Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
16,899
result(s) for
"Enzyme Assays - methods"
Sort by:
Development of an in vitro potency assay for human skeletal muscle derived cells
by
Deutsch, Martin
,
Janke, Katrin
,
Troppmair, Jakob
in
Acetylcholinesterase
,
Acetylcholinesterase - metabolism
,
Anal Canal - pathology
2018
Potency is a quantitative measure of the desired biological function of an advanced therapy medicinal product (ATMP) and is a prerequisite for market approval application (MAA). To assess the potency of human skeletal muscle-derived cells (SMDCs), which are currently investigated in clinical trials for the regeneration of skeletal muscle defects, we evaluated acetylcholinesterase (AChE), which is expressed in skeletal muscle and nervous tissue of all mammals.
CD56+ SMDCs were separated from CD56- SMDCs by magnetic activated cell sorting (MACS) and both differentiated in skeletal muscle differentiation medium. AChE activity of in vitro differentiated SMDCs was correlated with CD56 expression, fusion index, cell number, cell doubling numbers, differentiation markers and compared to the clinical efficacy in patients treated with SMDCs against fecal incontinence.
CD56- SMDCs did not form multinucleated myotubes and remained low in AChE activity during differentiation. CD56+ SMDCs generated myotubes and increased in AChE activity during differentiation. AChE activity was found to accurately reflect the number of CD56+ SMDCs in culture, their fusion competence, and cell doubling number. In patients with fecal incontinence responding to SMDCs treatment, the improvement of clinical symptoms was positively linked with the AChE activity of the SMDCs injected.
AChE activity was found to truly reflect the in vitro differentiation status of SMDCs and to be superior to the mere use of surface markers as it reflects not only the number of myogenic SMDCs in culture but also their fusion competence and population doubling number, thus combining cell quality and quantification of the expected mode of action (MoA) of SMDCs. Moreover, the successful in vitro validation of the assay proves its suitability for routine use. Most convincingly, our results demonstrate a link between clinical efficacy and the AChE activity of the SMDCs preparations used for the treatment of fecal incontinence. Thus, we recommend using AChE activity of in vitro differentiated SMDCs as a potency measure in end stage (phase III) clinical trials using SMDCs for skeletal muscle regeneration and subsequent market approval application (MAA).
Journal Article
Evaluating the efficacy of protein quantification methods on membrane proteins
2024
Protein quantification is an important tool for a wide range of biological applications. The most common methods include the Lowry, bicinchoninic acid (BCA) and Coomassie Bradford assays. Despite their wide applicability, the mechanisms of action imply that these methods may not be ideal for large transmembrane proteins due to the proteins’ integration in the plasma membrane. Here, we investigate this problem by assessing the efficacy and applicability of these three common protein quantification methods on a candidate transmembrane protein: Na, K-ATPase (NKA). We compared these methods with an ELISA, which we newly developed and describe here for the quantification of NKA. The use of a relative standard curve allows this ELISA to be easily adapted to other proteins and across the animal kingdom. Our results revealed that the three conventional methods significantly overestimate the concentration of NKA compared with the ELISA. This is due to the samples containing a heterogeneous mix of proteins, including a significant amount of non-target proteins. Further, by applying the protein concentrations determined by the different methods to in vitro assays, we found that variation in the resulting data was consistently low when the assay reactions were prepared based on concentrations determined from the ELISA.
Journal Article
Phase 1 Clinical Trial of a Conditionally Replication-Defective Human Cytomegalovirus (CMV) Vaccine in CMV-Seronegative Subjects
by
Das, Rituparna
,
Tamms, Gretchen
,
Musey, Luwy
in
Adjuvants, Immunologic - administration & dosage
,
Adolescent
,
Adult
2019
A conditionally replication-defective human cytomegalovirus (CMV) vaccine (V160) derived from AD169 and genetically engineered to express CMV pentameric complex (gH/gL/pUL128/pUL130/pUL131) was developed and evaluated for phase 1 vaccine safety and immunogenicity in CMV-seronegative and CMV-seropositive adults.
