Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Language
      Language
      Clear All
      Language
  • Subject
      Subject
      Clear All
      Subject
  • Item Type
      Item Type
      Clear All
      Item Type
  • Discipline
      Discipline
      Clear All
      Discipline
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
1 result(s) for "Electronic hand hygiene recording and reminder system"
Sort by:
Reduction of nosocomial infections in the intensive care unit using an electronic hand hygiene compliance monitoring system
Introduction: Healthcare-associated infection is an important cause of mortality and morbidity worldwide. Well-regulated infection control and hand hygiene are the most effective methods for preventing healthcare-associated infections. This study evaluated and compared conventional hand hygiene observation and an electronic hand-hygiene recording and reminder system for preventing healthcare-associated infections. Methodology: This pre- and post-intervention study, employed an electronic hand-hygiene recording and reminder system for preventing healthcare-associated infections at a tertiary referral center. Healthcare-associated infection surveillance was recorded in an anesthesia and reanimation intensive care unit from April 2016 to August 2016. Hand-hygiene compliance was observed by conventional observation and an electronic recording and reminder system in two consecutive 2-month periods. healthcare-associated infections were calculated as incidence rate ratios. Results: The rate of healthcare-associated infections in the electronic hand- hygiene recording and reminder system period was significantly decreased compared with that in the conventional hand-hygiene observation period (incidence rate ratio = 0.58; 95% confident interval = 0.33-0.98). Additionally, the rate of central line-associated bloodstream infections and the rate of ventilator-associated pneumonia were lower during the electronic hand hygiene recording and reminder system period (incidence rate ratio= 0.41; 95% confident interval = 0.11-1.30 and incidence rate ratio = 0.67; 95% confident interval = 0.30-1.45, respectively). Conclusions: After implementing the electronic hand hygiene recording and reminder system, we observed a significant decrease in healthcare-associated infections and invasive device-associated infections. These results were encouraging and suggested that electronic hand hygiene reminder and recording systems may reduce some types of healthcare-associated infections in healthcare settings.