Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
LanguageLanguage
-
SubjectSubject
-
Item TypeItem Type
-
DisciplineDiscipline
-
YearFrom:-To:
-
More FiltersMore FiltersIs Peer Reviewed
Done
Filters
Reset
788
result(s) for
"Disinfection - statistics "
Sort by:
Chlorhexidine plus alcohol versus povidone iodine plus alcohol, combined or not with innovative devices, for prevention of short-term peripheral venous catheter infection and failure (CLEAN 3 study): an investigator-initiated, open-label, single centre, randomised-controlled, two-by-two factorial trial
2021
Two billion peripheral venous catheters are sold globally each year, but the optimal skin disinfection and types of devices are not well established. We aimed to show the superiority of disinfection with 2% chlorhexidine plus alcohol over 5% povidone iodine plus alcohol in preventing infectious complications, and of closed integrated catheters, positive displacement needleless-connectors, disinfecting caps, and single-use prefilled flush syringes used in combination (innovation group) over open catheters and three-way stopcocks for treatment administration (standard group) in preventing catheter failure.
We did an open-label, randomised-controlled trial with a two-by-two factorial design, for which we enrolled adults (age ≥18 years) visiting the emergency department at the Poitiers University Hospital, France, and requiring one peripheral venous catheter before admission to the medical wards. Before catheter insertion, patients were randomly assigned (1:1:1:1) using a secure web-based random-number generator to one of four treatment groups based on skin preparation and type of devices (innovative devices or standard devices; 2% chlorhexidine plus alcohol or 5% povidone iodine plus alcohol). Primary outcomes were the incidence of infectious complications (local infection, catheter colonisation, or bloodstream infections) and time between catheter insertion and catheter failure (occlusion, dislodgment, infiltration, phlebitis, or infection). This study is registered with ClinicalTrials.gov, NCT03757143.
1000 patients were recruited between Jan 7, and Sept 6, 2019, of whom 500 were assigned to the chlorhexidine plus alcohol group and 500 to the povidone iodine plus alcohol group (250 with innovative solutions and 250 with standard devices in each antiseptic group). No significant interaction was found between the two study interventions. Local infections occurred less frequently with chlorhexidine plus alcohol than with povidone iodine plus alcohol (0 [0%] of 496 patients vs six [1%] of 493 patients) and the same was observed for catheter colonisation (4/431 [1%] vs 70/415 [17%] catheters among the catheters cultured; adjusted subdistribution hazard ratio 0·08 [95% CI 0·02–0·18]). Median time between catheter insertion and catheter failure was longer in the innovation group compared with the standard group (50·4 [IQR 29·6–69·4] h vs 30·0 [16·6–52·6] h; p=0·0017). Minor skin reactions occurred in nine (2%) patients in the chlorhexidine plus alcohol group and seven (1%) patients in the povidone iodine plus alcohol group.
For skin antisepsis, chlorhexidine plus alcohol provides greater protection of peripheral venous catheter-related infectious complications than does povidone iodine plus alcohol. Use of innovative devices extends the catheter complication-free dwell time.
Becton Dickinson.
Journal Article
Cannula and circuit management in peripheral extracorporeal membrane oxygenation: An international survey of 45 countries
2019
Effective and safe practices during extracorporeal membrane oxygenation (ECMO) including infection precautions and securement of lines (cannulas and circuits) are critical to prevent life-threatening patient complications, yet little is known about the practices of bedside clinicians and data to support best practice is lacking. Therefore, the aim of this study was to identify and describe common line-related practices for patients supported by peripheral ECMO worldwide and to highlight any gaps for further investigation. An electronic survey was conducted to examine common line practices for patients managed on peripheral ECMO. Responses were obtained from 45 countries with the majority from the United States (n = 181) and United Kingdom (n = 32). Standardised infection precautions including hand hygiene, maximal barrier precautions and skin antisepsis were commonplace for cannulation. The most common antisepsis strategies included alcohol-based chlorhexidine gluconate (CHG) for cannula insertion (53%) and maintenance (54%), isopropyl alcohol on circuit access ports (39%), and CHG-impregnated dressings to cover insertion sites (36%). Adverse patient events due to line malposition or dislodgement were reported by 34% of respondents with most attributable to ineffective securement. Centres 'always' suturing peripheral cannula sites were more likely to experience a cannula adverse event than centres that 'never' sutured (35% [95% CI 30, 41] vs 0% [95% CI 0, 28]; Chi-square 4.40; p = 0.04) but this did not meet the a priori significance level of <0.01. An evidence-based guideline would be beneficial to improve ECMO line management according to 78% of respondents. Evidence gaps were identified for antiseptic agents, dressing products and regimens, securement methods, and needleless valves. Future research addressing these areas may provide opportunities for consensus guideline development and practice improvement.
