Colorectal cancer screening for average‐risk adults: 2018 guideline update from the American Cancer Society
2018
In the United States, colorectal cancer (CRC) is the fourth most common cancer diagnosed among adults and the second leading cause of death from cancer. For this guideline update, the American Cancer Society (ACS) used an existing systematic evidence review of the CRC screening literature and microsimulation modeling analyses, including a new evaluation of the age to begin screening by race and sex and additional modeling that incorporates changes in US CRC incidence. Screening with any one of multiple options is associated with a significant reduction in CRC incidence through the detection and removal of adenomatous polyps and other precancerous lesions and with a reduction in mortality through incidence reduction and early detection of CRC. Results from modeling analyses identified efficient and model‐recommendable strategies that started screening at age 45 years. The ACS Guideline Development Group applied the Grades of Recommendations, Assessment, Development, and Evaluation (GRADE) criteria in developing and rating the recommendations. The ACS recommends that adults aged 45 years and older with an average risk of CRC undergo regular screening with either a high‐sensitivity stool‐based test or a structural (visual) examination, depending on patient preference and test availability. As a part of the screening process, all positive results on noncolonoscopy screening tests should be followed up with timely colonoscopy. The recommendation to begin screening at age 45 years is a qualified recommendation . The recommendation for regular screening in adults aged 50 years and older is a strong recommendation . The ACS recommends (qualified recommendations ) that: 1) average‐risk adults in good health with a life expectancy of more than 10 years continue CRC screening through the age of 75 years; 2) clinicians individualize CRC screening decisions for individuals aged 76 through 85 years based on patient preferences, life expectancy, health status, and prior screening history; and 3) clinicians discourage individuals older than 85 years from continuing CRC screening. The options for CRC screening are: fecal immunochemical test annually; high‐sensitivity, guaiac‐based fecal occult blood test annually; multitarget stool DNA test every 3 years; colonoscopy every 10 years; computed tomography colonography every 5 years; and flexible sigmoidoscopy every 5 years.
Journal Article
Cancer screening in the United States, 2018: A review of current American Cancer Society guidelines and current issues in cancer screening
by
Saslow, Debbie
,
Smith, Robert A
,
Brooks, Durado
in
Cancer
,
Cancer screening
,
Colorectal cancer
2018
Each year, the American Cancer Society publishes a summary of its guidelines for early cancer detection, data and trends in cancer screening rates from the National Health Interview Survey, and select issues related to cancer screening. In this 2018 update, we also summarize the new American Cancer Society colorectal cancer screening guideline and include a clarification in the language of the 2013 lung cancer screening guideline.
Journal Article
International evaluation of an AI system for breast cancer screening
2020
Screening mammography aims to identify breast cancer at earlier stages of the disease, when treatment can be more successful
1
. Despite the existence of screening programmes worldwide, the interpretation of mammograms is affected by high rates of false positives and false negatives
2
. Here we present an artificial intelligence (AI) system that is capable of surpassing human experts in breast cancer prediction. To assess its performance in the clinical setting, we curated a large representative dataset from the UK and a large enriched dataset from the USA. We show an absolute reduction of 5.7% and 1.2% (USA and UK) in false positives and 9.4% and 2.7% in false negatives. We provide evidence of the ability of the system to generalize from the UK to the USA. In an independent study of six radiologists, the AI system outperformed all of the human readers: the area under the receiver operating characteristic curve (AUC-ROC) for the AI system was greater than the AUC-ROC for the average radiologist by an absolute margin of 11.5%. We ran a simulation in which the AI system participated in the double-reading process that is used in the UK, and found that the AI system maintained non-inferior performance and reduced the workload of the second reader by 88%. This robust assessment of the AI system paves the way for clinical trials to improve the accuracy and efficiency of breast cancer screening.
An artificial intelligence (AI) system performs as well as or better than radiologists at detecting breast cancer from mammograms, and using a combination of AI and human inputs could help to improve screening efficiency.
Journal Article
Cancer screening in the United States, 2019: A review of current American Cancer Society guidelines and current issues in cancer screening
by
Saslow, Debbie
,
Smith, Robert A
,
Brooks, Durado
in
Cancer
,
Cancer screening
,
Medical screening
2019
Each year, the American Cancer Society publishes a summary of its guidelines for early cancer detection, data and trends in cancer screening rates, and select issues related to cancer screening. In this issue of the journal, the current American Cancer Society cancer screening guidelines are summarized, and the most current data from the National Health Interview Survey are provided on the utilization of cancer screening for men and women and on the adherence of men and women to multiple recommended screening tests.
