Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
1,776 result(s) for "Chromium - blood"
Sort by:
The John Charnley Award: Metal-on-Metal Hip Resurfacing versus Large-diameter Head Metal-on-Metal Total Hip Arthroplasty: A Randomized Clinical Trial
Resurfacing arthroplasty has become an attractive option for young patients who want to maintain a high activity level. One recent study reported modestly increased activity levels for patients with resurfacing compared to standard total hip arthroplasty (THA). We conducted a prospective randomized clinical trial to compare clinical outcomes of resurfacing versus large-head metal-on-metal total hip arthroplasty. We randomized 107 patients deemed eligible for resurfacing arthroplasty to have either resurfacing or standard THA. Patients were assessed for quality-of-life outcomes using the PAT-5D index, WOMAC, SF-36, and UCLA activity score. The minimum followup was 0.8 years (mean, 1.1 years; range, 0.8–2.2 years). Of the 73 patients followed at least one year, both groups reported improvement in quality of life on all outcome measures. There was no difference in quality of life between the two arms in the study. Serum levels of cobalt and chromium were measured in a subset of 30 patients. In both groups cobalt and chromium was elevated compared to baseline. Patients receiving a large-head metal-on-metal total hip had elevated ion levels compared to the resurfacing arm of the study. At 1 year, the median serum cobalt increased 46-fold from baseline in patients in the large-head total hip group, while the median serum chromium increased 10-fold. At 1 year, serum cobalt was 10-fold higher and serum chromium 2.6-fold higher than in the resurfacing arm. Due to these excessively high metal ion levels, the authors recommend against further use of this particular large-head total hip arthroplasty. Level of Evidence: Level I, randomized clinical trial. See Guidelines for Authors for a complete description of levels of evidence.
Controlling type-2 diabetes by inclusion of Cr-enriched yeast bread in the daily dietary pattern: a randomized clinical trial
PurposeChromium (Cr)-enriched yeast supplementation to whole wheat bread (WWCrB) has been shown to ameliorate postprandial glycemic response in healthy subjects. The present study investigates the long-term benefit of WWCrB consumption for patients with type-2 diabetes mellitus (T2DM).MethodsThirty patients with T2DM were randomly assigned to a group receiving WWCrB or the plain whole wheat bread (WWB) group. Plasma glucose, insulin, glycosylated hemoglobin (HbA1c) and insulin resistance were determined, and oral glucose tolerance test (OGTT) was performed at the beginning and the end of the dietary intervention, which lasted for 12 weeks. Biochemical parameters related to the disease, markers of inflammation as well as body weight and energy balance were examined.ResultsAt the end of the study, subjects of WWCrB group exerted lower levels of glucose, insulin and HbA1c and improved insulin resistance (P < 0.05 against before treatment). Area under the glucose curve attained during OGTT decreased after the intervention (28,117.5 ± 1266.4 vs. 31,588.5 ± 1187.5 mg min/dL before treatment, P < 0.05) with significantly lower values of glucose concentration at 0 and 60 min. A significant reduction in body weight and systolic blood pressure (SBP) was observed (P < 0.05 against before treatment). Markers of inflammation and lipid profiles were not affected by WWCrB consumption.ConclusionsInclusion of WWCrB in the daily dietary pattern of diabetic patients resulted in improvement of glucose tolerance and insulin resistance, significant reduction in HbA1c, weight loss and lower SBP. Patients with inadequate glycemic control may benefit from the consumption of WWCrB.
Similar outcome during short-term follow-up after coated and uncoated total knee arthroplasty: a randomized controlled study
Purpose Patients with known hypersensitivity to metals often require hypoallergenic TKA implants. Coating of a standard implant is a common solution, and although in vitro tests have demonstrated reduction of polyethylene wear for these coatings, it is still unknown whether these implants have any clinical benefit. This study was initiated to investigate metal ion concentrations, knee function and patient-reported outcome (PRO) after coated and uncoated TKA. Methods One hundred and twenty-two (122) patients were randomized to receive a coated or a standard TKA and, after exclusions, 59 patients were included in each group. Knee function and PRO were assessed with validated scores up to 3 years after surgery. Metal ion concentrations in blood samples were determined for chromium, cobalt, molybdenum and nickel, preoperatively and 1 year after surgery. Results Chromium concentrations in patient plasma increased from a median of 0.25 to 1.30 µg/l in the standard TKA group, and from 0.25 to 0.75 µg/l in the coated TKA group ( p  = 0.012). Thirteen patients (3 coated, 10 standard TKA) had chromium concentrations above 2 µg/l. The concentrations of cobalt, molybdenum and nickel did not change. Patient-reported outcome measures (PROM) demonstrated a substantial improvement after TKA, without any differences between the groups. Conclusion The increase in chromium concentration in the standard group needs further investigation. If surgeons use coated implants, they can be confident that these implants perform as well as standard implants. Level of evidence I.