Journal Article
Contamination and washing of cloth masks and risk of infection among hospital health workers in Vietnam: a post hoc analysis of a randomised controlled trial
by
Dung, Tham Chi
,
Seale, Holly
,
Rahman, Bayzidur
in
Adult
,
Betacoronavirus
,
Coronavirus Infections - epidemiology
2020
BackgroundIn a previous randomised controlled trial (RCT) in hospital healthcare workers (HCWs), cloth masks resulted in a higher risk of respiratory infections compared with medical masks. This was the only published RCT of cloth masks at the time of the COVID-19 pandemic.ObjectiveTo do a post hoc analysis of unpublished data on mask washing and mask contamination from the original RCT to further understand poor performance of the two-layered cotton cloth mask used by HCWs in that RCT.Setting14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam.ParticipantsA subgroup of 607 HCWs aged ≥18 years working full time in selected high-risk wards, who used a two-layered cloth mask and were part of a randomised controlled clinical trial comparing medical masks and cloth masks.InterventionWashing method for cloth masks (self-washing or hospital laundry). A substudy of contamination of a sample of 15 cloth and medical masks was also conducted.Outcome measureInfection rate over 4 weeks of follow up and viral contamination of masks tested by multiplex PCR.ResultsViral contamination with rhinovirus was identified on both used medical and cloth masks. Most HCW (77% of daily washing) self-washed their masks by hand. The risk of infection was more than double among HCW self-washing their masks compared with the hospital laundry (HR 2.04 (95% CI 1.03 to 4.00); p=0.04). There was no significant difference in infection between HCW who wore cloth masks washed in the hospital laundry compared with medical masks (p=0.5).ConclusionsUsing self-reported method of washing, we showed double the risk of infection with seasonal respiratory viruses if masks were self-washed by hand by HCWs. The majority of HCWs in the study reported hand-washing their mask themselves. This could explain the poor performance of two layered cloth masks, if the self-washing was inadequate. Cloth masks washed in the hospital laundry were as protective as medical masks. Both cloth and medical masks were contaminated, but only cloth masks were reused in the study, reiterating the importance of daily washing of reusable cloth masks using proper method. A well-washed cloth mask can be as protective as a medical mask.Trial resgistration numberACTRN12610000887077.
Journal Article
Poultry farmer response to disease outbreaks in smallholder farming systems in southern Vietnam
by
Delabouglise, Alexis
,
Thanh, Nguyen Thi Le
,
Lam, Ha Minh
in
Agricultural industry
,
Animal behavior
,
Animal Husbandry - statistics & numerical data
2020
Avian influenza outbreaks have been occurring on smallholder poultry farms in Asia for two decades. Farmer responses to these outbreaks can slow down or accelerate virus transmission. We used a longitudinal survey of 53 small-scale chicken farms in southern Vietnam to investigate the impact of outbreaks with disease-induced mortality on harvest rate, vaccination, and disinfection behaviors. We found that in small broiler flocks (≤16 birds/flock) the estimated probability of harvest was 56% higher when an outbreak occurred, and 214% higher if an outbreak with sudden deaths occurred in the same month. Vaccination and disinfection were strongly and positively correlated with the number of birds. Small-scale farmers – the overwhelming majority of poultry producers in low-income countries – tend to rely on rapid sale of birds to mitigate losses from diseases. As depopulated birds are sent to markets or trading networks, this reactive behavior has the potential to enhance onward transmission. The past few decades have seen the circulation of avian influenza viruses increase in domesticated poultry, regularly creating outbreaks associated with heavy economic loss. In addition, these viruses can sometimes ‘jump’ into humans, potentially allowing new diseases – including pandemics – to emerge. The Mekong river delta, in southern Vietnam, is one of the regions with the highest circulation of avian influenza. There, a large number of farmers practice poultry farming on a small scale, with limited investments in disease prevention such as vaccination or disinfection. Yet, it was unclear how the emergence of an outbreak could change the behavior of farmers. To learn more, Delabouglise et al. monitored 53 poultry farms, with fewer than 1000 