Subjects received 3 doses of V160 or placebo on day 1, month 1, and month 6. Four vaccine dose levels, formulated with or without aluminum phosphate adjuvant, were evaluated. Injection-site and systemic adverse events (AEs) and vaccine viral shedding were monitored. CMV-specific cellular and humoral responses were measured by interferon-gamma ELISPOT and virus neutralization assay up to 12 months after last dose.
V160 was generally well-tolerated, with no serious AEs observed. Transient, mild-to-moderate injection-site and systemic AEs were reported more frequently in vaccinated subjects than placebo. Vaccine viral shedding was not detected in any subject, confirming the nonreplicating feature of V160. Robust neutralizing antibody titers were elicited and maintained through 12 months postvaccination. Cellular responses to structural and nonstructural viral proteins were observed, indicating de novo expression of viral genes postvaccination.
V160 displayed an acceptable safety profile. Levels of neutralizing antibodies and T-cell responses in CMV-seronegative subjects were within ranges observed following natural CMV infection.
. NCT01986010.
Journal Article
Activity assays for flavoprotein oxidases: an overview
2025
Flavoprotein oxidases have found many biotechnological applications. For identifying and improving their characteristics, it is essential to have reliable and robust assay methodology available. The methodologies used to monitor their activity seem to be scattered in the literature and seem often selected based on convenience. Due to the diversity of reactions catalyzed by flavoprotein oxidases, it is virtually impossible to recommend a single activity assay. A literature analysis of 60 recent papers describing flavoprotein oxidases revealed that continuous spectrophotometric assays, in particular colorimetric assays, are the preferred choice, as they are facile, scalable and allow for better interpretation of data than discontinuous assays. Colorimetric assays typically rely on the extinction coefficient of a monitored chromogenic product, which can be highly variable depending on the experimental conditions. Therefore, it is important to determine the extinction coefficient under the specific experimental conditions used, rather than taking it directly from the literature. To provide a guideline and assist in standardization, this review describes the most commonly utilized activity assays for flavoprotein oxidases, along with their respective merits and limitations.
Graphical Abstract
Key points
•
Researchers should be more aware of limitations of activity assays.
•
Extinction coefficients should be determined for the appropriate experimental setup.
•
New robust activity assays are desired.
Journal Article
Serum Antibodies Against the Oncogenic Merkel Cell Polyomavirus Detected by an Innovative Immunological Assay With Mimotopes in Healthy Subjects
by
Rotondo, John Charles
,
Infectiologie et Santé Publique (ISP) ; Université de Tours (UT)-Institut National de Recherche pour l’Agriculture, l’Alimentation et l’Environnement (INRAE)
,
Oton-Gonzalez, Lucia
in
Acquired immune deficiency syndrome
,
Adult
,
AIDS
2021
Merkel cell polyomavirus (MCPyV), a small DNA tumor virus, has been detected in Merkel cell carcinoma (MCC) and in normal tissues. Since MCPyV infection occurs in both MCC-affected patients and healthy subjects (HS), innovative immunoassays for detecting antibodies (abs) against MCPyV are required. Herein, sera from HS were analyzed with a novel indirect ELISA using two synthetic peptides mimicking MCPyV capsid protein epitopes of VP1 and VP2. Synthetic peptides were designed to recognize IgGs against MCPyV VP mimotopes using a computer-assisted approach. The assay was set up evaluating its performance in detecting IgGs anti-MCPyV on MCPyV-positive (n=65) and -negative (n=67) control sera. Then, the ELISA was extended to sera (n=548) from HS aged 18-65 yrs old. Age-specific MCPyV-seroprevalence was investigated. Performance evaluation indicated that the assay showed 80% sensitivity, 91% specificity and 83.9% accuracy, with positive and negative predictive values of 94.3% and 71%, respectively. The ratio expected/obtained data agreement was 86%, with a Cohen’s kappa of 0.72. Receiver-operating characteristic (ROC) curves analysis indicated that the areas under the curves (AUCs) for the two peptides were 0.82 and 0.74, respectively. Intra-/inter-run variations were below 9%. The overall prevalence of serum IgGs anti-MCPyV in HS was 62.9% (345/548). Age-specific MCPyV-seroprevalence was 63.1% (82/130), 56.7% (68/120), 64.5% (91/141), and 66.2% (104/157) in HS aged 18-30, 31-40, 41-50 and 51-65 yrs old, respectively (p>0.05). Performance evaluation suggests that our indirect ELISA is reliable in detecting IgGs anti-MCPyV. Our immunological data indicate that MCPyV infection occurs asymptomatically, at a relatively high prevalence, in humans.