Chromium in Drinking Water: Association with Biomarkers of Exposure and Effect
An epidemiological cross-sectional study was conducted in Greece to investigate health outcomes associated with long-term exposure to chromium via drinking water. The study population consisted of 304 participants. Socio-demographics, lifestyle, drinking water intake, dietary habits, occupational and medical history data were recorded through a personal interview. Physical examination and a motor test were carried out on the individuals. Total chromium concentrations were measured in blood and hair of the study subjects. Hematological, biochemical and inflammatory parameters were determined in blood. Chromium in drinking water ranged from <0.5 to 90 μg·L−1 in all samples but one (220 μg·L−1), with a median concentration of 21.2 μg·L−1. Chromium levels in blood (median 0.32 μg·L−1, range <0.18–0.92 μg·L−1) and hair (median 0.22 μg·g−1, range 0.03–1.26 μg·g−1) were found within “normal range” according to the literature. Personal lifetime chromium exposure dose via drinking water, calculated from the results of the water analyses and the questionnaire data, showed associations with blood and hair chromium levels and certain hematological and biochemical parameters. Groups of subjects whose hematological or biochemical parameters were outside the normal range were not correlated with chromium exposure dose, except for groups of subjects with high triglycerides or low sodium. Motor impairment score was not associated with exposure to chromium.
Inorganic Vanadium Supplementation in Crossbred Calves: Effects on Antioxidant Status, Immune Response and Haemato-Biochemical Attributes
The aim of the study was to assess the effect of inorganic vanadium (V) supplementation on antioxidant enzymes, immune status, and haemato-biochemical attributes of growing crossbred calves. Twenty-four male Karan Fries calves (Tharparkar × Holstein Friesian) (initial body mass 72.83 ± 2.5 kg; age 3–9 month) were randomly allocated to four groups: the control (received basal diet devoid of supplemental V), the 3 ppm (received basal diet with 3 mg/kg V), the 6 ppm (received basal diet with 6 mg/kg V) and the 9 ppm group (received basal diet with 9 mg/kg V). All the calves were fed for 150 days as per ICAR (2013) feeding standards to meet their nutrient requirements for 500 g growth rate/day. Peripheral blood samples were collected at the start of experiment and subsequently at 30, 60, 90, 120 and 150 days post-V supplementation for determination of antioxidant enzyme activity, immunological parameters and haemato-biochemical attributes. Results indicated that dietary supplementation of V did not affect daily gain, feed intake and haematological parameters. Crossbred calves fed with 9 mg V/kg diet showed reduced (P < 0.05) plasma total cholesterol concentration; however, plasma total protein and glucose concentration remained unaltered. Glutathione peroxidase (GPx) activity as well as immunoglobulin G (IgG) concentration was significantly (P < 0.05) higher in group supplemented with 9 mg V/kg DM; however, superoxide dismutase (SOD), catalase activity and total plasma immunoglobulin (Ig) concentration were similar in all experimental group. Dietary V supplementation showed a negative relation with plasma thiobarbituric acid reactive substances (TBARS) concentration, whereas non-esterified fatty acid (NEFA) concentration remained unaltered among all groups. Plasma V level increased (P < 0.05) with increasing dietary V levels without affecting levels of Ca, Mg, Fe, Cu and Zn. In conclusion, a dietary addition of 9 mg V/kg DM reduced cholesterol content and improved antioxidant and immune response in growing crossbred calves.
Metal hypersensitivity and metal ion levels in patients with coated or uncoated total knee arthroplasty: a randomised controlled study
Purpose Metal ion release by orthopaedic implants may cause local and systemic effects and induce hypersensitivity reactions. Coated implants have been developed to prevent or reduce these effects. This study was initiated to investigate the safety of a novel coating for total knee arthroplasty (TKA) implants. Methods A total of 120 patients undergoing primary TKA with no history of hypersensitivity and no other metal implant were randomised to receive either a coated or uncoated implant. Chromium (Cr), cobalt (Co), molybdenum (Mb) and nickel (Ni) hypersensitivity patch testing and plasma ion concentrations were evaluated pre-operatively and one year post-operatively. Results At the one year follow-up both groups demonstrated significant improvement in knee function and quality of life. One new weakly positive reaction to Co in the TKA group with coated implant and two doubtful skin reactions to Ni (one in each group) were noted. Even with sensitisation to implant materials no skin reactions were observed. Plasma metal ion concentrations did not increase and were not elevated at the one year follow-up in either group. Conclusions Sensitisation after TKA was rare and had no influence on clinical results. TKA with coated implant and standard TKA demonstrated no plasma metal ion elevation.