Journal Article
Use of artificial intelligence for image analysis in breast cancer screening programmes: systematic review of test accuracy
by
Geppert, Julia
,
Todkill, Daniel
,
Freeman, Karoline
in
Accuracy
,
Algorithms
,
Artificial intelligence
2021
AbstractObjectiveTo examine the accuracy of artificial intelligence (AI) for the detection of breast cancer in mammography screening practice.DesignSystematic review of test accuracy studies.Data sourcesMedline, Embase, Web of Science, and Cochrane Database of Systematic Reviews from 1 January 2010 to 17 May 2021.Eligibility criteriaStudies reporting test accuracy of AI algorithms, alone or in combination with radiologists, to detect cancer in women’s digital mammograms in screening practice, or in test sets. Reference standard was biopsy with histology or follow-up (for screen negative women). Outcomes included test accuracy and cancer type detected.Study selection and synthesisTwo reviewers independently assessed articles for inclusion and assessed the methodological quality of included studies using the QUality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. A single reviewer extracted data, which were checked by a second reviewer. Narrative data synthesis was performed.ResultsTwelve studies totalling 131 822 screened women were included. No prospective studies measuring test accuracy of AI in screening practice were found. Studies were of poor methodological quality. Three retrospective studies compared AI systems with the clinical decisions of the original radiologist, including 79 910 women, of whom 1878 had screen detected cancer or interval cancer within 12 months of screening. Thirty four (94%) of 36 AI systems evaluated in these studies were less accurate than a single radiologist, and all were less accurate than consensus of two or more radiologists. Five smaller studies (1086 women, 520 cancers) at high risk of bias and low generalisability to the clinical context reported that all five evaluated AI systems (as standalone to replace radiologist or as a reader aid) were more accurate than a single radiologist reading a test set in the laboratory. In three studies, AI used for triage screened out 53%, 45%, and 50% of women at low risk but also 10%, 4%, and 0% of cancers detected by radiologists.ConclusionsCurrent evidence for AI does not yet allow judgement of its accuracy in breast cancer screening programmes, and it is unclear where on the clinical pathway AI might be of most benefit. AI systems are not sufficiently specific to replace radiologist double reading in screening programmes. Promising results in smaller studies are not replicated in larger studies. Prospective studies are required to measure the effect of AI in clinical practice. Such studies will require clear stopping rules to ensure that AI does not reduce programme specificity.Study registrationProtocol registered as PROSPERO CRD42020213590.
Journal Article
UK key performance indicators and quality assurance standards for colonoscopy
by
Rutter, Matt D
,
Rees, Colin J
,
Baragwanath, Phil
in
Adenoma - diagnosis
,
Adenoma - surgery
,
Anesthesia
2016
Colonoscopy should be delivered by endoscopists performing high quality procedures. The British Society of Gastroenterology, the UK Joint Advisory Group on GI Endoscopy, and the Association of Coloproctology of Great Britain and Ireland have developed quality assurance measures and key performance indicators for the delivery of colonoscopy within the UK. This document sets minimal standards for delivery of procedures along with aspirational targets that all endoscopists should aim for.
Journal Article
The IARC Perspective on Cervical Cancer Screening
2021
This article reviews recent evidence from the International Agency for Research on Cancer on the best methods of screening for cervical cancer, including by means of conventional cytology, visual inspection with acetic acid, human papillomavirus (HPV) nucleic acid testing, and combinations of these tests. HPV nucleic acid testing was superior whether used alone or in combination with other methods.
Journal Article
Cervical cancer screening for individuals at average risk: 2020 guideline update from the American Cancer Society
by
Saslow, Debbie
,
Smith, Robert A
,
Manassaram‐Baptiste, Deana
in
Cancer screening
,
Cellular biology
,
Cervical cancer
2020
The American Cancer Society (ACS) recommends that individuals with a cervix initiate cervical cancer screening at age 25 years and undergo primary human papillomavirus (HPV) testing every 5 years through age 65 years (preferred); if primary HPV testing is not available, then individuals aged 25 to 65 years should be screened with cotesting (HPV testing in combination with cytology) every 5 years or cytology alone every 3 years (acceptable) (strong recommendation). The ACS recommends that individuals aged >65 years who have no history of cervical intraepithelial neoplasia grade 2 or more severe disease within the past 25 years, and who have documented adequate negative prior screening in the prior 10 years, discontinue all cervical cancer screening (qualified recommendation). These new screening recommendations differ in 4 important respects compared with the 2012 recommendations: 1) The preferred screening strategy is primary HPV testing every 5 years, with cotesting and cytology alone acceptable where access to US Food and Drug Administration‐approved primary HPV testing is not yet available; 2) the recommended age to start screening is 25 years rather than 21 years; 3) primary HPV testing, as well as cotesting or cytology alone when primary testing is not available, is recommended starting at age 25 years rather than age 30 years; and 4) the guideline is transitional, ie, options for screening with cotesting or cytology alone are provided but should be phased out once full access to primary HPV testing for cervical cancer screening is available without barriers. Evidence related to other relevant issues was reviewed, and no changes were made to recommendations for screening intervals, age or criteria for screening cessation, screening based on vaccination status, or screening after hysterectomy. Follow‐up for individuals who screen positive for HPV and/or cytology should be in accordance with the 2019 American Society for Colposcopy and Cervical Pathology risk‐based management consensus guidelines for abnormal cervical cancer screening tests and cancer precursors.