Journal Article
Novel NanoLuc substrates enable bright two-population bioluminescence imaging in animals
2020
Sensitive detection of two biological events in vivo has long been a goal in bioluminescence imaging. Antares, a fusion of the luciferase NanoLuc to the orange fluorescent protein CyOFP, has emerged as a bright bioluminescent reporter with orthogonal substrate specificity to firefly luciferase (FLuc) and its derivatives such as AkaLuc. However, the brightness of Antares in mice is limited by the poor solubility and bioavailability of the NanoLuc substrate furimazine. Here, we report a new substrate, hydrofurimazine, whose enhanced aqueous solubility allows delivery of higher doses to mice. In the liver, Antares with hydrofurimazine exhibited similar brightness to AkaLuc with its substrate AkaLumine. Further chemical exploration generated a second substrate, fluorofurimazine, with even higher brightness in vivo. We used Antares with fluorofurimazine to track tumor size and AkaLuc with AkaLumine to visualize CAR-T cells within the same mice, demonstrating the ability to perform two-population imaging with these two luciferase systems.
NanoLuc substrates with improved solubility and bioavailability, hydrofurimazine and fluorofurimazine, strongly enhance bioluminescence signals in vivo and enable bright dual-color bioluminescent imaging with AkaLuc and AkaLumine.
Journal Article
A Simple Assay for Measuring Catalase Activity: A Visual Approach
by
Sugimoto, Shinya
,
Iwase, Tadayuki
,
Kamata, Yuko
in
631/1647/2196/2197
,
631/326/41/2537
,
Calibration
2013
In this study, an assay that combines the ease and simplicity of the qualitative approach for measuring catalase activity was developed. The assay reagents comprised only hydrogen peroxide and Triton X-100. The enzyme-generated oxygen bubbles trapped by Triton X-100 were visualized as foam, whose height was estimated. A calibration plot using the defined unit of catalase activity yielded the best linear fit over a range of 20–300 units (U) (y = 0.3794x − 2.0909, r
2
= 0.993). The assay precision and reproducibility at 100 U were 4.6% and 4.8%, respectively. The applicability of the assay for measuring the catalase activity of various samples was assessed using laboratory strains of
Escherichia coli
, catalase-deficient isogenic mutants, clinically isolated Shiga toxin-producing
E. coli
, and human cells. The assay generated reproducible results. In conclusion, this new assay can be used to measure the catalase activity of bacterial isolates and human cells.
Journal Article
Detecting total immunoglobulins in diverse animal species with a novel split enzymatic assay
2019
Background
Total immunolobulin G concentration is a useful, albeit underutilized, diagnostic parameter for health assessments of non-domestic animal species, due to a lack of functional diagnostic tools. Traditional assays, including enzyme-linked immunosorbent assay or radial immunodiffusion, require development of specific reagents (e.g., polyclonal antisera and appropriate protocols) for each animal species, precluding wide and easy adoption in wildlife welfare. As an alternative, bacterial virulence factors able to bind IgGs in antigen-independent manner can be used. To further simplify the diagnostic procedure and increase the number of species recognized by an assay, in this study a recently developed Split Trehalase immunoglobulin assay (STIGA) with bIBPs as a sensing elements was used to detect antibodies in 29 species from 9 orders. Three bacterial immunoglobulin binding proteins (protein G, protein A and protein L) were incorporated into STIGA reagents to increase the number of species recognized.
Results
IgG concentrations were detected through glucose production and produced signals were categorized in 4 categories, from not active to strong signal. Activation was detected in almost all tested animal species, apart from birds. Incorporation of Protein G, Protein A and Protein L allowed detection of IgGs in 62, 15.5 and 6.9% of species with a strong signal, respectively. Assays combining 2 bacterial immunoglobulin binding proteins as sensing element generally gave poorer performance than assays with the same bacterial immunoglobulin binding proteins fused to both trehalase fragments.