2008 John Charnley Award: Metal Ion Levels After Metal-on-Metal Total Hip Arthroplasty: A Randomized Trial
Metal-on-metal bearing total hip arthroplasty is performed more commonly than in the past. There may be manufacturing differences such as clearance, roughness, metallurgy, and head size that affect performance. In a prospective, randomized trial, we compared 2-year postoperative ion levels for a 28-mm metal-on-polyethylene bearing with 28-mm and 36-mm metal-on-metal bearings. We measured serum, erythrocyte, and urine ion levels. We observed no difference in the ion levels for the 28-mm and 36-mm metal-on-metal bearings. The ion levels in these patients were lower than reported for most other metal-on-metal bearings. Although both erythrocyte and serum cobalt increased, erythrocyte chromium and erythrocyte titanium did not increase despite a four- to sixfold serum chromium and a three- to fourfold serum titanium increase. This may represent a threshold level for serum chromium and serum titanium below which erythrocytes are not affected. Level of Evidence: Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Is the Pharmacological Mode of Action of Chromium(III) as a Second Messenger?
Although recent studies have shown that chromium (as the trivalent ion) is not an essential trace element, it has been demonstrated to generate beneficial effects at pharmacologically relevant doses on insulin sensitivity and cholesterol levels of rodent models of insulin insensitivity, including models of type 2 diabetes. The mode of action of Cr(III) at a molecular level is still an area of active debate; however, the movement of Cr(III) in the body, particularly in response to changes in insulin concentration, suggests that Cr(III) could act as a second messenger, amplifying insulin signaling. The evidence for the pharmacological mechanism of Cr(III)’s ability to increase insulin sensitivity by acting as a second messenger is reviewed, and proposals for testing this hypothesis are described.
Effects of Chromium Brewer’s Yeast Supplementation on Body Mass, Blood Carbohydrates, and Lipids and Minerals in Type 2 Diabetic Patients
Chromium(III) is considered as an essential element for carbohydrate and lipid metabolism. The aim of this clinical study was to evaluate the efficacy of Cr brewer’s yeast supplementation on body mass, carbohydrate, lipids and mineral indices in type 2 diabetic patients. Twenty adult type 2 diabetic subjects (11 males and 9 females aged 37–63) were supplemented with Cr brewer’s yeast in dosages of 500 μg Cr/person/day or placebo for 8 weeks in a double-blind, placebo-controlled crossover design. It was found that supplemental Cr did not affect body mass, blood lipid profile, resistin levels, and the serum and hair Zn, Fe, and Cu levels, but increased serum Cr (by 116%) and hair Cr (by 20.6%) concentrations and improved some blood carbohydrate indices (significant increase in the β cell function index by 18.8%) in type 2 diabetic patients. In conclusion, Cr brewer’s yeast has a weak hypoglycemic potential, but does not affect body mass, blood biochemical profile, and microelement levels in type 2 diabetic subjects.
No Difference in Reoperations at 2 Years Between Ceramic-on-metal and Metal-on-metal THA: A Randomized Trial
Background Hard-on-hard bearings for total hip arthroplasty continue to warrant analysis even though crosslinked polyethylene is performing very well. Ceramic-on-metal (CoM) has low in vitro wear and did well in an early clinical trial. We report on a prospective, randomized, multicenter investigational device trial comparing CoM with metal-on-metal (MoM). Questions/purposes (1) Is there a difference in the number or type of revisions comparing CoM with MoM? (2) Are cobalt and chromium metal levels different for CoM and MoM THA? Methods Between August 2005 and October 2006, of 1015 patients screened, 390 patients were enrolled at 11 centers and randomized to 194 CoM and 196 MoM bearings. There was no difference in the preoperative patient demographics between the study groups. Mean followup was 50 months (range, 22–75 months). Seventy-two patients from two centers had metal level analysis. Results With the numbers available, there was no difference in the proportion of patients undergoing revisions between the MoM and the CoM cohorts (MOM: 3% [six of 196]; COM: 1.5% [three of 194]; p = 0.50). Four MoM revisions were unrelated to the bearing surface. Two had bearing surface-related reoperations, one for an aseptic lymphocyte-dominated vasculitis-associated lesion and one for elevated metal levels with acetabular malposition. None of the CoM revisions were related to the bearing surface. The metal level analysis revealed that in contrast to the CoM, the MoM bearing group had increasing values of erythrocyte and serum cobalt from 1 to 5 years (CoM erythrocyte 0.45–0.55 ppb, p = 0.11 and CoM serum 0.88–0.85, p = 0.55, and MoM erythrocyte 0.32–0.51 ppb, p < 0.01 and MoM serum 0.65–1.01 ppb, p < 0.01). In addition, the MoM cobalt levels in erythrocytes and serum at 5 years were more variable than at 1 year (erythrocyte interquartile range [IQR], 0.26–0.44 to 0.31–1.21 ppb and serum IQR, 0.42–0.80 to 0.64–2.20 ppb, p < 0.02 for both). Conclusions Although both bearings performed well at short-term followup, the CoM bearing group had no wear-related revisions and maintained consistently low metal levels. The MoM cobalt elevations may be important considering recent reports of taper corrosion. This CoM bearing was approved by the FDA but withdrawn from the market because of low sales. If it were available, the authors would not use CoM until long-term data were available. The bearing would have to outperform crosslinked polyethylene because it is unlikely that CoM metal levels will return to normal. Level of Evidence Level I, therapeutic study.