chickens per farm, monthly for over a year and a half. In particular, they tracked when outbreaks occurred on each farm, and how farmers reacted. Overall, poultry farms with more than 17 chickens were more likely to vaccinate their animals and use disinfection practices than smaller farms. However, disease outbreaks did not affect vaccination or disinfection practices. When an outbreak occurred, farmers with fewer than 17 chickens tended to sell their animals earlier. For instance, they were 214% more likely to send their animals to market if an outbreak with sudden deaths occurred that month. Even if they do not make as much money selling immature individuals, this strategy may allow them to mitigate economical loss: they can sell animals that may die soon, saving on feeding costs and potentially avoiding further contamination. However, as animals were often sold alive in markets or to itinerant sellers, this practice increases the risk of spreading diseases further along the trade circuits. These data could be most useful to regional animal health authorities, which have detailed knowledge of local farming systems and personal connections in the communities where they work. This can allow them to effect change. They could work with small poultry farmers to encourage them to adopt efficient disease management strategies. Ultimately, this could help control the spread of avian influenza viruses, and potentially help to avoid future pandemics.
Journal Article
Stethoscope disinfection is rarely done in Ethiopia: What are the associated factors?
2019
The stethoscope, which is non-critical medical devices and a symbol of healthcare, is likely to be contaminated by pathogenic microorganisms and can play a contributory role in the transmission of hospital-acquired infection. And regular cleaning of the diaphragm of the stethoscope with a suitable disinfectant is decisive. However, in the resource-constrained setting like many healthcare facilities in Ethiopia healthcare provider's stethoscope disinfection practice and its associated factors have not been well studied so far. Therefore, this study sought to determine stethoscope disinfection practice and associated factors among the healthcare providers in Addis Ababa, Ethiopia.
A facility-based cross-sectional study was carried out between April and May 2016. For this study, 576 healthcare providers (physicians, health officers, nurses, midwives, and anesthesiologist) were included from 21 healthcare facilities in Addis Ababa. A pre-tested structured questionnaire was used for data collection. Descriptive statistics were computed. Bivariate and multivariable logistic regression analyses were used to identify factors that were significantly associated with stethoscope disinfection after every use.
A total of 546 healthcare providers participated in this study, for a response rate of 94.7%. Two-fifths, 39.7% (95%CI: 35.9, 44.0%) of healthcare providers disinfecting their stethoscope after every use. And a significant number of participants 34.6% (95%CI: 30.8, 38.5%) never disinfect their stethoscope. Three out of four (76.0%) healthcare providers believe that stethoscope contamination can contribute to the transmission of infections. Safe infection prevention practice (AOR = 3.79, 95%CI: 2.45-5.84), awareness on infection prevention guideline (AOR = 1.93; 95%CI: 1.31, 2.82), and favorable attitude towards infection prevention (AOR = 1.73, 95%CI: 1.02, 2.93) were significantly associated with stethoscope disinfection after every use. The study also found that the odds of stethoscope disinfection were likely to be reduced by 79% among physicians than nurses (AOR = 0.21; 95%CI: 0.09, 0.49).
Only a small proportion of healthcare providers disinfect their stethoscopes after every use. Factors such as safe infection prevention practice, awareness on infection prevention guidelines, and favorable attitude towards infection prevention were the independent predictors of stethoscopes disinfection after every use. Hence, promotion of stethoscope hygiene along with an educational program to enhance disinfection compliance in healthcare facilities may have a positive effect.
Journal Article
Handwashing and disinfection precautions taken by U.S. adults to prevent coronavirus disease 2019, Spring 2020
2020
Objectives
The objectives of this study were to assess self-reported hygiene precautions taken by U.S. adults during spring 2020 to prevent coronavirus disease 2019 (COVID-19) and to identify demographic characteristics associated with these hygiene precautions.