Journal Article
European position statement on lung cancer screening
by
Bastarrika, Gorka
,
Sverzellati, Nicola
,
Becker, Nikolaus
in
Cancer screening
,
Drug addiction
,
Early Detection of Cancer - standards
2017
Lung cancer screening with low-dose CT can save lives. This European Union (EU) position statement presents the available evidence and the major issues that need to be addressed to ensure the successful implementation of low-dose CT lung cancer screening in Europe. This statement identified specific actions required by the European lung cancer screening community to adopt before the implementation of low-dose CT lung cancer screening. This position statement recommends the following actions: a risk stratification approach should be used for future lung cancer low-dose CT programmes; that individuals who enter screening programmes should be provided with information on the benefits and harms of screening, and smoking cessation should be offered to all current smokers; that management of detected solid nodules should use semi-automatically measured volume and volume-doubling time; that national quality assurance boards should be set up to oversee technical standards; that a lung nodule management pathway should be established and incorporated into clinical practice with a tailored screening approach; that non-calcified baseline lung nodules greater than 300 mm3, and new lung nodules greater than 200 mm3, should be managed in multidisciplinary teams according to this EU position statement recommendations to ensure that patients receive the most appropriate treatment; and planning for implementation of low-dose CT screening should start throughout Europe as soon as possible. European countries need to set a timeline for implementing lung cancer screening.
Journal Article
Colorectal cancer screening with faecal immunochemical testing, sigmoidoscopy or colonoscopy: a clinical practice guideline
2019
AbstractUpdate to this articleIn October 2022, three years after the initial publication of this guideline, the first trial of the effect of colonoscopy screening was published. The implications of this new evidence for the current recommendations were evaluated by the guideline panel in January 2023. The guideline panel judged that this new evidence did not alter the current recommendations, and therefore that an update of the following guideline was not needed (see table 2 for details).Clinical questionRecent 15-year updates of sigmoidoscopy screening trials provide new evidence on the effectiveness of colorectal cancer screening. Prompted by the new evidence, we asked: “Does colorectal cancer screening make an important difference to health outcomes in individuals initiating screening at age 50 to 79? And which screening option is best?”Current practiceNumerous guidelines recommend screening, but vary on recommended test, age and screening frequency. This guideline looks at the evidence and makes recommendations on screening for four screening options: faecal immunochemical test (FIT) every year, FIT every two years, a single sigmoidoscopy, or a single colonoscopy.RecommendationsThese recommendations apply to adults aged 50-79 years with no prior screening, no symptoms of colorectal cancer, and a life expectancy of at least 15 years. For individuals with an estimated 15-year colorectal cancer risk below 3%, we suggest no screening (weak recommendation). For individuals with an estimated 15-year risk above 3%, we suggest screening with one of the four screening options: FIT every year, FIT every two years, a single sigmoidoscopy, or a single colonoscopy (weak recommendation). With our guidance we publish the linked research, a graphic of the absolute harms and benefits, a clear description of how we reached our value judgments, and linked decision aids.How this guideline was createdA guideline panel including patients, clinicians, content experts and methodologists produced these recommendations using GRADE and in adherence with standards for trustworthy guidelines. A linked systematic review of colorectal cancer screening trials and microsimulation modelling were performed to inform the panel of 15-year screening benefits and harms. The panel also reviewed each screening option’s practical issues and burdens. Based on their own experience, the panel estimated the magnitude of benefit typical members of the population would value to opt for screening and used the benefit thresholds to inform their recommendations.The evidenceOverall there was substantial uncertainty (low certainty evidence) regarding the 15-year benefits, burdens, and harms of screening. Best estimates suggested that all four screening options resulted in similar colorectal cancer mortality reductions. FIT every two years may have little or no effect on cancer incidence over 15 years, while FIT every year, sigmoidoscopy, and colonoscopy may reduce cancer incidence, although for FIT the incidence reduction is small compared with sigmoidoscopy and colonoscopy. Screening related serious gastrointestinal and cardiovascular adverse events are rare. The magnitude of the benefits is dependent on the individual risk, while harms and burdens are less strongly associated with cancer risk.Understanding the recommendationBased on benefits, harms, and burdens of screening, the panel inferred that most informed individuals with a 15-year risk of colorectal cancer of 3% or higher are likely to choose screening, and most individuals with a risk of below 3% are likely to decline screening. Given varying values and preferences, optimal care will require shared decision making.
Journal Article