Conclusions
STIGA assays have potential to be further developed into an easily adoptable diagnostic test for total amount of IgGs in almost any serum sample, independent of species.
Journal Article
Measuring Myeloperoxidase Activity in Biological Samples
2013
Enzymatic activity measurements of the highly oxidative enzyme myeloperoxidase (MPO), which is implicated in many diseases, are widely used in the literature, but often suffer from nonspecificity and lack of uniformity. Thus, validation and standardization are needed to establish a robust method that is highly specific, sensitive, and reproducible for assaying MPO activity in biological samples.
We found conflicting results between in vivo molecular MR imaging of MPO, which measures extracellular activity, and commonly used in vitro MPO activity assays. Thus, we established and validated a protocol to obtain extra- and intracellular MPO from murine organs. To validate the MPO activity assays, three different classes of MPO activity assays were used in spike and recovery experiments. However, these assay methods yielded inconsistent results, likely because of interfering substances and other peroxidases present in tissue extracts. To circumvent this, we first captured MPO with an antibody. The MPO activity of the resultant samples was assessed by ADHP and validated against samples from MPO-knockout mice in murine disease models of multiple sclerosis, steatohepatitis, and myocardial infarction. We found the measurements performed using this protocol to be highly specific and reproducible, and when performed using ADHP, to be highly sensitive over a broad range. In addition, we found that intracellular MPO activity correlated well with tissue neutrophil content, and can be used as a marker to assess neutrophil infiltration in the tissue.
We validated a highly specific and sensitive assay protocol that should be used as the standard method for all MPO activity assays in biological samples. We also established a method to obtain extra- and intracellular MPO from murine organs. Extracellular MPO activity gives an estimate of the oxidative stress in inflammatory diseases, while intracellular MPO activity correlates well with tissue neutrophil content. A detailed step-by-step protocol is provided.
Journal Article
Evaluation of a Surrogate Enzyme-Linked Immunosorbent Assay–Based Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) cPass Neutralization Antibody Detection Assay and Correlation With Immunoglobulin G Commercial Serology Assays
2021
Emerging evidence shows correlation between the presence of neutralization antibodies (nAbs) and protective immunity against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Currently available commercial serology assays lack the ability to specifically identify nAbs. An enzyme-linked immunosorbent assay-based nAb assay (GenScript cPass neutralization antibody assay) has recently received emergency use authorization from the Food and Drug Administration.
To evaluate the performance characteristics of this assay and compare and correlate it with the commercial assays that detect SARS-CoV-2-specific immunoglobulin G (IgG).
Specimens from SARS-COV-2 infected patients (n = 124), healthy donors obtained prepandemic (n = 100), and patients with non-coronavirus disease 2019 (COVID-19) respiratory infections (n = 92) were analyzed using this assay. Samples with residual volume were also tested on 3 commercial serology platforms (Abbott, Euroimmun, Siemens). Twenty-eight randomly selected specimens from patients with COVID-19 and 10 healthy controls were subjected to a plaque reduction neutralization test.
The cPass assay exhibited 96.1% (95% CI, 94.9%-97.3%) sensitivity (at >14 days post-positive PCR), 100% (95% CI, 98.0%-100.0%) specificity, and zero cross-reactivity for the presence of non-COVID-19 respiratory infections. When compared with the plaque reduction assay, 97.4% (95% CI, 96.2%-98.5%) qualitative agreement and a positive correlation (R2 = 0.76) was observed. Comparison of IgG signals from each of the commercial assays with the nAb results from plaque reduction neutralization test/cPass assays displayed greater than 94.7% qualitative agreement and correlations with R2 = 0.43/0.68 (Abbott), R2 = 0.57/0.85 (Euroimmun), and R2 = 0.39/0.63 (Siemens), respectively.
The combined data support the use of cPass assay for accurate detection of the nAb response. Positive IgG results from commercial assays associated reasonably with nAbs presence and can serve as a substitute.
Journal Article