Results
We obtained data from Porter Novelli Public Services’s national survey,
Spring ConsumerStyles
, conducted March 19–April 9, 2020 among a nationally representative random sample of 6463 U.S. adults aged 18 years or older. We present data from the survey question: “What, if any, precautions are you taking to prevent coronavirus?”. Respondents replied yes or no to the following precautions: washing hands often with soap and water and disinfecting surfaces at home and work often. Most respondents reported taking hygiene-related precautions to prevent COVID-19; more respondents reported handwashing (93%) than disinfecting surfaces (74%). Men, younger respondents, those with lower income and education levels, and respondents in self-rated poor health had lower reported rates of both handwashing and disinfecting surfaces. Communications about hygiene precautions for COVID-19 prevention may need to target sub-populations with the greatest gaps in hygiene-related practices. Research identifying barriers to these practices and developing effective messaging could inform and improve these communications.
Journal Article
Chlorhexidine-impregnated sponge versus chlorhexidine gel dressing for short-term intravascular catheters: which one is better?
by
Buetti, Niccolò
,
Mimoz, Olivier
,
Timsit, Jean-François
in
Adult
,
Animals
,
Bandages - standards
2020
Background
Chlorhexidine-gluconate (CHG) impregnated dressings may prevent catheter-related bloodstream infections (CRBSI). Chlorhexidine-impregnated sponge dressings (sponge-dress) and gel dressings (gel-dress) have never been directly compared. We used the data collected for two randomized-controlled trials to perform a comparison between sponge-dress and gel-dress.
Methods
Adult critically ill patients who required short-term central venous or arterial catheter insertion were recruited. Our main analysis included only patients with CHG-impregnated dressings. The effect of gel-dress (versus sponge-dress) on major catheter-related infections (MCRI) and CRBSI was estimated using multivariate marginal Cox models. The comparative risks of dressing disruption and contact dermatitis were evaluated using logistic mix models for clustered data. An explanatory analysis compared gel-dress with standard dressings using either CHG skin disinfection or povidone iodine skin disinfection.
Results
A total of 3483 patients and 7941 catheters were observed in 16 intensive care units. Sponge-dress and gel-dress were utilized for 1953 and 2108 catheters, respectively. After adjustment for confounders, gel-dress showed similar risk for MCRI compared to sponge-dress (HR 0.80, 95% CI 0.28–2.31,
p
= 0.68) and CRBSI (HR 1.13, 95% CI 0.34–3.70,
p
= 0.85), less dressing disruptions (OR 0.72, 95% CI 0.60–0.86,
p
< 0.001), and more contact dermatitis (OR 3.60, 95% CI 2.51–5.15,
p
< 0.01). However, gel-dress increased the risk of contact dermatitis only if CHG was used for skin antisepsis (OR 1.94, 95% CI 1.38–2.71,
p
< 0.01).
Conclusions
We described a similar infection risk for gel-dress and sponge-dress. Gel-dress showed fewer dressing disruptions. Concomitant use of CHG for skin disinfection and CHG-impregnated dressing may significantly increase contact dermatitis.
Trials registration
These studies were registered within ClinicalTrials.gov (numbers
NCT01189682
and
NCT00417235
).
Journal Article
What Point-of-Use Water Treatment Products Do Consumers Use? Evidence from a Randomized Controlled Trial among the Urban Poor in Bangladesh
by
Unicomb, Leanne
,
Najnin, Nusrat
,
Mahmud, Minhaj
in
Bangladesh
,
Ceramic coatings
,
Ceramic powders
2011
There is evidence that household point-of-use (POU) water treatment products can reduce the enormous burden of water-borne illness. Nevertheless, adoption among the global poor is very low, and little evidence exists on why.
We gave 600 households in poor communities in Dhaka, Bangladesh randomly-ordered two-month free trials of four water treatment products: dilute liquid chlorine (sodium hypochlorite solution, marketed locally as Water Guard), sodium dichloroisocyanurate tablets (branded as Aquatabs), a combined flocculant-disinfectant powdered mixture (the PUR Purifier of Water), and a silver-coated ceramic siphon filter. Consumers also received education on the dangers of untreated drinking water. We measured which products consumers used with self-reports, observation (for the filter), and chlorine tests (for the other products). We also measured drinking water's contamination with E. coli (compared to 200 control households).
