old triple quadrupole instrument (3200, AB Sciex), pseudo selected reaction monitoring mode was used for quantification of the poorly fragmenting FA, yielding limits of detection of 5–100 nM. Sample preparation was carried out by removal of phospholipids and triglycerides by solid-phase extraction (non-esterified fatty acids in oils) or saponification in iso-propanol (fatty acyls). This is not only a rapid strategy for quantification of fatty acyls, but allows the direct combination with the LC-MS-based analysis of fatty acid oxidation products (eicosanoids and other oxylipins) from the same sample. The concentrations of fatty acyls determined by means of LC-MS were consistent with those from GC-FID analysis demonstrating the accuracy of the developed method. Moreover, the method shows high precisions with a low intra-day (≤ 10% for almost all fatty acids in plasma and ≤ 15% in oils) and inter-day as well as inter-operator variability (< 20%). The method was successfully applied on human plasma and edible oils. The possibility to quantify non-esterified fatty acids in samples containing an excess of triacylglycerols and phospholipids is a major strength of the described approach allowing to gain new insights in the composition of biological samples.
Journal Article
A guide to large-scale RNA sample preparation
by
Petzold, Katja
,
Karlsson, Hampus
,
Baronti, Lorenzo
in
Biophysics
,
Production methods
,
Purification
2018
RNA is becoming more important as an increasing number of functions, both regulatory and enzymatic, are being discovered on a daily basis. As the RNA boom has just begun, most techniques are still in development and changes occur frequently. To understand RNA functions, revealing the structure of RNA is of utmost importance, which requires sample preparation. We review the latest methods to produce and purify a variation of RNA molecules for different purposes with the main focus on structural biology and biophysics. We present a guide aimed at identifying the most suitable method for your RNA and your biological question and highlighting the advantages of different methods.
Journal Article
Simultaneous Determination of Caffeine and Paracetamol in Commercial Formulations Using Greener Normal-Phase and Reversed-Phase HPTLC Methods: A Contrast of Validation Parameters
by
Ali, Abuzer
,
Aljarba, Tariq M.
,
Alam, Prawez
in
Accuracy
,
Acetaminophen - analysis
,
Acetaminophen - chemistry
2022
There has been no assessment of the greenness of the described analytical techniques for the simultaneous determination (SMD) of caffeine and paracetamol. As a result, in comparison to the greener normal-phase high-performance thin-layer chromatography (HPTLC) technique, this research was conducted to develop a rapid, sensitive, and greener reversed-phase HPTLC approach for the SMD of caffeine and paracetamol in commercial formulations. The greenness of both techniques was calculated using the AGREE method. For the SMD of caffeine and paracetamol, the greener normal-phase and reversed-phase HPTLC methods were linear in the 50–500 ng/band and 25–800 ng/band ranges, respectively. For the SMD of caffeine and paracetamol, the greener reversed-phase HPTLC approach was more sensitive, accurate, precise, and robust than the greener normal-phase HPTLC technique. For the SMD of caffeine paracetamol in commercial PANEXT and SAFEXT tablets, the greener reversed-phase HPTLC technique was superior to the greener normal-phase HPTLC approach. The AGREE scores for the greener normal-phase and reversed-phase HPTLC approaches were estimated as 0.81 and 0.83, respectively, indicated excellent greenness profiles for both analytical approaches. The greener reversed-phase HPTLC approach is judged superior to the greener normal-phase HPTLC approach based on numerous validation parameters and pharmaceutical assays.
Journal Article
Study of Lipophilicity and ADME Properties of 1,9-Diazaphenothiazines with Anticancer Action
2023
Lipophilicity is one of the key properties of a potential drug that determines the solubility, the ability to penetrate through cell barriers, and transport to the molecular target. It affects pharmacokinetic processes such as adsorption, distribution, metabolism, excretion (ADME). The 10-substituted 1,9-diazaphenothiazines show promising if not impressive in vitro anticancer potential, which is associated with the activation of the mitochondrial apoptosis pathway connected with to induction BAX, forming a channel in MOMP and releasing cytochrome c for the activation of caspases 9 and 3. In this publication, the lipophilicity of previously obtained 1,9-diazaphenothiazines was determined theoretically using various computer programs and experimentally using reverse-phase thin-layer chromatography (RP-TLC) and a standard curve. The study presents other physicochemical, pharmacokinetic, and toxicological properties affecting the bioavailability of the test compounds. ADME analysis was determined in silico using the SwissADME server. Molecular targets studies were identified in silico using the SwissTargetPrediction server. Lipinski’s rule of five, Ghose’s, and Veber’s rules were checked for the tested compounds, confirming their bioavailability.
Journal Article
Analytical and preparative separation of phosphorothioated oligonucleotides: columns and ion-pair reagents
2020
Oligonucleotide drugs represent an emerging area in the pharmaceutical industry. Solid-phase synthesis generates many structurally closely related impurities, making efficient separation systems for purification and analysis a key challenge during pharmaceutical drug development. To increase the fundamental understanding of the important preparative separation step, mass-overloaded injections of a fully phosphorothioated 16mer, i.e., deoxythymidine oligonucleotide, were performed on a C18 and a phenyl column. The narrowest elution profiles were obtained using the phenyl column, and the 16mer could be collected with high purity and yield on both columns. The most likely contribution to the successful purification was the quantifiable displacement of the early-eluting shortmers on both columns. In addition, the phenyl column displayed better separation of later-eluting impurities, such as the 17mer impurity. The mass-overloaded injections resulted in classical Langmuirian elution profiles on all columns, provided the concentration of the ion-pairing reagent in the eluent was sufficiently high. Two additional column chemistries, C4 and C8, were also investigated in terms of their selectivity and elution profile characteristics for the separation of 5–20mers fully phosphorothioated deoxythymidine oligonucleotides. When using triethylamine as ion-pairing reagent to separate phosphorothioated oligonucleotides, we observed peak broadening caused by the partial separation of diastereomers, predominantly seen on the C4 and C18 columns. When using the ion-pair reagent tributylamine, to suppress diastereomer separation, the greatest selectivity was found using the phenyl column followed by C18. The present results will be useful when designing and optimizing efficient preparative separations of synthetic oligonucleotides.
Journal Article
Evaluation of lipid quantification accuracy using HILIC and RPLC MS on the example of NIST® SRM® 1950 metabolites in human plasma
2020
Lipidomics analysis for large-scale studies aiming at the identification and quantification of natural lipidomes is often performed using LC–MS-based data acquisition. However, the choice of suitable LC–MS method for accurate lipid quantification remains a matter of debate. Here, we performed the systematic comparison between two HRAM-MS-based quantification workflows based on HILIC and RPLC MS by quantifying 191 lipids from five lipid classes in human blood plasma using deuterated standards in the “one ISTD-per-lipid class” approach. Lipid quantification was performed considering all necessary isotopic corrections, and obtained correction factors are illustrated. Concentrations of lipids in NIST® SRM® 1950 human blood plasma determined by the two methods were comparable for most of the studied lipid species except for highly unsaturated phosphatidylcholines (PC). A comparison of lipid concentrations to consensus values determined in a previously published multi-laboratory study illustrated possible “overestimation” of concentrations for these highly unsaturated lipids by HILIC MS. We evaluated the influence of lipid loading amounts as well as the difference between quantified lipid and internal standard concentrations on the HILIC MS quantification results. We conclude that both HILIC and RPLC HRAM-MS workflows can be equally used for accurate lysophosphatidylcholine (LPC), lysophosphatidylethanolamine (LPE), phosphatidylcholine (PC), phosphatidylethanolamine (PE), and sphingomyelin (SM) lipid quantification, despite significant differences in the concentration of highly unsaturated PC lipids which need to be addressed by establishing response factors to account for the differences in degree of lipid unsaturation.
Journal Article
Development and Validation of an Ion-Pair Reverse-Phase High-Performance Liquid Chromatography–Electrospray Ionization Mass Spectrometry Method for Determination of Purity of Nusinersen for Quality Control of Drug Substance or Drug Product
by
Samoilov, Mikhail
,
Zubareva, Ekaterina
,
Degterev, Maksim
in
Adsorption
,
Chromatography
,
Chromatography, High Pressure Liquid - methods
2026
In this study, an ion-pair reverse-phase high-performance liquid chromatography–electrospray ionization mass spectrometry (RP-HPLC-ESI-MS) method was optimized and validated for purity determination for the quality control of the proposed generic nusinersen oligonucleotide drug substance and drug product. The optimization and considerations of sample preparation, chromatographic and mass spectrometry conditions are discussed. The limit of detection was 2.5 × 10−5 mg/mL and the limit of quantitation was 4.9 × 10−5 mg/mL. The linearity of the signal (XIC) for all impurities was linear with correlation coefficients of R2 ≥ 0.9669. This study, associated with the development of therapeutic oligonucleotides, examines the subject of product-related impurities. The authors consider an ion-pair reverse-phase high-performance liquid chromatography in combination with mass spectrometry for impurity quantitative control. This study contributes to the field by elucidating several critical aspects that, while previously unaddressed in the existing literature, are essential for developing effective analytical methods.
Journal Article
Using prepared mixtures of ToxCast chemicals to evaluate non-targeted analysis (NTA) method performance
by
Williams, Antony J
,
Sobus, Jon R
,
Newton, Seth R
in
Chromatography
,
Contaminants
,
Discordance
2019
Non-targeted analysis (NTA) methods are increasingly used to discover contaminants of emerging concern (CECs), but the extent to which these methods can support exposure and health studies remains to be determined. EPA’s Non-Targeted Analysis Collaborative Trial (ENTACT) was launched in 2016 to address this need. As part of ENTACT, 1269 unique substances from EPA’s ToxCast library were combined to make ten synthetic mixtures, with each mixture containing between 95 and 365 substances. As a participant in the trial, we first performed blinded NTA on each mixture using liquid chromatography (LC) coupled with high-resolution mass spectrometry (HRMS). We then performed an unblinded evaluation to identify limitations of our NTA method. Overall, at least 60% of spiked substances could be observed using selected methods. Discounting spiked isomers, true positive rates from the blinded and unblinded analyses reached a maximum of 46% and 65%, respectively. An overall reproducibility rate of 75% was observed for substances spiked into more than one mixture and observed at least once. Considerable discordance in substance identification was observed when comparing a subset of our results derived from two separate reversed-phase chromatography methods. We conclude that a single NTA method, even when optimized, can likely characterize only a subset of ToxCast substances (and, by extension, other CECs). Rigorous quality control and self-evaluation practices should be required of labs generating NTA data to support exposure and health studies. Accurate and transparent communication of performance results will best enable meaningful interpretations and defensible use of NTA data.
Journal Article