Households reported highest usage of the filter, although no product had even 30% usage. E. coli concentrations in stored drinking water were generally lowest when households had Water Guard. Households that self-reported product usage had large reductions in E. coli concentrations with any product as compared to controls.
Traditional arguments for the low adoption of POU products focus on affordability, consumers' lack of information about germs and the dangers of unsafe water, and specific products not meshing with a household's preferences. In this study we provided free trials, repeated informational messages explaining the dangers of untreated water, and a variety of product designs. The low usage of all products despite such efforts makes clear that important barriers exist beyond cost, information, and variation among these four product designs. Without a better understanding of the choices and aspirations of the target end-users, household-based water treatment is unlikely to reduce morbidity and mortality substantially in urban Bangladesh and similar populations.
Journal Article
Active environmental surveillance of SARS-CoV-2 in Midwestern United States meatpacking plants
2021
This pilot project investigated environmental SARS-CoV-2 presence in seven Midwestern meatpacking plants from May 2020 to January 2021. This study investigated social distancing and infection control practices and incorporated environmental sampling of surfaces and air in employee common areas. All plants increased their social distancing efforts, increased the frequency of cleaning and disinfecting worker areas, and screened for symptomatic people to prevent entry into the workplace. 575 samples from common areas were collected and evaluated with RT-qPCR for the presence of SARS-CoV-2. 42/367 surface samples were positive, while no virus was detected in air samples. Case positive data from the counties surrounding each plant showed peak positive SARS-CoV-2 cases from 12–55 days before the virus was detected in the plant, indicating that environmental sampling is likely a lagging indicator of community and plant infection.
Journal Article
Right approach: improvement in cleaning and disinfection of medical equipment in use – Sheikh Shakhbout Medical City (SSMC) experience
by
Maniamma, Prameela Maniamma
,
Rego, Joselita L
,
Al Hajjeh, Reham Jafer
in
Accountability
,
Audits
,
Compliance
2025
BackgroundIn 2021, Sheikh Shakhbout Medical City (SSMC) faced an increase in hospital-onset multidrug-resistant organisms; Candida auris increased to 1.4 per 1000 patient days, within critical care areas. This rise prompted the infection prevention and control team to enhance cleaning and disinfection practices, aiming to reduce infection transmission risks. The focus was on adherence to a structured cleaning protocol, which included high standards of equipment disinfection, regular audits and the establishment of roles and responsibilities for staff involved in cleaning and disinfection.MethodsTo improve compliance, the team initiated regular audits starting in May 2021, which revealed an initial compliance rate of 49%. These audits assessed adherence to infection control standards for equipment cleaning, including the thoroughness of cleaning for high-touch areas on medical devices. A multidisciplinary team met regularly to develop a risk-based categorisation system for equipment, providing clear guidelines on cleaning practices. In parallel, targeted training programmes were rolled out for environmental service personnel and nurses. By October 2023, a tagging system was implemented to streamline protocols and improve adherence by marking equipment with specific cleaning instructions.ResultsThe audits showed progressive improvements in compliance, reaching a peak of 100% by late 2022. However, staffing changes and turnovers affected adherence, with a temporary drop to 78% compliance in January 2023. The introduction of the tagging system in October 2023 contributed to a stabilised compliance rate exceeding 90% by early 2024, demonstrating the effectiveness of systematic interventions. The hospital-onset multidrug-resistant organism “C. auris” decreased to 0.5 per 1000 patient days in 2024.DiscussionTransferring cleaning responsibilities and implementing new tools emphasised the need for continuous training and communication. The risk-based categorisation and tagging systems were particularly effective in reinforcing cleaning protocols, even as staff turnover posed challenges.ConclusionsThrough these strategic initiatives, SSMC significantly improved the cleaning and disinfection of medical equipment in critical care, reducing the presence of hospital-onset C. auris and enhancing patient safety. Ongoing evaluation and adaptation remain vital for sustaining high standards in infection control.
Journal Article